McMaster-Carr logo
    Filter by
    Inlet Pipe Size
    Industrial Info Compare
    Inlet Thread Type
    Industrial Info Compare
    Outlet Pipe Size
    Industrial Info Compare
    Maximum Temperature
    Seal Material
    Relief Port Pipe Size
    Industrial Info Compare
    Thread Type
    Industrial Info Compare
    Inlet Gender
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Inlet CGA Number
    Industrial Info Compare
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    54 Products

    ASME-Code Fast-Acting Pressure-Relief Valves for Cryogenic Fluids

    These valves meet ASME Code Section VIII for use with cryogenic pressure vessels. Rated for use with argon, carbon dioxide, helium, hydrogen, methane, nitrogen, and oxygen, they are cleaned and bagged for oxygen service and other high-purity applications. All spring fully open at the set pressure and remain open until the system pressure is restored below the set pressure. Attach a drain line to the threaded relief port for remote discharge.
    NPT Male Inlet and NPT Female Relief Port
    Image of Product. Front orientation. Pressure-Relief Valves. ASME-Code Fast-Acting Pressure-Relief Valves for Cryogenic Fluids.
    Inlet
    Relief
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Port Pipe
    Size
    Port
    Location
    Shape
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Valve
    Type
    Certification
    Choose a Set Pressure, psi
    Each
     
    Brass Body—Brass Seal
    1/2
    Bottom6003/4
    Side90° Elbow6 9/16"Argon, Carbon Dioxide, Helium, Hydrogen, Methane, Nitrogen, Oxygen-320 to 150Pop SafetyASME BPVC.VIII
    20
    ,
    30
    ,
    40
    ,
    50
    ,
    60
    ,
    70
    ,
    80
    ,
    90
    ,
    100
    ,
    110
    ,
    120
    ,
    130
    ,
    140
    ,
    150
    ,
    160
    ,
    170
    ,
    180
    ,
    190
    ,
    200
    ,
    210
    ,
    220
    ,
    230
    ,
    240
    ,
    250
    ,
    260
    ,
    270
    ,
    280
    ,
    290
    ,
    300
    8089K120000000
    3/4
    Bottom6001
    Side90° Elbow6 9/16"Argon, Carbon Dioxide, Helium, Hydrogen, Methane, Nitrogen, Oxygen-320 to 150Pop SafetyASME BPVC.VIII
    20
    ,
    30
    ,
    40
    ,
    50
    ,
    60
    ,
    70
    ,
    80
    ,
    90
    ,
    100
    ,
    110
    ,
    120
    ,
    130
    ,
    140
    ,
    150
    ,
    160
    ,
    170
    ,
    180
    ,
    190
    ,
    200
    ,
    210
    ,
    220
    ,
    230
    ,
    240
    ,
    250
    ,
    260
    ,
    270
    ,
    280
    ,
    290
    ,
    300
    8089K14000000
     

    Clean Room Panel-Mount Pressure-Regulating Valves for Air and Inert Gas

    Maintain contaminant-free standards in clean room environments. These valves come cleaned and bagged to Fed. Spec. Class 100 and ISO Class 5 clean room standards and have a 316 stainless steel body with a smooth finish to resist dust collection. They automatically reduce a high, variable inlet pressure to a lower, stable output pressure. Valves have threads below the adjustment knob and come with a panel-mount nut. Adjust the outlet pressure within the range.
    NPT Female
    Image of Product. Front orientation. Pressure-Regulating Valves. Clean Room Panel-Mount Pressure-Regulating Valves for Air and Inert Gas.
    Nonrelieving—Nonrelieving valves do not exhaust excess downstream pressure.
    1 Gauge Port—Gauge ports let you attach a pressure gauge.
    Valves
    Brackets
    Inlet
    Outlet
    Gauge Port
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure
    Range, psi
    No. of
    Ports
    Pipe
    Size
    Location
    End-to-End
    Lg.
    Panel Cutout
    Dia.
    Clean Room Std.
    For Use With
    Temp. Range,
    ° F
    Each
    Each
    316 Stainless Steel Body—Fluoroelastomer Diaphragm and Seal
     
    Nonrelieving
    1/8
    Side1451/8
    Side7 to 10211/4
    Side1.700"1.2"Fed. Std. Class 100, ISO Class 5
    Air, Nitrogen, Carbon Dioxide, Argon32 to 1404238K4100000004238K5100000
    1/4
    Side1451/4
    Side7 to 10211/4
    Side1.700"1.2"Fed. Std. Class 100, ISO Class 5
    Air, Nitrogen, Carbon Dioxide, Argon32 to 1404238K420000004238K510000
    1/4
    Side1451/4
    Side7 to 10211/4
    Side2.280"1.44"Fed. Std. Class 100, ISO Class 5
    Air, Nitrogen, Carbon Dioxide, Argon32 to 1404238K430000004238K5200000
    3/8
    Side1453/8
    Side7 to 10211/4
    Side2.280"1.44"Fed. Std. Class 100, ISO Class 5
    Air, Nitrogen, Carbon Dioxide, Argon32 to 1404238K440000004238K5200000
    1/2
    Side1451/2
    Side7 to 10211/4
    Side2.280"1.44"Fed. Std. Class 100, ISO Class 5
    Air, Nitrogen, Carbon Dioxide, Argon32 to 1404238K450000004238K5200000
     
    Pressure Gauges

    Long-Life Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Long-Life Pressure-Regulating Valves for Cryogenic Liquids.
    For a longer service life than standard valves for cryogenic liquids, these have a durable bronze body. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves are designed to withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. They have an internal strainer to trap debris.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Bronze Body—Bronze Diaphragm and PTFE Seal with Internal Strainer
    1/4
    Side4001/4
    SideScrew3 1/16"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 30
    ,
    75 to 250
    49165K390000000
    1/2
    Side4001/2
    SideScrew4 1/2"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 30
    ,
    20 to 75
    ,
    20 to 100
    ,
    50 to 250
    49165K59000000
    1
    Side4001
    SideScrew5 7/8"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 35
    ,
    20 to 60
    ,
    20 to 100
    ,
    75 to 250
    49165K79000000
     

    Tank-Mount Pressure-Regulating Valves for Air and Inert Gas

    These valves automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    Single Stage
    Image of Product. Female Outlet × Female Inlet Single-Stage Valves with Knob. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Single Stage, Female Outlet, UNF Outlet Thread, Female Inlet, Outlet-Pressure-Adjustment Knob.
    Image of Product. UNF Male Outlet × Female Inlet Single-Stage Valves with T-Handle. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Single Stage, Female Inlet, UNF Outlet Thread, Male Outlet, Outlet-Pressure-Adjustment T-Handle.

    Female Outlet ×

    Female Inlet

    Single-Stage Valves

    with Knob

    UNF Male Outlet × Female

    Inlet Single-Stage

    Valves with T-Handle

    Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
    Brass Body—Valves with a brass body have a longer service life than valves with a brass and steel body.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    Location
    Thread
    Direction
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Body
    Seal
    Diaphragm
    Temp. Range,
    ° F
    Each
    For Carbon Dioxide
     
    5/8"-18 UNF Female Outlet × NGO Female Inlet
    320
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 145KnobBrassPTFENeoprene-20 to 1203687N1120000000
     
    9/16"-18 UNF Male Outlet × NGO Female Inlet
    320
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrassPTFERubber-20 to 1207897A39000000
     
    Two Stage
    Image of Product. NPT Female Outlet × Female Inlet Two-Stage Valves with T-Handle. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Two Stage, NPT Outlet Thread, Female Outlet, Female Inlet, Outlet-Pressure-Adjustment T-Handle.
    Image of Product. UNF Female Outlet x Female Inlet Two-Stage Valves with T-Handle. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Two Stage, Female Outlet, UNF Outlet Thread, Female Inlet, Outlet-Pressure-Adjustment T-Handle.

    NPT Female Outlet ×

    Female Inlet Two-Stage

    Valves with T-Handle

    UNF Female Outlet x

    Female Inlet Two-Stage

    Valves with T-Handle

    Two-stage valves progressively reduce pressure over two steps for more consistent outlet pressure at all times. They’re often used in applications that require a constant outlet pressure regardless of the tank level.
    Brass Body—Valves with a brass body have a longer service life than valves with a brass and steel body.
    Stainless Steel Diaphragm—Valves with a stainless steel diaphragm can withstand harsh environments.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    Location
    Thread
    Direction
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Body
    Seal
    Diaphragm
    Temp. Range,
    ° F
    Each
    For Carbon Dioxide
     
    1/4 NPT Female Outlet × NGO Female Inlet
    320
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 250T-HandleBrassPTFENeoprene-20 to 1203687N1240000000
    320
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 250T-HandleBrassPTFEStainless Steel-20 to 1203687N129000000
     
    5/8"-18 UNF Female Outlet × NGO Female Inlet
    320
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrass/SteelPTFERubber-20 to 1207897A17000000
     

    Pressure-Relief Valves for Cryogenic Applications

    Image of Product. Front orientation. Pressure-Relief Valves. Pressure-Relief Valves for Cryogenic Applications.
    Cleaned and bagged to meet CGA G-4.1 for oxygen service and other high-purity applications, these valves are built to withstand the extreme cold of liquid carbon dioxide, liquid nitrogen, and liquid oxygen. They begin opening at the set pressure and fully open at about 10% over the set pressure. Valves begin closing as pressure drops and fully close when the system pressure is restored below the set pressure. Set pressure is not adjustable. Valves are not intended for direct contact with cryogenic liquids.
    Riser Tubes—Riser tubes (sold separately) are required to convert cryogenic liquids into gases before they contact the valve. 3/8 NPT valve requires a 1/2 NPT × 3/8 NPT bushing when using a riser.
    Adapters—Adapters (sold separately) convert the valve relief-port connection from UNEF female threads to NPT female threads.
    Valves
    Riser Tubes
    Adapters
    Inlet
    Relief
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Port Thread
    Size
    Port
    Location
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Choose a Set Pressure, psi
    Each
    Each
    Each
    NPT Male Inlet and UNEF Female Relief Port
     
    Brass Body
    1/4
    Bottom6003/4"-20
    Top2 5/8"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 165
    22
    ,
    35
    ,
    50
    ,
    75
    ,
    100
    ,
    125
    ,
    150
    ,
    200
    ,
    250
    ,
    300
    ,
    350
    ,
    400
    ,
    450
    49315K7100000049315K9700000049315K94000000
    3/8
    Bottom6003/4"-20
    Top2 5/8"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 165
    22
    ,
    35
    ,
    50
    ,
    75
    ,
    100
    ,
    125
    ,
    150
    ,
    200
    ,
    250
    ,
    300
    ,
    350
    ,
    400
    ,
    450
    49315K720000049315K980000049315K9400000
    1/2
    Bottom6003/4"-20
    Top2 13/16"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 165
    22
    ,
    35
    ,
    50
    ,
    75
    ,
    100
    ,
    125
    ,
    150
    ,
    200
    ,
    250
    ,
    300
    ,
    350
    ,
    400
    ,
    450
    49315K730000049315K980000049315K9600000
     

    Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Pressure-Regulating Valves for Cryogenic Liquids.
    These valves can withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Brass Body—Bronze Diaphragm and PTFE Seal
    1/4
    Side6001/4
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    15 to 65
    ,
    75 to 175
    ,
    100 to 250
    47435K310000000
    3/8
    Side6003/8
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    15 to 65
    ,
    75 to 175
    ,
    100 to 250
    47435K32000000
     

    Vacuum Breakers for Chemicals

    A plastic body withstands pH neutralizing, cleaning, and plating solutions containing sodium hydroxide, methyl ethyl ketone, and other harsh chemicals. Also known as vacuum-breaking valves, these valves have vents that open when pressure drops to relieve vacuum conditions and prevent backward suction from drawing liquid into upstream piping.
    Diaphragm Check Valve
    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers for Chemicals.
    Material
    CPVC Body
    PVC Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    For Pipe
    Schedule
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Min. Opening
    Pressure, psi
    End-to-End
    Lg.
    Seal
    DIaphragm
    For Use With
    Temp. Range,
    ° F
    Color
    Each
    Temp. Range,
    ° F
    Color
    Each
    NPT Female Inlet × NPT Female Outlet
    1/2
    1/2
    80
    Not Rated100 psi @ 75° F14 5/16"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N13000000040 to 140Gray1868N10000000
    3/4
    3/4
    80
    Not Rated100 psi @ 75° F14 5/8"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N1400000040 to 140Gray1868N11000000
    1
    1
    80
    Not Rated100 psi @ 75° F15 1/8"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N1500000040 to 140Gray1868N12000000
     
    Spring-Loaded Piston Check Valve
    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers for Chemicals.
    Material
    CPVC Body
    PVC Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    For Pipe
    Schedule
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Min. Opening
    Pressure, psi
    End-to-End
    Lg.
    Seal
    Piston
    Spring
    For Use With
    Temp. Range,
    ° F
    Color
    Each
    Temp. Range,
    ° F
    Color
    Each
    NPT Female Inlet × NPT Female Outlet
    1 1/2
    1 1/2
    80
    Not Rated100 psi @ 75° F17 15/16"Fluoroelastomer
    CPVC
    PolymerBeverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N180000000———0
    2
    2
    80
    Not Rated100 psi @ 75° F18 1/2"Fluoroelastomer
    PVC
    PolymerBeverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon———040 to 140Gray1868N170000000
     

    High-Purity Tank-Mount Pressure-Regulating Valves for Inert Gas

    Reduce contaminants in research sample systems, emission monitoring systems, chromatography, and other high-purity applications that use argon, helium, nitrogen, or carbon dioxide. These valves have a 316 stainless steel and brass body with a smooth finish to reduce dust collection and internal components designed to protect the seal and diaphragm from contamination. They automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Outlet fittings are Swagelok® for a leak-free seal around hard metal tubing in high-pressure lines. Also known as instrumentation fittings, Swagelok® fittings are compatible with Parker A-Lok, Gyrolok, Bilok, and Tylok fittings. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    For Carbon Dioxide
    Image of Product. Swagelok® Female Outlet × NGO Female Inlet (Brass). Front orientation. Pressure-Regulating Valves. High-Purity Tank-Mount Pressure-Regulating Valves for Inert Gas, Female Inlet, Female Outlet, Brass Body.
    Image of Product. Swagelok® Female Outlet × NGO Female Inlet (Chrome-Plated Brass). Front orientation. Pressure-Regulating Valves. High-Purity Tank-Mount Pressure-Regulating Valves for Inert Gas, Female Inlet, Female Outlet, Chrome-Plated Brass Body.

    Swagelok® Female Outlet ×

    NGO Female Inlet (Brass)

    Swagelok® Female Outlet ×

    NGO Female Inlet

    (Chrome-Plated Brass)

    Chrome-Plated Brass Body—Chrome-plated valves add a layer of corrosion resistance.
    Single Stage—Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
    Two Stage—Two-stage valves progressively reduce pressure over two steps for more consistent outlet pressure at all times. They’re often used in applications that require a constant outlet pressure regardless of the tank level.
    Inlet
    Outlet
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    No. of
    Stages
    For Tube
    OD
    Location
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Temp. Range,
    ° F
    Each
    NGO Female Inlet × Swagelok® Female Outlet
     
    Brass Body—316 Stainless Steel Diaphragm and PTFE Seal
    320
    SideRight Hand
    0 to 4,000Single1/4"Side0 to 15Knob-20 to 1207951A720000000
    320
    SideRight Hand
    0 to 4,000Single1/4"Side0 to 125Knob-20 to 1207951A73000000
    320
    SideRight Hand
    0 to 4,000Two1/4"Side0 to 125Knob-20 to 1207951A69000000
     
    Chrome-Plated Brass Body—316 Stainless Steel Diaphragm and PTFE Seal
    320
    SideRight Hand
    0 to 4,000Single1/4"Side0 to 15Knob-20 to 1207951A63000000
    320
    SideRight Hand
    0 to 4,000Single1/4"Side0 to 50Knob-20 to 1207951A34000000
    320
    SideRight Hand
    0 to 4,000Two1/4"Side0 to 15Knob-20 to 1207951A66000000
    320
    SideRight Hand
    0 to 4,000Two1/4"Side0 to 50Knob-20 to 1207951A67000000
    320
    SideRight Hand
    0 to 4,000Two1/4"Side0 to 125Knob-20 to 1207951A68000000
     

    Vacuum-Regulating Valves for Air and Inert Gas

    Image of Product. Front orientation. Vacuum-Regulating Valves. Vacuum-Regulating Valves for Air and Inert Gas.
    Throttle a high vacuum source to maintain a lower vacuum level in your system. Adjust the outlet vacuum level within the range. All valves have a gauge port.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Pipe
    Size
    Location
    Vacuum Range,
    in. Hg
    Vacuum Adjustment
    Method
    Vacuum Gauge
    Included
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Each
    NPT Female
     
    Brass Body—EPM Rubber Diaphragm and Buna-N Seal
    1/4
    Bottom1/4
    Side0 to 15ScrewNo1 3/4"Air, Carbon Dioxide, Inert Gas, Nitrogen-20 to 1805021K140000000
    1/4
    Bottom1/4
    Side10 to 30ScrewNo1 3/4"Air, Carbon Dioxide, Inert Gas, Nitrogen-20 to 1805021K24000000
     

    Tank-Mount Pressure-Regulating Valves for Cryogenic Cylinders

    Image of Product. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Cryogenic Cylinders.
    Automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. These valves can remove gases from liquid cryogenic cylinders. They have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves come with a gauge to monitor outlet pressure. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    Inlet
    Outlet
    For Use With
    CGA
    No.
    Location
    Thread
    Direction
    No. of
    Stages
    Thread
    Size
    Location
    Thread
    Direction
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Temp. Range,
    ° F
    Each
    UNF Male Outlet × NGO Female Inlet
     
    Brass Body—Stainless Steel Diaphragm and PTFE Seal
    Carbon Dioxide320
    SideRight Hand
    Single9/16"-18
    BottomRight Hand
    0 to 350T-Handle-20 to 1207897A830000000
     

    Easy-Read Tank-Mount Pressure-Regulating Valves with Flowmeter for Inert Gas

    Flowmeters let you see the gas flow rate from a distance. These valves automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. They have a gauge for monitoring inlet pressure from the tank.
    For Argon and Argon/Carbon Dioxide Blend
    Image of Product. Male Inlet × Female Outlet With One Flowmeter. Front orientation. Pressure-Regulating Valves. Easy-Read Tank-Mount Pressure-Regulating Valves with Flowmeter for Inert Gas, Female Outlet, Male Inlet, UNF Outlet Thread, Single Stage, 1 Flowmeter.

    Male Inlet × Female

    Outlet With One

    Flowmeter

    Single Stage—Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
    1 Flowmeter—Valves with one flowmeter are for one piece of equipment on a tank. The flowmeter has a single scale.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    No. of
    Stages
    Thread
    Size
    Location
    Thread
    Direction
    Flow Range
    No. of
    Flowmeters
    Body
    Seal
    Diaphragm
    Each
    UNF Female Outlet × NGO Male Inlet
    580
    SideRight Hand
    0 to 3,000Single5/8"-18
    SideRight Hand
    0 to 70 scfh (Argon), 0 to 70 scfh (Argon/Carbon Dioxide Blend)1BrassPTFENeoprene78595A50000000
     
    Valve Union Fittings
    For Argon, Argon/Carbon Dioxide Blend, and Helium
    Two Stage—Two-stage valves progressively reduce pressure over two steps for more consistent outlet pressure at all times. They’re often used in applications that require a constant outlet pressure regardless of the tank level.
    1 Flowmeter—Valves with one flowmeter are for one piece of equipment on a tank. The flowmeter has a single scale.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    No. of
    Stages
    Thread
    Size
    Location
    Thread
    Direction
    Flow Range
    No. of
    Flowmeters
    Body
    Seal
    Diaphragm
    Each
    UNF Female Outlet × NGO Male Inlet
    580
    SideRight Hand
    0 to 3,000Two5/8"-18
    SideRight Hand
    0 to 40 scfh (Argon), 0 to 40 scfh (Argon/Carbon Dioxide Blend), 0 to 150 scfh (Helium)1BrassPTFENeoprene78595A4950000000
     
    Valve Union Fittings
    For Argon, Argon/Carbon Dioxide Blend, Carbon Dioxide, and Helium
    Image of Product. Male Inlet × Female Outlet With One Flowmeter. Front orientation. Pressure-Regulating Valves. Easy-Read Tank-Mount Pressure-Regulating Valves with Flowmeter for Inert Gas, Female Outlet, Male Inlet, UNF Outlet Thread, Single Stage, 1 Flowmeter.

    Male Inlet × Female

    Outlet With One

    Flowmeter

    Single Stage—Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
    1 Flowmeter—Valves with one flowmeter are for one piece of equipment on a tank. The flowmeter has a single scale.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    No. of
    Stages
    Thread
    Size
    Location
    Thread
    Direction
    Flow Range
    No. of
    Flowmeters
    Body
    Seal
    Diaphragm
    Each
    UNF Female Outlet × NGO Male Inlet
    580
    SideRight Hand
    0 to 4,000Single5/8"-18
    SideRight Hand
    0 to 60 scfh (Argon)
    0 to 60 scfh (Argon/Carbon Dioxide Blend)
    0 to 50 scfh (Carbon Dioxide)
    0 to 160 scfh (Helium)
    1BrassBuna-NBrass78595A3940000000
     
    Valve Union Fittings
    For Carbon Dioxide
    Image of Product. Female Inlet × Female Outlet With One Flowmeter. Front orientation. Pressure-Regulating Valves. Easy-Read Tank-Mount Pressure-Regulating Valves with Flowmeter for Inert Gas, Female Outlet, UNF Outlet Thread, Female Inlet, Single Stage, 1 Flowmeter.

    Female Inlet ×

    Female Outlet With

    One Flowmeter

    Single Stage—Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
    1 Flowmeter—Valves with one flowmeter are for one piece of equipment on a tank. The flowmeter has a single scale.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    No. of
    Stages
    Thread
    Size
    Location
    Thread
    Direction
    Flow Range
    No. of
    Flowmeters
    Body
    Seal
    Diaphragm
    Each
    UNF Female Outlet × NGO Female Inlet
    320
    SideRight Hand
    0 to 4,000Single5/8"-18
    SideRight Hand
    0 scfh to 70 scfh1BrassPTFENeoprene78595A460000000
     
    Valve Union Fittings

    Tank-Mount Pressure-Regulating Valves with Flowmeter for Inert Gas

    Commonly used in TIG welding where gas flow/coverage is a concern, these valves measure the gas flow rate in addition to regulating pressure. They automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves have a gauge to monitor the outlet flow rate and a second gauge to monitor inlet pressure from the tank. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
    For Carbon Dioxide
    Image of Product. Female Outlet × Female Inlet. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves with Flowmeter for Inert Gas, Female Outlet, UNF Outlet Thread, Female Inlet, Single Stage, Brass Body, Neoprene Diaphragm.
    Image of Product. Female Outlet × Female Inlet with Hose. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves with Flowmeter for Inert Gas, Female Outlet, UNF Outlet Thread, Female Inlet, Single Stage, Brass Body, Neoprene Diaphragm, 10-ft. long, 3/16" dia. hose with 5/8"-18 male fittings on both ends.

    Female Outlet × Female

    Inlet

    Female Outlet × Female Inlet with Hose

    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    No. of
    Stages
    Thread
    Size
    Location
    Thread
    Direction
    Flow Range,
    scfh
    Flow Gauge
    Included
    Body
    Seal
    Diaphragm
    Includes
    Temp. Range,
    ° F
    Each
    UNF Female Outlet × NGO Female Inlet
    320
    SideRight Hand
    0 to 4,000Single5/8"-18
    SideRight Hand
    0 to 60YesBrassPTFENeoprene-20 to 1207997A660000000
    320
    SideRight Hand
    0 to 4,000Single5/8"-18
    SideRight Hand
    0 to 60YesBrassPTFENeoprene10-ft. long, 3/16" dia. hose with 5/8"-18 male fittings on both ends-20 to 1207997A68000000
    320
    SideRight Hand
    0 to 4,000Single5/8"-18
    SideRight Hand
    0 to 100YesBrassPTFENeoprene-20 to 1207997A51000000
     
    back to top