    Panel-Mount Equipment Circuit Breakers

    Mount these breakers, also known as supplemental protectors, through panels downstream from a branch circuit breaker to protect a single piece of equipment. These breakers can also be used as on/off switches. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    Push-Button Style—Screw-On Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Push Button Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Mounting
    Holes
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    No.
    of
    Dia.
    Mounting Fasteners
    Included
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T41000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4400000
     
    2 Poles
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5100000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5400000
     
    Circuit Breaker Covers
    Rocker-Switch Style—Snap-In Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Rocker Switch Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T11000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1400000
     
    2 Poles
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2100000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2400000
     
    Circuit Breaker Covers
    back to top