McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    45 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Duct-Rated Communication and Security System Cable

    Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
    Unshielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Unshielded.
    Use unshielded cable in applications where signal interference is not a concern.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    Specs. Met
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    222/2
    0.11"PVC
    WhitePVC
    Black, Red0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1100000000000000000000000000000
    22
    422/4
    0.13"PVC
    WhitePVC
    Black, Green, Red, White0 to 165CMP, CL3P
    UL Listed, C-UL Listed
    8280T1200000000000000000000000000
    22
    622/6
    0.16"PVC
    WhitePVC
    Black, Blue, Brown, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1300000000000000000000000000
    22
    822/8
    0.19"PVC
    WhitePVC
    Black, Blue, Brown, Green, Orange, Red, White, Yellow0 to 165CMP, CL3P
    UL 13, UL 4448280T1400000000000000000000000000
    22
    1222/12
    0.23"PVC
    WhitePVC
    Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow0 to 165CMP, CL3P
    UL 13, UL 4448280T1500000000000000000000000000
    18
    218/2
    0.14"PVC
    WhitePVC
    Black, Red0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1600000000000000000000000000
    18
    318/3
    0.15"PVC
    WhitePVC
    Black, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1700000000000000000000000000
    18
    418/4
    0.17"PVC
    WhitePVC
    Black, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1800000000000000000000000000
    18
    618/6
    0.21"PVC
    WhitePVC
    Black, Blue, Brown, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T1900000000000000000000000000
    16
    216/2
    0.16"PVC
    WhitePVC
    Black, Red0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T2100000000000000000000000000
    16
    416/4
    0.2"PVC
    WhitePVC
    Black, Green, Red, White0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T22000000000000000000000000000
    14
    214/2
    0.21"PVC
    WhitePVC
    Black, Red0 to 165CMP, CL3P
    ETL Listed, C-ETL Listed
    8280T2300000000000000000000000000
     
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Duct-Rated Communication and Security System Cable, Shielded.
    Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
    22
    222/2
    0.12"PVC
    WhitePVC
    Black, Red15 to 165Uninsulated Ground WireCMP, CL3P
    UL Listed
    8233T110000000000000000000000000000000
    22
    422/4
    0.15"PVC
    WhitePVC
    Black, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1200000000000000000000000000
    22
    822/8
    0.19"PVC
    WhitePVC
    Black, Blue, Brown, Green, Orange, Red, White, Yellow0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1300000000000000000000000000
    18
    218/2
    0.16"PVC
    WhitePVC
    Black, Red0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1400000000000000000000000000
    18
    318/3
    0.19"PVC
    WhitePVC
    Black, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1500000000000000000000000000
    18
    418/4
    0.2"PVC
    WhitePVC
    Black, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1600000000000000000000000000
    18
    618/6
    0.23"PVC
    WhitePVC
    Black, Blue, Brown, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T17000000000000000000000000000
    16
    216/2
    0.19"PVC
    WhitePVC
    Black, Red0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T1800000000000000000000000000
    16
    416/4
    0.22"PVC
    WhitePVC
    Black, Green, Red, White0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T19000000000000000000000000000
    14
    214/2
    0.22"PVC
    WhitePVC
    Black, Red0 to 165Uninsulated Ground WireCMP, CL3P
    ETL Listed, C-ETL Listed
    8233T2100000000000000000000000000
     

    Access Control Cable

    Wire multiple components in your security system using a single cable. This cable bundles together four color-coded cables that correspond to each part of an access point: the card reader, the door contact, the lock, and the exit sign. Each interior cable is labeled with the component it matches. All four interior cables have a layer of foil around them to prevent signal interference from nearby devices. Designated CMP, it has a flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. It’s also known as plenum cable. It’s rated FT6, so it meets requirements for preventing the spread of flames and smoke based on a timed test with material mounted to a horizontal tray.
    Shielded Stranded Wire
    Image of Product. Front orientation. Security Cable. Access Control Cable.
    Outer
    Jacket
    Inner
    Insulation
    Security Cable
    Use
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Flammability Rating
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    300V AC/300V DC
    Card Reader
    Door Contact
    Exit Sign
    Lock
    22
    22
    22
    18
    6
    2
    4
    4
    22/6
    22/2
    22/4
    18/4
    2.2 amp @ 86° F
    2.2 amp @ 86° F
    2.2 amp @ 86° F
    4 amp @ 86° F
    0.46"PVC
    YellowPVC
    Blue, Gray, Orange, White32 to 165CMP
    CSA C22.2 No. 0.3 FT65846N150000000000000000000000000000
     

    Outdoor Lead Wire

    The EPDM insulation on this wire won’t become brittle or crack from sunlight, humidity, rain, temperature changes, abrasion from dirt and debris, and other rough outdoor conditions. It meets Mine Safety and Health Administration (MSHA) standards for material quality.
    2,000V AC
    Image of Product. Side1 orientation. Lead Wire. Outdoor Lead Wire, 2,000V AC.
    DLO Cable—DLO wire carries higher voltages than SC wire, making it the better choice for heavy duty applications. Use it to run power to motors, cranes, and other equipment in shipyards, mines, and oil- and gas-drilling rigs. Also known as diesel locomotive cable, this wire was originally designed to wire trains. An outer layer of chlorinated polyethylene plastic (CPE) gives it increased resistance to chemicals, heat, and flames. It’s also rated RHW-2, so it can be used underground and in wet locations.
    UL 2556 FT4—All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT4 wire is mounted to a vertical tray during testing.
    AWG
    Current @
    Temp.
    OD
    Max. Temp.,
    ° F
    Outer Jacket
    Material
    Inner Insulation
    Material
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Stranded Wire
    12
    Not Rated0.21"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T24000000000000000000000000
    8
    55 amp @ 86° F0.33"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T260000000000000000000000
    6
    75 amp @ 86° F0.37"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T270000000000000000000000
    4
    95 amp @ 86° F0.44"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T2800000000000000000000000
    2
    130 amp @ 86° F0.5"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T2900000000000000000000000
    1/0
    170 amp @ 86° F0.65"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T31000000000000000000000000
    2/0
    195 amp @ 86° F0.69"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T3200000000000000000000000000
    4/0
    260 amp @ 86° F0.82"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T3300000000000000000000000000
     

    Duct-Rated Ethernet Cords

    Also known as plenum-rated cords, these CMP ethernet cords have flame-resistant, low-smoke insulation and can be used without conduit in ductwork and above a drop ceiling. The RJ45 plugs on each end connect to Ethernet equipment, such as computers, IO modules, and programmable logic controllers (PLCs). Not only do these cords transmit data, but they also power devices that are Power over Ethernet (PoE) compatible. They’re often used with EtherNet/IP, Profinet, and EtherCAT systems.
    Straight RJ45 Plug × Straight RJ45 Plug
    Image of Product. Front orientation. Ethernet Cords. Duct-Rated Ethernet Cords.
    Lg.,
    ft.
    Transmission
    Freq., MHz
    AWG
    Cord
    OD
    Cable
    Designation
    Shielding
    Temp. Range,
    ° F
    Color
    Each
     
    Category 6 Ethernet Cable
    1555023
    0.28"CMP
    Unshielded
    35 to 140Black5591N11000000
    2555023
    0.28"CMP
    Unshielded
    35 to 140Black5591N1200000
     

    Duct-Rated HDMI Video Cords

    Image of Product. Front orientation. HDMI Cords. Duct-Rated HDMI Video Cords.
    Run high-definition signals through duct, above drop ceilings, and below raised floors without using conduit. These cords are plenum rated, so their insulation resists fire and doesn’t produce smoke. Connect these cords to monitors, TVs, and projectors. Each end has both a standard HDMI plug and a micro-HDMI socket, so you can connect multiple devices to the cord at once. The plugs are gold plated to resist corrosion and maintain signals over time.
    Note: These cords only transmit signals in one direction. Ends are labeled “Source” or “Display” to help you install the cord.
    Standard HDMI Male Plug and Micro HDMI Female Socket × Standard HDMI Male Plug and Micro HDMI Female Socket
    Lg.,
    ft.
    Cord
    OD
    Cable
    Designation
    Color
    Each
    Flexible
    200.21"CMP
    Black5593N110000000
    300.21"CMP
    Black5593N12000000
    600.21"CMP
    Black5593N13000000
    1000.21"CMP
    Black5593N14000000
     

    Duct-Rated Oil-Resistant Ethernet Cable

    Image of Product. Front orientation. Ethernet Cable. Duct-Rated Oil-Resistant Ethernet Cable , Unshielded.

    Unshielded

    Also known as plenum cable, this cable is designated CMP, so it has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The oil-resistant FEP insulation protects wires as the cable moves from duct to equipment or machinery. It also resists UV light. It’s backward compatible so it works in networks that meet the same or a lower category.
    Outer
    Jacket
    Inner
    Insulation
    Per Ft.
    Ethernet Cable
    Category
    Transmission
    Freq., MHz
    AWG
    No. of
    Wires
    Cable
    AWG
    Max. Temp.,
    ° F
    OD
    Cable
    Designation
    Material
    Color
    Material
    Color
    Choose a Length, ft.
    1-99
    100-Up
    Unshielded Solid Wire
    5e
    35024
    824/8
    3000.19"CMP
    FEP
    BlackFEP
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    25, 50, 100, 300, 5009284T50000000000
    6
    35023
    823/8
    3000.21"CMP
    FEP
    BlackFEP
    Blue
    Blue/White
    Brown
    Brown/White
    Green
    Green/White
    Orange
    Orange/White
    25, 50, 100, 300, 5009284T900000000
     

    Duct-Rated Ethernet Cable

    Image of Product. Front orientation. Ethernet Cable. Duct-Rated Ethernet Cable , Unshielded.
    Image of Product. Front orientation. Ethernet Cable. Duct-Rated Ethernet Cable , Shielded.

    Unshielded

    Shielded

    Also known as plenum cable, this CMP cable has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to send data between computers, printers, servers, and switches in an office. It’s backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher ethernet cable category for a clearer signal.
    Unshielded—Use unshielded cable in applications where signal interference is not a concern.
    Shielded—Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Inner
    Insulation
    Per Ft.
    Ethernet Cable
    Category
    Transmission
    Freq., MHz
    AWG
    No. of
    Wires
    Cable
    AWG
    Max. Temp.,
    ° F
    OD
    Cable
    Designation
    Outer Jacket
    Material
    Material
    Color
    Choose an Outer Jacket Color
    Choose a Length, ft.
    1-499
    500-Up
    Unshielded Solid Wire
    5e
    35024
    824/8
    1650.21"CMP
    PVC
    FEP/Polyolefin BlendBlue
    Brown
    Green
    Orange
    White/Blue
    White/Brown
    White/Green
    White/Orange
    Blue, White25, 50, 100, 500, 1,0007365K290000000000
    6
    35023
    823/8
    1650.23"CMP
    PVC
    FEP/Polyolefin BlendBlue
    Brown
    Green
    Orange
    White/Blue
    White/Brown
    White/Green
    White/Orange
    Black, Blue, Gray, Green, White, Yellow25, 50, 100, 500, 1,0008245K4100000000
     
    Shielded Solid Wire with Uninsulated Ground Wire
    6
    25023
    823/8
    1400.29"CMP
    PVC
    FEP
    Blue
    Brown
    Green
    Orange
    White/Blue
    White/Brown
    White/Green
    White/Orange
    Gray25, 50, 100, 500, 1,0004265T300000000
     

    Duct-Rated Fire Alarm Cable

    Also known as plenum cable, this FPLP cable has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The insulation is also flame resistant for use in critical circuits such as fire alarm systems and smoke detectors.
    Unshielded—Use unshielded cable in applications where signal interference is not a concern.
    Shielded—Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    Unshielded Solid Wire
    Image of Product. Front orientation. Fire Alarm Cable. Duct-Rated Fire Alarm Cable , Unshielded.
     
    300V AC/300V DC
    18
    218/2
    0.15"PVC
    RedPVC
    Black, Red0 to 165FPLP
    UL Listed
    8435T210000000000000000000000000000000
    18
    418/4
    0.18"PVC
    RedPVC
    Black, Green, Red, Yellow0 to 165FPLP
    UL Listed
    8435T2300000000000000000000
     
    Shielded Solid Wire
    Image of Product. Front orientation. Fire Alarm Cable. Duct-Rated Fire Alarm Cable , Shielded.
     
    300V AC/300V DC
    18
    218/2
    0.16"PVC
    RedPVC
    Black, Red32 to 165Uninsulated Ground WireFPLP
    UL Listed
    8435T2200000000000000000000000000
     