McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    76 Products
    About Heat Lamps
    industrial info icon

    Explore heat lamps by comparing factors such as operating temperature, size of what you’re heating, and the addition of reflectors.

    Ceiling- and Wall-Mount Heat Lamps

    Image of Product. Front orientation. Contains Annotated. Heat Lamps. Ceiling- and Wall-Mount Heat Lamps.
    Mount these lamps to warm, cure, and dry large surfaces, positioning them horizontally 6”-8” from what you want to heat. They are also known as infrared and radiant heaters.
    Note: Do not use in hazardous locations, such as enclosed areas exposed to fumes.
    Heat Lamps
    Replacement
    Elements
    Wattage,
    W
    Wattage Percentage
    Tolerance
    Lg.
    Wd.
    Dp.
    Duty
    Cycle
    No. of Heating
    Elements
    Operating
    Temp., ° F
    Housing
    Material
    Reflector
    Material
    Mounting Fasteners
    Included
    Electrical
    Connection Type
    Temp. Setting
    Adjustability
    For Use
    Outdoors
    Each
    Each
    240V AC—Single Phase
    250-5% to 5%10"4"3 1/2"Continuous1756Aluminum
    SteelYesHardwireFixedNo3110K8100000003110K21000000
    400-5% to 5%10"4"3 1/2"Continuous1942Aluminum
    SteelYesHardwireFixedNo3110K820000003110K2200000
    650-5% to 5%10"4"3 1/2"Continuous11,156Aluminum
    SteelYesHardwireFixedNo3110K840000003110K2300000
    1,000-5% to 5%10"4"3 1/2"Continuous11,420Aluminum
    SteelYesHardwireFixedNo3110K850000003110K2400000
    1,300-5% to 5%20"4"3 1/2"Continuous21,156Aluminum
    SteelYesHardwireFixedNo3110K860000003110K2300000
    1,950-5% to 5%30"4"3 1/2"Continuous31,156Aluminum
    SteelYesHardwireFixedNo3110K880000003110K2300000
    2,000-5% to 5%20"4"3 1/2"Continuous21,420Aluminum
    SteelYesHardwireFixedNo3110K870000003110K2400000
    3,000-5% to 5%30"4"3 1/2"Continuous31,420Aluminum
    SteelYesHardwireFixedNo3110K890000003110K2400000
    4,000-5% to 5%40"4"3 1/2"Continuous41,420Aluminum
    SteelYesHardwireFixedNo3110K910000003110K2400000
    5,000-5% to 5%50"4"3 1/2"Continuous51,420Aluminum
    SteelYesHardwireFixedNo3110K920000003110K2400000
     

    Bench-Mount Heat Lamps

    Image of Product. Front orientation. Heat Lamps. Bench-Mount Heat Lamps.
    Image of Specification. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Clamp to the edge of a workbench or table and adjust the arm to direct heat where you need it. Position this lamp 10” to 14” from a surface to spot-dry paint, adhesive, and other coatings and fillers. It’s also known as an infrared and radiant heater.
    Note: Do not use in hazardous locations, such as enclosed areas exposed to fumes.
    Arm
    Reach
    For Max. Surface
    Thk.
    Dia.
    Dp.
    Duty Cycle
    On/Off Time
    Max. Wattage
    per Bulb, W
    Bulbs
    Included
    Bulb Rated
    Life, hr.
    Housing
    Material
    Reflector
    Material
    Electrical
    Connection
    No. of
    Blades
    NEMA
    Type
    Features
    Each
    Heat Lamps—120V AC (Single Phase)
    42"2"8"8"Intermittent20 Minutes On, 20 Minutes Off250Yes2,000SteelSteelStraight Blade35-15
    Bulb Guard, Vented Shade3349K510000000
     
    Accessories and Replacements for Heat Lamps

    Mobile Heat Lamps

    Roll these lamps to your work surface and position the head anywhere along the stand, 18”-30” from what you want to heat. Use for spot-drying paint, adhesive, and other surface coatings and fillers. They’re also known as infrared and radiant heaters.
    Note: Do not use in hazardous locations, such as enclosed areas exposed to fumes.
    Adjustable Temperature Setting
    Image of Product. Shown with Bulbs. Front orientation. Heat Lamps. Mobile Heat Lamps, Adjustable Temperature Setting.
    Image of Specification. Front orientation. NEMA 5-15.

    Shown with Bulbs

    NEMA

    5-15

    Regulate heat with three switch controls. These lamps are not for use with water-based primers or paint.
    For Bulb
    Stand
    O'all
    Bulbs Not Included
    Bulbs Included
    Dia.
    Dp.
    Duty Cycle
    Type
    Base Size
    Base
    Type
    Max. Wattage
    per Bulb, W
    Ht.,
    ft.
    Wd.
    Dp.
    Housing
    Material
    Electrical
    Connection
    No. of
    Blades
    NEMA
    Type
    No. of Bulbs
    Req.
    Each
    Each
    120V AC, 120V DC—Single Phase
    18"11"IntermittentIncandescentMedium (Standard Household)Screw In250626 1/2"30"SteelStraight Blade35-15
    73162K500000003162K110000000
     
    Accessories and Replacements for Heat Lamps
    Fixed Temperature Setting
    Image of Product. Front orientation. Heat Lamps. Mobile Heat Lamps, Fixed Temperature Setting.
    Image of Specification. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Image of Specification. Front orientation. NEMA 6-20.

    NEMA

    6-20

    Fixed-temperature lamps have a head that rotates for horizontal or vertical positioning.
    Heat Lamps
    Replacement
    Elements
    Stand
    O'all
    Wattage,
    W
    Lg.
    Wd.
    Dp.
    Duty Cycle
    Operating Temp.
    Range, ° F
    Ht.,
    ft.
    Wd.
    Dp.
    Housing
    Material
    Electrical
    Connection
    No. of
    Blades
    NEMA
    Type
    Each
    Each
    120V AC, 120V DC—Single Phase
    1,50036"3 1/2"3 1/2"Intermittent1,125 to 1,325626 1/2"30"SteelStraight Blade35-15
    1825K41100000001737K54000000
    2,00036"3 1/2"3 1/2"Intermittent1,125 to 1,325626 1/2"30"SteelStraight Blade35-15
    1825K190000001737K71000000
     
    240V AC, 240V DC—Single Phase
    1,50036"3 1/2"3 1/2"Intermittent1,125 to 1,325626 1/2"30"SteelStraight Blade36-20
    1825K4120000001737K6400000
    2,00036"3 1/2"3 1/2"Intermittent1,125 to 1,325626 1/2"30"SteelStraight Blade36-20
    1825K310000001737K72000000
     

    Long-Distance Ceiling- and Wall-Mount Heat Lamps

    Image of Product. Front orientation. Contains Annotated. Heat Lamps. Long-Distance Ceiling- and Wall-Mount Heat Lamps.
    Warm, cure, and dry from as far away as 8 ft. These lamps are also known as infrared and radiant heaters. Mount them horizontally using the included brackets, which let you tilt the lamps up to 60°.
    Note: Do not use in hazardous locations, such as enclosed areas exposed to fumes.
    Heat Lamps
    Replacement
    Elements
    Wattage,
    W
    Lg.
    Wd.
    Dp.
    Duty
    Cycle
    Operating
    Temp., ° F
    Housing
    Material
    Reflector
    Material
    Mounting Hardware
    Included
    Electrical
    Connection Type
    Includes
    Temp. Setting
    Adjustability
    For Use
    Outdoors
    Each
    Each
    120V AC, 120V DC—Single Phase
    75019"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K1200000001737K52000000
    1,00033"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K130000001737K5300000
    1,50033"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K160000001737K65000000
     
    240V AC, 240V DC—Single Phase
    75019"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K410000001737K6200000
    1,00033"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K420000001737K6300000
    1,50033"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K430000001737K66000000
    2,00039"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K440000001737K27000000
    3,00061 1/4"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K450000001737K28000000
     
    480V AC, 480V DC—Single Phase
    2,00039"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K840000001737K89000000
    3,00061 1/4"8 1/4"5 1/2"Continuous1,400SteelAluminum
    YesHardwireOutlet Box with 1/2 Trade Size KnockoutFixedYes1737K850000001737K91000000
     

    Ceiling- and Wall-Mount Plug-In Ultraviolet Curing Lamps

    Image of Product. Front orientation. Ultraviolet Curing Lamps. Ceiling- and Wall-Mount Plug-In Ultraviolet Curing Lamps.
    Cover large areas with this long lamp. Use for UV curing as well as leak detection, quality control inspection, and testing.
    Cannot Be Sold to Canada—They cannot be sold to Canada due to local regulations on mercury content.
    Electrical
    Mounting
    Hole
    Light Intensity @ Distance
    Wavelength,
    nm
    Lg.
    Wd.
    Ht.
    Max. Wattage
    per Bulb, W
    Bulbs
    Included
    Features
    Voltage,
    V AC
    Connection
    No. of
    Blades
    NEMA
    Type
    Cord Lg.,
    ft.
    Housing
    Material
    Dia.
    No.
    of
    Mounting Fasteners
    Included
    Cannot Be
    Sold To
    Each
    0.82 mW/cm² @ 12"
    2.16 mW/cm² @ 5"
    36519 3/4"6"4 1/4"15YesBuilt-In Reflector120Straight Blade35-15
    8Aluminum
    3/16"4NoCanada8337K110000000
    Replacement Ultraviolet Bulbs

    Battery-Powered Ultraviolet Curing Lamps

    Image of Product. Front orientation. Ultraviolet Curing Lamps. Battery-Powered Ultraviolet Curing Lamps, 6 1/4" High.
    Image of Product. Front orientation. Ultraviolet Curing Lamps. Battery-Powered Ultraviolet Curing Lamps, 9 1/2" High.

    6 1/4"

    High

    9 1/2" High

    Use these lamps for UV curing as well as leak detection, quality control inspection, and testing.
    Cannot Be Sold to Canada—They cannot be sold to Canada due to local regulatory limits on mercury content.
    Batteries
    Light Intensity
    @ Distance
    Wavelength,
    nm
    Lg.
    Wd.
    Ht.
    Bulb Type
    Max. Wattage
    per Bulb, W
    Bulbs
    Included
    Features
    Voltage,
    V DC
    Included
    No.
    Required
    Size
    Type
    Housing
    Material
    Cannot Be
    Sold To
    Each
    0.23 mW/cm² @ 3"3652"1"6 1/4"Ultraviolet/Incandescent4YesFlashlight Setting6No4AADisposablePlasticCanada6760T11000000
    1.65 mW/cm² @ 3"3659 1/2"2 3/4"9 1/2"Ultraviolet/Incandescent6YesFlashlight Setting12YesDisposablePlasticCanada8519T16000000
    Replacements for Ultraviolet Curing Lamps

    Screw-In Heat Lamps for Light Bulb Sockets

    Image of Product. Front orientation. Heat Lamps. Screw-In Heat Lamps for Light Bulb Sockets.
    Turn a light socket into a radiant heater. These lamps generate heat with a ceramic element rather than an infrared bulb. Position them 6”-8” from what you want to heat. Lamps are also known as infrared and radiant heaters.
    Note: Do not use in hazardous locations, such as enclosed areas exposed to fumes.
    Base
    Wattage,
    W
    Wattage Percentage
    Tolerance
    Dia.
    Dp.
    Duty
    Cycle
    Operating
    Temp., ° F
    Electrical
    Connection
    Temp. Setting
    Adjustability
    Dia.
    Type
    For Use
    Outdoors
    Each
    120V AC—Single Phase
    500-5% to 5%4 3/4"5"Continuous900Light Bulb BaseFixed1 1/16"MediumNo3110K93000000
     
    240V AC—Single Phase
    500-5% to 5%4 3/4"5"Continuous900Light Bulb BaseFixed1 1/16"MediumNo3110K9400000
     

    Ceiling- and Wall-Mount UV Inspection Lights

    Image of Product. Front orientation. Ultraviolet Inspection Lights. Ceiling- and Wall-Mount UV Inspection Lights.
    Shine UV light over large work areas to uncover leaks, cracks, and contaminants. These lights illuminate fluorescent dyes, particles, and other chemicals, making defects easy to spot. Fasten them to a wall or ceiling, so you’ll have both hands free to adjust what you’re inspecting or make repairs.
    Ultraviolet and LED Bulbs—Lights with an ultraviolet and LED bulb last longer, are more efficient, and generate less heat than lights with a fluorescent bulb.
    Cannot Be Sold To—Lights that cannot be sold to the listed areas are restricted due to local regulatory limits on mercury.
    Lights
    Replacement Bulbs
    Bulb
    Housing
    Electrical
    Lg.
    Wd.
    Dp.
    No.
    of
    Material
    Color
    Wattage,
    W
    Material
    Color
    Voltage,
    V AC
    Wavelength,
    nm
    Connection
    No. of
    Blades
    Cord Lg.,
    ft.
    Cannot Be
    Sold To
    Each
    Cannot Be
    Sold To
    Each
    Ultraviolet and Fluorescent Bulbs
    48"1 3/4"4"1GlassBlue40PlasticBlack120365Straight Blade23Canada8336K23000000Canada8311K53000000
     
    Ultraviolet and LED Bulbs
    48"2"4"1PlasticClear20PlasticBlack120395 to 410Straight Blade238336K22000008311K5200000
     

    Ultraviolet Curing Chambers

    Safely cure light-activated adhesives, coatings, and ink or strengthen 3D-printed resin parts with UV light in these enclosed chambers. Also known as flood curing, they evenly cure your parts. They work just like a microwave. Plug them in, set your time, and they’re ready to cure.
    Formlabs Ultraviolet and LED Chambers with Turntable
    Image of Product. Front orientation. Ultraviolet Curing Chambers. Formlabs Ultraviolet and LED Chambers with Turntable.
    Formlabs chambers can be preheated to save you curing time. While they’ll work on any resin 3D-printed parts, if you use them with parts made of Formlabs resins, you can choose preset cure times and temperature settings for consistent results.
    Chambers with a turntable rotate parts under the lights for even exposure while curing. Because these chambers use low-intensity LED bulbs and only operate when the door is closed, additional UV-protective glasses or clothing while using them are not required.
    Inside
    Overall
    Wavelength,
    nm
    Light Intensity
    @ Distance
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Dp.
    Wattage,
    W
    Cord Lg.,
    ft.
    Housing
    Material
    Each
    405Not Rated10 3/8"9 7/8"9 7/8"15 7/8"13 1/4"14"1506Plastic3521N2010000000
    Ultraviolet and LED Chambers with Turntable
    Image of Product. Front orientation. Ultraviolet Curing Chambers. Ultraviolet and LED Chambers with Turntable.
    Chambers with a turntable rotate parts under the lights for even exposure while curing. Because these chambers use low-intensity LED bulbs and only operate when the door is closed, additional UV-protective glasses or clothing while using them are not required.
    Inside
    Overall
    Wavelength,
    nm
    Light Intensity
    @ Distance
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Dp.
    Wattage,
    W
    Cord Lg.,
    ft.
    Housing
    Material
    Each
    405Not Rated17 3/4"15 3/4"15 3/4"24"19"17 3/4"905Aluminum
    3521N13000000000
    Ultraviolet Chambers with Shelf
    Image of Product. Front orientation. Ultraviolet Curing Chambers. Adjustable Shelf, Ultraviolet.
    Chambers with a shelf create a deep, consistent cure and work best with small and flat parts. You can position parts closer to the bulb with the adjustable shelf for a faster curing. To carefully cure sensitive parts, adjust the light intensity level. An automatic lamp shutter covers and reduces power to the bulb when you open the door. You should always wear UV-protective glasses and clothing when the system is turned on because of their high-intensity light. To remotely monitor and control these chambers, connect them to a computer or PLC.
    Cannot Be Sold to Canada—Chambers and replacement bulbs that cannot be sold to Canada are restricted by regulations on limiting mercury content.
    Chambers
    Replacement
    Bulbs
    Inside
    Overall
    Wavelength,
    nm
    Light Intensity
    @ Distance
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Dp.
    Max. Wattage
    per Bulb, W
    No. of Bulbs
    Included
    Cord Lg.,
    ft.
    Housing
    Material
    Includes
    Cannot Be
    Sold To
    Each
    Each
    320 to 390115 mW/cm² @ 3"9"9"10 1/4"19"12"16"40017 1/2Aluminum
    UV Protective GlassesCanada3521N110000000003521N120000000

    Hand-Held Heat Lamps

    Image of Product. Front orientation. Heat Lamps. Hand-Held Heat Lamps.
    Position these lamps at any angle to heat, dry, soften, or defrost. They’re also known as infrared and radiant heaters.
    Note: Do not use in hazardous locations, such as enclosed areas exposed to fumes.
    O'all
    Operating Temp.
    @ Distance
    Duty Cycle
    On/Off Time
    Max. Wattage
    per Bulb, W
    Bulbs
    Included
    Bulb Rated
    Life, hr.
    Dia.
    Ht.
    Dp.
    Housing
    Material
    Reflector
    Material
    Electrical
    Connection Type
    Electrical
    Connection
    No. of
    Blades
    Includes
    Features
    Temp. Setting
    Adjustability
    For Use
    Outdoors
    Each
    120V AC—Single Phase
    182° F @ 12"
    363° F @ 5"
    Intermittent30 Minutes On, 20 Minutes Off600Yes754"11 1/2"4 1/2"PlasticAluminum
    Plug InStraight Blade2Protective Dark GlassesSwivel HandleFixedNo3343K110000000
     
    Bulbs

    UV Inspection Flashlights

    Image of Product. Front orientation. Ultraviolet Inspection Lights. UV Inspection Flashlights, Style C.

    Style C

    Reveal leaks, cracks, and contaminants that you wouldn’t find with a typical flashlight. These flashlights use UV light to illuminate fluorescent dyes, particles, and other chemicals.
    Bulb
    Housing
    Batteries
    Style
    Dia.
    Lg.
    No.
    of
    Color
    Wattage,
    W
    Material
    Color
    Enclosure
    Rating
    Wavelength,
    nm
    Light Intensity @ Distance
    Included
    No.
    Required
    Size
    Type
    Each
    Ultraviolet and LED Bulbs
    C2 1/4"5 3/4"51Blue9Aluminum
    BlackIP65
    39543 mW/cm² @ 2", 45 mW/cm² @ 2"No3AADisposable8336K12000000
     

    Bench-Top Plug-In Ultraviolet Curing Lamps

    Image of Product. Front orientation. Ultraviolet Curing Lamps. Bench-Top Plug-In Ultraviolet Curing Lamps.
    Set the lamp on a bench top and the 360° rotating head directs light where you need it.
    Cannot Be Sold to Canada—It cannot be sold to Canada due to local regulatory limits on mercury content.
    Electrical
    Light Intensity @ Distance
    Wavelength,
    nm
    Dia.
    Lg.
    Wd.
    Ht.
    Max. Wattage
    per Bulb, W
    Bulbs
    Included
    Voltage,
    V AC
    Connection
    No. of
    Blades
    NEMA
    Type
    Cord Lg.,
    ft.
    Housing
    Material
    Cannot Be
    Sold To
    Each
    21.7 mW/cm² @ 2"
    8.9 mW/cm² @ 10"
    3655 1/2"8 1/2"4 1/4"6 1/4"100Yes120Straight Blade35-15
    8Aluminum
    Canada1447T17000000000
    21.7 mW/cm² @ 2"
    8.9 mW/cm² @ 10"
    3656"9 3/4"4 1/4"6 1/4"100Yes120Straight Blade35-15
    8PlasticCanada1447T1500000000
    Accessories and Replacements for Ultraviolet Curing Lamps

    Hand-Held Plug-In Ultraviolet Curing Lamps

    Image of Product. Front orientation. Ultraviolet Curing Lamps. Hand-Held Plug-In Ultraviolet Curing Lamps, Style A.
    Image of Product. Front orientation. Ultraviolet Curing Lamps. Hand-Held Plug-In Ultraviolet Curing Lamps, Style B.
    Image of Product. Replacement Bulb for Style A. Front orientation. Light Bulbs. Hand-Held Plug-In Ultraviolet Curing Lamps, For Style A.
    Image of Product. Replacement Bulb for Style B. Front orientation. Light Bulbs. Hand-Held Plug-In Ultraviolet Curing Lamps, For Style B.

    Style A

    Style B

    Replacement Bulb

    for Style A

    Replacement Bulb

    for Style B

    Designed for UV curing of small areas, these lamps also aid in leak detection, quality control inspection, and testing.
    Cannot Be Sold to Canada—They cannot be sold to Canada due to local regulatory limits on mercury content.
    Electrical
    Style
    Light Intensity @ Distance
    Wavelength,
    nm
    Dia.
    Lg.
    Wd.
    Ht.
    Max. Wattage
    per Bulb, W
    Bulbs
    Included
    Voltage,
    V AC
    Connection
    No. of
    Blades
    NEMA
    Type
    Cord Lg.,
    ft.
    Housing
    Material
    Cannot Be
    Sold To
    Each
    A1.3 mW/cm² @ 3"3652 3/4"2"7 3/4"4Yes120Straight Blade35-15
    8PlasticCanada8519T140000000
    B8 mW/cm² @ 2"
    1.8 mW/cm² @ 10"
    3656"9 3/4"90Yes120Straight Blade35-15
    8PlasticCanada1447T1800000000
    Replacement Ultraviolet Bulbs
    back to top