McMaster-Carr logo
    Filter by
    System of Measurement
    Shaft Diameter
    Attribute Image
    Environment
    Overall Width
    Attribute Image
    Maximum Rotation Speed
    Motor Frame Size
    Frequency
    Electrical Phase
    Keyway Depth
    Attribute Image
    Shaft Length
    Attribute Image
    Mounting Location
    Overall Length
    Attribute Image
    Inverter Rated
    Direction of Operation
    Keyway Length
    DFARS Specialty Metals
    Shaft Type
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    5 Products

    Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Face-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Face-Mount AC Motors.
    Bolt these motors directly to gearboxes, pumps, and other machinery. They’re more compact than base-mount motors and the direct, rigid connection to your equipment helps keep them aligned. Rated for continuous duty, they are often used with equipment that requires constant power, such as fans and conveyors.
    Motors with a NEMA frame size have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Motors with an IEC frame size meet international standards for electrical products. Their compact body fits in tight spaces.
    Inverter Rated—These motors are inverter-rated, so you can use them with a variable frequency drive (AC motor speed control).
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—A totally enclosed fan-cooled (TEFC) enclosure means you can use them in wet and dirty environments since they don’t have vents. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Cannot Be Sold To—Motors that cannot be sold to the regions listed are restricted due to energy efficiency regulations.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Motor Mounting
    Code
    Dia.,
    mm
    Lg.,
    mm
    Ctr. to
    Base, mm
    Type
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Cannot Be
    Sold To
    Each
    230V AC/460V AC, Three Phase
     
    IEC 100L
    43,5009.8 amp/4.9 ampYesTotally Enclosed Fan-Cooled (TEFC)15 5/8"8 7/8"11 5/8"IM B142860100KeyedF311IP55
    California6135K128000000000
    43,5009.8 amp/4.9 ampYesTotally Enclosed Fan-Cooled (TEFC)15 5/8"9 3/4"11 5/8"IM B52860100KeyedF311IP55
    California6135K13500000000
     

    Base-Mount AC Motors

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.
    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.

    Motor with Totally

    Enclosed Enclosure

    Motor with Open Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Base-Mount AC Motors.
    To get equipment moving, bolt the base of these motors to any flat surface and connect the shaft to your load. They’re rated for continuous duty, so they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
    Motors with a NEMA frame size have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Motors with an IEC frame size meet international standards for electrical products. Their compact body fits in tight spaces.
    Inverter Rated—When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures don’t have vents, so they can be used in wet and dirty environments. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Cannot Be Sold To—Motors that cannot be sold to the regions listed are restricted due to energy efficiency regulations.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Cannot Be
    Sold To
    Each
    230V AC/460V AC, Three Phase
     
    IEC 100L
    44,0009.8 amp/4.9 ampYesTotally Enclosed Fan-Cooled (TEFC)15 3/4"9"11 1/8"28 mm60 mm100 mmKeyedWeldedF311IP55
    California4707N110000000
    44,00010.4 amp/5.2 ampYesTotally Enclosed Fan-Cooled (TEFC)15 3/4"9"11 1/8"28 mm60 mm100 mmKeyedWeldedF311IP55
    California4707N15000000
     
    IEC 112M
    41,76010.6 amp/5.3 ampYesTotally Enclosed Fan-Cooled (TEFC)19"10"12"1.11"2 3/8"4 1/2"KeyedWeldedF311IP55
    59845K8500000000
     
    back to top