    M12 Connectors

    These connectors run the automated world, from robot arms and photoelectric sensors to PLCs, IO-Link devices, and Ethernet switches. The original metric circular connector, they continue to be the standard today. They screw together tightly to protect against contaminants and hold firm against high vibration. Each one has a coding that indicates a unique keyway, preventing mismated connection errors before they happen. The coding also tells you whether a connector can send power, control, or data. Some can send a combination of the three, reducing the need for multiple connectors.
    Plugs
    Image of Product. Shielded. Front orientation. Metric Circular Connectors. M12 Connectors, Plugs, Shielded.

    Shielded

    Shielded—Shielding blocks electrical noise from motors, drives, and other equipment, preventing erratic readings, false triggers, and data errors that cause downtime. Use these connectors near high-interference sources or anywhere with shielded cable, such as fieldbus networks, sensors, and encoders.
    Plugs
    Caps
    Coding
    No. of
    Poles
    Voltage,
    V AC
    Current,
    amp
    Wire Connection
    Method
    Enclosure
    Rating
    Each
    Each
    Shielded
    D
    4504Screw TerminalIP65, IP67
    8256T10000006897K73000000
     
    Sockets
    Image of Product. Front orientation. Metric Circular Connectors. M12 Connectors, Sockets, Shielded.

    Shielded

    Shielded—Shielding blocks electrical noise from motors, drives, and other equipment, preventing erratic readings, false triggers, and data errors that cause downtime. Use these connectors near high-interference sources or anywhere with shielded cable, such as fieldbus networks, sensors, and encoders.
    Sockets
    Caps
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Wire Connection
    Method
    Enclosure
    Rating
    Each
    Each
    Shielded
    D
    450V AC/60V DC1Screw TerminalIP67
    8256T660000006897K74000000
     
    Female Receptacles
    Image of Product. Front orientation. Metric Circular Connectors. M12 Connectors, Female Receptacles, Unshielded.

    Unshielded

    Receptacles
    Caps
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Mounting
    Thread Size
    Enclosure
    Rating
    Each
    Each
    Unshielded
    D
    4300V AC/300V DC41/2"-14
    IP69
    8256T580000006897K74000000
     
    Male Receptacles
    Image of Product. Front orientation. Metric Circular Connectors. M12 Connectors, Male Receptacles, Unshielded.

    Unshielded

    Receptacles
    Caps
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Mounting
    Thread Size
    Enclosure
    Rating
    Each
    Each
    Unshielded
    D
    4300V AC/300V DC41/2"-14
    IP69
    8256T560000006897K73000000
     
    Adapters
    Image of Product. Adapter. Front orientation. Metric Circular Connectors. M12 Connectors, Adapters.

    Adapter

    Socket
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Enclosure
    Rating
    Each
    M12 Socket × RJ45 Socket
    D
    448V AC/60V DC4IP65, IP67
    8256T3000000
     
    90° Elbow Adapters
    Image of Product. M12 Socket. Front orientation. Metric Circular Connectors. M12 Connectors, 90° Elbow Adapters.

    M12 Socket

    Socket
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Enclosure
    Rating
    Each
    M12 Socket × RJ45 Socket
    D
    448V AC/60V DC4IP65, IP67
    8256T2000000
     

    Ethernet Cords with M12 Connectors

    The M12 threaded ends on these cords seal out contaminants and resist coming loose from vibration better than the RJ45 ends on traditional Ethernet cords. Use them in tough, rugged environments to send high-speed data between sensors, switches, servers, computers, and PLCs not protected by control panels. These cords can power devices as they send data, as long as devices are Power over Ethernet (PoE) compatible. They are often used within Ethernet/IP, Profinet, and EtherCat systems. Their poles and keyways adhere to standard coding layouts, reducing the chance you’ll mismatch connections.
    All cords are backward compatible, so they work in networks that meet the same or lower ethernet cable category. For example, a Category 6 cord will work in a Category 5 network, but it will only run at the Category 5 speed.
    With either TPE or polyurethane rubber insulation, all cords stand up to harsh factory conditions, chemicals, and UV rays. All are also highly flexible, so they’re good for jobs with continuous motion, such as robotics.
    When mated, all cords are IP67 rated to protect against dust and temporary submersion.
    Straight M12 Plug × Straight M12 Plug
    Image of Product. D-Coded Plug × D-Coded Plug. Front orientation. Ethernet Cords. Ethernet Cords with M12 Connectors, Straight End, Plug, D Code.
    Image of Specification. D Code. Front orientation. D Code. Ethernet Cords with M12 Connectors, Plug.

    D-Coded Plug × D-Coded

    Plug

    D Code

    Unshielded—Use unshielded cords where signal interference is not a concern.
    Double Shielded—Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, preventing impact to transmission speeds and data.
    TPE Cord Insulation—TPE-insulated cords resist abrasion and won’t pit or crack from welding runoff.
    Polyurethane Rubber Cord Insulation—Oil-resistant polyurethane-rubber-insulated cords are free of halogen, so they’re safer than most plastic as they won’t release toxic fumes or corrode metal.
    IP65 Enclosure Rating—IP65-rated cords stand up to washdowns.
    IP66K Enclosure Rating—IP66K-rated cords stand up to high-pressure washdowns.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Temp. Range,
    ° F
    Certification
    Enclosure Rating
    Color
    Each
    D-Coded—Category 5e Ethernet Cable
    3410024
    0.24"TPE
    Unshielded
    -10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N18000000
    3410022
    0.21"Polyurethane Rubber
    Double Shielded
    Braid, Foil-20 to 190UL Recognized Component
    IP67
    Green4172T1100000
    6410022
    0.21"Polyurethane Rubber
    Double Shielded
    Braid, Foil-20 to 190UL Recognized Component
    IP67
    Green4172T1200000
    9 1/2410024
    0.24"TPE
    Unshielded
    -10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N1900000
    9 1/2410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N1100000
    13410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N1200000
    16410022
    0.21"Polyurethane Rubber
    Double Shielded
    Braid, Foil-20 to 190UL Recognized Component
    IP67
    Green4172T1300000
    16 1/2410024
    0.24"TPE
    Unshielded
    -10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N2100000
    23410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N1300000
    32410022
    0.21"Polyurethane Rubber
    Double Shielded
    Braid, Foil-20 to 190UL Recognized Component
    IP67
    Green4172T1400000
    32 1/2410024
    0.24"TPE
    Unshielded
    -10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N2200000
     
    Caps
    Straight M12 Plug × 90° Elbow M12 Plug
    Image of Product. D-Coded Plug × 90° Elbow D-Coded Plug. Front orientation. Ethernet Cords. Ethernet Cords with M12 Connectors, Straight End, 90° Elbow End, Plug, D Code.
    Image of Specification. D Code. Front orientation. D Code. Ethernet Cords with M12 Connectors, Plug.

    D-Coded Plug × 90°

    Elbow D-Coded Plug

    D Code

    90° elbow cords sit flush against equipment, so they fit behind machinery in areas where space is tight.
    Double Shielded—Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, preventing impact to transmission speeds and data.
    TPE Cord Insulation—TPE-insulated cords resist abrasion and won’t pit or crack from welding runoff.
    IP65 Enclosure Rating—IP65-rated cords stand up to washdowns.
    IP66K Enclosure Rating—IP66K-rated cords stand up to high-pressure washdowns.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Temp. Range,
    ° F
    Certification
    Enclosure Rating
    Color
    Each
    D-Coded—Category 5e Ethernet Cable
    3410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N27000000
    6 1/2410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N2800000
    9 1/2410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N2900000
    16 1/2410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N3100000
     
    Caps
    90° Elbow M12 Plug × 90° Elbow M12 Plug
    Image of Product. 90° Elbow Plug × 90° Elbow Plug. Front orientation. Ethernet Cords. Ethernet Cords with M12 Connectors, Plug, 90° Elbow End.
    Image of Specification. D Code. Front orientation. D Code. Ethernet Cords with M12 Connectors, Plug.

    90° Elbow Plug ×

    90° Elbow Plug

    D Code

    90° elbow cords sit flush against equipment, so they fit behind machinery in areas where space is tight.
    Double Shielded—Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, preventing impact to transmission speeds and data.
    TPE Cord Insulation—TPE-insulated cords resist abrasion and won’t pit or crack from welding runoff.
    IP65 Enclosure Rating—IP65-rated cords stand up to washdowns.
    IP66K Enclosure Rating—IP66K-rated cords stand up to high-pressure washdowns.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Temp. Range,
    ° F
    Certification
    Enclosure Rating
    Color
    Each
    D-Coded—Category 5e Ethernet Cable
    3410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N37000000
    6 1/2410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N3800000
    9 1/2410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N3900000
    16 1/2410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N4100000
    32 1/2410024
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N42000000
     
    Caps
    Straight M12 Plug × Straight M12 Socket—Internal Housing Thread
    Image of Product. D-Coded Plug × D-Coded Socket. Front orientation. Ethernet Cords. Ethernet Cords with M12 Connectors, , Plug, Straight End, D Code.
    Image of Specification. D Code. Front orientation. D Code. Ethernet Cords with M12 Connectors, .

    D-Coded Plug ×

    D-Coded Socket

    D Code

    Double Shielded—Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, preventing impact to transmission speeds and data.
    TPE Cord Insulation—TPE-insulated cords resist abrasion and won’t pit or crack from welding runoff.
    IP65 Enclosure Rating—IP65-rated cords stand up to washdowns.
    IP66K Enclosure Rating—IP66K-rated cords stand up to high-pressure washdowns.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Enclosure Rating
    Color
    Each
    D-Coded—Category 5e Ethernet Cable
    3410024
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N48000000
    6 1/2410024
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N4900000
    9 1/2410024
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N5100000
    16 1/2410024
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N5200000
    32 1/2410024
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-10 to 175UL Listed, C-UL Listed
    IP65, IP67, IP66K
    Blue7911N53000000
     
    Caps
    Straight M12 Plug × Wire Leads—External Thread
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M12 Connectors, Plug, Straight End, D Code.
    Image of Specification. D-Code Male. Front orientation. D Code. Ethernet Cords with M12 Connectors, External Thread.

    D Code

    D-Code Male

    Polyurethane Rubber Cord Insulation—Oil-resistant polyurethane-rubber-insulated cords are free of halogen, so they’re safer than most plastic as they won’t release toxic fumes or corrode metal.
    Cord
    3 ft. Long
    Cable Lead
    16 ft. Long
    Cable Lead
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    OD
    Insulation
    Material
    Wire Lead AWG (No.
    of Wires)
    Shielding
    Housing Material
    Housing Thread
    Size
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Each
    D-Coded—Category 5e Ethernet Cable
    41000.25"Polyurethane Rubber
    22 (4)Shielded
    Tin-Plated CopperM12 × 1 mm-20 to 190IP67
    8256T440000008256T61000000
     
    Caps
    90° Elbow M12 Plug × Wire Leads—External Thread
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M12 Connectors, Plug, 90° Elbow End, D Code.
    Image of Specification. D-Code Male. Front orientation. D Code. Ethernet Cords with M12 Connectors, External Thread.

    D Code

    D-Code Male

    90° elbow cords sit flush against equipment, so they fit behind machinery in areas where space is tight.
    Polyurethane Rubber Cord Insulation—Oil-resistant polyurethane-rubber-insulated cords are free of halogen, so they’re safer than most plastic as they won’t release toxic fumes or corrode metal.
    Cord
    3 ft. Long
    Cable Lead
    16 ft. Long
    Cable Lead
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    OD
    Insulation
    Material
    Wire Lead AWG (No.
    of Wires)
    Shielding
    Housing Material
    Housing Thread
    Size
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Each
    D-Coded—Category 5e Ethernet Cable
    41000.25"Polyurethane Rubber
    22 (4)Shielded
    Tin-Plated CopperM12 × 1 mm-20 to 190IP67
    8256T450000008256T63000000
     
    Caps
    Straight M12 Socket × Wire Leads—Internal Housing Thread
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M12 Connectors, , Straight End, D Code.
    Image of Specification. D-Code Female. Front orientation. D Code. Ethernet Cords with M12 Connectors, , Wire Lead Connection.

    D Code

    D-Code

    Female

    TPE Cord Insulation—TPE-insulated cords resist abrasion and won’t pit or crack from welding runoff.
    Cord
    5 ft. Long
    Cable Lead
    16 ft. Long
    Cable Lead
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    OD
    Insulation
    Material
    Wire Lead AWG (No.
    of Wires)
    Shielding
    Housing Material
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Enclosure
    Rating
    Each
    Each
    D-Coded—Category 5e Ethernet Cable
    41000.27"TPE
    24 (4)Shielded
    Nickel-Plated BrassM12 × 1 mm-10 to 175UL Recognized Component
    IP67
    8256T710000008256T72000000
     
    Caps

    Ethernet Cords with M12 and RJ45 Connectors

    To send high-speed data in tough, rugged environments, these cords have an M12 connector on one end that threads onto switches, sensors, and other devices prone to vibration. The other end has a traditional RJ45 plug that connects to Ethernet equipment, such as computers, IO modules, and programmable logic controllers (PLCs). These cords can also power devices as they send data, so you don’t need a separate power cord. But, the device must be Power over Ethernet (PoE) compatible. They’re often used with EtherNet/IP, Profinet, and EtherCAT systems. With TPE insulation, they stand up to bending in robotics applications. It also means they resist abrasion and won’t pit or crack from chemicals, sunlight, and welding runoff.
    Thanks to its threads and IP rating, the M12 end is water and dust tight when mated. Poles and keyways on its face adhere to standard coding layouts, which reduces the chance of mismatching connections.
    When choosing an Ethernet cord, make sure you match or exceed your network’s ethernet cable category. These cords are backward compatible—for example, a Category 6 cord will work in a Category 5 network, but it’ll only run at the Category 5 speed.
    Straight M12 Plug × Straight RJ45 Plug
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M12 and RJ45 Connectors, Plug, Straight End.
    Image of Specification. D Code. Front orientation. D Code. Ethernet Cords with M12 and RJ45 Connectors, Plug.

    D Code

    Unshielded—Use unshielded cords where signal interference is not a concern.
    Double Shielded—Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, maintaining their speed and data integrity.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Transmission
    Freq., MHz
    Voltage,
    V DC
    Current,
    amp
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Color
    Each
     
    D-Coded—Category 5e Ethernet Cable
    34100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T191000000
    34100100600.524
    0.31"TPE
    Unshielded
    M12 × 1 mm-10 to 175UL Listed, C-UL Listed
    Blue8482N1300000
    6 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T19200000
    9 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T90100000
    9 1/24100100600.524
    0.31"TPE
    Unshielded
    M12 × 1 mm-10 to 175UL Listed, C-UL Listed
    Blue8482N1400000
    134100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-10 to 175UL Listed, C-UL Listed
    Blue8482N1100000
    16 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T19300000
    16 1/24100100600.524
    0.31"TPE
    Unshielded
    M12 × 1 mm-10 to 175UL Listed, C-UL Listed
    Blue8482N1500000
    234100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-10 to 175UL Listed, C-UL Listed
    Blue8482N1200000
    24 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T90200000
    32 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T19400000
    32 1/24100100600.524
    0.31"TPE
    Unshielded
    M12 × 1 mm-10 to 175UL Listed, C-UL Listed
    Blue8482N1600000
    494100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T903000000
    65 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T904000000
     
    Caps
    90° Elbow M12 Plug × Straight RJ45 Plug
    Image of Product. 90° Elbow M12 Plug × RJ45 Plug. Front orientation. Ethernet Cords. Ethernet Cords with M12 and RJ45 Connectors, Straight End, 90° Elbow End, Plug.
    Image of Specification. D Code. Front orientation. D Code. Ethernet Cords with M12 and RJ45 Connectors, Plug.

    90° Elbow M12

    Plug × RJ45 Plug

    D Code

    Cords with a 90° elbow run along the side of equipment, so they fit behind machines and in tight spaces.
    Double Shielded—Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, maintaining their speed and data integrity.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Transmission
    Freq., MHz
    Voltage,
    V DC
    Current,
    amp
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Color
    Each
     
    D-Coded—Category 5e Ethernet Cable
    34100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T939000000
    9 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T94200000
    16 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T94300000
    24 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T94400000
    32 1/24100100301.524
    0.26"TPE
    Double Shielded
    Braid, FoilM12 × 1 mm-40 to 175UL Listed, C-UL Listed
    Blue4172T94500000
     
    Caps
    Straight M12 Socket × Straight RJ45 Plug—Internal Housing Thread
    Image of Product. M12 Socket x RJ45 Plug. Front orientation. Ethernet Cords. Ethernet Cords with M12 and RJ45 Connectors, , Straight End, Plug.
    Image of Specification. D Code. Front orientation. D Code. Ethernet Cords with M12 and RJ45 Connectors, .

    M12 Socket x RJ45 Plug

    D Code

    Double Shielded—Double-shielded cords have layers of braid and foil that block signal interference from nearby devices, maintaining their speed and data integrity.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Transmission
    Freq., MHz
    Voltage,
    V DC
    Current,
    amp
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Temp. Range,
    ° F
    Certification
    Color
    Each
     
    D-Coded—Category 5e Ethernet Cable
    34100100601.524
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    Blue8482N22000000
    6 1/24100100601.524
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    Blue8482N2300000
    9 1/24100100601.524
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    Blue8482N2400000
    16 1/24100100601.524
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    Blue8482N2500000
    32 1/24100100601.524
    0.26"TPE
    Double Shielded
    Braid, Foil-10 to 175UL Listed, C-UL Listed
    Blue8482N26000000
     
    Caps

    M8 Connectors

    Use these compact connectors in spaces where M12 connectors won't fit. They're often used in crowded, high-vibration areas such as robot arms and IO-Link devices with many connections. They also fit on miniature proximity and photoelectric sensors.
    Plugs
    Image of Product. Front orientation. Metric Circular Connectors. M8 Connectors, Plugs, Shielded.

    Shielded

    Shielded—Shielding blocks electrical noise from motors, drives, and other equipment, preventing erratic readings, false triggers, and data errors that cause downtime. Use these connectors near high-interference sources or anywhere with shielded cable, such as fieldbus networks, sensors, and encoders.
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Wire Connection
    Method
    Enclosure
    Rating
    Each
    Shielded
    D
    450V AC/60V DC4Insulation PiercingIP65, IP67
    6115N15000000
     
    Sockets
    Image of Product. Front orientation. Metric Circular Connectors. M8 Connectors, Sockets, Shielded.

    Shielded

    Shielded—Shielding blocks electrical noise from motors, drives, and other equipment, preventing erratic readings, false triggers, and data errors that cause downtime. Use these connectors near high-interference sources or anywhere with shielded cable, such as fieldbus networks, sensors, and encoders.
    Coding
    No. of
    Poles
    Voltage
    Current,
    amp
    Wire Connection
    Method
    Enclosure
    Rating
    Each
    Shielded
    D
    450V AC/60V DC4Insulation PiercingIP65, IP67
    6115N16000000
     

    Ethernet Cords with M8 Connectors

    Unlike the RJ45 ends on traditional Ethernet cords, the threaded M8 ends on these cords keep contaminants out and resist coming loose from vibration. They are often used with sensors, switches, I/O modules, and computers. Braided shielding protects against signal interference. Insulated with polyurethane rubber, these cords bend easily, so they are ideal for applications that require continuous flexibility such as robotics. They also resist oil. When mated, they are IP67 rated for protection from dust and temporary submersion.
    Straight M8 Plug × Straight M8 Plug
    Image of Product. D-Code. Front orientation. D Code. Ethernet Cords with M8 Connectors, Plug.
    Image of Product. D-Coded Plug × D-Coded Plug. Front orientation. Ethernet Cords. Ethernet Cords with M8 Connectors, Straight End, Plug, D Code.

    D-Code

    D-Coded Plug × D-Coded

    Plug

    D Code—D-coded cords are Power over Ethernet (POE) enabled to carry data and power within one cord.
    Cord
    Lg.,
    ft.
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Voltage
    Current,
    amp
    AWG
    OD
    Insulation
    Material
    Shielding
    Shield
    Type
    Temp. Range,
    ° F
    Enclosure
    Rating
    Color
    Each
    D-Coded—Category 5 Ethernet Cable
    3 1/4410050V AC/60V DC422
    0.2"Polyurethane Rubber
    Shielded
    Braid-20 to 175IP67
    Green6185N11000000
    6 1/2410050V AC/60V DC422
    0.2"Polyurethane Rubber
    Shielded
    Braid-20 to 175IP67
    Green6185N1200000
    16 1/4410050V AC/60V DC422
    0.2"Polyurethane Rubber
    Shielded
    Braid-20 to 175IP67
    Green6185N1300000
    32 3/4410050V AC/60V DC422
    0.2"Polyurethane Rubber
    Shielded
    Braid-20 to 175IP67
    Green6185N14000000
     
    Straight M8 Plug × Wire Leads—External Thread
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M8 Connectors, Plug, Straight End.
    Image of Product. D-Code. Front orientation. D Code. Ethernet Cords with M8 Connectors, External Thread.
    Image of Specification. A Code. Front orientation. External Thread. Ethernet Cords with M8 Connectors.

    D-Code

    A Code

    D Code—D-coded cords are Power over Ethernet (POE) enabled to carry data and power within one cord.
    Cord
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Face
    Dia.
    Voltage
    Current,
    amp
    Wire Lead
    AWG
    OD
    Insulation
    Material
    Cable Lead
    Lg., ft.
    Shielding
    Shield
    Type
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    D-Coded—Category 5 Ethernet Cable
    41000.27"50V AC/60V DC422
    0.25"Polyurethane Rubber
    3Shielded
    Braid, Foil-20 to 175IP67
    6115N11000000
    41000.27"50V AC/60V DC422
    0.25"Polyurethane Rubber
    6.5Shielded
    Braid, Foil-20 to 175IP67
    6115N1200000
    41000.27"50V AC/60V DC422
    0.25"Polyurethane Rubber
    16Shielded
    Braid, Foil-20 to 175IP67
    6115N1300000
    41000.27"50V AC/60V DC422
    0.25"Polyurethane Rubber
    32.5Shielded
    Braid, Foil-20 to 175IP67
    6115N14000000
     

    Food and Beverage Ethernet Cords with M12 Connectors

    FDA compliant to safely touch food and threaded for a tight hold, these cords won’t vibrate loose as they send high-speed data to sensors and other automated devices in food, beverage, and pharmaceutical plants. They stand up to brief submersion as well as high-heat washdowns and harsh cleaners common to food lines, thanks to their IP ratings, TPE insulation, and stainless steel and polypropylene housing. Their insulation also means they’re flexible and won’t break down from abrasion or UV exposure. Overall, they’re more rugged than traditional RJ45 cords.
    To reduce the risk of signal loss between equipment, these cords block signal interference from nearby devices. Poles and keyways on their face adhere to standard coding layouts, keeping you from mis-mating connections. D coded, these connectors are often used within Ethernet/IP, Profinet, and EtherCat systems. They can also power devices as they send data, so you don’t need a separate power cord. But, your device must be Power over Ethernet (PoE) compatible.
    When choosing an Ethernet connector, make sure you match or exceed your network’s ethernet cable category. These connectors are backward compatible—for example, a Category 6 connector will work in a Category 5 network, but it’ll only run at the Category 5 speed.
    Straight M12 Plug × Wire Leads—External Thread
    Image of Product. Front orientation. Ethernet Cords. Food and Beverage Ethernet Cords with M12 Connectors.
    Image of Specification. D Code. Front orientation. D Code. Food and Beverage Ethernet Cords with M12 Connectors, External Thread.

    D Code

    Cord
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Transmission
    Freq., MHz
    Voltage,
    V DC
    Current,
    amp
    OD
    Insulation
    Material
    Wire Lead
    AWG
    No. of
    Wires
    Shielding
    Housing Material
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Enclosure Rating
    Food Industry Std.
    Color
    Each
    9.5 ft. Long Cable Lead
     
    D-Coded—Category 5e Ethernet Cable
    41001006040.25"TPE
    22
    4Shielded
    Polypropylene, Stainless SteelM12 × 1 mm-40 to 220UL Listed
    IP65, IP68, IP69K
    FDA Compliant 21 CFR 177.2600
    Light Blue5658N11000000
     
    32.5 ft. Long Cable Lead
     
    D-Coded—Category 5e Ethernet Cable
    41001006040.25"TPE
    22
    4Shielded
    Polypropylene, Stainless SteelM12 × 1 mm-40 to 220UL Listed
    IP65, IP68, IP69K
    FDA Compliant 21 CFR 177.2600
    Light Blue5658N13000000
     

    I/O Modules

    Image of System. Components Sold Separately. Front orientation. Contains Annotated. I/O Modules.

    Components Sold Separately

    Create a system of sensors and actuators that you can remotely update, view measurements from, and receive error messages in real time. IO-Link systems minimize downtime by locating issues such as cut cables or dirty sensors quickly. They send only digital signals to your PLC, regardless of whether your sensors and actuators send digital or analog signals. Because these systems send digital signals, they’re more reliable and less prone to data error and signal loss than analog signals. It also means you don't have to use expensive shielded cables since they resist EMI.
    When retrofitting an existing system, you'll need to make sure your PLC can incorporate IO-Link. Check with your PLC manufacturer—most have hardware that allows you to upgrade your PLC to run IO-Link.
    Note: Sockets may have extra holes on their face that are not used.
    Modules
    Image of Product. Front orientation. I/O Modules. Modules, Surface Mount.

    Surface

    Mount

    Modules communicate between your sensors and actuators and your PLC. They are required. Setting memory automatically stores your settings and restores them once your device is back online. This eliminates needing to program a device again when you replace or fix it.
    Surface Mount—Surface mount modules let you mount modules on equipment such as tanks and conveyors. By mounting them on your equipment, you save space in your control cabinet. They use M12 connectors.
    IP66 Enclosure Rating—IP66 rated components withstand washdowns.
    IP67 Enclosure Rating—IP67 rated components can be temporarily submerged in water.
    IP69K Enclosure Rating—IP69K rated components hold up to high-pressure and high-temperature washdowns.
    Enclosure Rating—IP rated components block out dust and withstand some water, so they do not require an enclosure. Ports that are unused must be capped to maintain their rating.
    Input
    Output
    Communication
    Protocol
    No. of Device
    Ports
    Total No. of
    M12 Connections
    Type
    Signal
    Voltage,
    V DC
    No.
    of
    Type
    Signal
    Voltage,
    V DC
    Current,
    mA, amp
    No.
    of
    Operating
    Voltage, V DC
    Certification
    Each
    Surface Mount
     
    IP66, IP67
    IO-Link, EtherNet/IP47DigitalPNP0 to 308DigitalPNP300.3420 to 30UL Listed, C-UL Listed, CE Marked
    7585N130000000
    IO-Link, EtherNet/IP811DigitalPNP0 to 3016DigitalPNP300.3820 to 30UL Listed, C-UL Listed, CE Marked
    7585N14000000
    IO-Link, Profinet47DigitalPNP0 to 308DigitalPNP300.3420 to 30UL Listed, C-UL Listed, CE Marked
    7585N11000000
    IO-Link, Profinet811DigitalPNP0 to 3016DigitalPNP300.3820 to 30UL Listed, C-UL Listed, CE Marked
    7585N12000000
     
    IP66, IP67, IP69K
    IO-Link, EtherNet/IP47DigitalPNP0 to 308DigitalPNP300.3420 to 30UL Listed, C-UL Listed, CE Marked
    7585N19000000
    IO-Link, EtherNet/IP811DigitalPNP0 to 3016DigitalPNP300.3820 to 30UL Listed, C-UL Listed, CE Marked
    7585N21000000
    IO-Link, Profinet47DigitalPNP0 to 308DigitalPNP300.3420 to 30UL Listed, C-UL Listed, CE Marked
    7585N17000000
    IO-Link, Profinet811DigitalPNP0 to 3016DigitalPNP300.3820 to 30UL Listed, C-UL Listed, CE Marked
    7585N18000000
     