McMaster-Carr logo
    Filter by
    Number of Poles
    Electrical Connection Coding
    Industrial Info Snippet
    System of Measurement
    Housing Thread Size
    Industrial Info Snippet
    Housing Thread Location
    Electrical Connector Component
    Thread Size
    Industrial Info Snippet
    Housing Material
    For Wire Gauge
    Electrical Connection
    Shielding
    Environment
    Housing Connection Method
    Enclosure Rating
    Minimum Temperature
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Compare
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    10 Products

    M12 Connectors

    These connectors run the automated world, from robot arms and photoelectric sensors to PLCs, IO-Link devices, and Ethernet switches. The original metric circular connector, they continue to be the standard today. They screw together tightly to protect against contaminants and hold firm against high vibration. Each one has a coding that indicates a unique keyway, preventing mismated connection errors before they happen. The coding also tells you whether a connector can send power, control, or data. Some can send a combination of the three, reducing the need for multiple connectors.
    Plugs
    Image of Product. Front orientation. Metric Circular Connectors. M12 Connectors, Plugs, Unshielded.

    Unshielded

    Plugs
    Caps
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Wire Connection
    Method
    Enclosure
    Rating
    Each
    Each
    Unshielded
    A
    530V AC/36V DC4Screw TerminalIP67
    7209K440000006897K73000000
     
    90° Elbow Plugs
    Image of Product. Front orientation. Metric Circular Connectors. M12 Connectors, 90° Elbow Plugs, Unshielded.

    Unshielded

    Plugs
    Caps
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Wire Connection
    Method
    Enclosure
    Rating
    Each
    Each
    Unshielded
    A
    530V AC/36V DC4Screw TerminalIP67
    7209K450000006897K73000000
     
    Sockets
    Image of Product. Front orientation. Metric Circular Connectors. M12 Connectors, Sockets, Unshielded.

    Unshielded

    Sockets
    Caps
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Wire Connection
    Method
    Enclosure
    Rating
    Each
    Each
    Unshielded
    A
    530V AC/36V DC4Screw TerminalIP67
    7209K460000006897K74000000
     
    90° Elbow Sockets
    Image of Product. Front orientation. Metric Circular Connectors. M12 Connectors, 90° Elbow Sockets, Unshielded.

    Unshielded

    Sockets
    Caps
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Wire Connection
    Method
    Enclosure
    Rating
    Each
    Each
    Unshielded
    A
    530V AC/36V DC4Screw TerminalIP67
    7209K260000006897K74000000
     

    Ultra-Flexible Constant-Wattage Heating Tape for Pipes and Tubes

    Image of ProductInUse. Front orientation. Heating Tape. Ultra-Flexible Constant-Wattage Heating Tape for Pipes and Tubes, Hardwire.

    Hardwire

    Wrap the flexible heating element around small-diameter pipes and tubes or pack it into tight spaces. These heaters maintain a consistent heat output along the entire length of the cable, regardless of the environmental temperature. All require a temperature switch or controller to regulate heat output. They do not produce an electromagnetic field, so they can be used near electronics.
    Note: Only install these heaters in accessible locations; do not install them behind walls, underground, or in other difficult-to-access areas. Use fiberglass tape or heat-transfer putty to install them directly on surfaces that are free of dirt, grease, and rough edges. Do not use electrical tape, duct tape, metal bands, or wire. To prevent heat loss and protect heaters from moisture and corrosion, wrap them with fiberglass insulation.
    Lg.,
    ft.
    Wattage,
    W
    Watt Density,
    W/ft
    Current,
    amp
    Wd.
    Thk.
    Environment
    Temp. Range, ° F
    Cable Cover
    Material
    For Surface
    Material
    Each
    Hardwire
     
    36V DC
    3930.30.12"0.06"-30 to 220Polymer FiberMetal, Plastic2156T13000000
    61830.50.12"0.06"-30 to 220Polymer FiberMetal, Plastic2156T1400000
    92730.80.12"0.06"-30 to 220Polymer FiberMetal, Plastic2156T1500000
    1236310.12"0.06"-30 to 220Polymer FiberMetal, Plastic2156T16000000
     
    back to top