    21 Products

    Long-Life Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Long-Life Pressure-Regulating Valves for Cryogenic Liquids.
    For a longer service life than standard valves for cryogenic liquids, these have a durable bronze body. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves are designed to withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. They have an internal strainer to trap debris.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Bronze Body—Bronze Diaphragm and PTFE Seal with Internal Strainer
    1/4
    Side4001/4
    SideScrew3 1/16"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 30
    ,
    75 to 250
    49165K390000000
    1/2
    Side4001/2
    SideScrew4 1/2"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 30
    ,
    20 to 75
    ,
    20 to 100
    ,
    50 to 250
    49165K59000000
    1
    Side4001
    SideScrew5 7/8"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 35
    ,
    20 to 60
    ,
    20 to 100
    ,
    75 to 250
    49165K79000000
     

    Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Pressure-Regulating Valves for Cryogenic Liquids.
    These valves can withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Brass Body—Bronze Diaphragm and PTFE Seal
    1/4
    Side6001/4
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    15 to 65
    ,
    75 to 175
    ,
    100 to 250
    47435K310000000
    3/8
    Side6003/8
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    15 to 65
    ,
    75 to 175
    ,
    100 to 250
    47435K32000000
     

    Vacuum Breakers for Chemicals

    A plastic body withstands pH neutralizing, cleaning, and plating solutions containing sodium hydroxide, methyl ethyl ketone, and other harsh chemicals. Also known as vacuum-breaking valves, these valves have vents that open when pressure drops to relieve vacuum conditions and prevent backward suction from drawing liquid into upstream piping.
    Diaphragm Check Valve
    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers for Chemicals.
    Material
    CPVC Body
    PVC Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    For Pipe
    Schedule
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Min. Opening
    Pressure, psi
    End-to-End
    Lg.
    Seal
    DIaphragm
    For Use With
    Temp. Range,
    ° F
    Color
    Each
    Temp. Range,
    ° F
    Color
    Each
    NPT Female Inlet × NPT Female Outlet
    1/2
    1/2
    80
    Not Rated100 psi @ 75° F14 5/16"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N13000000040 to 140Gray1868N10000000
    3/4
    3/4
    80
    Not Rated100 psi @ 75° F14 5/8"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N1400000040 to 140Gray1868N11000000
    1
    1
    80
    Not Rated100 psi @ 75° F15 1/8"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N1500000040 to 140Gray1868N12000000
     
    Spring-Loaded Piston Check Valve
    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers for Chemicals.
    Material
    CPVC Body
    PVC Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    For Pipe
    Schedule
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Min. Opening
    Pressure, psi
    End-to-End
    Lg.
    Seal
    Piston
    Spring
    For Use With
    Temp. Range,
    ° F
    Color
    Each
    Temp. Range,
    ° F
    Color
    Each
    NPT Female Inlet × NPT Female Outlet
    1 1/2
    1 1/2
    80
    Not Rated100 psi @ 75° F17 15/16"Fluoroelastomer
    CPVC
    PolymerBeverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N180000000———0
    2
    2
    80
    Not Rated100 psi @ 75° F18 1/2"Fluoroelastomer
    PVC
    PolymerBeverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon———040 to 140Gray1868N170000000
     

    Fast-Acting Pressure-Relief Valves for Cryogenic Liquids

    Cleaned and bagged for oxygen service and other high-purity applications, these valves can withstand the extreme cold of liquid argon, liquid nitrogen, and liquid oxygen. They spring fully open at the set pressure and remain open until the system pressure is restored below the set pressure. All have a vented relief port to exhaust discharge directly.
    NPT Male Inlet and Relief Vent
    Image of Product. Front orientation. Pressure-Relief Valves. Fast-Acting Pressure-Relief Valves for Cryogenic Liquids.
    Inlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Relief Port
    Location
    Shape
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Valve
    Type
    Choose a Set Pressure, psi
    Each
     
    Brass Body—PTFE Seal
    1/4
    Bottom400Side90° Elbow2 5/16"Liquid Argon, Liquid Nitrogen, Liquid Oxygen-320 to 350Pop Safety
    5
    ,
    10
    ,
    15
    ,
    20
    ,
    25
    ,
    30
    ,
    40
    ,
    50
    ,
    88
    ,
    100
    ,
    110
    ,
    125
    ,
    150
    ,
    200
    ,
    220
    ,
    250
    ,
    300
    ,
    325
    ,
    350
    ,
    400
    9137K11000000
     

    Pressure-Relief Valves for Cryogenic Applications

    Image of Product. Front orientation. Pressure-Relief Valves. Pressure-Relief Valves for Cryogenic Applications.
    Cleaned and bagged to meet CGA G-4.1 for oxygen service and other high-purity applications, these valves are built to withstand the extreme cold of liquid carbon dioxide, liquid nitrogen, and liquid oxygen. They begin opening at the set pressure and fully open at about 10% over the set pressure. Valves begin closing as pressure drops and fully close when the system pressure is restored below the set pressure. Set pressure is not adjustable. Valves are not intended for direct contact with cryogenic liquids.
    Riser Tubes—Riser tubes (sold separately) are required to convert cryogenic liquids into gases before they contact the valve. 3/8 NPT valve requires a 1/2 NPT × 3/8 NPT bushing when using a riser.
    Adapters—Adapters (sold separately) convert the valve relief-port connection from UNEF female threads to NPT female threads.
    Valves
    Riser Tubes
    Adapters
    Inlet
    Relief
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Port Thread
    Size
    Port
    Location
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Choose a Set Pressure, psi
    Each
    Each
    Each
    NPT Male Inlet and UNEF Female Relief Port
     
    Brass Body
    1/4
    Bottom6003/4"-20
    Top2 5/8"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 165
    22
    ,
    35
    ,
    50
    ,
    75
    ,
    100
    ,
    125
    ,
    150
    ,
    200
    ,
    250
    ,
    300
    ,
    350
    ,
    400
    ,
    450
    49315K7100000049315K9700000049315K94000000
    3/8
    Bottom6003/4"-20
    Top2 5/8"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 165
    22
    ,
    35
    ,
    50
    ,
    75
    ,
    100
    ,
    125
    ,
    150
    ,
    200
    ,
    250
    ,
    300
    ,
    350
    ,
    400
    ,
    450
    49315K720000049315K980000049315K9400000
    1/2
    Bottom6003/4"-20
    Top2 13/16"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 165
    22
    ,
    35
    ,
    50
    ,
    75
    ,
    100
    ,
    125
    ,
    150
    ,
    200
    ,
    250
    ,
    300
    ,
    350
    ,
    400
    ,
    450
    49315K730000049315K980000049315K9600000
     
    back to top