McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    15 Products

    Liquid-Tight Plastic Cord Grips

    Image of Product. Front orientation. Cord Grips. Liquid-Tight Plastic Cord Grips, Straight.

    Straight

    Block out liquid while securing cords where they enter enclosures. Sealed with an O-ring, these cord grips are IP and NEMA rated to keep out dust and water, even during washdowns. A locknut anchors them in the knockout.
    Each
    For Cord OD
    For Knockout
    Trade Size
    Material
    Enclosure Rating
    Temp. Range,
    ° F
    For Cord
    Shape
    Specs. Met
    Features
    1-9
    10-Up
    Straight
     
    Metric Thread
    1.1" to 1.53"M63
    NylonIP66, IP68, IP69, NEMA 6, NEMA 12
    0 to 175RoundC-UL Listed, UL Listed, CE Marked, DNV-GL Type Approved,
    TUV Rheinland Certified, VDE Certified
    Nylon Plastic Locknut, Rubber O-Ring7310K58000000000000
    1.33" to 1.77"M63
    NylonIP66, IP68, IP69, NEMA 6, NEMA 12
    0 to 175RoundC-UL Listed, UL Listed, CE Marked, DNV-GL Type Approved,
    TUV Rheinland Certified, VDE Certified
    Nylon Plastic Locknut, Rubber O-Ring7310K450000000000
     

    Wraparound Cable Entry Panels

    Attach a cable entry panel to cord without removing connectors and rewiring. These cable entry panels have a two-piece design to fit around cables with connectors. Choose a housing and then select inserts (sold separately). Inserts have a slit, eliminating the need to thread cable through them.
    Knockout-Mount Housings
    Image of Product. Front orientation. Cable Entry Panels. Wraparound Cable Entry Panels, Knockout Mount.
    Image of Product. Knockout-Mount Housing Shown Open. Front orientation. Exploded view. Cable Entry Panels. Wraparound Cable Entry Panels, Knockout Mount.
    Image of Specification. 4 Small Inserts. Front orientation. For Small Inserts. Wraparound Cable Entry Panels, Knockout Mount, For 4 Inserts.

    Knockout-Mount

    Housing Shown

    Open

    4 Small

    Inserts

    For
    Insert
    For No.
    of Inserts
    Shape
    For Knockout
    Trade Size
    Ht.
    Wd.
    Thread
    Type
    For Max.
    Panel Thk.
    Temp. Range,
    ° F
    Features
    Enclosure
    Rating
    Certification
    Each
    Gray Polycarbonate
    4 SmallStraightM63
    0.83"0.83"Metric
    0.31"-20 to 190Nylon Plastic Locknut, Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    1016N23000000
     

    Low-Profile Submersible Break-Through Cable Entry Panels

    The face of these panels is flush with the cable-entry point for a seamless appearance. They have a thin, flexible seal that covers the holes until you push a cord through.
    Knockout Mount
    Image of Product. For 9 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 9 Total Cords.
    Image of Product. For 13 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 13 Total Cords.
    Image of Product. For 14 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 14 Total Cords.
    Image of Product. For 35 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 35 Total Cords.

    For 9 Cords

    For 13 Cords

    For 14 Cords

    For 35 Cords

    NEMA 4X Enclosure Rating, NEMA 12 Enclosure Rating, IP66 Enclosure Rating, and IP68 Enclosure Rating—Panels are rated IP66, IP68, NEMA 4X, and NEMA 12 for protection from continuous submersion, washdowns and oil/coolant splashing.
    For Total
    No. of Cords
    Shape
    For Cord OD (No. of Cords)
    For Knockout
    Trade Size
    Thread
    Type
    For Max.
    Panel Thk.
    Temp. Range,
    ° F
    Features
    Enclosure Rating
    Certification
    Each
    Gray Nylon
    9Straight0.13" to 0.25" (1), 0.2" to 0.4" (3), 0.35" to 0.64" (4), 0.63" to 0.87" (1)M63
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    1777N26000000
    13Straight0.13" to 0.25" (4), 0.2" to 0.4" (4), 0.35" to 0.64" (5)M63
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    1777N2700000
    14Straight0.2" to 0.4"M63
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    1777N2800000
    35Straight0.13" to 0.25"M63
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    1777N2900000
     

    Liquid-Tight Brass Cord Grips

    Image of Product. Front orientation. Cord Grips. Liquid-Tight Brass Cord Grips.
    A bump up in strength from aluminum liquid-tight cord grips, but not as strong as stainless steel. These cord grips are nickel-plated brass, so they resist rusting from moisture. Sealed with an O-ring, they're IP or NEMA rated to block out dust and water. A locknut anchors them in the knockout.
    For Cord OD
    For Knockout
    Trade Size
    Material
    Enclosure Rating
    Temp. Range,
    ° F
    For Cord
    Shape
    Specs. Met
    Features
    Each
    Straight
     
    Metric Thread
    1.34" to 1.77"M63
    Nickel-Plated BrassIP68, NEMA 4X, NEMA 6, NEMA 12
    -75 to 210RoundCE Marked, UL Recognized Component, VDE CertifiedNickel-Plated Brass Locknut, Rubber O-Ring7875N18000000
     

    Stainless Steel Multi-Diameter Wet-Location Cable Entry Panels

    Modify these cable entry panels to get the right fit for your cord even when you don't know the exact diameter. They have a corrosion-resistant frame with a two-piece rubber insert that fits around cables with connectors. The insert is made of layers that you peel away until you reach the size that fits your cord.
    Knockout Mount
    Image of Product. Front orientation. Cable Entry Panels. Stainless Steel Multi-Diameter Wet-Location Cable Entry Panels.
    NEMA 4X Enclosure Rating, NEMA 13 Enclosure Rating, and IP67 Enclosure Rating—Panels are rated NEMA 4X and NEMA 13 for indoor and outdoor protection against corrosion, water projected from a hose, and oil/coolant spraying, and IP67 for temporary water submersion.
    Shape
    For Cord OD (No.
    of Cords)
    For Knockout
    Trade Size
    Thread
    Type
    For Max.
    Panel Thk.
    Temp. Range,
    ° F
    Features
    Enclosure Rating
    Certification
    Each
    Stainless Steel
    Straight0.37" to 1.28"M63
    Metric
    0.16"-40 to 140Stainless Steel Locknut, Two-Piece Blue Rubber InsertsNEMA 4X, NEMA 13, IP67
    UL Listed
    6995K10000000
     
    Replacement Inserts

    Round Wet-Location Multi-Diameter Cable Entry Panels

    Modify these cable entry panels to get the right fit for your cord even when you don't know your exact cord diameter. They have a corrosion-resistant frame with a two-piece rubber insert that fits around cables with connectors. The insert is made of layers that you peel away until you reach the size that fits your cord.
    Replacement inserts allow you to change cord sizes and configurations.
    Knockout Mount
    Image of Product. For 4 Cords. Front orientation. For 4 Total Cords. Round Wet-Location Multi-Diameter Cable Entry Panels.
    Image of Product. For 9 Cords. Front orientation. For 9 Total Cords. Round Wet-Location Multi-Diameter Cable Entry Panels.

    For 4 Cords

    For 9 Cords

    NEMA 4X Enclosure Rating, NEMA 13 Enclosure Rating, IP66 Enclosure Rating, and IP67 Enclosure Rating—Panels are rated NEMA 4X and NEMA 13 for indoor and outdoor protection against corrosion, water projected from a hose, and oil/coolant spraying, and IP66 and IP67 for protection from washdowns and temporary water submersion.
    For Total
    No. of Cords
    Shape
    For Cord OD (No.
    of Cords)
    For Knockout
    Trade Size
    Thread
    Type
    For Max.
    Panel Thk.
    Temp. Range,
    ° F
    Features
    Enclosure Rating
    Certification
    Each
    Stainless Steel
    4Straight0.14" to 0.65"M63
    Metric
    0.16"-40 to 140Stainless Steel Locknut, Two-Piece Blue Rubber InsertsNEMA 4X, NEMA 13, IP66, IP67
    UL Listed
    6995K20000000
    9Straight0.14" to 0.41"M63
    Metric
    0.16"-40 to 140Stainless Steel Locknut, Two-Piece Blue Rubber InsertsNEMA 4X, NEMA 13, IP66, IP67
    UL Listed
    6995K3000000
     
    Replacement Inserts

    Screw-Down Liquid-Tight Plastic Cord Grips

    Image of Product. Front orientation. Cord Grips. Screw-Down Liquid-Tight Plastic Cord Grips.
    For an extra-secure hold, these cord grips have both a compression seal and a clamp that screws down onto your cord when tightened. They're sealed with an O-ring, making them IP and NEMA rated to block out dust and water, even during washdowns. A locknut anchors them in the knockout.
    For Cord OD
    For Knockout
    Trade Size
    Material
    Enclosure Rating
    Temp. Range,
    ° F
    For Cord
    Shape
    Specs. Met
    Features
    Each
    Straight
     
    Metric Thread
    1.45" to 1.73"M63
    NylonIP68, IP69K, NEMA 4X, NEMA 6
    0 to 155RoundUL 94 V-0, CE Marked, DNV-GL Type ApprovedNylon Plastic Locknut, Rubber O-Ring1013N2220000000
     
    back to top