    Long-Life Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Long-Life Pressure-Regulating Valves for Cryogenic Liquids.
    For a longer service life than standard valves for cryogenic liquids, these have a durable bronze body. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves are designed to withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. They have an internal strainer to trap debris.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Bronze Body—Bronze Diaphragm and PTFE Seal with Internal Strainer
    1/4
    Side4001/4
    SideScrew3 1/16"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 15010 to 30, 75 to 25049165K390000000
    1/2
    Side4001/2
    SideScrew4 1/2"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 15010 to 30, 20 to 75, 20 to 100, 50 to 25049165K59000000
    1
    Side4001
    SideScrew5 7/8"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 15010 to 35, 20 to 60, 20 to 100, 75 to 25049165K79000000
     

    Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Pressure-Regulating Valves for Cryogenic Liquids.
    These valves can withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Brass Body—Bronze Diaphragm and PTFE Seal
    1/4
    Side6001/4
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 15015 to 65, 75 to 175, 100 to 25047435K310000000
    3/8
    Side6003/8
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 15015 to 65, 75 to 175, 100 to 25047435K32000000
     

    Compact Threaded Flow-Adjustment Valves for Cryogenic Liquid

    Often used with portable cryogenic cylinders, these valves are a third of the height of other valves for cryogenic liquid. They are designed to withstand the extreme cold of liquid argon, liquid carbon dioxide, and liquid nitrogen; all are cleaned and bagged to meet CGA G-4.1 standards for oxygen service. These valves gradually open and close with multiple turns of the wheel handle to adjust and regulate flow. They have a nonrising stem that stays in the same position whether the valve is open or closed.
    Brass Body—Straight
    Image of Product. Front orientation. Flow-Adjustment Valves. Compact Threaded Flow-Adjustment Valves for Cryogenic Liquid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Overall
    Pipe
    Size
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Ht.
    Lg.
    Temp. Range,
    ° F
    Seat
    Material
    Packing
    Material
    End-to-End
    Lg.
    Stem
    Type
    For Use With
    Valve
    Type
    Specs.
    Met
    Each
    NPT Female × NPT Female
    1/4 1600 psi @ 165° F3 1/4"2 1/2"-320 to 165PCTFEPTFE
    2 1/2"NonrisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.168075K810000000
    3/8 1.8600 psi @ 165° F3 1/4"2 1/2"-320 to 165PCTFEPTFE
    2 1/2"NonrisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.168075K82000000
    1/2 1.8600 psi @ 165° F3 1/4"2 1/2"-320 to 165PCTFEPTFE
    2 1/2"NonrisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.168075K83000000
     

    Threaded Flow-Adjustment Valves for Cryogenic Liquid

    Designed to withstand the extreme cold of liquid argon, liquid carbon dioxide, and liquid nitrogen, these valves are cleaned and bagged to meet CGA G-4.1 standards for oxygen service. They gradually open and close with multiple turns of the wheel handle to adjust and regulate flow. All have a rising stem that lifts as the valve opens and lowers as the valve closes to provide a visual indication of whether flow is on or off.
    Bronze Body—Straight
    Image of Product. Front orientation. Flow-Adjustment Valves. Threaded Flow-Adjustment Valves for Cryogenic Liquid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Overall
    Pipe
    Size
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Ht.
    Lg.
    Temp. Range,
    ° F
    Seal Material
    Seat
    Material
    Packing
    Material
    End-to-End
    Lg.
    Stem
    Type
    For Use With
    Valve
    Type
    Specs.
    Met
    Each
    NPT Female × NPT Female
    1/2 3.3600 psi @ 150° F8 5/16"2 5/8"-325 to 150Glass-Filled PTFEPTFEPTFE
    2 5/8"RisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.149415K320000000
    3/4 6.3400 psi @ 150° F10"3 3/16"-325 to 150Glass-Filled PTFEPTFEPTFE
    3 3/16"RisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.149415K43000000
    110600 psi @ 150° F11 13/16"3 3/4"-325 to 150Glass-Filled PTFEPTFEPTFE
    3 3/4"RisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.149415K34000000
    1 1/2 26400 psi @ 150° F16 1/2"4 3/4"-325 to 150Glass-Filled PTFEPTFEPTFE
    4 3/4"RisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.149415K36000000
    2 45600 psi @ 150° F16 3/4"5 3/4"-325 to 150Glass-Filled PTFEPTFEPTFE
    5 3/4"RisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.149415K3800000000
     
    Stainless Steel Body
    Image of Product. Front orientation. Flow-Adjustment Valves. Threaded Flow-Adjustment Valves for Cryogenic Liquid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Overall
    Pipe
    Size
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Ht.
    Lg.
    Temp. Range,
    ° F
    Seal Material
    Seat
    Material
    Packing
    Material
    End-to-End
    Lg.
    Stem
    Type
    For Use With
    Valve
    Type
    Specs.
    Met
    Each
    NPT Female × NPT Female
    1/2 5720 psi @ 150° F11 13/16"4"-325 to 150Glass-Filled PTFEPCTFEPTFE
    3 1/16"RisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.149415K420000000
    114720 psi @ 150° F12 1/16"4"-325 to 150Glass-Filled PTFEPCTFEPTFE
    3 15/16"RisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.149415K44000000
    1 1/2 53720 psi @ 150° F12 5/16"5"-325 to 150Glass-Filled PTFEPCTFEPTFE
    5"RisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.149415K46000000
    2 28.3720 psi @ 150° F12 5/8"5"-325 to 150Glass-Filled PTFEPCTFEPTFE
    5 15/16"RisingLiquid Argon, Liquid Carbon Dioxide, Liquid NitrogenGlobeCGA G-4.149415K4800000000
     

    Fast-Acting Pressure-Relief Valves for Cryogenic Liquids

    Cleaned and bagged for oxygen service and other high-purity applications, these valves can withstand the extreme cold of liquid argon, liquid nitrogen, and liquid oxygen. They spring fully open at the set pressure and remain open until the system pressure is restored below the set pressure. All have a vented relief port to exhaust discharge directly.
    NPT Male Inlet and Relief Vent
    Image of Product. Front orientation. Pressure-Relief Valves. Fast-Acting Pressure-Relief Valves for Cryogenic Liquids.
    Inlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Relief Port
    Location
    Shape
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Valve
    Type
    Choose a Set Pressure, psi
    Each
     
    Brass Body—PTFE Seal
    1/4
    Bottom400Side90° Elbow2 5/16"Liquid Argon, Liquid Nitrogen, Liquid Oxygen-320 to 350Pop Safety5, 10, 15, 20, 25, 30, 40, 50, 88, 100, 110, 125, 150, 200, 220, 250, 300, 325, 350, 4009137K11000000
     

    Flanged Flow-Adjustment Valves for Chemicals

    With seats that can stand up to aggressive and corrosive solutions, these valves are often used in chemical-processing applications. They bolt to flanges for adjusting and regulating flow in flanged pipelines.
    Wafer Valves with Lockable Lever Handle
    Image of Product. Front orientation. Flow-Adjustment Valves. Flanged Flow-Adjustment Valves for Chemicals, Wafer Valves with Lockable Lever Handle, 4 Bolt Holes.
    Image of Product. Front orientation. Flow-Adjustment Valves. Flanged Flow-Adjustment Valves for Chemicals, Wafer Valves with Lockable Lever Handle, 8 Bolt Holes.

    4 Bolt Holes

    8 Bolt Holes

    Wafer valves must be sandwiched between two flanges; they have tabs or unthreaded holes to help align the valve between the flanges.
    Lockable lever handles have 10 flow-adjustment positions. The handle can be fixed in place with a padlock (not included).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    For Use With
    For Max. Shackle
    Dia.
    Pressure
    Class
    Flange
    OD
    Bolt Circle
    Dia.
    No. of Bolt
    Holes
    Bolt Hole
    Size
    Bolts
    Included
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    End-to-End
    Lg.
    Valve
    Type
    Seat Material
    Specs. Met
    Each
    Ductile Iron Body—316 Stainless Steel Disc
    2 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    6"4 3/4"43/4"NoNot Rated250 psi @ 210° F-20 to 2101 13/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K240000000
    2 1/2 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    7"5 1/2"43/4"NoNot Rated250 psi @ 210° F-20 to 2101 15/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K25000000
    3 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    7 1/2"6"43/4"NoNot Rated250 psi @ 210° F-20 to 2101 15/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K26000000
    4 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    9"7 1/2"83/4"NoNot Rated250 psi @ 210° F-20 to 2102 3/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K27000000
    5 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    10"8 1/2"87/8"NoNot Rated250 psi @ 210° F-20 to 2102 5/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K2800000000
    6 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    11"9 1/2"87/8"NoNot Rated250 psi @ 210° F-20 to 2102 5/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K2900000000
     
    Wafer Valves with Wheel Handle
    Image of Product. Front orientation. Flow-Adjustment Valves. Flanged Flow-Adjustment Valves for Chemicals, Wafer Valves with Wheel Handle.
    Wafer valves must be sandwiched between two flanges; they have tabs or unthreaded holes to help align the valve between the flanges.
    Wheel handles open and close with multiple turns, providing fully adjustable flow.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    For Use With
    Pressure
    Class
    Flange
    OD
    Bolt Circle
    Dia.
    No. of Bolt
    Holes
    Bolt Hole
    Size
    Bolts
    Included
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    End-to-End
    Lg.
    Valve
    Type
    Seat Material
    Specs. Met
    Each
    Ductile Iron Body—316 Stainless Steel Disc
    6 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid125, 150
    11"9 1/2"87/8"NoNot Rated250 psi @ 210° F-20 to 2102 5/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K54000000000
    8 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid125, 150
    13 1/2"11 3/4"87/8"NoNot Rated250 psi @ 210° F-20 to 2102 1/2"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K5500000000
     
    Lug Valves with Lockable Lever Handle
    Image of Product. Front orientation. Flow-Adjustment Valves. Flanged Flow-Adjustment Valves for Chemicals, Lug Valves with Lockable Lever Handle, 4 Bolt Holes.
    Image of Product. Front orientation. Flow-Adjustment Valves. Flanged Flow-Adjustment Valves for Chemicals, Lug Valves with Lockable Lever Handle, 8 Bolt Holes.

    4 Bolt Holes

    8 Bolt Holes

    Lug valves can be sandwiched between two flanges or bolted directly to a single flange for servicing one end of the pipeline without depressurizing the other side. They have threaded flange holes with a hole pattern that matches ANSI flanges of the same pipe size.
    Lockable lever handles have 10 flow-adjustment positions. The handle can be fixed in place with a padlock (not included).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    For Use With
    For Max. Shackle
    Dia.
    Pressure
    Class
    Flange
    OD
    Bolt Circle
    Dia.
    No. of Bolt
    Holes
    Bolt Hole
    Size
    Bolts
    Included
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    End-to-End
    Lg.
    Valve
    Type
    Seat Material
    Specs. Met
    Each
    Ductile Iron Body—316 Stainless Steel Disc
    2 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    6"4 3/4"43/4"NoNot Rated250 psi @ 210° F-20 to 2101 13/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K710000000
    2 1/2 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    7"5 1/2"43/4"NoNot Rated250 psi @ 210° F-20 to 2101 15/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K72000000
    3 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    7 1/2"6"43/4"NoNot Rated250 psi @ 210° F-20 to 2101 15/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K73000000
    4 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    9"7 1/2"83/4"NoNot Rated250 psi @ 210° F-20 to 2102 3/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K74000000
    5 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    10"8 1/2"87/8"NoNot Rated250 psi @ 210° F-20 to 2102 5/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K7500000000
    6 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid1/4"125, 150
    11"9 1/2"87/8"NoNot Rated250 psi @ 210° F-20 to 2102 5/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K7600000000
     
    Lug Valves with Wheel Handle
    Image of Product. Front orientation. Flow-Adjustment Valves. Flanged Flow-Adjustment Valves for Chemicals, Lug Valves with Wheel Handle.
    Lug valves can be sandwiched between two flanges or bolted directly to a single flange for servicing one end of the pipeline without depressurizing the other side. They have threaded flange holes with a hole pattern that matches ANSI flanges of the same pipe size.
    Wheel handles open and close with multiple turns, providing fully adjustable flow.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    For Use With
    Pressure
    Class
    Flange
    OD
    Bolt Circle
    Dia.
    No. of Bolt
    Holes
    Bolt Hole
    Size
    Bolts
    Included
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    End-to-End
    Lg.
    Valve
    Type
    Seat Material
    Specs. Met
    Each
    Ductile Iron Body—316 Stainless Steel Disc
    6 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid125, 150
    11"9 1/2"87/8"NoNot Rated250 psi @ 210° F-20 to 2102 5/16"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K2000000000
    8 Carbon Dioxide, Gasoline, Liquid Carbon Dioxide, Phosphoric Acid125, 150
    13 1/2"11 3/4"87/8"NoNot Rated250 psi @ 210° F-20 to 2102 1/2"ButterflyFluoroelastomerAPI Std 609, MSS SP-675024K300000000
     

    Orifice Valves for Chemicals

    Made of PVC, these orifices have excellent resistance to a wide range of corrosive chemicals. Also known as flow restrictors and precision orifice valves, they are used to throttle, vent, bleed, or regulate the flow of liquids and gases. They automatically adjust to changing inlet pressure to maintain consistent outlet flow.
    PVC Body
    Image of Product. Front orientation. Orifice Valves. Orifice Valves for Chemicals.
    Lg.
    For Use With
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Choose an Outlet Water Flow
    Each
    NPT Female × NPT Female
     
    1/2 Pipe Size
    2 1/4"Air, Ammonia, Beverage, Carbon Dioxide, Diesel Fuel, Ethylene Glycol, Food, Hydrochloric Acid, Kerosene, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Nitric Acid, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Water120 psi @ 75° F40 to 1400.25 gpm, 0.5 gpm, 0.75 gpm, 1 gpm, 1.5 gpm, 2 gpm2272N530000000
     
    3/4 Pipe Size
    3 1/4"Air, Ammonia, Beverage, Carbon Dioxide, Diesel Fuel, Ethylene Glycol, Food, Hydrochloric Acid, Kerosene, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Nitric Acid, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Water120 psi @ 75° F40 to 1403 gpm, 4 gpm, 5 gpm, 6 gpm, 7 gpm, 8 gpm2272N3000000
     

    Vacuum Breakers for Chemicals

    A plastic body withstands pH neutralizing, cleaning, and plating solutions containing sodium hydroxide, methyl ethyl ketone, and other harsh chemicals. Also known as vacuum-breaking valves, these valves have vents that open when pressure drops to relieve vacuum conditions and prevent backward suction from drawing liquid into upstream piping.
    Diaphragm Check Valve
    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers for Chemicals.
    Material
    CPVC Body
    PVC Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    For Pipe
    Schedule
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Min. Opening
    Pressure, psi
    End-to-End
    Lg.
    Seal
    DIaphragm
    For Use With
    Temp. Range,
    ° F
    Color
    Each
    Temp. Range,
    ° F
    Color
    Each
    NPT Female Inlet × NPT Female Outlet
    1/2
    1/2
    80
    Not Rated100 psi @ 75° F14 5/16"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N13000000040 to 140Gray1868N10000000
    3/4
    3/4
    80
    Not Rated100 psi @ 75° F14 5/8"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N1400000040 to 140Gray1868N11000000
    1
    1
    80
    Not Rated100 psi @ 75° F15 1/8"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N1500000040 to 140Gray1868N12000000
     
    Spring-Loaded Piston Check Valve
    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers for Chemicals.
    Material
    CPVC Body
    PVC Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    For Pipe
    Schedule
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Min. Opening
    Pressure, psi
    End-to-End
    Lg.
    Seal
    Piston
    Spring
    For Use With
    Temp. Range,
    ° F
    Color
    Each
    Temp. Range,
    ° F
    Color
    Each
    NPT Female Inlet × NPT Female Outlet
    1 1/2
    1 1/2
    80
    Not Rated100 psi @ 75° F17 15/16"Fluoroelastomer
    CPVC
    PolymerBeverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray1868N180000000———0
    2
    2
    80
    Not Rated100 psi @ 75° F18 1/2"Fluoroelastomer
    PVC
    PolymerBeverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon———040 to 140Gray1868N170000000
     

    Pressure-Relief Valves for Cryogenic Applications

    Image of Product. Front orientation. Pressure-Relief Valves. Pressure-Relief Valves for Cryogenic Applications.
    Cleaned and bagged to meet CGA G-4.1 for oxygen service and other high-purity applications, these valves are built to withstand the extreme cold of liquid carbon dioxide, liquid nitrogen, and liquid oxygen. They begin opening at the set pressure and fully open at about 10% over the set pressure. Valves begin closing as pressure drops and fully close when the system pressure is restored below the set pressure. Set pressure is not adjustable. Valves are not intended for direct contact with cryogenic liquids.
    Riser Tubes—Riser tubes (sold separately) are required to convert cryogenic liquids into gases before they contact the valve. 3/8 NPT valve requires a 1/2 NPT × 3/8 NPT bushing when using a riser.
    Adapters—Adapters (sold separately) convert the valve relief-port connection from UNEF female threads to NPT female threads.
    Valves
    Riser Tubes
    Adapters
    Inlet
    Relief
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Port Thread
    Size
    Port
    Location
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Choose a Set Pressure, psi
    Each
    Each
    Each
    NPT Male Inlet and UNEF Female Relief Port
     
    Brass Body
    1/4
    Bottom6003/4"-20
    Top2 5/8"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 16522, 35, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 45049315K7100000049315K9700000049315K94000000
    3/8
    Bottom6003/4"-20
    Top2 5/8"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 16522, 35, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 45049315K720000049315K980000049315K9400000
    1/2
    Bottom6003/4"-20
    Top2 13/16"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 16522, 35, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 45049315K730000049315K980000049315K9600000
     