McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    13 Products

    DIN-Panel-Mount Electrically Actuated Counters with Output Relay

    Image of Product. Front orientation. Counters. DIN-Panel-Mount Electrically Actuated Counters with Output Relay .
    For quick installation, this counter fits standard DIN panel cutouts. Wire it up to an electrical pulse-emitting switch, sensor, or encoder for use on machine tools, packaging machinery, or other equipment. An output relay sends a signal to another device when the counter reaches a set point. The signal can start/stop a process or trigger an alarm. A gasket provides protection from direct water sprays (meets IP65). UL Recognized Component, C-UL Recognized Component, and CE marked, this counter meets American, Canadian, and European safety standards.
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    No. of Set
    Points
    Max. Counts
    per min.
    DIN
    Size
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Includes
    Input Voltage Range
    Output Relay Current
    @ Input Voltage
    Features
    Enclosure
    Rating
    Certification
    Housing
    Material
    Each
    Press On
     
    Screw Terminals
    YesDown, Up611,5001/161.77"1.77"1.9"1.9"3.1"Gasket12V AC to 250V AC, 12V DC to 250V DC0.5 amp @ 230V AC
    2 amp @ 30V DC
    Battery-Powered DisplayIP65
    UL Recognized Component, C-UL Recognized Component, CE Marked
    Plastic00000000000000
     

    DIN-Panel-Mount Electrically Actuated Counters

    Image of Product. Front orientation. Counters. DIN-Panel-Mount Electrically Actuated Counters , Press On.
    Image of Product. Front orientation. Counters. DIN-Panel-Mount Electrically Actuated Counters , Screw On.

    Press On

    Screw On

    For quick installation, these counters fit standard DIN panel cutouts. Wire them up to an electrical pulse-emitting switch, sensor, or encoder for use on machine tools, packaging machinery, or other equipment.
    Press On—Press-on counters have a front panel that is rated NEMA 4 and IP66 for protection against dust and washdowns and outdoor use. The screw terminals are rated IP20.
    Screw On—Screw-on counters are rated NEMA 4X, NEMA 12, and IP65 for protection against dust, water, and splashing oil and coolant.
    Backlit Display—Counters with backlit display have good visibility in low-light conditions.
    For Panel
    Cutout
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts
    per min.
    DIN
    Size
    Ht.
    Wd.
    Overall
    Dp.
    Input Voltage
    Features
    Enclosure Rating
    Each
    Press On
     
    Screw Terminals
    YesUp81,2001/320.87"1.77"2"24V AC to 240V AC/24V DC to 240V DC (High Level)
    0V AC to 2V AC/0V DC to 2V DC (Low Level)
    Battery-Powered DisplayNEMA 4, IP20, IP66
    00000000000000
    YesUp860,0001/320.87"1.77"2"4.5V DC to 30V DC (High Level)
    0V DC to 2V DC (Low Level)
    Battery-Powered DisplayNEMA 4, IP20, IP66
    0000000000000
     
    Screw On
     
    Screw Terminals
    YesDown, Up86001/320.87"1.77"2.1"10V AC to 240V AC (High Level)
    10V DC to 110V DC (Low Level)
    Backlit Display, Battery-Powered DisplayNEMA 4X, NEMA 12, IP65
    000000000000
    YesDown, Up8600,0001/320.87"1.77"2.1"18V DCBacklit Display, Battery-Powered DisplayNEMA 4X, NEMA 12, IP65
    000000000000
     

    Combination Switch-Contact/Electrically Actuated Counters

    Image of Product. Front orientation. Counters. Combination Switch-Contact/Electrically Actuated Counters , Screw On, Style A.
    Image of Product. Front orientation. Counters. Combination Switch-Contact/Electrically Actuated Counters , Screw On, Style B.

    Screw On

    Style A

    Screw On

    Style B

    You can set these counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. Count backup maintains the count if power is lost.
    Password Lockout—Password lockout prevents tampering and accidental loss of data.
    Programming Backup—Counters with programming backup maintain settings if power is lost.
    Scaling Function—A scaling function lets you adjust the unit of measure to suit your application.
    For Panel
    Cutout
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min.
    (Input Method)
    DIN
    Size
    Ht.
    Wd.
    Overall
    Dp.
    Input Voltage
    Operating
    Voltage
    Includes
    Features
    Enclosure
    Rating
    Certification
    Each
    Screw On
     
    Screw Terminals
    AYesUp6600,000 (Voltage),
    600,000 (Switch Contact)
    1/320.87"1.77"2.4"4V DC to 30V DC (High Level),
    0V DC to 1V DC (Low Level)
    10V DC to 30V DCCount BackupNEMA 4X, IP65
    CE Marked
    00000000000000
    AYesUp and Down6600,000 (Voltage),
    600,000 (Switch Contact)
    1/320.87"1.77"2.4"4V DC to 30V DC (High Level),
    0V DC to 1V DC (Low Level)
    10V DC to 30V DCCount Backup, Scaling FunctionNEMA 4X, IP65
    CE Marked
    0000000000000
    BYesDown, Up61,200,000 (Voltage),
    1,200,000 (Switch Contact)
    1/81.77"3.62"3.3"0V DC to 12V DC120V ACCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    0000000000000
    BYesDown, Up61,200,000 (Voltage),
    1,200,000 (Switch Contact)
    1/81.77"3.62"3.3"0V DC to 12V DC120V AC12V DC Power Source for External SensorCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    0000000000000
     

    DIN-Panel-Mount Counters/Ratemeters

    Image of Product. Front orientation. Counters. DIN-Panel-Mount Counters/Ratemeters .
    For quick installation, these counters/ratemeters fit a standard 1/8 DIN panel cutout. Wire them up to an electrical pulse-emitting switch, sensor, or encoder to count input while tracking rates in units such as gallons per minute. The scaling function lets you adjust the unit of measure to suit your application. Counters are protected from dust and washdowns and can be used outdoors (rated NEMA 4X).
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min. (Input Method)
    DIN
    Size
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Input Voltage,
    V DC
    Operating
    Voltage
    Includes
    Enclosure
    Rating
    Certification
    Each
    Screw On
     
    Screw Terminals
    YesUp and Down62,000,000 (Voltage), 2,000,000 (Switch Contact)1/81.77"3.62"2"3.8"4.2"0 to 3085V AC to 250V AC12V DC Power Source for External SensorNEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    00000000000000
    YesUp and Down62,000,000 (Voltage), 2,000,000 (Switch Contact)1/81.77"3.62"2"3.8"4.2"0 to 3011V DC to 36V DC12V DC Power Source for External SensorNEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    0000000000000
     
    Output Relays