Number of Poles Number of Poles | Show |
---|
|
Type Type |
---|
|
System of Measurement System of Measurement |
---|
|
Connection Type Connection Type |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | ![]() |
Solder | Wire Leads |
Connector Shell Size Connector Shell Size |
---|
|
Housing Connection Type Housing Connection Type |
---|
|
Specifications Met Specifications Met |
---|
|
Housing Material Housing Material |
---|
|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Mini Connectors
Often used to send power and signal to automated systems, motors, and pumps, these mini connectors carry higher currents than M5, M8, and M12 connectors. A threaded housing securely mates with other mini connectors and won’t come loose from shaking or vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors.
Receptacles thread into panels and walls, so they work well in stationary or permanent installations. Receptacles with epoxy-coated zinc housing resist corrosion and weld-slag for use in harsh environments.
When mated, these connectors meet IP or NEMA ratings. IP67 rated connectors protect against dust and temporary submersion.
Caps protect connectors and maintain their IP and NEMA ratings when not in use.
Thread adapters connect plugs and sockets that both have internal threads.
For technical drawings and 3-D models, click on a part number.

Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Type | Max. Temp., °F | Environmental Rating | Each | |
6 ft. Lg. Cable Leads | |||||||||||||||
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | 0.54" | PVC Plastic | Yellow | Rubber | 1"-16 | UNS | 220° | IP67 | 000000000 | 000000 |
12 ft. Lg. Cable Leads | |||||||||||||||
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | 0.54" | PVC Plastic | Yellow | Rubber | 1"-16 | UNS | 220° | IP67 | 00000000 | 000000 |

Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Type | Max. Temp., °F | Environmental Rating | Each | |
6 ft. Lg. Cable Leads | |||||||||||||||
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | 0.54" | PVC Plastic | Yellow | Rubber | 1"-16 | UNS | 220° | IP67 | 000000000 | 000000 |
12 ft. Lg. Cable Leads | |||||||||||||||
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | 0.54" | PVC Plastic | Yellow | Rubber | 1"-16 | UNS | 220° | IP67 | 00000000 | 000000 |

Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Type | Temp. Range, °F | Environmental Rating | Each | |
6 ft. Lg. Cable Leads | |||||||||||||||
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | 0.54" | PVC Plastic | Yellow | Rubber | 1"-16 | UNS | 0° to 220° | IP67 | 000000000 | 000000 |
12 ft. Lg. Cable Leads | |||||||||||||||
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | 0.54" | PVC Plastic | Yellow | Rubber | 1"-16 | UNS | 0° to 220° | IP67 | 00000000 | 000000 |

Housing Thread | Mounting | 1 ft. Wire Lead Lg. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Color | Housing Material | Size | Type | Pipe Size | Thread Type | For Panel Cutout Dia. | Max. Temp., °F | Environmental Rating | Each | |
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | Black | Epoxy-Coated Zinc | 1"-16 | UNS | 1/2 | NPT | 0.88" | 220° | IP67 | 00000000 | 000000 |

Housing Thread | Mounting | 1 ft. Wire Lead Lg. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Color | Housing Material | Size | Type | Pipe Size | Thread Type | For Panel Cutout Dia. | Max. Temp., °F | Environmental Rating | Each | |
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | Black | Epoxy-Coated Zinc | 1"-16 | UNS | 1/2 | NPT | 0.88" | 220° | IP67 | 00000000 | 000000 |

Thread | |||||
---|---|---|---|---|---|
Size | Type | Material | Temp. Range, °F | Each | |
External Thread | |||||
1"-16 | UNS | Aluminum | -4° to 190° | 00000000 | 00000 |
Harsh Environment Mini Connectors
Send higher current than M5, M8, and M12 connectors near tough industrial jobs, such as welding and metal machining. These mini connectors have a stainless steel housing or TPE cable that resists abrasion and cracking from exposure to water, chemicals, oil, coolant, or weld slag. They’re commonly used to send power and signal to automated systems, motors, and pumps. A threaded housing securely mates with other mini connectors to keep out contaminants and won’t come loose from shaking or vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors.
When mated, these connectors meet IP67 and NEMA 6P for protection against dust, submersion, washdowns, and weather.
Plugs and sockets have a flexible cable that is good for applications with continuous motion, such as robotics.
Receptacles thread into panels and walls, so they work well in stationary or permanent installations.
Caps protect connectors and maintain their IP and NEMA ratings when not in use.
Thread adapters connect plugs and sockets that both have internal threads.
For technical drawings and 3-D models, click on a part number.

Housing Thread | 12 ft. Cable Lead Lg. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Type | Max. Temp., °F | Environmental Rating | Each | |
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | 0.54" | TPE Rubber | Yellow | Plastic | 1"-16 | UNS | 190° | IP67, NEMA 6P | 0000000 | 0000000 |

Housing Thread | 12 ft. Cable Lead Lg. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Type | Max. Temp., °F | Environmental Rating | Each | |
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | 0.54" | TPE Rubber | Yellow | Plastic | 1"-16 | UNS | 190° | IP67, NEMA 6P | 0000000 | 0000000 |
Housing Thread | 12 ft. Cable Lead Lg. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Type | Max. Temp., °F | Environmental Rating | Each | |
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | 0.54" | TPE Rubber | Yellow | Plastic | 1"-16 | UNS | 190° | IP67, NEMA 6P | 0000000 | 0000000 |

Housing Thread | 1 ft. Wire Lead Lg. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Housing Material | Size | Type | Type | For Panel Cutout Dia. | Max. Temp., °F | Environmental Rating | Mounting Pipe Size | Each | |
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | Stainless Steel | 1"-16 | UNS | NPT | 0.88" | 190° | IP67, NEMA 6P | 1/2 | 0000000 | 000000 |

Housing Thread | 1 ft. Wire Lead Lg. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | Wire Lead Gauge | Housing Material | Size | Type | Type | For Panel Cutout Dia. | Max. Temp., °F | Environmental Rating | Mounting Pipe Size | Each | |
7 | 1 | 0.7" | 600V AC/600V DC | 8A | 16 | Stainless Steel | 1"-16 | UNS | NPT | 0.88" | 190° | IP67, NEMA 6P | 1/2 | 0000000 | 000000 |
Thread | |||||
---|---|---|---|---|---|
Size | Type | Material | Temp. Range, °F | Each | |
External Thread | |||||
1"-16 | UNS | Stainless Steel | -55° to 390° | 00000000 | 000000 |
Micro M16 Connectors
Screw these micro M16 connectors together to securely connect equipment. They’re good for use with sensors, inspection cameras, servomotors, and actuators within industrial automation systems.
For technical drawings and 3-D models, click on a part number.



Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
7 | 1 | 0.47" | 300V AC/ 300V DC | 5A | 20 | 0.16"-0.24" | Nickel-Plated Zinc | M16 | 0.75 | -40° to 210° | IP40 | UL Listed, IEC 61076-2-106 | 0000000 | 000000 |



Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
7 | 1 | 0.47" | 300V AC/ 300V DC | 5A | 20 | 0.16"-0.24" | Nickel-Plated Zinc | M16 | 0.75 | -40° to 210° | IP40 | UL Listed, IEC 61076-2-106 | 0000000 | 000000 |



Housing Thread | Mounting Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | For Wire Gauge | Housing Material | Size | Pitch, mm | Size | Pitch, mm | For Panel Cutout Dia. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
7 | 1 | 0.47" | 300V AC/300V DC | 5A | 20 | Nickel-Plated Zinc | M16 | 0.75 | M18 | 0.75 | 0.71" | -40° to 210° | IP40 | UL Listed, IEC 61076-2-106 | 0000000 | 000000 |



Housing Thread | Mounting Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | For Wire Gauge | Housing Material | Size | Pitch, mm | Size | Pitch, mm | For Panel Cutout Dia. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
7 | 1 | 0.47" | 300V AC/300V DC | 5A | 20 | Nickel-Plated Zinc | M16 | 0.75 | M18 | 0.75 | 0.71" | -40° to 210° | IP40 | UL Listed, IEC 61076-2-106 | 0000000 | 000000 |
Micro M16 Wet-Location Connectors
Rated IP69K, these M16 connectors protect against dust, debris, and hot, high-pressure jets of water at high volumes. Screw them together to securely connect equipment, such as sensors, inspection cameras, servomotors, and actuators within industrial automation systems.
For technical drawings and 3-D models, click on a part number.



Housing Thread | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Temp. Range, °F | Specifications Met | Each | |
7 | 1 | 0.47" | 150V AC/150V DC | 7A | 20 | 0.23"-0.31" | Nickel-Plated Zinc | M16 | 0.75 | -40° to 210° | UL Listed, IEC 61076-2-106 | 0000000 | 000000 |



Housing Thread | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Temp. Range, °F | Specifications Met | Each | |
7 | 1 | 0.47" | 150V AC/150V DC | 7A | 20 | 0.23"-0.31" | Nickel-Plated Zinc | M16 | 0.75 | -40° to 210° | UL Listed, IEC 61076-2-106 | 0000000 | 000000 |



Housing Thread | Mounting Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Size | Pitch, mm | For Panel Cutout Dia. | Temp. Range, °F | Specifications Met | Each | |
7 | 1 | 0.47" | 150V AC/150V DC | 7A | 20 | 0.23"-0.31" | Nickel-Plated Zinc | M16 | 0.75 | M18 | 0.75 | 0.71" | -40° to 210° | UL Listed, IEC 61076-2-106 | 0000000 | 000000 |



Housing Thread | Mounting Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Size | Pitch, mm | For Panel Cutout Dia. | Temp. Range, °F | Specifications Met | Each | |
7 | 1 | 0.47" | 150V AC/150V DC | 7A | 20 | 0.23"-0.31" | Nickel-Plated Zinc | M16 | 0.75 | M18 | 0.75 | 0.71" | -40° to 210° | UL Listed, IEC 61076-2-106 | 0000000 | 000000 |
Mil. Spec. Screw-Together Connectors
Rated to MIL-DTL-5015 specifications, these connectors are compatible with other products that meet the same standard. They can withstand high-vibration applications and frequent connection and disconnection. All come assembled with pins and sockets in place. When mating connectors, both the gender and housing thread location must be opposite.
Caps (sold separately) protect connectors when not in use.
For technical drawings and 3-D models, click on a part number.


Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | For Cable OD | Lg. | Wd. | Ht. | Housing Material | Size | Type | Temp. Range, °F | Connector Shell Size | Military Specifications Met | Each | |
7 | 500V AC/700V DC | 13A | 20-16 | 0.26"-0.55" | 2.3" | 1" | 1.3" | Cadmium-Plated Aluminum | 1"-20 | UNEF | -65° to 255° | 16S | MS3101F16S-1P | 0000000 | 000000 |


Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | For Cable OD | OD | Lg. | Housing Material | Size | Type | Temp. Range, °F | Connector Shell Size | Military Specifications Met | Each | |
7 | 500V AC/700V DC | 13A | 20-16 | 0.26"-0.55" | 1.3" | 2.3" | Cadmium-Plated Aluminum | 1"-20 | UNEF | -65° to 255° | 16S | MS3106F16S-1P | 0000000 | 000000 |


Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | For Cable OD | Lg. | Wd. | Ht. | Housing Material | Size | Type | Temp. Range, °F | Connector Shell Size | Military Specifications Met | Each | |
7 | 500V AC/700V DC | 13A | 20-16 | 0.26"-0.55" | 2.3" | 1" | 1.3" | Cadmium-Plated Aluminum | 1"-20 | UNEF | -65° to 255° | 16S | MS3101F16S-1S | 0000000 | 000000 |


Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | For Cable OD | OD | Lg. | Housing Material | Size | Type | Temp. Range, °F | Connector Shell Size | Military Specifications Met | Each | |
7 | 500V AC/700V DC | 13A | 20-16 | 0.26"-0.55" | 1.3" | 2.3" | Cadmium-Plated Aluminum | 1"-20 | UNEF | -65° to 255° | 16S | MS3106F16S-1S | 0000000 | 000000 |


Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | Lg. | Wd. | Ht. | Housing Material | Size | Type | For Panel Cutout Dia. | Temp. Range, °F | Connector Shell Size | Military Specifications Met | Each | |
7 | 500V AC/700V DC | 13A | 20-16 | 1" | 1.3" | 1.3" | Cadmium-Plated Aluminum | 1"-20 | UNEF | 0.875" | -65° to 255° | 16S | MS3102R16S-1P | 0000000 | 000000 |


Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | Lg. | Wd. | Ht. | Housing Material | Size | Type | For Panel Cutout Dia. | Temp. Range, °F | Connector Shell Size | Military Specifications Met | Each | |
7 | 500V AC/700V DC | 13A | 20-16 | 1.1" | 1.3" | 1.3" | Cadmium-Plated Aluminum | 1"-20 | UNEF | 0.875" | -65° to 255° | 16S | MS3102R16S-1S | 0000000 | 000000 |
Mini Cords
With a higher maximum current than nano M8 and micro M12 cords, these mini cords are often used with automated systems, motors, and pumps. A threaded housing securely mates with other mini connections and won’t shake loose from vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors. These cords are unshielded, so they’re best for use where signal interference is not a concern.
When mated, these cords meet IP ratings for protection from dust and temporary submersion.
Thread adapters connect plugs and sockets that both have internal threads.
Caps protect connectors and maintain their IP ratings when not in use.
For technical drawings and 3-D models, click on a part number.


Cord | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | No. of Keyways | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Temp. Range, °F | Shielding | Specifications Met | Color | Each | |
Plug (Internal Thread) × Socket (Internal Thread) | |||||||||||||||
7 | 1 | 0.7" | 6 | 8 | 600V AC/600V DC | 1"-16 | 16 | 0.62" | PVC Plastic | 0° to 220° | Unshielded | CSA Certified, UL Recognized Component | Yellow | 00000000 | 0000000 |

Thread Size | Material | Each | |
External Thread | |||
---|---|---|---|
1"-16 | Aluminum | 00000000 | 00000 |
For No. of Keyways | For Face Dia. | Thread Size | Material | Includes | Each | |
External Thread | ||||||
---|---|---|---|---|---|---|
1 | 0.7" | 1"-16 | Epoxy-Coated Zinc | Lanyard | 00000000 | 000000 |
Harsh Environment Mini Cords
Often used for automated systems, motors, and pumps in tough industrial areas such as near welding and metal machining, these cords carry higher current than M5, M8, and M12 cords. The TPE cord insulation won’t pit or crack from water, chemicals, oil, coolant, or weld slag. The cable is also flexible enough to use in applications that require motion, like robotics. A threaded housing securely mates with other mini connections and won’t shake loose from vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors. These cords are unshielded, so choose them when signal interference is not a concern.
When mated, these cords meet IP67 and NEMA 6P for protection against dust, washdowns, temporary submersion, and weather.
Thread adapters connect plugs and sockets that both have internal threads.
Caps protect connectors and maintain their IP and NEMA ratings when not in use.
For technical drawings and 3-D models, click on a part number.


Cord | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | No. of Keyways | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Max. Temp., °F | Shielding | Specifications Met | Color | Each | |
Plug (Internal Thread) × Socket (Internal Thread) | |||||||||||||||
7 | 1 | 0.7" | 6 | 8 | 600V AC/600V DC | 1"-16 | 16 | 0.54" | TPE Rubber | 190° | Unshielded | UL Recognized Component, C-UL Recognized Component | Yellow | 0000000 | 0000000 |

Thread Size | Material | Electrical Connector Component | Each | |
External Thread | ||||
---|---|---|---|---|
1"-16 | Stainless Steel | Adapter | 00000000 | 000000 |

For No. of Keyways | For Face Dia. | Thread Size | Material | Includes | Each | |
External Thread | ||||||
---|---|---|---|---|---|---|
1 | 0.7" | 1"-16 | Stainless Steel | Lanyard | 00000000 | 000000 |
Grease-Dispensing Monitors

Extend the life of bearings by using these monitors to take the guesswork out of lubrication. Their sensor captures the ultrasonic vibration of grease as it fills your bearing and converts it into sound you can hear. As your bearing draws in the grease, the sound becomes quieter. Even in loud machine shops, you'll be able to track this sound with the noise-cancelling headphones and noise level readings shown on the monitor's screen. When the noise level stops decreasing, the bearing can't absorb any more grease and you should stop pumping grease to avoid over-lubricating your bearing.
The handset guides you through the steps for setting the noise level before applying grease. Use either the curved or flat magnetic mount to attach the sensor to the bearing. The monitor mounts to your grease gun, so you’ll have your hands free for pumping grease.

Headphones | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Measuring Range, kHz | Display Type | Maximum Noise Output, dB | Noise Reduction Rating, dB | Run Time, hrs. | Batteries Included | Housing Material | Container Type | Temperature Range, °F | Environmental Rating | Includes | Each | |
35 to 42 | OLED | 83 | 25 | 7 | Yes | ABS Plastic | Plastic Case | 14° to 122° | IP42 | Monitor Headphones Sensor Cord Grease Sensor Grease Sensor Adapter Curved Magnetic Sensor Mount Flat Magnetic Sensor Mount Hook and Loop Grease Gun Mount Magnetic Grease Gun Mount | 0000000 | 000000000 |





Component | Includes | Each | |
Monitor | __ | 00000000 | 000000000 |
Headphones | __ | 00000000 | 000000 |
Sensor Kit | Sensor Cord Grease Sensor Grease Sensor Adapter Curved Magnetic Sensor Mount Flat Magnetic Sensor Mount | 00000000 | 00000000 |
Grease Gun Mounts | Hook and Loop Grease Gun Mount Magnetic Grease Gun Mount | 00000000 | 000000 |
Plastic Case | __ | 00000000 | 000000 |