    About Selecting Thermal Insulation
    industrial info icon

    Compare R-value and temperature range to find the insulation material that best suits your application.

    Strong-Grip Pipe Insulation Tapes

    Image of ProductInUse. Front orientation. Pipe Insulation. Strong-Grip Pipe Insulation Tapes.
    Seal joints and gaps in your line in seconds. This tape wraps around irregular shapes, tight bends, small-diameter pipes, and other hard-to-reach areas where you need a quick fix.
    Vinyl Foam with Foil Jacket—Prevent condensation from forming. The foil jacket repels moisture while also shielding pipes from dirt, dust, and minor scuffs.
    Butyl—Flexible enough to wrap around pipe without tearing or cracking.
    Buna-N/Neoprene/Vinyl Foam—This combination repels moisture to prevent condensation, drip formation, and mold growth.
    Cork Rubber—A layer of cork resists oil, reduces vibration, and dampens sound.
    Adhesive Backing
    Thk.
    Wd.
    Lg.,
    ft.
    Temp. Range,
    ° F
    Insulation
    R Value
    Heat Flow Rate
    @ Temp.
    Flexibility
    Each
    Vinyl Foam with Foil Jacket
    1/8"2"30-40 to 1802Not RatedFlexible6801K21000000
     
    Butyl
    1/8"2"30-30 to 17520.14 BTU/hr @ 75° FFlexible4476K200000
     
    Buna-N/Neoprene/Vinyl Foam
    1/8"2"30-40 to 160Not Rated0.3 BTU/hr @ 75° FFlexible6801K2200000
     
    Cork Rubber
    1/8"2"3020 to 190Not Rated0.25 BTU/hr @ 75° FFlexible93855K1100000
     

    Corrosion-Resistant Protective Film and Tape

    Image of Product. Front orientation. Protective Film and Tape. Corrosion-Resistant Protective Film and Tape.
    Providing all-weather corrosion protection, this vinyl tape resists salt water, UV light, acids, and alkalies. It also resists impact and abrasion. Use it to wrap pipes and electrical conduit both above and below ground.
    Wd.
    Lg.,
    ft.
    Thk.
    Material
    Adhesive
    Material
    Temp. Range,
    ° F
    Tensile Strength,
    lbf/in. wd.
    Adhesion to
    Steel, lbf/in. wd.
    Color
    Each
    2"750.03"Rubber
    Synthetic Rubber-20 to 1403015Gray5459K72000000
    4"750.03"Rubber
    Synthetic Rubber-20 to 1403015Gray5459K75000000
    6"750.03"Rubber
    Synthetic Rubber-20 to 1403015Gray5459K77000000
     

    Thermally Insulating Wraparound Heaters for Pipe

    Image of Product. Front orientation. Wraparound Heaters. Thermally Insulating Wraparound Heaters for Pipe.
    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Thermally Insulating Wraparound Heaters for Pipe.

    5-15

    Keep liquid in your pipes from freezing, maintain a specific viscosity, and prevent condensation in cold areas. Also known as heat blankets, these heaters wrap around your pipe to quickly warm the contents without direct contact. Do not use in hazardous areas.
    With Self-Regulating Temp. Control—These heaters are self-regulating, so they automatically adjust their heat output to account for temperature differences along the length of the heater. They output high heat for sections of pipe exposed to the cold, and low heat for a section that’s in a warmer spot. There’s no need for a separate temperature switch or controller; just plug them in and they start heating.
    Foam—Their foam insulation retains heat, so your pipes will stay warm even in drafty areas.
    Overall
    For Pipe OD
    Lg.,
    ft.
    Wd.
    Wattage,
    W
    Watt Density
    @ 30° F, W/ft
    Voltage,
    V AC
    Electrical
    Phase
    Current,
    amp
    Thk.
    NEMA
    Type
    For Surface Material
    Material
    Insulation
    Material
    Closure
    Method
    Each
    With Self-Regulating Temp. Control
     
    80° F Maximum Heat Output
    3/4" to 1 1/2"510"255120Single0.24"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N110000000
    3/4" to 1 1/2"1010"505120Single0.414"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N12000000
    3/4" to 1 1/2"2510"1255120Single1.044"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N13000000
    2" to 2 1/2"511"255120Single0.24"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N14000000
    2" to 2 1/2"1011"505120Single0.414"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N15000000
    2" to 2 1/2"2511"1255120Single1.044"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N16000000
    3" to 3 1/2"512"255120Single0.24"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N17000000
    3" to 3 1/2"1012"505120Single0.414"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N18000000
    3" to 3 1/2"2512"1255120Single1.044"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N1900000000
    4" to 4 1/2"513"255120Single0.24"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N21000000
    4" to 4 1/2"1013"505120Single0.414"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N22000000
    4" to 4 1/2"2513"1255120Single1.044"5-15
    For Fiberglass, Metal, Plastic, or SteelVinyl PlasticFoamHook and Loop6583N2300000000
     

    Thermally Insulating Wraparound Heaters for Hose

    Image of Product. Front orientation. Wraparound Heaters. Thermally Insulating Wraparound Heaters for Hose.
    Keep the liquid inside your hose from freezing, maintain your liquid’s viscosity, and prevent condensation in chilly environments. Also known as heat blankets, these heaters wrap around your hose to warm the contents quickly without direct contact. Do not use these heaters near combustible gases or dust.
    Adjustable Thermostat—0° F to 180° F Temp. Control Range
    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Thermally Insulating Wraparound Heaters for Hose.

    5-15

    Heaters with an adjustable thermostat let you fine-tune the heat output, so they’re best if there are surrounding temperature changes or you want the liquid in your line to be at a certain temperature. For instance, if a liquid needs to be at a certain temperature to mix well, you can adjust the heat output on the digital keypad as needed. These heaters automatically turn on or off to keep your hose consistently warm.
    Fiberglass—Heaters are insulated with fiberglass, so they retain heat even in unheated and drafty areas.
    Overall
    For Hose
    OD Range
    Lg.,
    ft.
    Wd.
    Wattage,
    W
    Watt Density,
    W/ft
    Voltage,
    V AC
    Electrical
    Phase
    Current,
    amp
    Thk.
    Max. Heat
    Output, ° F
    NEMA
    Type
    Material
    Insulation
    Material
    Each
    1/4" to 1/2"103"10010120Single13/4"1805-15
    Vinyl PlasticFiberglass6570N110000000
    1/4" to 1/2"253"25010120Single2.083/4"1805-15
    Vinyl PlasticFiberglass6570N1200000000
    1/4" to 1/2"503"50010120Single4.163/4"1805-15
    Vinyl PlasticFiberglass6570N1300000000
    3/4" to 1"105"10010120Single13/4"1805-15
    Vinyl PlasticFiberglass6570N14000000
    3/4" to 1"255"25010120Single2.083/4"1805-15
    Vinyl PlasticFiberglass6570N1500000000
    3/4" to 1"505"50010120Single4.163/4"1805-15
    Vinyl PlasticFiberglass6570N1600000000
    1 1/4" to 2"108 1/2"10010120Single13/4"1805-15
    Vinyl PlasticFiberglass6570N1700000000
    1 1/4" to 2"258 1/2"25010120Single2.083/4"1805-15
    Vinyl PlasticFiberglass6570N1800000000
    1 1/4" to 2"508 1/2"50010120Single4.163/4"1805-15
    Vinyl PlasticFiberglass6570N1900000000
    Self-Regulating Temp. Control
    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Thermally Insulating Wraparound Heaters for Hose.

    5-15

    Heaters with self-regulating temperature control work well when all you need is freeze protection and to prevent condensation. Just plug them in and they start heating—no fussing with a thermostat or temperature controller. They automatically adjust the heat output to account for temperature differences along the length of the heater. For instance, if a hose runs both indoors and outdoors in the winter, these heaters will output high heat to the section that runs outdoors and less heat to the section that runs indoors.
    Fiberglass—Heaters are insulated with fiberglass, so they retain heat even in unheated and drafty areas.
    Overall
    For Hose
    OD Range
    Lg.,
    ft.
    Wd.
    Wattage,
    W
    Watt Density
    @ 30° F, W/ft
    Voltage,
    V AC
    Electrical
    Phase
    Current,
    amp
    Thk.
    Max. Heat
    Output, ° F
    NEMA
    Type
    Material
    Insulation
    Material
    Each
    1/4" to 1/2"103"10010120Single13/4"1505-15
    Vinyl PlasticFiberglass6570N210000000
    1/4" to 1/2"253"25010120Single2.083/4"1505-15
    Vinyl PlasticFiberglass6570N2200000000
    1/4" to 1/2"503"50010120Single4.163/4"1505-15
    Vinyl PlasticFiberglass6570N2300000000
    3/4" to 1"105"10010120Single13/4"1505-15
    Vinyl PlasticFiberglass6570N24000000
    3/4" to 1"255"25010120Single2.083/4"1505-15
    Vinyl PlasticFiberglass6570N2500000000
    3/4" to 1"505"50010120Single4.163/4"1505-15
    Vinyl PlasticFiberglass6570N2600000000
    1 1/4" to 2"108 1/2"10010120Single13/4"1505-15
    Vinyl PlasticFiberglass6570N2700000000
    1 1/4" to 2"258 1/2"25010120Single2.083/4"1505-15
    Vinyl PlasticFiberglass6570N2800000000
    1 1/4" to 2"508 1/2"50010120Single4.163/4"1505-15
    Vinyl PlasticFiberglass6570N2900000000