    About Electric Motors
    industrial info icon

    Select a new motor using the information on the nameplate, including voltage, size, and enclosure type.

    Sanitary and Washdown Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Face-Mount AC Motors, Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure.
    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Face-Mount AC Motors, Totally Enclosed Nonventilated (TENV) Motor Enclosure.

    Totally Enclosed Fan-Cooled

    (TEFC) Motor Enclosure

    Totally Enclosed Nonventilated

    (TENV) Motor Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Sanitary and Washdown Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Sanitary and Washdown Face-Mount AC Motors.
    Bolt these motors directly to conveyors and other machines to power equipment on food and sanitary lines. They help you meet Good Manufacturing Practices (GMP) since they have many features that make them safe for sanitary and washdown environments. Smooth contours and a laser-marked nameplate limit the space where bacteria could grow. They don’t have feet, so they’re easy to rinse down thoroughly. A stainless steel enclosure, epoxy resin lined interior, and IP69 rating mean they withstand hot spraying water, harsh cleaners, and sanitizers common to food plants. A two-barrier seal keeps water from getting in through the shaft. If water does seep in, drain plugs let it out.
    These motors are also called C-face motors. They’re rated for continuous duty, so they’ll run equipment that never turns off. Inverter rated, they also work with variable frequency drive (VFD) to run at different speeds. You can wire for clockwise or counterclockwise rotation; instructions are included. Their conduit box also rotates to connect conduit from any side without needing to reroute power.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—TEFC (totally enclosed fan-cooled) motors have a fan that cools the housing.
    Totally Enclosed Nonventilated (TENV) Motor Enclosure—TENV (totally enclosed nonventilated) motors don’t need a fan or ventilation. They have even fewer places for water and contaminants to get in than TEFC motors.
    Overall
    Shaft
    Insulation
    Torque @ 460V
    AC, in·lbf
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Starting
    Torque
    Continuous Operating
    Torque
    Enclosure
    Rating
    Each
    208V AC/230V AC/460V AC, Three Phase
     
    NEMA 56C—Totally Enclosed Fan-Cooled (TEFC) with Rotatable Conduit Box
    1/21,8001.9 amp/1.8 amp/0.9 ampNo13"9 7/8"6 1/2"5/8"1 7/8"3 1/4"KeyedH3566117.8IP69
    3540N12000000000
     
    NEMA 56C—Totally Enclosed Nonventilated (TENV) with Rotatable Conduit Box
    3/43,6002.1 amp/2.0 amp/1.0 ampYes11 3/4"9 7/8"6 1/2"5/8"1 7/8"3 1/4"KeyedH35656.813.5IP69
    3540N1300000000
     
    230V AC/460V AC, Three Phase
     
    NEMA 56C—Totally Enclosed Fan-Cooled (TEFC) with Rotatable Conduit Box
    3/41,8002.6 amp/1.3 ampYes14"9 7/8"6 1/2"5/8"1 7/8"3 1/4"KeyedH35696.126.8IP69
    3540N1400000000
    21,8005.6 amp/2.8 ampYes14"9 7/8"6 1/2"5/8"2"3 1/4"KeyedH35620872.1IP69
    3540N2500000000
     
    NEMA 56C—Totally Enclosed Nonventilated (TENV) with Rotatable Conduit Box
    13,6002.8 amp/1.4 ampNo11 3/4"9 7/8"6 1/2"5/8"1 7/8"3 1/4"KeyedH35696.118.2IP69
    3540N1500000000
    1 1/23,6003.6 amp/1.8 ampYes13 3/4"9 7/8"6 1/2"5/8"2"3 1/4"KeyedH356122.427.7IP69
    3540N1800000000
    23,6004.8 amp/2.4 ampNo15"9 7/8"6 1/2"5/8"2"3 1/4"KeyedH356165.635.8IP69
    3540N2300000000
     
    NEMA 143TC—Totally Enclosed Fan-Cooled (TEFC) with Rotatable Conduit Box
    21,8005.6 amp/2.8 ampYes14"9 7/8"6 1/2"7/8"2 1/8"3 1/4"KeyedH35620872.1IP69
    3540N2600000000
     
    NEMA 145TC—Totally Enclosed Fan-Cooled (TEFC) with Rotatable Conduit Box
    33,6007.4 amp/3.7 ampYes16 1/4"9 7/8"6 1/2"7/8"2 1/8"3 1/4"KeyedH35620454IP69
    3540N2700000000
     

    Sanitary and Washdown Base/Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Base/Face-Mount AC Motors, Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure.
    Image of Product. Front orientation. Electric Motors. Sanitary and Washdown Base/Face-Mount AC Motors, Totally Enclosed Nonventilated (TENV) Motor Enclosure.

    Totally Enclosed Fan-Cooled

    (TEFC) Motor Enclosure

    Totally Enclosed Nonventilated

    (TENV) Motor Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Sanitary and Washdown Base/Face-Mount AC Motors.
    Image of Specification. Front orientation. Contains Annotated. 9 3/4" Overall Width. Sanitary and Washdown Base/Face-Mount AC Motors.
    For versatility in food and sanitary lines, these motors mount by their feet or bolt directly to equipment to power pumps and other machines. Many features make them safe for sanitary and washdown environments: Smooth contours and a laser-marked nameplate limit where bacteria could grow. A stainless steel enclosure, epoxy resin lined interior, and IP69 rating mean they stand up to hot spraying water, chemicals, and harsh cleaners often used in food plants. A two-barrier seal on the shaft stops water from getting in. If water does seep in, drain plugs let it out.
    Rated for continuous duty, these motors run equipment that never turns off. They’re also inverter rated, so they work with variable frequency drive (VFD) to run at different speeds. You can wire for clockwise or counterclockwise rotation; instructions are included. The conduit box also rotates, so there’s no need to reroute power when connecting conduit.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—TEFC (totally enclosed fan-cooled) motors have a fan that cools the housing.
    Totally Enclosed Nonventilated (TENV) Motor Enclosure—TENV (totally enclosed nonventilated) motors don’t need a fan or ventilation. They have even fewer places for water and contaminants to get in than TEFC motors.
    Overall
    Shaft
    Insulation
    Torque @ 460V
    AC, in·lbf
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Starting
    Torque
    Continuous Operating
    Torque
    Enclosure
    Rating
    Each
    208V AC/230V AC/460V AC, Three Phase
     
    NEMA 56C—Totally Enclosed Nonventilated (TENV)
    1/21,8001.9 amp/1.8 amp/0.9 ampYes11 3/4"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH35661.117.9IP69
    3548N12000000000
     
    230V AC/460V AC, Three Phase
     
    NEMA 56C—Totally Enclosed Fan-Cooled (TEFC)
    23,6005.0 amp/2.5 ampYes14 7/8"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH356165.635.9IP69
    3548N2300000000
     
    NEMA 56C—Totally Enclosed Nonventilated (TENV)
    3/41,8002.2 amp/1.1 ampYes12 3/4"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH35697.226.9IP69
    3548N1400000000
    11,8003.0 amp/1.5 ampYes12 3/4"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH35611436IP69
    3548N1600000000
    1 1/23,6003.6 amp/1.8 ampYes13 5/8"9 3/4"6 3/4"5/8"2"3 1/2"KeyedH356122.427.7IP69
    3548N1800000000
     
    NEMA 145TC—Totally Enclosed Fan-Cooled (TEFC)
    33,6007.4 amp/3.7 ampYes16 1/4"9 3/4"6 3/4"7/8"2 1/8"3 1/2"KeyedH35620454IP69
    3548N2700000000
     

    Washdown AC Gearmotors

    IP rated, these gearmotors stand up to high-pressure washdowns. They combine a motor with a speed reducer to lower speed while increasing torque. Their parallel shaft transmits motion inline with the motor.
    Since they’re inverter rated, you can adjust the speed with a motor speed control (not included). Wire these motors for clockwise or counterclockwise rotation; instructions are included.
    Round Face
    Image of Product. Front orientation. Electric Gearmotors. Washdown AC Gearmotors, Round Face.
    Image of Attribute. Front orientation. Contains Annotated. Washdown AC Gearmotors, Round Face.
    Image of Attribute. Side1 orientation. Contains Annotated. Washdown AC Gearmotors, Round Face.
    Face Mount—Face-mount motors bolt directly to your equipment. They require a power cord (sold separately).
    Totally Enclosed Nonventilated (TENV) Motor Enclosure—TENV (totally enclosed non-ventilated) enclosures are similar to TEFC motor enclosures, except they do not have a fan. They rely on air circulation from the motion of the motor for cooling.
    IP69K Enclosure Rating—Motors rated IP69K protect against dust, debris, and high-temperature washdowns.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Speed @ Continuous
    Operating Torque
    Full Load
    Current, amp
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    230V AC—Face Mount
    1/87 rpm @ 500 in·lbf0.5Totally Enclosed Nonventilated (TENV)10 3/4"5 1/4"5 1/4"3/4"1 5/8"3.45"F311IP69K
    4862N23000000000
    1/812 rpm @ 500 in·lbf0.5Totally Enclosed Nonventilated (TENV)10 3/4"5 1/4"5 1/4"3/4"1 5/8"3.45"F311IP69K
    4862N2400000000
    1/824 rpm @ 256 in·lbf0.5Totally Enclosed Nonventilated (TENV)10 3/4"5 1/4"5 1/4"3/4"1 5/8"3.45"F311IP69K
    4862N2500000000
    1/847 rpm @ 128 in·lbf0.5Totally Enclosed Nonventilated (TENV)10 3/4"5 1/4"5 1/4"3/4"1 5/8"3.45"F311IP69K
    4862N2600000000
    1/891 rpm @ 70 in·lbf0.5Totally Enclosed Nonventilated (TENV)10 3/4"5 1/4"5 1/4"3/4"1 5/8"3.45"F311IP69K
    4862N2700000000
    1/8178 rpm @ 34 in·lbf0.5Totally Enclosed Nonventilated (TENV)10 3/4"5 1/4"5 1/4"3/4"1 5/8"3.45"F311IP69K
    4862N2800000000
    1/8347 rpm @ 16 in·lbf0.5Totally Enclosed Nonventilated (TENV)10 3/4"5 1/4"5 1/4"3/4"1 5/8"3.45"F311IP69K
    4862N2900000000
     
    Cords

    Washdown Enclosed Motor Switches

    Image of Product. Switch with Stainless Steel Housing and Lockout. Front orientation. Motor Switches. Washdown Enclosed Motor Switches, 304 Stainless Steel Housing with Lockout.
    Image of Product. Switch with Polybutylene Housing and Lockout. Front orientation. Motor Switches. Washdown Enclosed Motor Switches, Polybutylene Housing with Lockout.
    Image of Product. Switch with Polybutylene Housing, Lockout, and Power Indicator. Front orientation. Motor Switches. Washdown Enclosed Motor Switches, Polybutylene Housing with Lockout, Power Indicator.

    Switch with

    Stainless Steel

    Housing and

    Lockout

    Switch with

    Polybutylene

    Housing and

    Lockout

    Switch with

    Polybutylene

    Housing,

    Lockout, and

    Power Indicator

    Install these switches in areas with oil, coolant, corrosive chemicals, and regular washdowns. They're rated IP69K and NEMA 4X and 12 or 12K. Since they’re already protected inside a housing, you can mount them to a wall if there’s no space left in your electrical panel. You need to grip and twist the lever to actuate, so they won’t accidentally turn on or off if something bumps into them. To lock them in the off position, attach a padlock (not included) to the lever. Use these switches to turn motors on and off, or with other circuits such as lighting and electric heat circuits. They do not provide overload protection.
    Polybutylene Housing—Switches with a Polybutylene housing can be turned into a handheld control for moving around your workstation by attaching a cord and cord grip. The housing won’t swell in moist environments.
    Power Indicator—Switches with a power indicator use LED lights to show the status of power flowing into the switch and power flowing from the switch to your motor. This can help you check for issues, such as a welded contact or phase loss, without having to open the housing.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Ht.
    Wd.
    Wire
    Connection
    Enclosure Rating
    Certification
    Specs.
    Met
    Flammability
    Rating
    Each
    Maintained
     
    304 Stainless Steel Housing with Lockout
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    306007.1"4.9"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K1030000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    6060010.3"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K104000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    10060010.3"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K10500000000
     
    Polybutylene Housing with Lockout
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    306008.17"5.29"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K71000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    6060011"7.28"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K201000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    10060011"7.28"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K202000000
     
    Polybutylene Housing with Lockout, Power Indicator
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    306008.2"5.3"Screw TerminalNEMA 4X, IP69K, NEMA 12
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K106000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    6060010.9"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K107000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    10060010.9"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K108000000
     
    back to top