About Wire and Cable
More
Drop-Down Cable
Often used to wire pendant switches, this cable hangs from an overhead connection. It’s also known as bus drop cable.
The PVC insulation resists abrasion, chemicals, and oil.
Cable with strain relief has galvanized steel strain cables on the sides to provide strength and reduce the stress caused by equipment hanging from cable. Use the strain relief hardware (sold separately) to secure equipment to the cable.
- Use For: Drop-Down Power, Outdoors
- Flexible
- Temperature Range: 15° to 220° F
- Insulation: PVC Plastic
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
600V AC | |||||||||||
16 | 12 | 16/12 | 9 A @ 86° F | 0.58" | Yellow | Black, Blue, Blue/Black, Brown, Brown/Black, Orange, Orange/Black, Red, Red/Black, Yellow, Yellow/Black | UL Listed, C-UL Listed | 0000000 | 00000 | 00000 |
Strain Relief Hardware | 000000 | Each | 000000 |
Continuous-Flex Cable
Often used in automated applications such as robotics and cable carriers, this cable withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Rated for use in ISO Class 1 or ISO Class 2 clean rooms, this cable releases minimal particles into the air, helping you to maintain the cleanest possible environment.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Choose cable with PVC plastic outer insulation for general purpose indoor applications. Their protective layer resists abrasion, though it has the highest bend radius compared to other materials.
CE marked cable meets European health, safety, and environmental protection requirements.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the radius, the more the cable can bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
24 | 12 | 24/12 | 5 A @ 86° F | 0.33" | 2.48" | Gray | Black, Blue, Blue/Red, Brown, Gray, Green, Pink, Pink/Gray, Purple, Red, White, Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
20 | 12 | 20/12 | 10 A @ 86° F | 0.39" | 2.93" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 0000 | 0000 | |
18 | 12 | 18/12 | 13 A @ 86° F | 0.43" | 3.23" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 19 A @ 86° F | 0.51" | 3.83" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 0000 | 0000 | |
14 | 12 | 14/12 | 27 A @ 86° F | 0.69" | 5.18" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 0000 | |
600V AC | ||||||||||||||
20 | 12 | 20/12 | 4 A @ 86° F | 0.43" | 2.92" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 0.49" | 3.33" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 10 A @ 86° F | 0.59" | 4.01" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 0000 | 0000 | |
14 | 12 | 14/12 | 17 A @ 86° F | 0.73" | 4.96" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
- Use For: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Temperature Range: 25° to 155° F
- Inner Insulation:
300V AC: TPE Rubber
600V AC: PVC Plastic
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
300V AC | ||||||||||||||
24 | 12 | 24/12 | 3 A @ 86° F | 0.41" | 3.08" | Gray | Black, Blue, Blue/Red, Brown, Gray, Green, Pink, Pink/Gray, Purple, Red, White, Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
18 | 12 | 18/12 | 8 A @ 86° F | 0.51" | 3.83" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 12 A @ 86° F | 0.63" | 4.73" | Gray | Black, Green/Yellow | Clean Room | ISO Class 1 | UL Recognized Component, C-UL Recognized Component, CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 0000 | 0000 | |
600V AC | ||||||||||||||
20 | 12 | 20/12 | 8 A @ 86° F | 0.51" | 3.47" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 0000 | |
18 | 12 | 18/12 | 12 A @ 86° F | 0.55" | 3.74" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 0000 | |
16 | 12 | 16/12 | 18 A @ 86° F | 0.67" | 4.56" | Green | Black, Green/Yellow | Clean Room | ISO Class 2 | UL Recognized Component, C-UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Oil-Resistant Continuous-Flex Cable
This cable has an insulation with excellent resistance to oil, so it can be used near motors and equipment that require oil lubrication. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
- Use For: Automation, Continuous Motion
- Continuous Flex
- Insulation:
300 and 1000V AC: TPE Rubber Inner Insulation
600V AC: PVC Plastic Inner Insulation
See Table for Outer Insulation - Environment:
300 and 1000V AC: Clean Room
600V AC: Not Rated - Specifications Met:
300 and 1000V AC: UL Recognized Component, C-UL Recognized Component, Flame Rated VW-1
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
600V AC | ||||||||||||||
20 | 12 | 20/12 | 3 A @ 86° F | 45° to 190° | 0.4" | 3" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 000000 | 00000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 45° to 190° | 0.45" | 3.38" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 45° to 190° | 0.51" | 3.83" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
14 | 12 | 14/12 | 12 A @ 86° F | 45° to 190° | 0.68" | 5.1" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
1,000V AC | ||||||||||||||
24 | 12 | 24/12 | 3 A @ 86° F | -30° to 175° | 0.35" | 2.38" | Polyurethane Rubber | Gray | Black, Red, Blue, Brown, Gray, Green, Pink, Purple, White, Yellow, Blue/Red, Pink/Gray | ISO Class 1 | 0000000 | 0000 | 00 | |
Per Ft. | ||||||||||||||
1-99 | 100-Up | |||||||||||||
20 | 12 | 20/12 | 6 A @ 86° F | -30° to 175° | 0.39" | 2.65" | Polyurethane Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 0000 | 0000 | |
18 | 12 | 18/12 | 8 A @ 86° F | -30° to 175° | 0.47" | 3.2" | Polyurethane Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 12 A @ 86° F | -30° to 175° | 0.55" | 3.74" | Polyurethane Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 00000 | 00000 | |
14 | 12 | 14/12 | 17 A @ 86° F | -30° to 175° | 0.67" | 4.56" | Polyurethane Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 00000 | 00000 |
- Use For: Shielded: Automation, Continuous Motion, Interference Shielding
- Continuous Flex
- Insulation:
600V AC: PVC Plastic Inner Insulation
1,000V AC: TPE Rubber Inner Insulation
See Table for Outer Insulaton - Environment:
600V AC: Not Rated
1,000V AC: Clean Room - Specifications Met:
600V AC: UL Recognized Component, CSA Certified, Flame Rated VW-1
1,000V AC: UL Recognized Component, C-UL Recognized Component, Flame-Rated VW-1
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Temp. Range, °F | OD | Bend Radius | Outer Insulation Material | Outer Insulation Color | Inner Insulation Color | Environmental Rating | Length, ft. | 1-99 | 100-Up | |
600V AC | ||||||||||||||
18 | 12 | 18/12 | 7 A @ 86° F | 45° to 190° | 0.58" | 4.35" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 000000 | 000000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 45° to 190° | 0.64" | 4.8" | PVC Plastic | Black | Black, Green/Yellow | __ | 0000000 | 00000 | 00000 | |
1,000V AC | ||||||||||||||
20 | 12 | 20/12 | 6 A @ 86° F | -30° to 175° | 0.49" | 3.33" | Polyurethane Rubber, TPE Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 00000 | 0000 | |
18 | 12 | 18/12 | 8 A @ 86° F | -30° to 175° | 0.53" | 3.6" | Polyurethane Rubber, TPE Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 00000 | 00000 | |
16 | 12 | 16/12 | 12 A @ 86° F | -30° to 175° | 0.63" | 4.28" | Polyurethane Rubber, TPE Rubber | Gray | Black, Green/Yellow | ISO Class 1 | 0000000 | 00000 | 00000 |
No-Conduit-Required Continuous-Flex Cable
- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range: 25° to 175° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon Plastic, PVC Plastic
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. Often used in automated applications such as robotics, it withstands continuous motion without degrading data or signal transmission. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
20 | 12 | 20/12 | 4 A @ 86° F | 0.47" | 3.76" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 000000 | 00000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 0.5" | 4" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.56" | 4.48" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
14 | 12 | 14/12 | 13 A @ 86° F | 0.62" | 4.88" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
Shielded Stranded Wire | |||||||||||||
600V AC | |||||||||||||
20 | 12 | 20/12 | 4 A @ 86° F | 0.55" | 5.5" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 0.58" | 5.7" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.64" | 6.4" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
14 | 12 | 14/12 | 13 A @ 86° F | 0.69" | 6.9" | Gray | Black, Green/Yellow | TC-ER | UL Listed, CSA Certified, Flame Rated FT4 | 0000000 | 00000 | 00000 |
Continuous-Flex and -Twist Robotics Cable
- Use For:
Unshielded: Automation, Continuous Motion
Shielded: Automation, Continuous Motion, Interference Shielding - Continuous Flex
- Temperature Range:
300V AC, 600V AC: -40° to 175° F
1,000V AC: -10° to 175° F - Insulation:
Outer: Polyurethane Rubber
Inner: TPE Rubber
In addition to handling continuous movement, this cable withstands twisting up to 450° without degrading data or signal transmission. It's often used in welding robots and rotary tables. It’s flame rated VW-1 to meet requirements for preventing the spread of flame based on a timed test with vertically suspended material. The polyurethane rubber insulation resists abrasion and oil.
Use unshielded cable in applications where signal interference is not a concern.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
18 | 12 | 18/12 | 7 A @ 86° F | 0.5" | 6" | Black | Black, Green/Yellow | CSA Certified, UL Recognized Component, UL 2556 VW-1 | 0000000 | 000000 | 000000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.58" | 6.96" | Black | Black, Green/Yellow | CSA Certified, UL Recognized Component, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Long-Life Continuous-Flex Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -30° to 175° F
- Insulation:
Outer: Polyurethane Rubber
Inner: TPE Rubber
With a life span of more than 20 million high-speed flex cycles, this cable lasts twice as long as standard continuous-flex cable so you have to replace cable less frequently. Often used in automated applications such as robotics and cable carriers, it withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion, chemicals, and oil.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Continuous-Flex Data Communication Cable
- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Temperature Range:
PVC Plastic Insulation: 25° to 155° F
TPE Rubber Insulation: -30° to 210° F
Often used to send signal and data to order pickers and cranes, this cable withstands continuous motion applications without degrading data or signal transmission. In addition to a layer of braid shielding, it has twisted pairs of wires that cancel signal interference from multiple transmission lines. Suitable for clean rooms, it releases minimal particles into the air. It is CE marked as compliant with European health, safety, and environmental standards.
Cable with PVC insulation is for indoor use.
Cable with TPE rubber insulation is for outdoor use and resists coolant, oil, and UV light.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | OD | Bend Radius | Outer Insulation Color | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Shielded Stranded Wire with PVC Plastic Insulation | |||||||||||
300V AC | |||||||||||
24 | 12 | 24/12 | 0.37" | 2.63" | Gray | ISO Class 1 | CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
20 | 12 | 20/12 | 0.45" | 3.38" | Gray | ISO Class 1 | CE Marked, UL 2556 VW-1, NFPA 79 | 00000000 | 00000 | 0000 | |
Shielded Stranded Wire with TPE Rubber Insulation | |||||||||||
300V AC | |||||||||||
20 | 12 | 20/12 | 0.47" | 3.53" | Blue | ISO Class 1 | CE Marked | 00000000 | 00000 | 00000 |
Control Cable
- Use For:
Unshielded: Automation
Shielded: Automation; Interference Shielding - Flexible
- Temperature Range: 45° to 190° F
- Insulation: PVC Plastic
Send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. This cable is often used with conveyors, CNC machines, and to connect equipment to a control panel. The PVC insulation resists oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||
600V AC | |||||||||||
20 | 12 | 20/12 | 3 A @ 86° F | 0.38" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 0.45" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.5" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 0000 | |
Shielded Stranded Wire | |||||||||||
600V AC | |||||||||||
20 | 12 | 20/12 | 3 A @ 86° F | 0.48" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
18 | 12 | 18/12 | 7 A @ 86° F | 0.54" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.61" | Gray | Black, Green/Yellow | UL 2556 VW-1, UL Recognized Component, CSA Certified | 0000000 | 00000 | 00000 |
No-Conduit-Required Control Cable
- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon/PVC Plastic Blend
This cable meets TC-ER crush and impact requirements for exposed runs in cable carriers, so it can be used without conduit. It withstands periodic flexing and bending, sends signal and data to operate, measure, or regulate automated equipment. The PVC insulation resists oil. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
18 | 12 | 18/12 | 7 A @ 86° F | 0.48" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 00000 | 00000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.57" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 0000 | 0000 | |
14 | 12 | 14/12 | 7 A @ 86° F | 0.64" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 0000 | 0000 | |
Double-Shielded Stranded Wire | ||||||||||||
600V AC | ||||||||||||
18 | 12 | 18/12 | 7 A @ 86° F | 0.51" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 0000 | 0000 | |
16 | 12 | 16/12 | 9 A @ 86° F | 0.6" | Black | Black, Green/Yellow | TC-ER | UL Listed, C-UL Listed, CSA Certified, UL 2556 FT4 | 0000000 | 0000 | 0000 |
Thin-Insulation Control Cable
- Use For:
Unshielded: Automation
Double Shielded: Automation, Interference Shielding - Flexible
- Temperature Range: -40° to 220° F
- Insulation: Modified Polyphenylene Ether (mPPE) Plastic
Nearly two-thirds the diameter of standard control cable, this cable fits in tight spaces. The modified polyphenylene ether (mPPE) insulation is less than half the weight of the PVC insulation found on standard control cable, yet is more abrasion and cut resistant. Use it to send signal and data to operate, measure, or regulate automated equipment that requires cable to periodically flex and bend. It’s often used with conveyors, CNC machines, and to connect equipment to a control panel. Cable is flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Use unshielded cable in applications where signal interference is not a concern.
Double shielded cable has a layer of braid and foil shielding that provides excellent protection against signal interference from nearby equipment and devices.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Unshielded Stranded Wire | |||||||||||
600V AC | |||||||||||
20 | 12 | 20/12 | 3 A @ 86° F | 0.3" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 000000 | 000000 | |
18 | 12 | 18/12 | 4 A @ 86° F | 0.35" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
Double-Shielded Stranded Wire | |||||||||||
600V AC | |||||||||||
20 | 12 | 20/12 | 3 A @ 86° F | 0.34" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 | |
18 | 12 | 18/12 | 4 A @ 86° F | 0.39" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | UL Listed, C-UL Listed, UL 2556 VW-1 | 0000000 | 00000 | 00000 |
Flat Control Cable
- Use For: Automation
- Flexible
- Temperature Range: -40° to 220° F
- Insulation: PVC Plastic
Also known as festoon cable, this flat cable fits in confined spaces and withstands period flexing and bending, such as in overhead cranes and hoists. Use it to operate, measure, or regulate automated equipment. The PVC insulation resists oil and UV light. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | Per Ft. | |
Stranded Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||
16 | 12 | 16/12 | 15 A @ 86° F | 1.61" | 0.2" | Yellow | Black, Blue, Blue/Black, Brown, Brown/Black, Orange, Orange/Black, Red, Red/Black, Yellow, Yellow/Black | UL Listed, CSA Certified, UL 2556 VW-1 | 0000000 | 00000 | |
14 | 12 | 14/12 | 20 A @ 86° F | 1.81" | 0.23" | Yellow | Black, Blue, Blue/Black, Brown, Brown/Black, Orange, Orange/Black, Red, Red/Black, Yellow, Yellow/Black | UL Listed, CSA Certified, UL 2556 VW-1 | 0000000 | 0000 |
Flat Flexible Cable
- Temperature Range: -40° to 220° F
Made of thin, flattened wires, this flexible cable can be routed in tight spaces, such as inside a laptop. Connect it to your circuit board with flat flexible cable connectors (not included).
For technical drawings and 3-D models, click on a part number.
Riser-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-current circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | |||||||||||||
22 | 12 | 22/12 | 0.23" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | CMR, CL3R | UL 444 | 0000000 |
Duct-Rated Communication and Security System Cable
- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | |||||||||||||
22 | 12 | 22/12 | 0.23" | White | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | CMP, CL3P | UL 13, UL 444 | 0000000 |
Shielded Micro M12 Screw-Together Connectors
Block signal interference from nearby devices, such as motors and transmitters, while maintaining a strong, stable connection for M12 threads. The shielding on these connectors maintains signal integrity and minimizes signal loss between equipment. The threaded housing creates a secure connection that withstands the shaking and vibrating of industrial automation.
A-coded, these connectors are often used to connect equipment to IO Link controllers and devices within Profibus, DeviceNet, and other fieldbus systems. They work with both AC and DC devices such as sensors, motors, and light curtains. Poles and keyways on their face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
Connectors with polyurethane outer insulation are halogen free, so they won’t release toxic fumes or cause corrosion in metal. Polyurethane resists chemicals, oil, and UV rays, and is very flexible. It’s good for use in industrial environments and robotics.
All meet IP ratings when either mated or capped. IP67 rated connectors are protected from dust and temporary submersion.
Add caps to protect connectors and maintain their IP ratings when not in use.
Note: They may have extra holes on the face that are not used.
For technical drawings and 3-D models, click on a part number.
Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
9.5 ft. Cable Lead Lg. | |||||||||||||||
12 | A | 0.3" | 30V AC/30V DC | 1.5A | 26 | 0.26" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67 | 0000000 | 0000000 |
16 ft. Cable Lead Lg. | |||||||||||||||
12 | A | 0.3" | 30V AC/30V DC | 1.5A | 26 | 0.26" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67 | 0000000 | 000000 |
For Thread Size | Material | Each | |
For Sockets with Internal Threads | |||
---|---|---|---|
M12 | Anodized Aluminum | 0000000 | 000000 |