    172 Products

    Jack Pumps

    Image of Product. Front orientation. Jack Pumps. Electric, Style 7.
    Image of Product. Front orientation. Jack Pumps. Electric, Style 8.
    Image of Specification. Top orientation. NEMA 5-20.

    Electric

    Style 7

    Electric

    Style 8

    NEMA

    5-20

    Connect these pumps to a ram to create a hydraulic jack. Use hose to connect; add a pressure gauge to monitor hydraulic oil pressure levels and guard against overload.
    Warning: Never use to support people or loads over people.
    Styles 7 and 8—Styles 7 and 8 pumps operate from up to 10 ft. away using the included wired remote.
    2 Speeds—Pumps with two-speeds are quick to pump until the load is engaged, then pump more slowly for precise positioning.
    Pump
    Mounting
    Electrical
    Style
    Working
    Orientation
    Pump Oil
    Cap., cu. in.
    No. of
    Speeds
    Lg.
    Wd.
    Ht.
    Max. Pressure,
    psi
    Pipe
    Size
    Thread
    Type
    Gender
    Pump Material
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Connection
    No. of
    Blades
    Plug Connection
    NEMA Type
    Includes
    Each
    Electric
    7Vertical11629 5/8"9 5/8"14 1/4"10,0003/8
    NPTF
    FemaleAluminum, SteelNo43/8"Straight Blade3Remote Control with 10-ft. Cord28945T31000000000
    8Vertical590211 1/2"9 1/2"19 5/8"10,0003/8
    NPTF
    FemaleAluminum, SteelNo41/2"5-20
    Remote Control with 10-ft. Cord2920T1700000000
     

    Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Harsh-Environment Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    An aluminum enclosure around the motor provides protection in dusty and dirty environments. Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    12V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional2.2 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K43000000
     
    24V DC—Without Thermal Overload Protection
     
    Hardwire
    0.61 gpm (78 fl oz/min)462080010 to 180Fractional1.4 ampBarbed
    Male3/16"Barbed
    Male3/16"4"1 3/4"2 1/2"8220K4400000
     

    Hydraulic Power Units

    Image of Product. Front orientation. Hydraulic Power Units.
    Create and supply hydraulic pressure. Choose a unit with a tank capacity about three times greater than your requirement to allow for heat dissipation. An inlet filter protects the pump from contamination.
    All units include an additional NPTF threaded inlet port. NPTF (Dryseal) threads are compatible with NPT threads. UN/UNF (SAE Straight) thread connections have straight threads and are also known as O-ring Boss fittings.
    Overall
    Inlet Connection —
    UN/UNF (SAE Straight)
    Inlet
    Connection — NPTF
    Outlet Connection —
    UN/UNF (SAE Straight)
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Power,
    hp
    Cap.,
    gal.
    Lg.
    Wd.
    Ht.
    Thread
    Size
    Dash
    Size
    Pipe
    Size
    Dash
    Size
    Thread
    Size
    Dash Size
    Full Load Current
    @ Voltage
    Each
    240V AC/460V AC, Three Phase
    0.91,6001513"15"20 1/2"7/8"-14
    101/2
    087/8"-14
    101.5 amp @ 460V AC62915K31000000000
    1.32,3002513"15"24 1/2"7/8"-14
    101/2
    087/8"-14
    102.8 amp @ 460V AC62915K3200000000
    2.71,75031017 3/8"19"32 1/2"1 1/16"-12
    123/4
    121 1/16"-12
    124.4 amp @ 460V AC62915K3300000000
    3.62,05051017 3/4"19"29 3/4"1 1/16"-12
    123/4
    121 1/16"-12
    126.8 amp @ 460V AC62915K4400000000
    6.31,8007 1/22021 3/8"22 1/2"37 3/8"1 1/16"-12
    123/4
    121 1/16"-12
    129.5 amp @ 460V AC62915K3600000000
    8.61,700103021 3/8"22 1/2"42 1/4"1 1/16"-12
    123/4
    121 1/16"-12
    1212 amp @ 460V AC62915K4700000000
    10.42,100153023 3/8"22 1/2"44 1/8"1 1/16"-12
    123/4
    121 1/16"-12
    1218.1 amp @ 460V AC62915K48000000000
     

    Slim-Shaft Hydraulic Power Units

    Image of Product. Front orientation. Hydraulic Power Units. Slim-Shaft Hydraulic Power Units.
    Image of Product. Front orientation. Hydraulic Tanks. Slim-Shaft Hydraulic Power Units.

    Replacement Hydraulic Tanks

    Mount these units to an existing machine or where space is limited. They create and supply hydraulic pressure where standard models won’t fit. Choose a unit with a tank capacity about three times greater than your requirement to allow for heat dissipation.
    Hydraulic Power Units
    Replacement
    Hydraulic Tanks
    Overall
    Inlet
    Connection — NPT
    Outlet
    Connection — NPT
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Power,
    hp
    Cap.,
    gal.
    Lg.
    Wd.
    Ht.
    Pipe
    Size
    Dash
    Size
    Pipe Size
    Dash
    Size
    Full Load Current
    @ Voltage
    Each
    Each
    120V AC/240V AC, Single Phase
    12,50022.336 1/8"8 1/8"8 5/8"1/4
    043/8
    0610 amp @ 240V AC3973K410000000003973K4150000000
    1.52,50022.334 7/8"8 1/8"8 5/8"1/4
    043/8
    0610 amp @ 240V AC3973K42000000003973K415000000
     

    Constant-Flow-Rate Gear Pumps for Oil

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps for Oil.
    A high-horsepower motor moves oil with a viscosity similar to SAE 60 motor oil. These gear pumps produce a smooth flow of liquid to lubricate equipment and blend oils. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Cannot Be Sold Outside North America—Products cannot be sold outside North America due to restrictions.
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow
    Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current
    Pipe
    Size
    Connection
    Gender
    Pipe
    Size
    Connection
    Gender
    Lg.
    Wd.
    Ht.
    Cannot Be Sold To
    Each
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    5 gpm577250880-20 to 2401/22 amp/1 amp1/2
    ThreadedFemale1/2
    ThreadedFemale21 5/8"6 7/8"8 1/2"Outside North America41505K41000000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    10 gpm577250880-20 to 24026.2 amp/3.1 amp3/4
    ThreadedFemale3/4
    ThreadedFemale24"6 7/8"8 1/2"Outside North America41505K4300000000
    20 gpm577250880-20 to 24026.2 amp/3.1 amp1
    ThreadedFemale1
    ThreadedFemale24 1/2"6 7/8"8 1/2"Outside North America41505K4500000000
    30 gpm577250880-20 to 24038.2 amp/4.1 amp1
    ThreadedFemale1
    ThreadedFemale25"6 7/8"8 1/2"Outside North America41505K4700000000
    40 gpm577250880-20 to 240513.8 amp/6.9 amp1 1/2
    ThreadedFemale1 1/2
    ThreadedFemale28 1/8"11 7/8"8 1/2"Outside North America41505K4900000000
     

    Compact Constant-Flow-Rate Gear Pumps for Water and Oil

    Image of Product. Front orientation. Gear Pumps. Compact Constant-Flow-Rate Gear Pumps for Water and Oil.
    Designed to fit into small equipment, these pumps have miniature gears and a fractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer
    Intake (NPT)
    Discharge (NPT)
    Overall
    Max. Flow Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power
    Current
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K410000000
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    0.43 gpm (55 fl oz/min)282080010 to 180Fractional1.5 ampBarbed
    Male3/16"Barbed
    Male3/16"4 3/8"3"3 3/4"8220K42000000
     

    Constant-Flow-Rate Gear Pumps for Water

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps for Water.
    These gear pumps produce a smooth flow of liquid for applications such as cooling engines, powering hydraulic equipment, and extracting liquid from holding tanks. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward. Do not use with solids. Pumps can be used in dusty, dirty, and damp environments.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Cannot Be Sold to Canada—Pumps that cannot be sold to Canada are restricted by local energy efficiency requirements.
    Intake
    (NPT)
    Discharge
    (NPT)
    Overall
    Max. Flow
    Rate, gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current
    Pipe
    Size
    Gender
    Pipe
    Size
    Gender
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Cannot Be
    Sold To
    Each
    115V AC/230V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    2.1150100,00032 to 1401/27.4 amp/3.7 amp1/4
    Female1/4
    FemaleTotally Enclosed16 1/16"8 3/16"8"4272K31000000000
    8.5150100,00032 to 140112.8 amp/6.4 amp1/2
    Female1/2
    FemaleTotally Enclosed18 1/8"9 3/16"9"4272K2100000000
     
    230V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    10.2150100,00032 to 1401 1/24.4 amp/2.2 amp1/2
    Female1/2
    FemaleTotally Enclosed Fan-Cooled (TEFC)19 13/16"9 5/16"7 1/4"Canada4272K2200000000
    23150100,00032 to 14038.4 amp/4.2 amp1
    Female1
    FemaleTotally Enclosed Fan-Cooled (TEFC)25 1/8"10 5/16"9 1/16"Canada4272K2300000000
     

    High-Head Circulation Pumps for Water, Coolants, and Oil

    Propel liquid higher and farther than standard circulation pumps. They're commonly used with chillers, heat exchangers, and boiler feed systems. The motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Head Circulation Pumps for Water, Coolants, and Oil.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    @ 100 ft.
    of Head
    @ 150 ft.
    of Head
    @ 200 ft.
    of Head
    @ 250 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    Hardwire—52 cP Maximum Viscosity
    33332165701/37.5 amp/4 amp1 Female NPT1 Female NPT13 5/8"6 1/2"6 7/8"43195K5100000000043195K5120000000
    44444180751/29.5 amp/5.1 amp1 Female NPT1 Female NPT13 5/8"6 1/2"6 7/8"43195K520000000043195K522000000
    66665542801203/410.3 amp/5.2 amp1 Female NPT1 Female NPT14 1/8"6 1/2"6 7/8"43195K530000000043195K532000000
     
    Repair Kits
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Head Circulation Pumps for Water, Coolants, and Oil.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    @ 120 ft.
    of Head
    @ 130 ft.
    of Head
    @ 140 ft.
    of Head
    @ 150 ft.
    of Head
    @ 200 ft.
    of Head
    @ 250 ft.
    of Head
    @ 300 ft.
    of Head
    @ 350 ft.
    of Head
    Max. ft. of
    Head, ft.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    Hardwire—52 cP Maximum Viscosity
     
    165 psi Maximum Pressure
    1099888877653801 1/24.6 amp to 4.8 amp/2.4 amp1 Female NPT1 Female NPT15 1/8"6 1/2"8 5/8"43195K5600000000043195K5620000000
     
    170 psi Maximum Pressure
    131212111111111098740025.2 amp to 5.6 amp/2.6 amp1 Female NPT1 Female NPT15 1/2"6 1/2"8 5/8"43195K570000000043195K572000000
     
    Repair Kits

    Circulation Pumps for Water and Oil

    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Water and Oil.
    These pumps can be used to move water and lubricating oil in boiler feed systems, cooling towers, and heat exchangers. The housing rotates for vertical or horizontal discharge. They have totally enclosed fan-cooled (TEFC) motors for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC/230V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure
    47423425104575201/29 amp/5 amp1 Female NPT3/4 Female NPT13"8 3/4"8 5/8"8249K230000000
    797263513555275201 1/218 amp/9 amp1 1/4 Female NPT1 Female NPT14 1/4"8 3/4"8 5/8"8249K24000000
     
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure
    90857869564015657520216 amp/8 amp to 9 amp1 1/4 Female NPT1 Female NPT15 1/8"8 7/8"8 1/2"8249K93000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure
    48423525104575201/22.7 amp to 2.8 amp/1.4 amp1 Female NPT3/4 Female NPT12 3/8"8 7/8"7 1/4"8249K211000000
    9085786956401565752025.5 amp to 5.8 amp/2.9 amp1 1/4 Female NPT1 Female NPT14 5/8"8 7/8"8 1/2"8249K9600000000
     
    Replacement Seals

    Metering Diaphragm Pumps for Coolants and Oils

    Image of Product. Front orientation. Diaphragm Pumps. Metering Diaphragm Pumps for Coolants and Oils.
    Use these diaphragm pumps for high-pressure output of antifreeze, hydraulic oil, and motor oil. They have an internal relief valve to prevent pressure buildup. The adjustment dial alters flow rate in 1% increments of the maximum flow. Pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. Do not run dry or use with solids.
    Intake
    Discharge
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection and With Internal Relief Valve
     
    Plug In
    4.8 to 487001,50040 to 2001/35.93/8
    NPT
    Male3/8
    NPT
    Male14 3/4"5 1/2"15 1/2"4046K53000000000
    16.8 to 1689001,50040 to 2001/35.93/8
    NPT
    Male3/8
    NPT
    Male14 3/4"5 1/2"15 1/2"4046K5900000000
    43.2 to 4323501,50040 to 2001/35.93/8
    NPT
    Male3/8
    NPT
    Male14 3/4"5 1/2"15 1/2"4046K6300000000
     

    Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style B

    Alter the flow rate for versatile dispensing. These pumps do not include a drum connector.
    Pump Body
    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style B

    Pumps
    Repair Kits
    Connectors
    Temp.
    Intake
    Discharge
    (Pump Body)
    Electrical
    Style
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Connection
    For Tube
    ID
    Connection
    No. of
    Blades
    Each
    Each
    Each
    120V AC—Single Phase—Plug In—With Thermal Overload Protection
    B0 to 3516551,500Not Rated13018.52"1 5/8"39"Barbed
    1"Straight Blade32850K350000000002850K7100000002850K62000000
    B0 to 3516551,500Not Rated13018.52"1 5/8"47"Barbed
    1"Straight Blade32850K36000000002850K710000002850K6200000
    B0 to 3516551,500Not Rated17518.52"1 1/2"39"Barbed
    1"Straight Blade32850K55000000002850K910000002850K94000000
    B0 to 3516551,500Not Rated17518.52"1 1/2"47"Barbed
    1"Straight Blade32850K56000000002850K910000002850K94000000
    B0 to 3516551,500Not Rated17518.52"1 5/8"39"Barbed
    1"Straight Blade32850K41000000002850K720000002850K6200000
     
    Pump Replacement Parts

    Self-Priming Stainless Steel Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Stainless Steel Circulation Pumps for Chemicals.
    Self-priming up to 6 ft., these pumps have a stainless steel housing sealed with PTFE to resist chemicals such as ammonia. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    6854415075402503/49 amp/5 amp1 1/2 Female NPT1 1/2 Female NPT15 3/4"8 3/4"9 1/2"1019N21000000000
    10065455075402501 1/218 amp/9 amp1 1/2 Female NPT1 1/2 Female NPT16 1/2"8 3/4"9 1/2"1019N2300000000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    6854415075402503/43 amp/2 amp1 1/2 Female NPT1 1/2 Female NPT15 1/4"8 3/4"9 1/2"1019N2200000000
    10065455075402501 1/25 amp/3 amp1 1/2 Female NPT1 1/2 Female NPT16 1/4"8 3/4"9 1/2"1019N2400000000
    13282601463754025026 amp/3 amp1 1/2 Female NPT1 1/2 Female NPT17 1/4"8 3/4"9 1/2"1019N2500000000
     

    Electric Drum Pumps for Water, Oil, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps for Water, Oil, and Chemicals, Style B.

    Style B

    Drain and transfer liquid more quickly and easily than hand-operated pumps and siphon pumps.
    Style B
    Image of Product. Front orientation. Drum Pumps. Electric Drum Pumps for Water, Oil, and Chemicals, Style B.
    Pumps
    Repair Kits
    Temp.
    Intake
    Discharge
    Electrical
    For Container
    Size, gal.
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Connection
    No. of
    Blades
    Each
    Each
    120V AC—Single Phase—Plug In
    551771,000Not Rated1801/26.32 NPTDrum Connector1 1/2"39 1/2"1"1 1/4"60"Straight Blade32539K5800000002539K120000000
     
    Pump Replacement Parts

    High-Efficiency Circulation Pumps for Water, Coolants, and Oil

    Use less electricity to achieve the same flow rates as other circulation pumps. These pumps have a totally enclosed motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    120V AC/208V AC to 240V AC, Single Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Pumps
    Impellers
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 20 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    Hardwire
    252426100171/36.2 amp/3.1 amp to 3.4 amp1 Female NPT3/4 Female NPT14"8 1/2"7"9923K410000000004320K260000000
    403734100171/27.4 amp/3.6 amp to 3.7 amp1 Female NPT3/4 Female NPT14"7 5/8"7 15/16"9923K420000004320K27000000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Cannot Be Sold To—Pumps that cannot be sold to the listed regions do not meet energy efficiency requirements.
    Pumps
    Impellers
    Flow
    Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be
    Sold To
    Each
    Each
    Hardwire
    3002101406210017511.8 amp/5.9 amp2 1/2 Female NPT2 Female NPT21 1/2"12"11"Canada9923K480000000004320K530000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Cannot Be Sold To—Pumps that cannot be sold to the listed regions do not meet energy efficiency requirements.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be Sold To
    Each
    Each
    Hardwire
    453440100173/43 amp to 3.3 amp/1.5 amp1 Female NPT3/4 Female NPT14"8 1/2"7"9923K4300000004320K280000000
    1307560531001713 amp to 3.2 amp/1.5 amp1 1/2 Female NPT1 1/4 Female NPT15"9"8"California, Canada9923K45000000004320K29000000
    15512585581001737.2 amp to 7.9 amp/3.6 amp2 Female NPT1 1/2 Female NPT17"10 1/2"8"Canada9923K47000000004320K49000000
    16012585561001725 amp to 5.3 amp/2.5 amp2 Female NPT1 1/2 Female NPT17"10 1/2"8"Canada9923K46000000004320K31000000
    26021076100177 1/216.8 amp to 18.5 amp/8.4 amp2 1/2 Female NPT2 Female NPT23"12"11"Canada9923K49000000004320K54000000
     

    Stainless Steel Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Stainless Steel Circulation Pumps for Chemicals.
    A 316 stainless steel housing sealed with fluoroelastomer resists mild chemicals and acids, such as coolant, oil, and phosphoric acid. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    322210441001/8"501/35.6 amp/2.8 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K8100000004320K110000000
    32323220621003/32"503/410.6 amp/5.3 amp1 1/4 Female NPT3/4 Female NPT16"9"7 3/4"4320K84000000004320K14000000
    363022541001/8"501/27.6 amp/3.8 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K820000004320K12000000
    38332718591001/8"503/410.6 amp/5.3 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K830000004320K13000000
    90826335601003/32"50112.6 amp/6.3 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K95000000004320K14000000
     
    240V AC/460V AC, Three Phase—With Thermal Overload Protection
     
    Hardwire
    754715341003/16"5012.9 amp/1.4 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K96000000004320K11000000
    95805520491003/16"501 1/23.9 amp/2 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K88000000004320K13000000
    110100805828701003/32"501 1/23.9 amp/2 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K87000000004320K15000000
    11555521003/16"5025.3 amp/2.7 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K91000000004320K16000000
    1309060821003/32"5025.3 amp/2.7 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K92000000004320K17000000
    1309555791003/16"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K94000000004320K19000000
    1408555881003/32"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K93000000004320K18000000
     
    Repair Kits

    High-Flow Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. High-Flow Peristaltic Pumps for Chemicals.
    For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,592 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
    Intake
    Discharge
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    For Tube
    ID
    Connection
    For Tube
    ID
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    120V AC, Single Phase
     
    Plug In
    2,592201,00035 to 1601/43.11/2"Barbed
    1/2"Barbed
    10"5 1/2"10"10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61)4306K640000000
     
    Replacements for Peristaltic Pumps

    Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    These pumps quickly empty drum contents by moving 48 gallons of liquid per minute. They are often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions. Their electric motors are explosion proof and UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Division 2, Groups F and G environments where flammable gases and combustible dust may be present.
    Pumps
    Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    (Pump Body)
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Connection
    For Tube
    ID
    Gender
    Certification
    Each
    Each
    120V AC—Single Phase—Hardwire—With Thermal Overload Protection
    48.55514300-402101/25.341 mm1 5/8"39"Pump BodyBarbed
    1"MaleC-UL Listed
    UL Listed
    42675K4700000000042675K670000000
     
    Pump Replacement Parts

    Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
    Aluminum Housing—Pumps with an aluminum housing are often used with lubricating oil and coolants. Their motors are rated IP44.
    316 Stainless Steel Housing—Pumps with a 316 stainless steel housing are often used with fuel, acetone, methyl ethyl ketone (MEK), xylene, and mineral spirits. Their motors are rated IP55 and are CSA certified for use in Class I, Divisions 1 and 2, Group D hazardous environments with flammable gases and vapors.
    47" Long Intake Tube—Pumps with a 47" intake tube can be used with large totes and tanks.
    Temp.
    Intake
    Discharge
    Electrical
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Hazardous Location Rating
    Enclosure
    Rating
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—NEMA 5-15 Plug In
     
    Aluminum Housing
    2215551,500Not Rated17517.52 NPT1 1/2"39"1"1 1/4"72"IP44
    Straight Blade37133T25000000000
    2215551,500Not Rated17517.52 NPT1 1/2"47"1"1 1/4"72"IP44
    Straight Blade37133T2600000000
     
    120V AC—Single Phase—Hardwire
     
    316 Stainless Steel Housing
    1815551,000Not Rated1751 1/39.12 NPT1 1/2"39"1"1 1/4"72"NEC Class I Divisions 1, 2 Group D
    IP55
    7133T2700000000
     

    Harsh-Environment Circulation Pumps for Water and Oil

    Image of Product. Front orientation. Centrifugal Pumps. Harsh Environment Circulation Pumps for Water and Oil.
    The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Use these pumps to move water and lubricating oil in boiler feed systems, cooling towers, and heat exchangers. The housing rotates for vertical or horizontal discharge. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created, which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    696152422445275402003/410 amp/5 amp to 5.2 amp1 1/2 Female NPT1 1/2 Female NPT15 7/8"8 7/8"9 1/2"8249K87000000000
    1009179664875275402001 1/216.6 amp/8.3 amp to 9 amp1 1/2 Female NPT1 1/2 Female NPT16 1/2"8 7/8"9 1/2"8249K8900000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    696152422445275402003/42.7 amp to 2.8 amp/1.35 amp1 1/2 Female NPT1 1/2 Female NPT15 3/8"8 7/8"9 1/2"8249K8800000000
    1009179664875275402001 1/24.2 amp to 4.3 amp/2.2 amp1 1/2 Female NPT1 1/2 Female NPT16 3/8"8 7/8"9 1/2"8249K9100000000
    1301231139982611663754020025.5 amp to 5.8 amp/2.9 amp1 1/2 Female NPT1 1/2 Female NPT17 3/8"8 7/8"9 1/2"8249K9200000000
     
    Replacement Seals

    High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    Designed to move 40 gallons of liquid per minute, these pumps quickly empty drum contents. They're often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions.
    Temp.,
    ° F
    Intake
    Discharge
    Electrical
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—Plug In
    403035500351601/25.72 NPTDrum Connector2"27"Tube End1"1 5/16"60"PVC
    Straight Blade36800K12000000000
    405535500-202201/25.72 NPTDrum Connector2"40"Tube End1"1 5/16"60"PVC
    Straight Blade36800K3400000000
    405535500-202201/25.72 NPTDrum Connector2"48"Tube End1"1 5/16"60"PVC
    Straight Blade36800K3800000000
    405535500351601/25.72 NPTDrum Connector2"40"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1400000000
    405535500351601/25.72 NPTDrum Connector2"48"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1800000000
     
    Pump Replacement Parts

    High-Head High-Efficiency Circulation Pumps for Water, Coolants, and Oil

    Image of Product. Front orientation. Centrifugal Pumps. High-Head High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Propel liquid higher and farther than standard high-efficiency circulation pumps. These pumps use less electricity to achieve the same flow rates as other circulation pumps. They have a totally enclosed fan cooled (TEFC) motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. They cannot be sold to the regions listed due to local energy efficiency requirements.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    @ 100 ft.
    of Head
    @ 110 ft.
    of Head
    @ 120 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be Sold To
    Each
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—17 cP Maximum Viscosity
    402975150025013 amp to 3.2 amp/1.5 amp1 1/4 Female NPT1 Female NPT16"7 7/8"9"California, Canada8256K41000000000
    50473930110150025026 amp/3 amp1 1/4 Female NPT1 Female NPT16"7 7/8"9"California, Canada8256K4300000000
    5037269215002501 1/24.6 amp to 4.9 amp/2.3 amp1 1/4 Female NPT1 Female NPT16"7 7/8"9"California, Canada8256K4200000000
    80705847137150025037.4 amp to 7.9 amp/3.7 amp1 1/2 Female NPT1 1/4 Female NPT18"10"9 7/8"Canada8256K4400000000
    200165145124971351500250511.6 amp to 12.6 amp/5.8 amp2 Female NPT1 1/2 Female NPT22"9 1/4"10"Canada8256K4500000000
     

    Fixed-Flow-Rate Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Fixed-Flow-Rate Peristaltic Pumps for Chemicals.
    Also known as tubing pumps, these maintain a fixed flow rate. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount them up to 25 feet above your liquid source. All can run dry. Do not use with solids.
    Viton® Fluoroelastomer Wetted Parts—Pumps with Viton® Fluoroelastomer tubing withstand oil such as gasoline and hydraulic oil.
    Pumps
    Replacement
    Pump Heads
    Overall
    Flow Rate, gal./day
    (For Tube ID)
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp.,
    ° F
    Power
    Current,
    amp
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Each
    115V AC, Single Phase—Plug In
     
    PVDF and Viton® Fluoroelastomer Wetted Parts
    0.02 (1/32")
    0.07 (1/16")
    0.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K211000000043045K116000000
    0.11 (1/32")
    0.34 (1/16")
    1.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21200000043045K11600000
    0.87 (1/16")
    3.53 (1/8")
    6.84 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21600000043045K12200000
    1.75 (1/16")
    7.07 (1/8")
    13.68 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K21700000043045K12200000
    22.8 (3/16")
    38 (1/4")
    1550032 to 122Fractional0.525"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K22200000043045K12700000
    45.6 (3/16")
    76 (1/4")
    1520032 to 122Fractional0.655"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K22300000043045K12700000
    228 (3/16")
    380 (1/4")
    155032 to 122Fractional1.745"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)43045K22400000043045K12700000
     
    Replacement Pump Intake Tubes
    back to top