About Pressure Gauges
More
About Pressure Transmitters
More
Low-Pressure Differential Gauges with Digital Display

Measure small changes in air pressure with these hand-held gauges. They have a four-digit LCD display for easy reading of measurements. Gauges are commonly used to indicate clogged filters and to monitor fans and blowers.
- For Use With: Air, Natural Gas
- Accuracy: ±0.5% Full Scale (Not Graded)
Pressure Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | bar | Resolution, psi | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Ht. | Wd. | Batteries Included | Environmental Rating | Each | |
Barbed Tube Connection | |||||||||||||
0-30 | 0-2.069 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 0000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | |||||||||||||
0-30 | 0-2.069 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Optional Nylon Carrying Case | 0000000 | Each | 000000 |
- For Use With: Air, Natural Gas
- Accuracy: ±0.5% Full Scale (Not Graded)
Pressure Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
kPa | in. of H₂O | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Ht. | Wd. | Batteries Included | Environmental Rating | Each | |
Barbed Tube Connection | |||||||||||||
0-4.982 | 0-20 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 0000000 |
0-49.82 | 0-200 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | |||||||||||||
0-4.982 | 0-20 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
0-49.82 | 0-200 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Optional Nylon Carrying Case | 0000000 | Each | 000000 |
Differential Pressure and Vacuum Gauges with Digital Display
Gauges have a four-digit LCD display for easy reading of measurements. Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.

- For Use With: Air
- Accuracy: ±0.5% Full Scale (Not Graded)
Pressure Range | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | kPa | in. of H₂O | mbar | Vacuum Range, in. of Hg | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Batteries Included | Features | Each | |
Barbed Tube Connection | ||||||||||||||
0-0.723 | 0-4.982 | 0-20" | 0-49.82 | 1.471"-0 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 0000000 |
0-7.225 | 0-49.82 | 0-200" | 0-498.2 | 14.71"-0 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-20 | 0-137.9 | 0-553" | 0-1,379 | 40.72"-0 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | ||||||||||||||
0-0.723 | 0-4.982 | 0-20" | 0-49.82 | 1.471"-0 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-7.225 | 0-49.82 | 0-200" | 0-498.2 | 14.71"-0 | 0.1 | 30 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
0-20 | 0-137.9 | 0-553" | 0-1,379 | 40.72"-0 | 0.01 | 60 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
Differential Pressure Transmitters with Digital Display for Air
With a digital display and selectable differential pressure ranges, these transmitters are a versatile alternative to transmitters with dial indicators. Unlike a standard transmitter that has one wider differential pressure range, these transmitters have multiple ranges to choose from. The selectable pressure range means they are more accurate than standard transmitters since their accuracy applies to each small range rather than a single wide range. They can also be configured to output either current or voltage, while standard transmitters typically output one signal type. The digital display allows you to troubleshoot and monitor differential pressure at the source. Also known as transducers, they measure the difference in pressure between two inputs and convert it to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. They are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. All are rated UL 94 V-0, so they meet flammability standards. CE marked, they also meet European safety standards.
When measuring pressure in ductwork, pair them with a static pressure probe.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
Connect them using two wires when using the current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. For voltage output, connect them using three wires—two wires into the power supply and a separate wire to send a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
IP66 rated transmitters protect against dust and washdowns. NEMA 4X rated transmitters protect against dirt, weather, corrosion, and washdowns.
For technical drawings and 3-D models, click on a part number.

- For Use With: Air
- Accuracy: ±1%
- Tube Connection Type: Barbed
- Connection Material: Nylon Plastic
- Temperature Range: -4° to 158° F
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, in. of H2O | Max. Input Pressure, in. of H2O | Input Voltage | For Tube ID | Mounting Hardware Included | Dia. | No. of | Ht. | Dp. | Environmental Rating | Each | |
4-20 mA, 0-5V DC, 0-10V DC Output Signal—Screw Terminals | |||||||||||
Surface Mount | |||||||||||
0 to 0.1 0 to 0.15 0 to 0.25 0 to 0.5 | 99 | 10-36V DC | 1/8", 3/16", 1/4", 5mm, 6mm | No | 3/16" | 3 | 4 13/16" | 1 15/16" | IP66, NEMA 4X | 0000000 | 0000000 |
0 to 1 0 to 2 0 to 3 0 to 5 | 166 | 10-36V DC | 1/8", 3/16", 1/4", 5mm, 6mm | No | 3/16" | 3 | 4 13/16" | 1 15/16" | IP66, NEMA 4X | 0000000 | 000000 |
0 to 10 0 to 15 0 to 25 0 to 28 | 166 | 10-36V DC | 1/8", 3/16", 1/4", 5mm, 6mm | No | 3/16" | 3 | 4 13/16" | 1 15/16" | IP66, NEMA 4X | 0000000 | 000000 |
Differential Pressure Transmitters with Electronic Switch Outputs

- For Use With: Air, Hydraulic Fluid, Water
- Accuracy: ±0.5%
- Pipe Connection: NPT Female
- Housing Material: Glass-Reinforced Polyester
- Connection Material: 316L Stainless Steel
- Temperature Range: 14° to 158° F
Get the flexibility of a differential pressure transmitter and a switch in one. These transmitters can work as a traditional transmitter using an analog output but also have electronic switch outputs and IO Link compatibility, making them great for advanced automation applications. Also known as transducers, they measure the difference in pressure between two inputs and convert it to electrical signal. Connect them to your programmable logic controller or receiving device to monitor differential pressure remotely, activate automated controls, or trigger alarms when they reach the set pressure. A digital display lets you monitor the differential pressure and troubleshoot issues at the source. It rotates for readability.
You’ll often see these transmitters used to indicate a clogged filter or help maintain a certain pressure in HVAC systems, pumps, and cooling systems. NEMA and IP rated, they protect against dirt, dust, corrosion, weather, washdowns, and temporary submersion.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
For technical drawings and 3-D models, click on a part number.
Configurable Analog Transmitter Output | Configurable Digital Switch Output | Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, psi | Max. Input Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | No. of | Signal | No. of | Signal Type | Mounting Hardware Included | Dia. | No. of | Environmental Rating | Each | |
5-Pole Micro M12 Plug Connection | |||||||||||||||
0-15 | 2,500 | 15-32V DC | 1/4 | 4 13/16" | 3" | 1 | 0-10V DC, 4-20 mA | 2 | PNP, NPN | No | 3/16" | 2 | IP65, IP67, NEMA 4X, NEMA 6 | 0000000 | 000000000 |
0-100 | 2,500 | 15-32V DC | 1/4 | 4 13/16" | 3" | 1 | 0-10V DC, 4-20 mA | 2 | PNP, NPN | No | 3/16" | 2 | IP65, IP67, NEMA 4X, NEMA 6 | 0000000 | 00000000 |
0-500 | 2,500 | 15-32V DC | 1/4 | 4 13/16" | 3" | 1 | 0-10V DC, 4-20 mA | 2 | PNP, NPN | No | 3/16" | 2 | IP65, IP67, NEMA 4X, NEMA 6 | 0000000 | 00000000 |
Remote-Reading Airflow/Temperature Meters
With a probe on a cord, these meters access hard-to-reach places in duct. They display airflow and temperature simultaneously and can show airflow measurements on multiple scales, such as fpm, mph, and knots. Also known as anemometers.
Fan meters are also known as vane meters. Those with a built-in surface temperature thermometer also measure the temperature of hard-to-reach surfaces. Mini fan meters have a fan at the end of a telescoping probe. You can also use them to measure humidity.
Pilot tube meters measure a wider airflow range than other meters. They also measure differential pressure.
Telescoping tube meters are also known as hot wire meters. They have a probe that telescopes to reach into narrow openings.
Meters with an SD card data connection store timestamped readings on an SD card in Excel format, for easy datalogging and PC transfer. Meters with a 3.5 mm audio data connection can transmit data through a USB connection using a USB adapter cord (sold separately, except for Style C). Meters with a mini-USB and micro-USB connection type transmit data to your PC through the included cable.

Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Airflow | Temp. Range | Air Volume, cfm | Ht. | Wd. | Dp. | Probe Cable Lg., ft. | Data Connection Type | Batteries Included | Includes | Each | |
Measures Airflow and Temperature | |||||||||||
60-6,900 fpm 0.7-78.2 mph 0.6-68 kn 0.4-35 m/sec. 1-126 km/hr. | 32° to 158° F 0° to 70° C | __ | 7 3/16" | 2 7/8" | 1 7/8" | 3 | Standard SD Card | Yes | Carrying Case | 00000000 | 0000000 |
Measures Airflow, Temperature, and Air Volume | |||||||||||
80-5,906 fpm 0.9-67.2 mph 0.8-58.3 kn 0.4-30 m/sec. 1.4-108 km/hr. | 14° to 140° F -10° to 60° C | 0-9,999 | 7" | 2 7/8" | 1 5/16" | 4 | __ | Yes | Carrying Case | 00000000 | 000000 |
100-6,800 fpm 1.14-70 mph 1-60 kn 0.5-30 m/sec. 1.83-125 km/hr. | 32° to 175° F 0° to 80° C | 0-999,900 | 7" | 2 15/16" | 1 5/16" | 3 | 3.5 mm Audio | Yes | Carrying Case | 0000000 | 000000 |
Measures Airflow, Temperature, and Air Volume—With Calibration Certificate Traceable to NIST | |||||||||||
80-5,906 fpm 0.9-67.2 mph 0.8-58.3 kn 0.4-30 m/sec. 1.4-108 km/hr. | 14° to 140° F -10° to 60° C | 0-9,999 | 7" | 2 7/8" | 1 5/16" | 4 | __ | Yes | Carrying Case | 00000000 | 000000 |
100-6,800 fpm 1.14-70 mph 1-60 kn 0.5-30 m/sec. 1.83-125 km/hr. | 32° to 175° F 0° to 80° C | 0-999,900 | 7" | 2 15/16" | 1 5/16" | 3 | 3.5 mm Audio | Yes | Carrying Case | 00000000 | 000000 |
USB Adapter Cords for Meters with 3.5 mm Audio Connection | 0000000 | Each | 000000 |

Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Airflow | Temp. Range | Air Volume, cfm | Ht. | Wd. | Dp. | Probe Cable Lg., ft. | Batteries Included | Includes | Each | |
Measures Airflow, Temperature, and Air Volume | ||||||||||
80-5,906 fpm 0.9-67.2 mph 0.8-58.3 kn 0.4-30 m/sec. 1.4-108 km/hr. | 14° to 140° F -10° to 60° C | 0-999,999 | 7" | 2 7/8" | 1 5/16" | 4 | Yes | Carrying Case | 00000000 | 0000000 |

Overall | Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow | Temp. Range | Air Volume, cfm | Relative Humidity | Ht. | Wd. | Dp. | Dia. | Cable Lg., ft. | Max. Probe Extension, ft. | Data Connection Type | Batteries Included | Includes | Each | |
Measures Airflow, Temperature, Air Volume, Relative Humidity | ||||||||||||||
100-3,940 fpm 0.5-20 m/sec. | -4° to 140° F -20° to 60° C | 0-99,999 | 0-100% | 6 11/16" | 3" | 1 11/16" | 23/32" | 3 | 3 | 3.5 mm Audio | Yes | 3 ft. Long USB Adapter Cord, Carrying Case, Data-Recording Software | 00000000 | 0000000 |
USB Adapter Cords for Meters with 3.5 mm Audio Connection | 0000000 | Each | 000000 |

Overall | Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow | Temp. Range | Air Volume, cfm | Differential Pressure Range, psi | Ht. | Wd. | Dp. | Dia. | Cable Lg., ft. | Data Connection Type | Batteries Included | Includes | Each | |
Measures Airflow, Temperature, Air Volume, and Differential Pressure | |||||||||||||
200-15,733 fpm 2.25-178.66 mph 2-154.6 kn 1-80 m/sec. 3.5-288 km/hr. | 32° to 122° F 0° to 50° C | 0-99,999 | 0-0.73 | 8 3/16" | 2 7/8" | 1 7/8" | 11/32" | 3 | Mini USB-B | Yes | 3 ft. Long USB Cord, Carrying Case, Data-Recording Software, Two 3 ft. Long Pitot Tubes | 00000000 | 0000000 |

Overall | Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow | Temp. Range | Air Volume, cfm | Ht. | Wd. | Dp. | Dia. | Cable Lg., ft. | Max. Probe Extension, ft. | Data Connection Type | Batteries Included | Includes | Each | |
Measures Airflow and Temperature | |||||||||||||
40-3,900 fpm 0.5-40 mph 1-30 kn 0.2-20 m/sec. 0.7-70 km/hr. | 32° to 122° F 0° to 50° C | __ | 7" | 2 15/16" | 1 5/16" | 1/2" | 4 | 3 | 3.5 mm Audio | Yes | __ | 0000000 | 0000000 |
Measures Airflow and Temperature—With Calibration Certificate Traceable to NIST | |||||||||||||
40-3,900 fpm 0.5-40 mph 1-30 kn 0.2-20 m/sec. 0.7-70 km/hr. | 32° to 122° F 0° to 50° C | __ | 7" | 2 15/16" | 1 5/16" | 1/2" | 4 | 3 | 3.5 mm Audio | Yes | __ | 00000000 | 000000 |
Measures Airflow, Temperature, and Air Volume | |||||||||||||
40-3,300 fpm 0.5-30 mph 0.39-30 kn 0.2-10 m/sec. 0.7-60 km/hr. | 32° to 122° F 0° to 50° C | 0-1,270,000 | 8" | 3" | 1 1/2" | 1/2" | 4 | 3 | 3.5 mm Audio | Yes | __ | 0000000 | 000000 |
40-3,940 fpm 0.5-45 mph 1-31 kn 0.2-25 m/sec. 0.7-72 km/hr. | 32° to 122° F 0° to 50° C | 0-1,907,000 | 7 3/16" | 2 7/8" | 1 7/8" | 1/2" | 4 | 3 | Standard SD Card | Yes | Carrying Case | 00000000 | 000000 |
USB Adapter Cords for Meters with 3.5 mm Audio Connection | 0000000 | Each | 000000 |

Overall | Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow | Temp. Range | Air Volume, cfm | Ht. | Wd. | Dp. | Dia. | Cable Lg., ft. | Max. Probe Extension, ft. | Data Connection Type | Batteries Included | Includes | Each | |
Measures Airflow, Temperature, and Air Volume | |||||||||||||
60-5,904 fpm 0.7-67 mph 0.6-58.3 kn 0.3-30 m/sec. 1-108 km/hr. | 32° to 113° F 0° to 45° C | 0-999,900 | 7 5/8" | 2 11/16" | 1 5/16" | 1/16" | 5.5 | 2 1/2 | Micro USB-B | Yes | 3 ft. Long USB Cord, Carrying Case, Data-Recording Software | 00000000 | 0000000 |
Airflow/Temperature Meters


These versatile meters display airflow and one other measurement simultaneously. They’re also known as anemometers or vane meters. They can show airflow measurements on multiple scales, such as fpm, mph, and knots.
Foldable fan meters are small enough to fit in your pocket when closed, then extend to 9” when unfolded.
Meters with a 4” blade diameter give you more accurate readings on large HVAC ducts than meters with smaller blades.
Meters | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Lithium Batteries (1/Pkg.) | ||||||||||||
Measures | Airflow | Temp. Range | Relative Humidity | Dew Point, °F | Ht. | Wd. | Dp. | Blade Dia. | Batteries Included | Each | Pkg. | ||
Fan Meters | |||||||||||||
Airflow, Temperature | 40-5,900 fpm 0.2-30 m/sec. | 0° to 140° F -20° to 60° C | __ | __ | 10 1/2" | 4 1/4" | 2" | 4" | Yes | 00000000 | 0000000 | 000000 | 00 |
Airflow, Temperature, Relative Humidity, Dew Point | 40-5,900 fpm 0.2-30 m/sec. | 0° to 140° F -20° to 60° C | 1-99% | 32° to 122° | 10 1/2" | 4 1/4" | 2" | 4" | Yes | 00000000 | 000000 | 000000 | 00 |
Foldable Fan Meters | |||||||||||||
Airflow, Temperature | 100-5,500 fpm 1.1-60 mph 1-50 kn 0.5-20 m/sec. 1.8-100 km/hr. | 0° to 122° F -18° to 50° C | __ | __ | 5 1/4"-9" | 2 3/4" | 3/4" | 1" | Yes | 0000000 | 000000 | 0000000 | 00000 |
Airflow, Temperature, Relative Humidity, Dew Point | 100-5,500 fpm 1.1-60 mph 1-50 kn 0.5-20 m/sec. 1.8-100 km/hr. | 0° to 122° F -18° to 50° C | 10-95% | 32° to 122° | 5 1/4"-9" | 2 3/4" | 3/4" | 1" | Yes | 0000000 | 000000 | 0000000 | 0000 |
Foldable Fan Meters with Compass | |||||||||||||
Airflow, Temperature, Relative Humidity, Dew Point | 60-3,900 fpm 0.5-40 mph 0.4-30 kn 1.1-20 m/sec. 0.8-70 km/hr. | 5° to 120° F -15° to 50° C | 1-99% | -4° to 122° | 5 1/2"-9" | 1 3/4" | 1" | 1" | Yes | 00000000 | 000000 | 0000000 | 0000 |
Indoor Environmental Meters
Measure airflow, light, humidity, and temperature with a single, pocket-sized tool. These meters have built-in sensors that can detect multiple environmental factors in your plant or office. This helps you maintain safety compliance and track energy efficiency. A data hold function lets you freeze a measurement on the screen, giving you time to write it down. Additionally, they have the memory to store your high and low measurements. These meters are also known as hygro-thermo-anemometers.
They’re CE marked as compliant with European health, safety, and environmental standards.
Plug in an optional thermocouple probe to measure the surface temperatures of hard-to-reach areas, such as duct walls.

Light Measurement Range | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures | Airflow | For Light Technology | Footcandles | Lux | Relative Humidity | Temp. Range, °F | Display | Ht. | Wd. | Dp. | Blade Dia. | Batteries Included | Specifications Met | Each | |
Fan Meter | |||||||||||||||
Airflow, Light, Relative Humidity, Temperature | 80-5,905 fpm 0.95-65 mph 0.85-55 kn 0.4-25 mm/sec. 1.45-105 km/hr. | Halogen | 0-1,855 | 0-15,000 | 95% | 35° to 120° | LCD | 6" | 2 1/4" | 1 1/4" | 1" | Yes | CE Marked | 0000000 | 0000000 |

Thermocouple Type | Cable Lg., ft. | Temp. Range, °F | Each | |
K | 3 | -40° to 482° | 0000000 | 000000 |