McMaster-Carr logo
    Filter by
    Pipe Size
    Industrial Info Compare
    Valve Position
    Thread Type
    Industrial Info Compare
    Fitting Connection
    Industrial Info Compare
    Connects To
    Conduit Trade Size
    Industrial Info Compare
    Export Control Classification Number (ECCN)
    Industrial Info Compare
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Compare
    DFARS Specialty Metals
    For Use Outdoors
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    152 Products
    About Actuated On/Off Valves
    industrial info icon

    Choose the right automatic on/off valve based on power source, pressure, and flow rate.

    Compact Solenoid On/Off Valves

    Lower profile and available in smaller connection sizes than standard valves, these fit in tight spots. They operate on electricity to automatically start and stop flow.
    Valves are fail closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Brass Body with DIN A Connection—Buna-N Seal
    Image of Product. Back orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves, Brass Body with DIN A Connection—Buna-N Seal.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    For Use With
    Each
    Fail Closed—24V AC
    1/4
    FemaleNPT
    0.3548 psi @ 140° FZero Pressure Drop, Solenoid15 to 1901 9/16"3 3/16"Air
    Argon
    Helium
    Krypton
    Neon
    Water
    Xenon
    8077K2460000000
    1/4
    FemaleNPT
    0.58110 psi @ 140° FZero Pressure Drop, Solenoid15 to 1901 9/16"3 3/16"Air
    Argon
    Helium
    Krypton
    Neon
    Water
    Xenon
    8077K236000000
     
    Fail Closed—24V DC
    1/4
    FemaleNPT
    0.21285 psi @ 131° FZero Pressure Drop, Solenoid32 to 1801 9/16"3"Air
    Argon
    Deionized Water
    Helium
    Nitrogen
    Xenon
    8077K219000000
    1/4
    FemaleNPT
    0.3520 psi @ 140° FZero Pressure Drop, Solenoid15 to 1901 9/16"3 3/16"Air
    Argon
    Helium
    Krypton
    Neon
    Water
    Xenon
    8077K247000000
    1/4
    FemaleNPT
    0.5855 psi @ 140° FZero Pressure Drop, Solenoid15 to 1901 9/16"3 3/16"Air
    Argon
    Helium
    Krypton
    Neon
    Water
    Xenon
    8077K237000000
     
    Fail Closed—120V AC
    1/4
    FemaleNPT
    0.3548 psi @ 140° FZero Pressure Drop, Solenoid15 to 1901 9/16"3 3/16"Air
    Argon
    Helium
    Krypton
    Neon
    Water
    Xenon
    8077K245000000
    1/4
    FemaleNPT
    0.58110 psi @ 140° FZero Pressure Drop, Solenoid15 to 1901 9/16"3 3/16"Air
    Argon
    Helium
    Krypton
    Neon
    Water
    Xenon
    8077K235000000
     
    Brass Body with DIN BI Connection—Buna-N Seal
    Image of Product. Back orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves, Brass Body with DIN BI Connection—Buna-N Seal.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    For Use With
    Each
    Fail Closed—24V AC
    1/4
    FemaleNPT
    0.29100 psi @ 140° FZero Pressure Drop, Solenoid15 to 1901 11/16"2 9/16"Air
    Argon
    Helium
    Krypton
    Neon
    Water
    Xenon
    8077K226000000
     
    Fail Closed—24V DC
    1/4
    FemaleNPT
    0.2950 psi @ 140° FZero Pressure Drop, Solenoid15 to 1901 11/16"2 9/16"Air
    Argon
    Helium
    Krypton
    Neon
    Water
    Xenon
    8077K22700000
     
    Fail Closed—120V AC
    1/4
    FemaleNPT
    0.29100 psi @ 140° FZero Pressure Drop, Solenoid15 to 1901 11/16"2 9/16"Air
    Argon
    Helium
    Krypton
    Neon
    Water
    Xenon
    8077K22500000
     
    Brass Body with Wire Lead Connection—Buna-N Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves, Brass Body with Wire Lead Connection—Buna-N Seal.
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves, Brass Body with Wire Lead Connection—Buna-N Seal.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Repair Kits
    Solenoid Coils
    Valve
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Lg.
    Dia.
    Overall
    Ht.
    For Use With
    Enclosure
    Rating
    Certification
    Each
    Each
    Each
    Fail Closed—24V AC
    1/4
    FemaleNPT
    0.35140 psi @ 70° FZero Pressure Drop, Solenoid35 to 1201 1/4"3"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4X
    UL Listed, CSA Certified
    8077K52200000002895N120000002894N15000000
    3/8
    FemaleNPT
    0.72100 psi @ 100° FZero Pressure Drop, Solenoid35 to 1201 7/8"3 1/4"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4X
    UL Listed, CSA Certified
    8077K5320000002895N14000002894N2400000
     
    Fail Closed—24V DC
    1/4
    FemaleNPT
    0.3560 psi @ 70° FZero Pressure Drop, Solenoid35 to 1201 1/2"3"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    IP69
    UL Listed, C-UL Listed, CE Marked, CSA Certified
    8077K5210000002895N42000002894N2300000
    3/8
    FemaleNPT
    0.7225 psi @ 70° FZero Pressure Drop, Solenoid35 to 1201 1/2"3 1/4"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    IP69
    UL Listed, C-UL Listed, CE Marked, CSA Certified
    8077K5310000002895N42000002894N1400000
     
    Fail Closed—120V AC
    1/4
    FemaleNPT
    0.35140 psi @ 70° FZero Pressure Drop, Solenoid35 to 1201 1/4"3"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4X
    UL Listed, CSA Certified
    8077K5230000002895N150000002894N1600000
    3/8
    FemaleNPT
    0.72100 psi @ 100° FZero Pressure Drop, Solenoid35 to 1201 7/8"3 1/4"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4X
    UL Listed, CSA Certified
    8077K5330000002895N170000002894N2500000
     
    Brass Body with Wire Lead Connection—Synthetic Ruby Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves, Brass Body with Wire Lead Connection—Synthetic Ruby Seal.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    For Use
    With
    Enclosure
    Rating
    Certification
    Each
    Each
    Fail Closed—24V AC
    1/8
    FemaleNPT
    0.24500 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K31200000002894N18000000
    1/4
    FemaleNPT
    0.111,100 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3220000002894N1800000
    1/4
    FemaleNPT
    0.17700 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3320000002894N1800000
    1/4
    FemaleNPT
    0.31365 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3520000002894N1800000
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.24175 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3130000002894N1900000
    1/4
    FemaleNPT
    0.11435 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3230000002894N1900000
    1/4
    FemaleNPT
    0.24175 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3430000002894N1900000
    1/4
    FemaleNPT
    0.31125 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3530000002894N1900000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.24500 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3110000002894N1800000
    1/4
    FemaleNPT
    0.111,100 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3210000002894N1800000
    1/4
    FemaleNPT
    0.17700 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3310000002894N1800000
    1/4
    FemaleNPT
    0.24500 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3410000002894N1800000
    1/4
    FemaleNPT
    0.31365 psi @ 70° FZero Pressure Drop, Solenoid35 to 2101 9/16"3 1/8"OilNEMA 4X
    UL Listed, CSA Certified
    46365K3510000002894N1800000
     
    303 Stainless Steel Body with Wire Lead Connection—Buna-N Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves, 303 Stainless Steel Body with Wire Lead Connection—Buna-N Seal.
    303 stainless steel valves are more corrosion resistant than brass valves.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Dia.
    Overall
    Ht.
    For Use With
    Enclosure
    Rating
    Certification
    Each
    Each
    Fail Closed—24V DC
    1/4
    FemaleNPT
    0.06500 psi @ 70° FZero Pressure Drop, Solenoid35 to 1201 9/16"3"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4, NEMA 4X
    UL Listed, C-UL Listed
    8214K51300000002894N23000000
    1/4
    FemaleNPT
    0.17125 psi @ 70° FZero Pressure Drop, Solenoid35 to 1201 9/16"3"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4, NEMA 4X
    UL Listed, C-UL Listed
    8214K5230000002894N2300000
    1/4
    FemaleNPT
    0.540 psi @ 70° FZero Pressure Drop, Solenoid35 to 1201 9/16"3 1/8"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4, NEMA 4X
    UL Listed, C-UL Listed
    8214K5310000002894N1400000
    1/4
    FemaleNPT
    0.8515 psi @ 70° FZero Pressure Drop, Solenoid35 to 1201 9/16"3"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4, NEMA 4X
    UL Listed, C-UL Listed
    8214K5410000002894N2300000
     
    Fail Closed—120V AC
    1/4
    FemaleNPT
    0.06500 psi @ 70° FZero Pressure Drop, Solenoid35 to 1801 9/16"3"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4, NEMA 4X
    UL Listed, C-UL Listed
    8214K5110000002894N1600000
    1/4
    FemaleNPT
    0.17160 psi @ 70° FZero Pressure Drop, Solenoid35 to 1801 9/16"3"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4, NEMA 4X
    UL Listed, C-UL Listed
    8214K5210000002894N1600000
    1/4
    FemaleNPT
    0.5145 psi @ 70° FZero Pressure Drop, Solenoid35 to 1801 9/16"3 1/8"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4, NEMA 4X
    UL Listed, C-UL Listed
    8214K5320000002894N1200000
    1/4
    FemaleNPT
    0.8540 psi @ 70° FZero Pressure Drop, Solenoid35 to 1801 9/16"3"Air
    Argon
    Helium
    Krypton
    Neon
    Oil
    Water
    Xenon
    NEMA 4, NEMA 4X
    UL Listed, C-UL Listed
    8214K5430000002894N1600000
     

    Compact Solenoid On/Off Valves with Exhaust Port

    Image of Product. Brass Body. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves with Exhaust Port, Brass Body, Wire Lead Connection.
    Image of Product. 430 Stainless Steel Body. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves with Exhaust Port, Wire Lead Connection, 430 Stainless Steel Body.

    Brass Body

    430 Stainless

    Steel Body

    To fit in tight spots, these valves have a slimmer body than standard valves with an exhaust port. Often used to control single-acting, spring-return air cylinders, they have a third threaded port to exhaust media. Valves operate on electricity to automatically start and stop flow.
    They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    430 Stainless Steel Body—430 stainless steel valves are more corrosion resistant than brass valves.
    Fail-Closed Valve—Fail closed valves exhaust media unless actuated; when actuated, they close the exhaust port and reverse the direction of flow to send media to equipment.
    Fail-Open Valve—Fail open valves send media to equipment unless actuated; when actuated, they open the exhaust port and reverse the direction of flow to exhaust media.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Solenoid Coils
    Valve
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Seal
    Material
    Lg.
    Dia.
    Overall
    Ht.
    No. of
    Ports
    Enclosure
    Rating
    Certification
    Each
    Each
    Brass Body with Wire Lead Connection and Side Exhaust Port
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.05200 psi @ 70° FZero Pressure Drop, Solenoid35 to 180Buna-N
    1 3/16"2 1/8"3NEMA 4X
    UL Listed, CSA Certified
    8111K3310000000———0
    1/8
    FemaleNPT
    0.09100 psi @ 70° FZero Pressure Drop, Solenoid35 to 180Buna-N
    1 3/16"2 1/8"3NEMA 4X
    UL Listed, CSA Certified
    8111K611000000———0
    1/8
    FemaleNPT
    0.2140 psi @ 70° FZero Pressure Drop, Solenoid35 to 180Buna-N
    1 3/16"2 1/8"3NEMA 4X
    UL Listed, CSA Certified
    8111K311000000———0
    1/4
    FemaleNPT
    0.08125 psi @ 70° FZero Pressure Drop, Solenoid35 to 180Buna-N
    1 11/16"3 1/2"3NEMA 4X
    UL Listed, CSA Certified
    8111K351000000———0
    1/4
    FemaleNPT
    0.09125 psi @ 70° FZero Pressure Drop, Solenoid35 to 180Buna-N
    1 11/16"3 3/4"3NEMA 4X
    UL Listed, CSA Certified
    8111K6520000002894N12000000
    1/4
    FemaleNPT
    0.12100 psi @ 70° FZero Pressure Drop, Solenoid35 to 180Buna-N
    1 11/16"3 3/4"3NEMA 4X
    UL Listed, CSA Certified
    8111K642000000———0
    1/4
    FemaleNPT
    0.2550 psi @ 70° FZero Pressure Drop, Solenoid35 to 180Buna-N
    1 11/16"3 3/4"3NEMA 4X
    UL Listed, CSA Certified
    8111K632000000———0
     
    430 Stainless Steel Body with Wire Lead Connection and Top Exhaust Port
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.11200 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 13/16"3NEMA 4X
    UL Listed, CSA Certified
    7889K62000000———0
    1/8
    FemaleNPT
    0.17125 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 13/16"3NEMA 4X
    UL Listed, CSA Certified
    7889K63000000———0
    1/8
    FemaleNPT
    0.2390 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 13/16"3NEMA 4X
    UL Listed, CSA Certified
    7889K94000000———0
    1/4
    FemaleNPT
    0.062250 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K64000000———0
    1/4
    FemaleNPT
    0.11200 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K65000000———0
    1/4
    FemaleNPT
    0.17125 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K66000000———0
    1/4
    FemaleNPT
    0.2390 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K67000000———0
    1/4
    FemaleNPT
    0.3825 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K68000000———0
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.11200 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 13/16"3NEMA 4X
    UL Listed, CSA Certified
    7889K22000000———0
    1/8
    FemaleNPT
    0.2390 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 13/16"3NEMA 4X
    UL Listed, CSA Certified
    7889K74000000———0
    1/8
    FemaleNPT
    0.23125 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 13/16"3NEMA 4X
    UL Listed, CSA Certified
    7889K23000000———0
    1/4
    FemaleNPT
    0.062250 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K24000000———0
    1/4
    FemaleNPT
    0.11200 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K25000000———0
    1/4
    FemaleNPT
    0.17125 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K26000000———0
    1/4
    FemaleNPT
    0.2390 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K270000002894N1800000
    1/4
    FemaleNPT
    0.3825 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K28000000———0
     
    Fail Open—24V DC
    1/4
    FemaleNPT
    0.052250 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K92000000———0
    1/4
    FemaleNPT
    0.1150 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K93000000———0
    1/4
    FemaleNPT
    0.17125 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K98000000———0
     
    Fail Open—120V AC
    1/4
    FemaleNPT
    0.052250 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K72000000———0
    1/4
    FemaleNPT
    0.1150 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K73000000———0
    1/4
    FemaleNPT
    0.17125 psi @ 70° FZero Pressure Drop, Solenoid-20 to 185Buna-N
    1 5/8"3 7/8"3NEMA 4X
    UL Listed, CSA Certified
    7889K78000000———0
     

    High-Pressure Compact Solenoid On/Off Valves

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. High-Pressure Compact Solenoid On/Off Valves.
    Control flow in high-pressure lines in tight spots—these valves have the highest pressure ratings of our compact valves. They operate on electricity to automatically start and stop flow. Made of 430 stainless steel, the body has good corrosion resistance. The enclosure of these valves meets NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust. The solenoid coil is a UL and C-UL Recognized Component and meets both American and Canadian safety standards.
    Valves are fail closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Dia.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Each
    430 Stainless Steel Body with Wire Lead Connection
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.0212,500 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 185Nylon
    1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K26200000002894N19000000
    1/8
    FemaleNPT
    0.0371,000 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 185PTFE
    1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K2820000002894N1900000
    1/8
    FemaleNPT
    0.06520 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 165PCTFE1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K4130000002894N1900000
    1/4
    FemaleNPT
    0.0212,500 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 185Nylon
    1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K3620000002894N1900000
    1/4
    FemaleNPT
    0.0371,000 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 185PTFE
    1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K3820000002894N1900000
    1/4
    FemaleNPT
    0.06520 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 165PCTFE1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K4430000002894N1900000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.0213,000 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 185Nylon
    1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K250000002894N1800000
    1/8
    FemaleNPT
    0.0371,500 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 185PTFE
    1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K270000002894N1800000
    1/8
    FemaleNPT
    0.061,000 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 165PCTFE1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K4110000002894N1800000
    1/4
    FemaleNPT
    0.0213,000 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 185Nylon
    1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K350000002894N1800000
    1/4
    FemaleNPT
    0.0371,500 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 185PTFE
    1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K370000002894N1800000
    1/4
    FemaleNPT
    0.061,000 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 165PCTFE1 5/8"2 7/8"NEMA 4X
    UL Recognized Component, C-UL Recognized Component
    48325K4410000002894N1800000
     

    Compact Solenoid Flow-Adjustment Valves

    Image of Product. Front orientation. Contains Annotated. Flow-Adjustment Valves. Compact Solenoid Flow-Adjustment Valves.
    Available in smaller pipe sizes than other solenoid flow-adjustment valves, these are often used with gas controllers and analytical instrumentation. They adjust and regulate flow based on the intensity of the electrical signal into the valve and are often integrated into PLC systems for automatic control over the valve position based on system conditions. They are fail closed unless actuated. Valves don’t require a pressure drop for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Thread
    Size
    Gender
    Thread
    Type
    Max. Pressure
    @ Temp.
    Valve Type
    Min. Pressure
    Drop Req.
    Temp. Range,
    ° F
    Input
    Signal
    Valve
    Dia.
    Overall
    Ht.
    For Use With
    Seal Material
    Each
    Nickel-Plated Brass Body with Wire Leads
     
    Fail Closed—12V DC
    10-32 FemaleUNF
    100 psi @ 70° FZero Pressure Drop, SolenoidNone35 to 1200 to 10V DC7/8"1 9/16"Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer
    2555N120000000
     
    Fail Closed—24V DC
    10-32 FemaleUNF
    100 psi @ 70° FZero Pressure Drop, SolenoidNone35 to 1200 to 20V DC7/8"1 9/16"Air, Argon, Helium, Krypton, Neon, XenonFluoroelastomer
    2555N13000000
     

    Premium Compact Solenoid On/Off Valves

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Premium Compact Solenoid On/Off Valves.
    Comparable to Asco Red Hat 8210G Series and Parker Gold Ring 23C Series, these valves meet the highest quality standards. They operate on electricity to automatically start and stop flow.
    Valves don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear. These valves meet NEMA 3S and 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
    304 Stainless Steel Body—304 stainless steel valves are more corrosion resistant than 430 stainless steel valves.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Fail-Open Valve—Fail open valves are open unless actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Repair Kits
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Each
    Each
    304 Stainless Steel Body with Wire Lead Connection
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.21145 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 3/16"2 7/8"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K93100000004639K2450000002863N15000000
    1/4
    FemaleNPT
    0.06500 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"2 15/16"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9350000004639K245000002863N1500000
    1/4
    FemaleNPT
    0.21145 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"2 15/16"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9340000004639K245000002863N1500000
    1/4
    FemaleNPT
    0.3585 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"2 15/16"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9330000004639K245000002863N1500000
    1/4
    FemaleNPT
    0.7325 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"2 15/16"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9320000004639K245000002863N1500000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.35120 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 3/16"2 7/8"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9110000004639K101000002863N3000000
    1/4
    FemaleNPT
    0.06725 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"2 15/16"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9160000004639K101000002863N1500000
    1/4
    FemaleNPT
    0.21160 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"2 15/16"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9150000004639K101000002863N3000000
    1/4
    FemaleNPT
    0.3590 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"2 15/16"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9130000004639K101000002863N1000000
    1/4
    FemaleNPT
    0.52145 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"3 1/8"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9140000004639K1090000002863N1000000
    1/4
    FemaleNPT
    0.8830 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"2 15/16"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9120000004639K101000002863N3000000
     
    Fail Open—24V DC
    1/8
    FemaleNPT
    0.2195 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 3/16"3"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9410000004639K1740000002863N1600000
    1/4
    FemaleNPT
    0.06400 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"3 1/8"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9430000004639K1740000002863N1600000
    1/4
    FemaleNPT
    0.2195 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"3 1/8"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9420000004639K1740000002863N1600000
     
    Fail Open—120V AC
    1/8
    FemaleNPT
    0.21180 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 3/16"3"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9210000004639K1740000002863N1000000
    1/4
    FemaleNPT
    0.06750 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"3 1/8"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9230000004639K1740000002863N1000000
    1/4
    FemaleNPT
    0.21180 psi @ 130° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    1 9/16"3 1/8"NEMA 3S, NEMA 4X
    UL Listed, CE Marked, CSA Certified, CSA-US Certified
    4639K9220000004639K1740000002863N1000000
     

    Miniature Solenoid On/Off Valves

    Image of Product. Front orientation. Contains SizingReference. Solenoid On/Off Valves. Miniature Solenoid On/Off Valves.
    Image of Product. Back orientation. Contains Annotated. Solenoid On/Off Valves. Miniature Solenoid On/Off Valves.
    Less than half the size of our other compact valves, these have small pipe connections for miniature lines. They operate on electricity to automatically start and stop flow.
    Valves are fail closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. Body is 430 stainless steel for good corrosion resistance. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Thread
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal Material
    Valve
    Dia.
    Overall
    Ht.
    Each
    430 Stainless Steel Body with Wire Lead Connection
     
    Fail Closed—12V DC
    10-32
    FemaleUNF
    0.033100 psi @ 150° FZero Pressure Drop, SolenoidNo-10 to 150Fluoroelastomer
    11/16"1 9/16"5001T45000000
     

    Compact Threaded Solenoid Diverting Valves

    Image of Product. Front orientation. Contains Annotated. Diverting Valves. Compact Threaded Solenoid Diverting Valves .
    Image of Attribute. Front orientation. Contains Annotated. Diverting Valves. Compact Threaded Solenoid Diverting Valves .
    Lower profile than other solenoid diverting valves and available in smaller pipe sizes, these are often used to automatically divert flow between ports in tight spots. They operate on electricity. All can direct flow from the side-port inlet to the side-port outlet or the top-port outlet. Valves cannot shut off flow. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is mounted directly to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    60V AC, 120V AC
    24V DC
    Pipe
    Size
    Diverting Valve
    Flow Pattern
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Min. Pressure
    Drop Req.
    Max. Temp.,
    ° F
    Actuation
    Time, sec.
    Valve
    Lg.
    Overall
    Ht.
    For Use With
    Seal
    Material
    Each
    Each
    430 Stainless Steel Body with Wire Leads
     
    NPT Female × NPT Female × NPT Female
    1/8
    L-Pattern0.17125 psi @ 185° FSolenoid, Zero Pressure DropNone16501 5/8"3 11/16"Air, Argon, Helium, Krypton, Neon, Oil, Water, XenonBuna-N
    2565N110000000———0
    1/4
    L-Pattern0.095125 psi @ 185° FSolenoid, Zero Pressure DropNone16501 5/8"3 13/16"Air, Argon, Helium, Krypton, Neon, Oil, Water, XenonBuna-N
    2565N120000002565N140000000
    1/4
    L-Pattern0.17125 psi @ 185° FSolenoid, Zero Pressure DropNone16501 5/8"3 13/16"Air, Argon, Helium, Krypton, Neon, Oil, Water, XenonBuna-N
    2565N130000002565N15000000
     

    Compact Solenoid On/Off Valves for Coolant

    Image of Product. Back orientation. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Brass Body with DIN A Connection.
    Image of Product. Back orientation. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Brass Body with DIN B Connection.
    Image of Product. Back orientation. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Brass Body with DIN BI Connection.
    Image of Product. Back orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Brass Body with DIN C Connection.

    Brass Body

    with DIN A

    Connection

    Brass Body

    with DIN B

    Connection

    Brass Body

    with DIN BI

    Connection

    Brass Body

    with DIN C

    Connection

    Image of Product. Back orientation. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, 303 Stainless Steel Body with DIN C Connection.
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, 303 Stainless Steel Body with Wire Lead Connection.
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Acetal Body with Wire Lead Connection.

    303

    Stainless

    Steel

    Body with

    DIN C

    Connection

    303 Stainless

    Steel Body with

    Wire Lead

    Connection

    Acetal

    Body with

    Wire Lead

    Connection

    Reduce your pipeline footprint with these low-profile valves that are about half the size of standard valves for coolant. They operate on electricity to automatically start and stop flow.
    Valves are fail closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Brass Body—Brass valves are more durable than acetal valves.
    303 Stainless Steel Body—303 stainless steel valves are more durable than acetal valves. They are more corrosion resistant than brass valves.
    IP65 Enclosure Rating—IP65 valves resist low-pressure jets of water and dust.
    IP67 Enclosure Rating—IP67 valves are dust tight and protected from temporary submersion.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valve
    Mounting
    Holes
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal Material
    Lg.
    Dia.
    Overall
    Ht.
    No.
    of
    Dia.
    Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    Brass Body with DIN A Connection
     
    Fail Closed—24V AC
    1/4
    FemaleNPT
    0.35218 psi @ 140° FZero Pressure Drop, SolenoidNo32 to 266Fluoroelastomer
    1 11/16"3 3/8"IP67
    CE Marked
    4807T129000000
     
    Fail Closed—24V DC
    1/4
    FemaleNPT
    0.35130 psi @ 140° FZero Pressure Drop, SolenoidNo32 to 260Fluoroelastomer
    1 11/16"3 3/8"IP67
    CE Marked
    4807T13800000
     
    Brass Body with DIN B Connection
     
    Fail Closed—24V AC
    1/8
    FemaleNPT
    0.16280 psi @ 140° FZero Pressure Drop, SolenoidNo32 to 260Fluoroelastomer
    1 5/16"2 3/4"IP67
    CE Marked
    4807T11800000
     
    Brass Body with DIN BI Connection
     
    Fail Closed—24V AC
    1/8
    FemaleNPT
    0.21102 psi @ 140° FZero Pressure Drop, SolenoidNo32 to 266Fluoroelastomer
    1 5/16"2 3/4"IP67
    CE Marked
    4807T12800000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.2172 psi @ 140° FZero Pressure Drop, SolenoidNo35 to 140Fluoroelastomer
    1 5/16"2 5/8"IP67
    CE Marked
    4807T12500000
     
    Brass Body with DIN C Connection
     
    Fail Closed—24V AC
    1/8
    FemaleNPT
    0.13115 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K222000000
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.01540 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K233000000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.1585 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K231000000
     
    303 Stainless Steel Body with DIN C Connection
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.0785 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K111000000
    1/8
    FemaleNPT
    0.1365 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K113000000
    1/8
    FemaleNPT
    0.1540 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K122000000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.07175 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K112000000
    1/8
    FemaleNPT
    0.13115 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K121000000
    1/8
    FemaleNPT
    0.1585 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K123000000
     
    303 Stainless Steel Body with Wire Lead Connection
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.06390 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 210Fluoroelastomer
    1"2 5/8"NEMA 4X
    UL Listed, C-UL Listed
    7900K841000000
    1/8
    FemaleNPT
    0.22130 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 210Fluoroelastomer
    1"2 5/8"NEMA 4X
    UL Listed, C-UL Listed
    7900K851000000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.06950 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 210Fluoroelastomer
    1"2 5/8"NEMA 4X
    UL Listed, C-UL Listed
    7900K843000000
    1/8
    FemaleNPT
    0.22320 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 210Fluoroelastomer
    1"2 5/8"NEMA 4X
    UL Listed, C-UL Listed
    7900K853000000
     
    Acetal Body with Wire Lead Connection
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.09300 psi @ 150° FZero Pressure Drop, SolenoidNo0 to 150Fluoroelastomer
    1 5/16"2 1/4"21/4"No5760T12100000
     

    Compact Solenoid On/Off Valves with Push-to-Connect Fittings

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves with Push-to-Connect Fittings.
    Insert tubing into the fittings on these valves—no heat, solder, or flux required. They operate on electricity to automatically start and stop flow.
    Valves are fail closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    For Tube
    OD
    Gender
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Lg.
    Overall
    Ht.
    Quick-Disconnect
    Tab Wd.
    Certification
    Each
    Polycarbonate Body with Quick-Disconnect-Terminal Wire Connection
     
    Fail Closed—24V DC
    1/4"Female0.31480 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T4330000000
    1/4"Female0.36740 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T453000000
    3/8"Female15 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2 3/8"3"1/4"CSA Certified
    5489T493000000
     
    Fail Closed—120V AC
    1/4"Female0.31480 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T431000000
    1/4"Female0.36740 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T451000000
    3/8"Female15 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2 3/8"3"1/4"CSA Certified
    5489T491000000
     
    Polysulfone Body with Quick-Disconnect-Terminal Wire Connection
     
    Fail Closed—24V DC
    1/4"Female0.228120 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T413000000
     
    Fail Closed—120V AC
    1/4"Female0.228120 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T411000000
     
    back to top