McMaster-Carr logo
    Filter by
    Display Type
    Digital Display Type
    System of Measurement
    Pipe Size
    Industrial Info Compare
    Thread Type
    Industrial Info Compare
    Set Point Adjustability
    Operates On
    Fitting Connection
    Industrial Info Compare
    Output Digital Signal
    Connects To
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    45 Products
    About Pressure Switches
    industrial info icon

    Compare different types of pressure switches and learn how they work.

    Dual-Setpoint Electronic Pressure Switches with Digital Display

    Image of Product. Front orientation. Contains Inset. Pressure Switches. Dual-Setpoint Electronic Pressure Switches with Digital Display.
    Image of Specification. 4-Pole M12 Plug. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches with Digital Display.

    4-Pole

    M12

    Plug

    When these switches reach either of their two set pressures—both of which can be controlled from the display—they send digital signals to your programmable logic controller (PLC) to activate automated controls. This means you could turn on a pump at one setpoint if pressure drops too low and open a valve at another if pressure rises too high. These switches could also be used to signal an alarm before switching off a pump. For remote control and monitoring from your PLC or PC, connect an IO Link controller (not included). You’ll also need to set one of the outputs to use IO Link instead of a PNP or NPN signal.
    Change your setpoint, reset point, scaling, and other settings using the display’s buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point. The head rotates, so you can view the display from the best angle. To reduce stress on pipes in your pressure system, secure these switches against a wall or other structure with a mounting bracket (sold separately). Use these switches with an M12 cable (sold separately) to quickly connect and disconnect them.
    All are rated IP65 and IP67, so they seal out dust and water from washdowns and brief submersion. UL and C-UL listed, all meet U.S. and Canadian safety standards.
    Configurable
    Digital Output
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Digital
    Signal
    Control Communication
    Protocol
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection Material
    Measurement Unit
    For Use With
    Each
    M12 Connection with 4 Poles
     
    1/4 NPT Male Pipe
    0 to 14Adjustable145PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Inches of Mercury, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water3167K310000000
    0 to 36Adjustable290PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water3167K32000000
    0 to 360Adjustable1,015PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N11000000
    0 to 1,450Adjustable1,810PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N12000000
    0 to 3,600Adjustable7,250PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N13000000
    0 to 5,800Adjustable11,580PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N14000000
     
    Accessories for Pressure Switches

    Electronic Pressure Switches for Compressed Air

    Image of Product. Front orientation. Pressure Switches. Electronic Pressure Switches for Compressed Air.
    With a set pressure range that works for most air systems, these switches send signals when your air system reaches a set pressure to your programmable logic controller (PLC) to activate automated controls and alarms. All meet at least one American, Canadian, or European safety standard.
    Monitor your pressure on the display and change your setpoint, reset point, scaling, and other settings using the buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point.
    1 Configurable Output—Switches with a configurable output give you the flexibility to choose between PNP, NPN, or IO Link. IO Link lets you remotely control and monitor switches from your PLC or PC when you connect an IO Link controller (not included).
    IP65 Enclosure Rating—IP65 rated switches protect from dust and light rinsing.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    Wire
    Connection
    For Use With
    Enclosure
    Rating
    Each
    PNP Output Signal
     
    1/8 NPT Male Threaded Pipe
    0 to 145Adjustable145±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP40
    3167K18000000
     
    1/4" Female Push to Connect Tube
    0 to 145Adjustable145±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP40
    3167K2100000
     
    NPN Output Signal
     
    1/8 NPT Male Threaded Pipe
    0 to 145Adjustable145±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP40
    3167K1700000
     
    1/4" Female Push to Connect Tube
    0 to 145Adjustable145±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP40
    3167K1900000
     
    1 Configurable Output—PNP, NPN, IO-Link
     
    1/8 NPT Male Threaded Pipe
    0 to 145Adjustable145±0.2%35 mA @ 30V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP65
    3167K41000000
     
    1/8 BSPT Male Threaded Pipe
    0 to 145Adjustable145±0.2%35 mA @ 30V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP65
    3167K42000000
     
    M5 x 0.8 mm Female Pipe
    0 to 145Adjustable145±0.2%35 mA @ 30V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP65
    3167K44000000
     
    Square Panel-Mount Brackets

    Adjustable-Reset Pressure Switches with Digital Display

    Image of Product. Front orientation. Contains Annotated. Pressure Switches. Adjustable-Reset Pressure Switches with Digital Display.
    Kick off automated controls, signal alarms, or activate equipment based on pressure changes while checking the pressure, setpoint, and reset point on the display. The adjustable reset point lets you control the amount of pressure change, also known as deadband and differential, before the switch resets. Adjust it anywhere within the setpoint range. Turn the external adjustment knob by hand to set pressure quickly. These are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    To power the display, these switches need a separate electrical input from the one used for switching.
    These switches are IP and NEMA rated, so they’re dust tight and protected against water from washdowns and weather, as well as sprays of oil and coolant.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Wire
    Connection
    Connection
    Material
    For Use With
    Enclosure Rating
    Each
    110V AC Input Voltage
     
    1/4 NPT Male Pipe
    3 to 60Adjustable60120±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T210000000
    5 to 100Adjustable100200±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T22000000
    10 to 200Adjustable200400±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T23000000
    150 to 3,000Adjustable3,0004,500±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T24000000
     
    24V DC Input Voltage
     
    1/4 NPT Male Pipe
    10 to 200Adjustable200400±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T25000000
     

    Dual-Setpoint Electronic Pressure Switches for Compressed Air

    Compatible with most air systems, these switches send digital signals to a programmable logic controller (PLC) to trigger separate processes when they reach either of their two set pressures. For example, they’ll activate a compressor if the pressure is too low or a relief valve if the pressure is too high. Or use them to signal an alarm before switching off a compressor. Some of these switches also work with liquids and gases, so they can be built into hydraulic systems and wet or humid environments, such as cleaning lines.
    Monitor your pressure on the display and change your setpoints, reset points, scaling, and other settings using the buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point. Add a panel-mount bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
    Rated IP65, they seal out dust and water from washdowns. Switches are UL and C-UL recognized components and CE marked to meet American, Canadian, and European safety standards.
    Wire Lead Connection
    Image of Product. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches for Compressed Air.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Output Digital
    Signal
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
     
    External Adjustment
    15 to 150Adjustable150215PNP±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Inert Gas, NitrogenIP65
    C-UL Recognized Component, CE Marked, UL Recognized Component
    9330N110000000
     
    1/4 Threaded NPT Male Pipe
     
    External Adjustment
    15 to 150Adjustable150290PNP±0.2%35 mA @ 24V DC25 to 120304 Stainless SteelAir, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, WaterIP65
    C-UL Recognized Component, CE Marked, UL Recognized Component
    9330N12000000
    15 to 300Adjustable300580PNP±0.2%35 mA @ 24V DC25 to 120304 Stainless SteelAir, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, WaterIP65
    C-UL Recognized Component, CE Marked, UL Recognized Component
    9330N13000000
     
    Square Panel-Mount Brackets

    Electronic Pressure and Vacuum Switches for Compressed Air

    Image of Product. Front orientation. Pressure and Vacuum Switches. Electronic Pressure and Vacuum Switches for Compressed Air.
    Designed specifically for air systems, these switches send signals to your programmable logic controller (PLC) to activate controls or alarms when your system reaches a set pressure or vacuum. All meet at least one American, Canadian, or European safety standard.
    Monitor pressure, setpoint, and reset point on the digital display. Use the display’s buttons to change your settings. These switches have an adjustable reset point (also called adjustable deadband or differential), so you can control the amount of pressure or vacuum change before the switch resets. Choose anywhere within the setpoint range for your reset point.
    1 Configurable Output—Switches with 1 configurable output give you flexibility to choose between PNP, NPN, or IO-Link. When using IO-Link, you can remotely control and monitor your vacuum from your PLC or PC when you connect an IO-Link controller (not included).
    IP65 Enclosure Rating—IP65 rated switches protect from dust and light rinsing.
    Set Point
    Pressure,
    psi
    Vacuum,
    in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Switches (PNP)
     
    Wire Leads—1/8 NPT Male
    0 to 14 1/20 to 29Adjustable14.572±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Inert Gas, NitrogenIP40
    3875N11000000
     
    Switches with 1 Configurable Output (PNP, NPN, IO-Link)
     
    Wire Leads—1/8 NPT Male
    0 to 14 1/20 to 29Adjustable14.572±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Inert Gas, NitrogenIP65
    3875N1200000
     
    Square Panel-Mount Brackets

    Differential Pressure Transmitters with Electronic Switch Outputs

    Image of Product. Front orientation. Differential Pressure Transmitters. Differential Pressure Transmitters with Electronic Switch Outputs.
    Get the flexibility of a differential pressure transmitter and a switch in one. These transmitters can work as a traditional transmitter using an analog output but also have electronic switch outputs and IO Link compatibility, making them great for advanced automation applications. Also known as transducers, they measure the difference in pressure between two inputs and convert it to electrical signal. Connect them to your programmable logic controller or receiving device to monitor differential pressure remotely, activate automated controls, or trigger alarms when they reach the set pressure. A digital display lets you monitor the differential pressure and troubleshoot issues at the source. It rotates for readability.
    You’ll often see these transmitters used to indicate a clogged filter or help maintain a certain pressure in HVAC systems, pumps, and cooling systems. NEMA and IP rated, they protect against dirt, dust, corrosion, weather, washdowns, and temporary submersion.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
    Configurable Analog
    Transmitter Output
    Configurable
    Digital Switch Output
    Mounting
    Holes
    Connection
    Pressure Differential,
    psi
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    Ht.
    Wd.
    No.
    of
    Analog Signal
    No.
    of
    Digital
    Signal
    Mounting Hardware
    Included
    Dia.
    No.
    of
    Enclosure Rating
    For Use With
    Accuracy
    Pipe
    Material
    Temp. Range,
    ° F
    Each
    5 Poles M12 Plug In
     
    Glass-Filled Polyester Plastic Housing
    0 to 152,50015 to 321/4
    4 13/16"3"10 to 10V DC, 4 to 20 mA2PNP, NPNNo3/16"2IP65, IP67, NEMA 4X, NEMA 6
    Air, Hydraulic Fluid, Water±0.5%NPT Female316L Stainless Steel
    14 to 1584682N11000000000
    0 to 1002,50015 to 321/4
    4 13/16"3"10 to 10V DC, 4 to 20 mA2PNP, NPNNo3/16"2IP65, IP67, NEMA 4X, NEMA 6
    Air, Hydraulic Fluid, Water±0.5%NPT Female316L Stainless Steel
    14 to 1584682N1200000000
    0 to 5002,50015 to 321/4
    4 13/16"3"10 to 10V DC, 4 to 20 mA2PNP, NPNNo3/16"2IP65, IP67, NEMA 4X, NEMA 6
    Air, Hydraulic Fluid, Water±0.5%NPT Female316L Stainless Steel
    14 to 1584682N1300000000
     

    Electronic Vacuum Switches for Compressed Air

    Image of Product. Front orientation. Vacuum Switches. Electronic Vacuum Switches for Compressed Air.
    Specifically made for air systems, these switches send signals to your programmable logic controller (PLC) to trigger processes when they reach a set vacuum. Use them to turn equipment on or off, activate automated controls, or signal alarms. Check the vacuum on the display and change your setpoint, reset point, scaling, and other settings using the buttons. All switches meet at least one American, Canadian, or European safety standard.
    Vacuum Switches with 1 Configurable Output—Switches with configurable outputs give you flexibility to choose between PNP, NPN, or IO Link. When using IO Link, you can remotely control and monitor your vacuum from your PLC or PC when you connect an IO Link controller (not included).
    Adjustable—An adjustable reset point means you can control the amount of vacuum change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point.
    IP65 Enclosure Rating—IP65 rated switches protect against dust and light rinses.
    Digital
    Output
    Configurable
    Digital Output
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    No.
    of
    Signal
    Type
    Signal
    Type
    Control Communication
    Protocol
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Vacuum Switches
     
    Wire Leads—1/8 NPT Male Pipe Connection
    0 to 30Adjustable14.71PNP±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, NitrogenIP40
    8023N11000000
     
    Vacuum Switches with 1 Configurable Output
     
    Wire Leads—1/8 NPT Male Pipe Connection
    0 to 30Adjustable14.7PNP, NPNIO-Link±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, NitrogenIP65
    8023N12000000
     
    Square Panel-Mount Brackets

    Dual-Setpoint Electronic Pressure and Vacuum Switches for Compressed Air

    Image of Product. Front orientation. Pressure and Vacuum Switches. Dual-Setpoint Electronic Pressure and Vacuum Switches for Compressed Air.
    With two setpoints, these switches trigger different actions in your air system by sending signals to a programmable logic controller (PLC) when they reach one of their set pressures or vacuums. For example, they can activate one light when a system is pressurized and another when it’s under vacuum. They have an adjustable reset, so you can control the amount of pressure change before the switch resets. This pressure difference is also called deadband or differential. Choose a reset point anywhere within the setpoint range.
    Easily monitor your pressure or vacuum setpoint on the digital display. Use its buttons to adjust the settings and setpoint.
    These switches are rated IP65 to seal out dust and water from light rinses. They’re CE marked, UL and C-UL recognized components, and CSA certified to meet American, Canadian, and European safety standards.
    Set Point
    Pressure,
    psi
    Vacuum,
    in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Output Digital
    Signal
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Wire Lead Connection
     
    1/8 NPT Male
    0 to 14 1/20 to 29Adjustable14.572PNP±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Inert Gas, NitrogenIP65
    3878N110000000
     
    Square Panel-Mount Brackets

    Dual-Setpoint Electronic Vacuum Switches for Compressed Air

    Image of Product. Front orientation. Vacuum Switches. Dual-Setpoint Electronic Vacuum Switches for Compressed Air.
    Trigger two different processes in vacuum applications by sending signals to a programmable logic controller (PLC) when these switches reach one of their two set vacuums. Designed specifically for air systems, they can turn on a vacuum pump if the vacuum is too low or a valve if the vacuum is too high. Or use them to signal an alarm before switching off a pump. Check the vacuum on the display and change your setpoint, reset point, scaling, and other settings using the buttons.
    Adjustable—An adjustable reset means you can control the amount of pressure change before the switch resets. This pressure difference is commonly referred to as deadband and differential. Choose anywhere within the setpoint range for your reset point.
    IP65 Enclosure Rating—Rated IP65, these switches seal out dust and water from light rinses. They meet American, Canadian, and European safety standards since they’re UL and C-UL recognized components as well as CE marked.
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Output Digital
    Signal
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Wire-Lead
     
    1/8 NPT Male Pipe Connection
    0 to 30Adjustable14.672PNP±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, WaterIP65
    8054N110000000
     
    Square Panel-Mount Brackets

    Electronic Insertion-Mount Flow Switches

    Image of Product. Front orientation. Flow Switches. Electronic Insertion-Mount Flow Switches.
    Instead of disassembling your system for inline installation, thread these flow switches onto a mounting adapter (sold separately) and insert them into a pipe tee or pipe outlet. They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. These switches are accurate in any mounting position.
    IP65 rated switches protect against dust and washdowns. IP67 rated switches withstand temporary submersion.
    Flow Set Point
    1 13/16"
    Probe Length
    For Pipe Size
    For Liquids, gpm
    For Gas, scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1 Digital NPN Output Signal
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 19V DC
    250 mA @ 36V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N130000000
     
    1 Digital PNP Output Signal
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 36V DC
    250 mA @ 18V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N11000000
     
    2 Digital NPN Output Signal
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 19V DC
    250 mA @ 36V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N14000000
     
    2 Digital PNP Output Signal
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 36V DC
    250 mA @ 18V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N12000000
     
    Mounting Adapters

    Sanitary Electronic Insertion-Mount Flow Switches

    Image of Product. Front orientation. Flow Switches. Sanitary Electronic Insertion-Mount Flow Switches.
    Easy to clean and install, these flow switches are 3-A certified to meet sanitary design standards and insert into your line with a quick-clamp mounting adapter (sold separately). They have a smooth probe, and unlike flow switches that measure with a paddle or turbine, these don’t have moving parts for contaminants to get stuck in. Rated IP67 and IP69K, they withstand temporary submersion and high-temperature, high-pressure washdowns. The mounting adapter attaches to a quick-clamp tube tee or outlet (often called tri-clamp fittings) in your large-diameter tubing system using a gasket and clamp (not included), so you don't need to disassemble your line for inline installation. This mounting adapter is also easy to remove and clean.
    They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. They’re accurate in any mounting position.
    Flow Set Point
    13/16"
    Probe Length
    1 13/16"
    Probe Length
    For Tube
    OD
    For Liquids, gpm
    For Gas, scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Food Industry Std.
    Each
    Each
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1 Digital PNP Output Signal
    1 1/2"
    2"
    0.55 to 54.21
    0.97 to 96.37
    4.84 to 72.47
    8.59 to 128.84
    430 psi @ 70° F-10 to 20036250 mA @ 19V DC
    250 mA @ 36V DC
    3 5/16"IP67, IP69K
    C-UL Listed
    UL Listed
    CE Marked
    3-A Certified 74-07, FDA Compliant 21 CFR 177.2415
    4548N1100000004548N120000000
     
    Mounting Adapters
    back to top