McMaster-Carr logo
    Filter by
    Environment
    System of Measurement
    Inlet Pipe Size
    Industrial Info Compare
    Outlet Pipe Size
    Industrial Info Compare
    For Removing
    Manufacturer
    Bowl Type
    Inlet Thread Type
    Gauge Included
    Maximum Pressure
    Outlet Thread Type
    Drain Type
    Removes Particle Size Down To
    Bowl Material
    Maximum Pressure Regulation
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Compare
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    26 Products
    About Air Preparation
    industrial info icon

    Customize your air preparation system with dryers, filters, and other purifying parts.

    Clean Room Compressed Air Filters for Particle Removal

    Image of Product. Front orientation. Compressed Air Filters. Clean Room Compressed Air Filters for Particle Removal.
    Assembled, inspected, and packaged in a clean environment, these filters come sealed in antistatic double bags. They extend the service life of air-powered tools and equipment by removing particles and water droplets from compressed air. A clear bowl lets you see inside to monitor contents. Run a tube from the open drain port to a disposal point such as a drain pan or waste system.
    Pipe
    Size
    Drain
    Overall
    Inlet
    Outlet
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Removes Particle
    Size Down To, μm
    Pipe
    Size
    Thread
    Type
    Gender
    Includes
    Ht.
    Wd.
    Clean Room Std.
    Each
    NPT Female Inlet × NPT Female Outlet
     
    Polycarbonate Bowl—Clear with Manual Drain
    1/8
    1/8
    53 scfm @ 100 psi14551/8
    NPT
    FemaleMounting Bracket4 3/8"1 5/8"Fed. Std. Class 1, ISO Class 3
    8756N121000000
    1/4
    1/4
    128 scfm @ 100 psi14551/4
    NPT
    FemaleMounting Bracket5 3/4"2 1/8"Fed. Std. Class 1, ISO Class 3
    8756N12200000
    3/8
    3/8
    128 scfm @ 100 psi14551/4
    NPT
    FemaleMounting Bracket5 3/4"2 1/8"Fed. Std. Class 1, ISO Class 3
    8756N12300000
    1/2
    1/2
    206 scfm @ 100 psi14551/4
    NPT
    FemaleMounting Bracket7 1/8"2 3/4"Fed. Std. Class 1, ISO Class 3
    8756N12400000
    3/4
    3/4
    212 scfm @ 100 psi14551/4
    NPT
    FemaleMounting Bracket7 1/4"3"Fed. Std. Class 1, ISO Class 3
    8756N12500000
    1
    1
    427 scfm @ 100 psi14551/4
    NPT
    FemaleMounting Bracket10 1/4"3 5/8"Fed. Std. Class 1, ISO Class 3
    8756N12600000
     

    Clean Room Compressed Air Filter/Regulators for Particle Removal

    Image of Product. Front orientation. Compressed Air Filter/Regulators. Clean Room Compressed Air Filter/Regulators for Particle Removal.
    Assembled, inspected, and packaged in a clean environment, these filter/regulators come sealed in antistatic double bags. The filter and regulator are joined top-to-bottom to fit in the same space as a filter alone. They provide clean compressed air at your required pressure. The filter has a clear bowl, so you can see inside to monitor contents from every direction. The regulator is relieving style, so it exhausts when the downstream pressure exceeds the set pressure. Run a tube from the open drain port to a disposal point, such as a drain pan or waste system.
    Filter/Regulators
    Replacement Elements
    for Particle Removal
    Pipe
    Size
    Drain
    Overall
    Inlet
    Outlet
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Removes Particle
    Size Down To, μm
    Pipe
    Size
    Thread
    Type
    Gender
    Pressure Regulation
    Range, psi
    Includes
    Wd.
    Ht.
    Clean Room Std.
    Each
    Each
    NPT Female Inlet × NPT Female Outlet
     
    Polycarbonate Bowl—Clear with Manual Drain
    1/8
    1/8
    70 scfm @ 100 psi14551/8
    NPT
    Female7.25 to 123Mounting Bracket1 5/8"6 1/4"Fed. Std. Class 1, ISO Class 3
    8223N11000000———0
    1/4
    1/4
    123 scfm @ 100 psi14551/4
    NPT
    Female7.25 to 123Mounting Bracket2 1/8"8"Fed. Std. Class 1, ISO Class 3
    8223N1200000———0
    3/8
    3/8
    123 scfm @ 100 psi14551/4
    NPT
    Female7.25 to 123Mounting Bracket2 1/8"8"Fed. Std. Class 1, ISO Class 3
    8223N1300000———0
    1/2
    1/2
    229 scfm @ 100 psi14551/4
    NPT
    Female7.25 to 123Mounting Bracket2 3/4"9 3/8"Fed. Std. Class 1, ISO Class 3
    8223N1400000———0
    3/4
    3/4
    229 scfm @ 100 psi14551/4
    NPT
    Female7.25 to 123Mounting Bracket3"9 1/2"Fed. Std. Class 1, ISO Class 3
    8223N1500000———0
    1
    1
    564 scfm @ 100 psi14551/4
    NPT
    Female7.25 to 123Mounting Bracket3 3/4"15 3/8"Fed. Std. Class 1, ISO Class 3
    8223N160000009891K12000000
     
    Replacement Elements

    Clean Room Disposable Masks

    Image of Product. Front orientation. Masks. Clean Room Disposable Masks.
    Made of low-linting fabric, these masks won’t shed fabric particles that could contaminate your clean room. They come double bagged and are suitable for use in clean rooms rated to both Federal Standard and ISO classes. In both systems, clean rooms with lower class ratings have fewer contaminants. Toss these masks out after each use so you’re always wearing a fresh mask. They fit tight around your face to prevent contaminants from escaping—just pinch the nosepiece.
    Clean Room Std.
    Securing
    Method
    Strap
    Location
    Clothing
    Size
    Color
    Features
    Pkg.
    Qty.
    Pkg.
    Cellulose/Polyester Fabric
    Fed. Std. Class 100, ISO Class 5
    Elastic StrapEarOne SizeLight BlueAdjustable Nosepiece506681N14000000
     
    Polyethylene Fabric
    Fed. Std. Class 1, ISO Class 3
    Elastic StrapEarOne SizeWhiteAdjustable Nosepiece506681N1200000
     

    Bench-Top Hood Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Bench-Top Hood Air Purifiers.
    Image of Product. Front orientation. Air Purifier Prefilters.
    Image of Product. Front orientation. Air Purifier Filters.

    Replacement Prefilters

    Replacement Filters

    Filtering away dust and particles, these hoods create a clean space for demanding work, such as bioprocessing, pharmaceuticals, electronics, and optics. They have a HEPA H14 filter to catch 99.995% of particles down to 0.1 microns, as well as a prefilter to pull out large particles before they reach the HEPA filter. To draw air from outside the hood into the filters, they have a fan; there’s no need to connect them to ductwork. A flow monitor tracks the airflow and alerts you with a visible and audible alarm if the fan fails. They meet Fed. Std. Class 100 and ISO Class 5 clean room requirements.
    As an alternative to filtering the air of an entire room, these hoods leave a large enough opening for comfortable access inside and have internal fluorescent lighting to help you see your work. Their work surface is 304L stainless steel, which resists bacteria and chemicals, and also is easy to clean. Mount them on workbenches and carts that are designed to hold them, or place them on your own bench top.
    Purifiers
    Replacement
    Prefilters
    Replacement
    Filters
    Overall
    Work
    Surface
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Voltage,
    V AC
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Wd.
    Dp.
    Material
    Color
    Panel Cutout
    Dia.
    Clean Room Std.
    Each
    Each
    Each
    304L Stainless Steel Work Surface with Acrylic Plastic Enclosure
    18559 dBA @ 5 ft.120347 3/4"31 3/4"24 1/4"26 1/2"20 1/2"PlasticWhite, Black, Blue2 7/8"Fed. Std. Class 100, ISO Class 5
    3944N110000000003944N140000003944N130000000
     
    Carts

    Gasketed Ceiling Tiles

    Image of Product. Front orientation. Contains Border. Ceiling Tiles. Gasketed Ceiling Tiles, Smooth, Flush Edge.
    Image of Product. Front orientation. Contains Border. Ceiling Tiles. Gasketed Ceiling Tiles, Smooth, Recessed Edge.

    Smooth

    Flush Edge

    Smooth

    Recessed Edge

    Block air and dust from seeping through your drop ceiling grid to help improve air quality and maintain room temperature. These tiles have a gasket around the edge to seal out contaminants. Rated for Fed. Spec. Class 100 and ISO Class 5 clean rooms, they are often used in labs and healthcare facilities. They also absorb 80% of sound to keep workspaces quiet. Coated in thick latex paint, they stand up to bumps and scrapes.
    Recessed Edge—Tiles with recessed edges are indented on all four edges so the installed tile face extends below the support framing.
    Lg.,
    ft.
    Wd.,
    ft.
    Thk.
    Edge
    Wd.
    Sound
    Absorbed
    Material
    Color
    Seal Material
    Flammability
    Rating
    Clean Room Std.
    Pkg.
    Qty.
    Pkg.
    Smooth
     
    Flush Edge
    221"80%Mineral FiberWhitePolyethylene FoamNFPA 101 Class A
    Fed. Std. Class 100, ISO Class 5
    106796N110000000
    421"80%Mineral FiberWhitePolyethylene FoamNFPA 101 Class A
    Fed. Std. Class 100, ISO Class 5
    66796N12000000
     
    Recessed Edge
    221"5/16"80%Mineral FiberWhitePolyethylene FoamNFPA 101 Class A
    Fed. Std. Class 100, ISO Class 5
    106796N13000000
    421"5/16"80%Mineral FiberWhitePolyethylene FoamNFPA 101 Class A
    Fed. Std. Class 100, ISO Class 5
    66796N14000000
     
    back to top