McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Outer Jacket Color
    System of Measurement
    Wire Construction
    Industrial Info Compare
    Outer Jacket Material
    Inner Insulation Marking
    Shield Type
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    69 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Unshielded.
    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Shielded.

    Unshielded

    Shielded

    Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending. Use it in moving equipment such as cable carriers.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    24/7
    5 amp @ 86° F1.95"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 100, 2505106N140000000000
    20/7
    10 amp @ 86° F2.25"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 100, 2508082K1300000000
    18/7
    13 amp @ 86° F2.33"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 100, 2508082K2100000000
    16/7
    19 amp @ 86° F2.78"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K2800000000
    14/7
    27 amp @ 86° F3.53"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K3500000000
     
    Shielded
    18/7
    9 amp @ 86° F2.93"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 100, 2505106N4900000000
    16/7
    14 amp @ 86° F3.53"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K4700000000
     
    600V AC
     
    Unshielded
    20/7
    4 amp @ 86° F2.4"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5, 10, 20, 30, 50, 1009204K1400000000
    20/7
    5 amp @ 86° F2.11"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1007673K5400000000
    18/7
    9 amp @ 86° F2.38"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1007673K2400000000
    18/7
    11 amp @ 86° F2.78"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5, 10, 20, 30, 50, 1009204K1800000000
    16/7
    14 amp @ 86° F2.79"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1007673K2900000000
    16/7
    14 amp @ 86° F3.15"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5, 10, 20, 30, 50, 1009204K260000000000
    14/7
    20 amp @ 86° F3.47"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1007673K3400000000
    14/7
    20 amp @ 86° F4.13"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5, 10, 20, 30, 50, 1009204K330000000000
    12/7
    24 amp @ 86° F4.95"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5, 10, 20, 30, 50, 1009204K850000000000
     
    Shielded
    20/7
    8 amp @ 86° F2.65"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 100, 2504514N3600000000
    18/7
    11 amp @ 86° F3.6"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5, 10, 20, 30, 50, 1009204K580000000000
    18/7
    12 amp @ 86° F2.79"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1007673K4500000000
    16/7
    14 amp @ 86° F3.98"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5, 10, 20, 30, 50, 1009204K660000000000
    16/7
    18 amp @ 86° F3.47"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1007673K5100000000
     

    Control Cable

    Control, monitor, and regulate stationary equipment such as sensors and PLCs. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Image of Product. Front orientation. Control Cable. Unshielded.
    Unshielded
    20/7
    4 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 100, 2509936K130000000000
    18/7
    11 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1009936K2100000000
    16/7
    14 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1009936K2800000000
    14/7
    20 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1009936K9200000000
     
    Image of Product. Front orientation. Control Cable. Shielded.
    Shielded
    20/7
    4 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1009936K5300000000
    18/7
    11 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1009936K6100000000
    16/7
    14 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1009936K6800000000
    14/7
    20 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1009936K780000000000
     

    Power Cable

    Image of Product. Front orientation. Power Cable.
    Built for rough handling and frequent positioning, this cable delivers power you can count on. Use it for everything from extension cords to cords for hydraulic presses. Made to NEC Article 400 requirements, you can trust it to power whatever you need. Plus, the flexible jacket takes the struggle out of routing it through tight spaces and around machinery.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-249
    250-Up
    600V AC
     
    SOOW Cable
    18/7
    5 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K50000000000
    16/7
    8 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K600000000
     

    No-Conduit-Required Control Cable

    Made to TC-ER (Tray Cable, Exposed Run) standards, this crush- and impact-resistant cable eliminates the cost and hassle of installing conduit. It’s ideal for exposed runs, such as from a cable tray down to a control panel or motor control box. Support it every six feet to prevent sagging. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Double Shielded—With two layers of shielding, this cable offers better protection against electromagnetic interference (EMI) than single-shielded cable. It’s often used near transformers, generators, and heavy-duty motors that may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Image of Product. Front orientation. Control Cable. No-Conduit-Required Control Cable, Unshielded.
    Unshielded
    18/7
    11 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 100, 2506452T440000000000
    16/7
    14 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T6400000000
    14/7
    12 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T1900000000
    12/7
    16 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T8400000000
     
    Image of Product. Front orientation. Control Cable. No-Conduit-Required Control Cable, Double Shielded.
    Double Shielded
    18/7
    11 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T5400000000
    16/7
    14 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T7400000000
    14/7
    12 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T2900000000
    12/7
    16 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T94000000000
     

    No-Conduit-Required Continuous-Flex Control Cable

    Eliminate the need for conduit and cable splices. Made to TC-ER (Tray Cable, Exposed Run) standards, this cable resists impact and crushing force. You can run a single length from stationary equipment to and through moving equipment, such as cable carriers. Support it every six feet to prevent sagging. Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope, strengthening the cable and preventing fatigue from constant bending.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Image of Product. Front orientation. Control Cable. No-Conduit-Required Continuous-Flex Control Cable, Unshielded.
    Unshielded
    20/7
    5 amp @ 86° F3.04"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T650000000000
    18/7
    8 amp @ 86° F3.2"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T7100000000
    16/7
    14 amp @ 86° F3.52"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T1800000000
    14/7
    20 amp @ 86° F4.08"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T250000000000
     
    Image of Product. Front orientation. Control Cable. No-Conduit-Required Continuous-Flex Control Cable, Shielded.
    Shielded
    20/7
    5 amp @ 86° F4.6"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T790000000000
    18/7
    8 amp @ 86° F4.8"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T850000000000
    16/7
    14 amp @ 86° F5.2"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T480000000000
    14/7
    20 amp @ 86° F5.9"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10, 20, 30, 50, 1009700T550000000000
     

    Abrasion-Resistant Continuous-Flex Control Cable

    Prevent wear and tear in rough areas and conditions. Unlike other continuous-flex control cables, the rugged polyurethane jacket on this cable protects against abrasion as well as exposure to chemicals, oil, and moisture. It’s often used in cable carriers in high-production CNC machines that need reliable signals for millions of flex cycles. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    1,000V AC
     
    Image of Product. Front orientation. Control Cable. Abrasion-Resistant Continuous-Flex Control Cable, Unshielded.
    Unshielded
    20/7
    8 amp @ 86° F2.04"Polyurethane Rubber
    Gray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1007323N170000000000
    18/7
    11 amp @ 86° F2.24"Polyurethane Rubber
    Gray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K6200000000
    16/7
    16 amp @ 86° F2.79"Polyurethane Rubber
    Gray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K6600000000
    14/7
    23 amp @ 86° F3.33"Polyurethane Rubber
    Gray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K79000000000
     
    Image of Product. Front orientation. Control Cable. Abrasion-Resistant Continuous-Flex Control Cable, Shielded.
    Shielded
    20/7
    8 amp @ 86° F2.52"Polyurethane Rubber over TPEGray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1007323N5500000000
    18/7
    11 amp @ 86° F2.79"Polyurethane Rubber over TPEGray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1007323N6200000000
    16/7
    16 amp @ 86° F3.33"Polyurethane Rubber over TPEGray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1008082K8600000000
    14/7
    23 amp @ 86° F3.88"Polyurethane Rubber over TPEGray-30 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 1007323N830000000000
     

    Space-Saving Control Cable

    This cable is about two-thirds the diameter of other control cables of the same gauge, so you can fit more cables into the same footprint. The mPPE (modified polyphenylene ether) outer jacket is half the weight of other materials, but still abrasion and tear resistant. This cable controls, monitors, and regulates stationary equipment such as sensors and PLCs. You can flex and bend it during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Double Shielded—With two layers of shielding, this cable offers better protection against electromagnetic interference (EMI) than single-shielded cable. It’s often used near transformers, generators, and heavy-duty motors that may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Image of Product. Front orientation. Control Cable. Space-Saving Control Cable, Unshielded.
    Unshielded
    20/7
    4 amp @ 86° FmPPEGray-40 to 220UL 2556 VW-1
    C-UL Listed, UL Listed
    10, 20, 30, 50, 1006650T13000000000000
    18/7
    6 amp @ 86° FmPPEGray-40 to 220UL 2556 VW-1
    C-UL Listed, UL Listed
    10, 20, 30, 50, 1006650T210000000000
     
    Image of Product. Front orientation. Control Cable. Space-Saving Control Cable, Double Shielded.
    Double Shielded
    20/7
    4 amp @ 86° FmPPEGray-40 to 220UL 2556 VW-1
    C-UL Listed, UL Listed
    5, 10, 20, 30, 506650T290000000000
    18/7
    6 amp @ 86° FmPPEGray-40 to 220UL 2556 VW-1
    C-UL Listed, UL Listed
    5, 10, 20, 30, 506650T370000000000
     

    Continuous-Twist and -Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Twist and -Flex Control Cable, Unshielded.

    Unshielded

    Ideal for multi-axis, torsional, and bending movements, this cable is often used in robot arms. It will endure millions of flex cycles while sending reliable signals, even when it's twisting. Internally, fine strands of conductors are twisted together like a rope, resisting fatigue from constant bending. On the outside, a rugged polyurethane jacket resists abrasion, chemicals, oil, and moisture.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    24/7
    2.6 amp @ 86° F3.36"Polyurethane Rubber
    Black-40 to 175UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1008559K43000000000000
     
    600V AC
     
    Unshielded
    18/7
    11 amp @ 86° F4.92"Polyurethane Rubber
    Black-40 to 175UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1008559K460000000000
    16/7
    14 amp @ 86° F5.52"Polyurethane Rubber
    Black-40 to 175UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1008559K240000000000
     

    Long-Life Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Long-Life Continuous-Flex Control Cable.
    Replace cables in your moving equipment less frequently. Often used in cable carriers, this cable lasts 20 million flex cycles, at least twice as long as most other continuous-flex cable. A rugged polyurethane jacket protects it from abrasion and exposure to chemicals, oil, and moisture. This cable maintains reliable signals despite the demands of continuous motion. Inside, finely stranded conductors are twisted together like a rope to strengthen the cable and prevent fatigue from constant bending.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    18/7
    11 amp @ 86° F2.48"Polyurethane Rubber
    Gray-30 to 1755, 10, 20, 30, 50, 1009221K530000000000
    16/7
    14 amp @ 86° F2.85"Polyurethane Rubber
    Gray-30 to 1755, 10, 20, 30, 50, 1009221K570000000000
    14/7
    20 amp @ 86° F3.68"Polyurethane Rubber
    Gray-30 to 1755, 10, 20, 30, 50, 1009221K630000000000
     

    Coiled Power Cable

    Image of Product. Front orientation. Power Cable. Coiled Power Cable.
    Extend to full length for added reach, then watch this cable retract and self-coil for convenience. It's often used with hand tools, pendant switches, and other portable devices.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Certification
    Extends from 2
    ft. to 10 ft. Long
    Extends from 4
    ft. to 20 ft. Long
    300V AC
     
    SJOW Cable
    18/7
    4 amp @ 86° FNeoprene
    Black-40 to 140UL Listed
    7088K21300000000000000
     
    600V AC
     
    SOW Cable
    16/7
    7 amp @ 86° FNeoprene
    Black-40 to 190CSA Certified, UL Listed
    7088K222000000000000
     

    Irrigation Cable

    Image of Product. Front orientation. Irrigation Cable.
    This wire is often used for sprinkler systems.
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Outer Jacket
    Color
    Inner Insulation
    Material
    Inner Insulation Color
    Temp. Range,
    ° F
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    Solid Wire with Polyethylene Outer Jacket
     
    30V AC/30V DC
    18
    718/7
    0.27"BlackPolypropylene
    Blue, Brown, Green, Orange, Red, White, Yellow0 to 140UL Listed
    8070T1600000000000000000000000000000000000000
     

    Coiled Control Cable

    Image of Product. Front orientation. Control Cable. Coiled Control Cable, Unshielded.

    Unshielded

    This cable gives you room to roam. It extends as you move, then retracts and self-coils for convenience. It's often used with low-current communication equipment such as microphones and headsets.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Certification
    Extends from 2
    ft. to 10 ft. Long
    Extends from 4
    ft. to 20 ft. Long
    300V AC
     
    Unshielded
    23/71 amp @ 86° FNeoprene
    Black-40 to 140UL Listed
    69115K220000000000000
     