    67 Products

    Panel-Mount Equipment Circuit Breakers

    Mount these breakers, also known as supplemental protectors, through panels downstream from a branch circuit breaker to protect a single piece of equipment. These breakers can also be used as on/off switches. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    Push-Button Style—Screw-On Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Push Button Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Mounting
    Holes
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    No.
    of
    Dia.
    Mounting Fasteners
    Included
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T41000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4400000
     
    2 Poles
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5100000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5400000
     
    Circuit Breaker Covers
    Rocker-Switch Style—Snap-In Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Rocker Switch Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T11000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1400000
     
    2 Poles
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2100000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2400000
     
    Circuit Breaker Covers
    Toggle-Switch Style—Screw-On Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Toggle Switch Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For Panel
    Cutout Dia.
    Dp. Behind
    Panel
    Mounting Fasteners
    Included
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    1/2075V DC
    250V AC
    50/60200 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T11000000
    2/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1200000
    4/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1300000
    1/275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1400000
    6/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1500000
    8/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1600000
    175V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1700000
    1 1/275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1800000
    275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1900000
    2 1/275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2100000
    375V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2200000
    475V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2300000
    575V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2400000
    675V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2500000
    875V DC
    250V AC
    50/602,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2600000
    1075V DC
    250V AC
    50/602,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2700000
     

    Harsh-Environment Circuit Breakers

    Built to resist vibration and corrosion in harsh environments, these circuit breakers protect against overload and short circuits in low-voltage automotive and other electronic applications. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    Lever Manual Reset and Push-Pull Button Manual Reset—Push-pull button and lever style breakers can be used as an on/off switch.
    UL 1077—Place UL 1077-rated breakers downstream from a branch circuit breaker to protect a single piece of equipment. They are also known as supplemental protectors.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Mounting
    Holes
    Screw On
    Current,
    A
    Voltage,
    V DC
    Breakthrough Current
    @ Voltage
    For Panel
    Cutout Dia.
    Dp. Behind
    Panel
    Mounting
    Location
    No.
    of
    Dia.
    Mounting Fasteners
    Included
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole—Push-Pull-Button Style
    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Push-Pull-Button Style.
     
    Thermal
    30286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T11000000
    35286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1200000
    40286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1300000
    45286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1400000
    50 286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1500000
    55286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1600000
    60286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1700000
    70286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1800000
    80286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1900000
    90286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T2100000
     
    1 Pole—Lever Style
    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Lever Style.
     
    Thermal
    30481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22200000
    40481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22300000
    50 481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22400000
    60481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22500000
    70481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22600000
    80481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22700000
    100481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22800000
    120481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22900000
    135481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K23100000
    150481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K23200000
     
    1 Pole—Push-Button Style
    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Push-Button Style.
     
    Thermal
    30481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13100000
    40481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13200000
    50 481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13300000
    60481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13400000
    70481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13500000
    80481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13600000
    90481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13700000
    100481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13800000
    120481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13900000
    135481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K14100000
    150481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K14200000
     

    IEC Connectors

    Pair these connectors with standard IEC power cords to bring power into or out of devices. Often used to convey power from wall outlets, there’s no need to wire your devices to an external power source. Instead, wire these connectors into your device with the terminals on the back of each connector.
    Some connectors accept a fuse (not included), which prevents short circuits and circuit overloads from damaging your device.
    Mate plugs and sockets with receptacles of the opposite gender. Plugs and sockets cannot mate with each other.
    Male Receptacles with On/Off Switch and Circuit Breaker
    Image of Product. Screw On. Front orientation. Power Connectors. IEC Connectors, Male Receptacles with On/Off Switch and Circuit Breaker, Screw On, Single—Unshielded.

    Screw On

    IEC Connector
    Type
    Switch
    Designation
    Voltage,
    V AC
    Current (Rating),
    amp
    Circuit Breaker
    Current, amp
    Wire Connection
    Color
    Shock Protection
    Class
    Certification
    Each
    Screw On
     
    Single—Unshielded
    C14DPST-NO
    25015 (UL), 10 (IEC)10Quick-Disconnect TerminalBlackIC-UL Recognized Component, CE Marked, ENEC Marked, UL Recognized Component
    4940N111000000
    C14DPST-NO
    25015 (UL), 10 (IEC)15Quick-Disconnect TerminalBlackIC-UL Recognized Component, CE Marked, ENEC Marked, UL Recognized Component
    4940N11200000
     
    back to top