    47 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Power Cable

    Image of Product. Front orientation. Power Cable.
    Built for rough handling and frequent positioning, this cable delivers power you can count on. Use it for everything from extension cords to cords for hydraulic presses. Made to NEC Article 400 requirements, you can trust it to power whatever you need. Plus, the flexible jacket takes the struggle out of routing it through tight spaces and around machinery.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-249
    250-Up
    600V AC
     
    SOOW Cable
    2/4
    80 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K34000000000000
     

    Heavy Duty Harsh-Environment Power Cable

    Image of Product. Front orientation. Power Cable. Heavy Duty Harsh-Environment Power Cable.
    Delivering up to 2,000 volts in the harshest conditions, this Type W cable is often used in mining equipment and drilling rigs. It resists abrasion if you drag it across rocky terrain and won’t get crushed even when heavy equipment drives over it. The EPDM jacket stands up to chemicals, oil, and moisture. MSHA accepted, it meets mining safety standards, so you can rely on it where other power cables fail.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    2,000V AC/2,000V DC
     
    Type W Cable
    2/3
    174 amp @ 86° FEPDM
    Black-40 to 190CSA Certified, MSHA Accepted, UL Listed
    2962N700000000000000000000000
     

    Vehicle Cable

    Image of Product. Front orientation. Vehicle Cable.
    Also known as GPT cable, this cable is often used in low-voltage applications such as battery and vehicle wiring and radios. It has one red wire and one black wire to easily identify polarity. The wires can be pulled apart for installation.
    Outer
    Jacket
    Per Ft.
    AWG
    No. of
    Wires
    Cable
    AWG
    Wd.
    Thk.
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Choose a Length, ft.
    1-249
    250-Up
    Stranded Wire
     
    12V DC
    2
    22/2
    0.97"0.45"PVC
    Black, Red-40 to 175GPT
    10, 25, 50, 1009697T760000000000
     

    Building Wire

    Install this copper wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire. The outer jacket is designed to be installed without applying pulling lubricant.
    Stranded Wire with Nylon Outer Jacket and PVC Inner Insulation
    Image of Product. TFFN, THHN/THWN, and THHN/THWN-2 Stranded. Front orientation. Building Wire. Building Wire, Nylon Outer Jacket, Stranded Wire.

    TFFN, THHN/THWN, and THHN/THWN-2

    Stranded

    Stranded wire is flexible, so it’s pliable enough to be pulled around corners.
    Wire with a nylon outer jacket resists oil and water.
    THHN Cable—THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement.
    THWN-2 Cable—THWN and THWN-2 wire can be used in both wet and dry environments.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Shorter Lengths
    Longer Lengths
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    Flammability
    Rating
    Choose an Outer Jacket Color
    Choose a Length, ft.
    Per
    Ft.
    Lg.,
    ft.
    Each
    600V AC/600V DC
    2
    19/15
    130 amp @ 86° F0.38"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Black, Blue, Brown, Green, Orange, Red, White, Yellow10, 25, 50, 100, 2507715T21000005007715T61000000000
     

    Grounding Wire

    Ground your electrical system.
    Flexible Grounding Wire
    Image of Product. Front orientation. Grounding Wire. Noninsulated Solid.
    Image of Product. Front orientation. Grounding Wire. Noninsulated Stranded.

    Noninsulated Solid

    Noninsulated

    Stranded

    AWG
    OD
    Material
    Specs. Met
    Mil. Spec.
    5 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Noninsulated Solid
    2
    0.26"CopperASTM B3Fed. Spec. A-A-595517512K5600000000000000000000000000
     
    Noninsulated Stranded
    2
    0.29"CopperASTM B3, ASTM B8Fed. Spec. A-A-595517512K760000000000000000000000
     

    No-Conduit-Required Control Cable

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Control Cable, Double Shielded.

    Double Shielded

    Made to TC-ER (Tray Cable, Exposed Run) standards, this crush- and impact-resistant cable eliminates the cost and hassle of installing conduit. It’s ideal for exposed runs, such as from a cable tray down to a control panel or motor control box. Support it every six feet to prevent sagging. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Double Shielded—With two layers of shielding, this cable offers better protection against electromagnetic interference (EMI) than single-shielded cable. It’s often used near transformers, generators, and heavy-duty motors that may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    2/4
    130 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    5, 10, 20, 30, 506452T85000000000000
     
    Double Shielded
    2/4
    130 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    5, 10, 20, 30, 506452T950000000000
     

    Welding Cable

    Image of Product. Front orientation. Welding Cable.
    Image of Specification. Front orientation. Contains Border. Welding Cable. Bend and Stay, Stranded Wire Class K.

    Image of Specification. Front orientation. Contains Border. Welding Cable. Flexible, Stranded Wire Class M.

    This cable withstands abrasion, oil, and the rough conditions found in welding applications.
    Stranded Wire Class K—Class K cable is for general purpose welding applications. It bends and stays in the position that you bend it.
    Stranded Wire Class M—Class M cable is more flexible and durable than Class K cable.
    AWG
    Stranded
    Wire Class
    Wire Strand
    Count
    Current @
    Temp.
    Outer Jacket
    Material
    Temp.,
    ° F
    Flammability
    Rating
    Choose an Outer
    Jacket Color
    Choose a Length, ft.
    Per
    Ft.
    600V AC
     
    Bend and Stay
    2
    K624/30EPDM
    -55 to 220UL 2556 VW-1
    Black, Red10, 20, 25, 30, 50, 100, 2507940A9300000
     
    600V AC/600V DC
     
    Flexible
    2
    M1,482/34EPDM
    -55 to 220UL 2556 VW-1
    Orange10, 20, 25, 30, 50, 100, 2507940A770000
     
    Ultra Flexible
    2
    651/30
    190 amp @ 86° FEPDM
    -40 to 190Black, Red10, 25, 50, 1006948K930000
     

    Outdoor Lead Wire

    The EPDM insulation on this wire won’t become brittle or crack from sunlight, humidity, rain, temperature changes, abrasion from dirt and debris, and other rough outdoor conditions. It meets Mine Safety and Health Administration (MSHA) standards for material quality.
    600V AC/600V DC
    Image of Product. Side1 orientation. Lead Wire. Outdoor Lead Wire, 600V AC, 600V DC.
    SC Cable—SC wire is a good choice for temporary setups powering outdoor lights, equipment, generators, and power distribution boxes, since its thick insulation makes it easy to move and reuse. Commonly found at outdoor events, it’s also known as stage cable.
    UL 2556 FT5—All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT5 wire is suspended horizontally during testing.
    Per Ft.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Stranded Wire
    2
    676/30190 amp @ 86° F0.58"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T150000000000
     
    2,000V AC
    Image of Product. Side1 orientation. Lead Wire. Outdoor Lead Wire, 2,000V AC.
    DLO Cable—DLO wire carries higher voltages than SC wire, making it the better choice for heavy duty applications. Use it to run power to motors, cranes, and other equipment in shipyards, mines, and oil- and gas-drilling rigs. Also known as diesel locomotive cable, this wire was originally designed to wire trains. An outer layer of chlorinated polyethylene plastic (CPE) gives it increased resistance to chemicals, heat, and flames. It’s also rated RHW-2, so it can be used underground and in wet locations.
    UL 2556 FT4—All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT4 wire is mounted to a vertical tray during testing.
    AWG
    Current @
    Temp.
    OD
    Max. Temp.,
    ° F
    Outer Jacket
    Material
    Inner Insulation
    Material
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Stranded Wire
    2
    130 amp @ 86° F0.5"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T29000000000000000000000000000
     

    Battery Wire

    Connect batteries in vehicles and generators.
    Stranded Wire with PVC Outer Jacket
    Image of Product. Front orientation. Battery Wire. Battery Wire.
    Wire with a PVC outer jacket resists fuel and oil.
    SAE J1127—SAE wire meets standards for low-voltage wiring in vehicle electrical systems.
    Wire Strand Count—Wire strand count is the number of strands followed by the size of the individual strand.
    Per Ft.
    Wire
    Gauge
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Flexibility
    Temp. Range,
    ° F
    Cable
    Designation
    Specs.
    Met
    Choose an Outer
    Jacket Color
    Choose a Length, ft.
    1-99
    100-Up
    60V DC
    2 AWG
    64/20
    147 amp @ 86° F0.45"Flexible-40 to 190SGTSAE J1127Black, Red10, 25, 50, 1006948K730000000000
     
    Stranded Wire with Cross-Linked Polyolefin Outer Jacket
    Image of Product. Front orientation. Battery Wire. Battery Wire.
    Wire with a cross-linked polyolefin outer jacket is ultra-flexible and withstands high heat, making it suitable for applications such as vehicle engine wiring.
    SAE J1127—SAE wire meets standards for low-voltage wiring in vehicle electrical systems.
    Wire Strand Count—Wire strand count is the number of strands followed by the size of the individual strand.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Cable
    Designation
    Specs.
    Met
    Choose an Outer
    Jacket Color
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    60V DC
    2
    133/24Not Rated0.43"-40 to 255SGXSAE J1127Black, Red6070N130000000000000000000000000000
     

    Harsh-Environment Power Cable

    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable.

    Type P Cable

    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable with Bronze Armor.

    Type P Cable with Bronze Armor

    Transmit power in dirty, corrosive environments such as offshore rigs and ships. This cable is strong enough to resist crushing forces from heavy equipment. Its CPE jacket and tin-plated copper conductors maintain power in areas exposed to chemicals, oil, and salt water. It meets UL 1309 for high-performance marine cables, yet works just as well on land.
    Bronze Armor—A layer of bronze armor between the two outer jackets boosts resistance to abrasion, impact, and crushing.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Specs.
    Met
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Type P Cable
    2/4
    92 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K28000000000000
     
    Type P Cable with Bronze Armor
    2/4
    92 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K580000000000
     

    Continuous-Flex Power Cable

    Image of Product. Side1 orientation. Power Cable. Continuous-Flex Power Cable, Unshielded.
    Image of Product. Side1 orientation. Power Cable. Continuous-Flex Power Cable, Shielded.

    Unshielded

    Shielded

    Power motors on moving gantries and cranes with this cable that flexes millions of times without breaking. It’s made for constant motion, with finely stranded conductors twisted like a rope to resist wear from bending.
    Shielded—Shielding stops these cables from acting as antennas that emit electromagnetic interference, which could disrupt nearby equipment such as control or data cables.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    1,000V AC
     
    Unshielded
    2/4
    152 amp @ 86° F8.55"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K23000000000000
     
    Shielded
    2/4
    152 amp @ 86° F9.6"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K430000000000
     

    High-Temperature Lead Wire

    Image of Product. Front orientation. Lead Wire. High-Temperature Lead Wire.
    Even at 480° F—hotter than some industrial ovens—this wire’s insulation won’t melt.
    Stranded Wire with Fiberglass Fabric Outer Jacket and Mica Inner Insulation—Wire with a fiberglass outer and mica inner insulation is the common choice for steel mills, iron mills, and glass manufacturing. You may know it as MG wire.
    Temp.,
    ° F
    Per Ft.
    AWG
    Wire Strand
    Count
    Current @ Temp.
    OD
    Min.
    Max.
    Outer Jacket
    Color
    Flexibility
    Cable
    Designation
    Wire Material
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    Stranded Wire with Fiberglass Fabric Outer Jacket and Mica Inner Insulation
     
    600V AC/600V DC
    2
    133/23
    315 amp @ 86° F
    230 amp @ 600° F
    0.45"-40840BeigeFlexibleMG
    Nickel-Plated CopperCSA Certified, UL Listed
    5, 10, 25, 508209K25000000000000
     

    Chemical-Resistant Continuous-Flex Lead Wire

    Insulated with TPE, this wire won’t break down from oil, coolant, or chemicals, and it carries a strong signal even when repeatedly bent. This makes it great for greasy equipment on automated lines, such as lubricated cable carriers. Its insulation also stands up to moisture and sunlight, so you can use this wire outdoors. This wire is flame rated FT1, which means it meets requirements for preventing the spread of fire.
    Stranded Wire with TPE Outer Jacket
    Image of Product. Unshielded with 90° Torsion Angle. Front orientation. Unshielded. Chemical-Resistant Continuous-Flex Lead Wire, .
    Image of Product. Shielded with 180° Torsion Angle. Front orientation. Shielded. Chemical-Resistant Continuous-Flex Lead Wire, .

    Unshielded with 90° Torsion Angle

    Shielded with 180° Torsion Angle

    Unshielded—Unshielded wire works in most applications. You can twist it 90° while pulling and bending it at the same time.
    Shielded—Choose shielded wire if you need protection against signal interference from nearby equipment, such as variable frequency drives or small motors.
    Spiral Shield—Spiral-shielded wire balances good signal interference and flexibility. It's the most flexible wire we offer, so it will bend, flex, and twist 180° without stretching or snapping.
    Per Ft.
    AWG
    Current @
    Temp.
    Temp. Range,
    ° F
    OD
    Torsion
    Angle
    Outer Jacket
    Color
    Performance
    Environment
    Clean Room
    Std.
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Unshielded
     
    Copper Wire—1,000V AC
    2
    162 amp @ 86° F-30 to 1900.49"90°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K16000000000000
     
    Shielded—Spiral Shield
     
    Copper Wire—1,000V AC
    2
    158 amp @ 86° F-30 to 1900.61"180°BlackChemical Resistant, Flame RetardantClean Room
    ISO Class 1
    C-UL Recognized Component, UL Recognized Component
    UL 2556 FT1
    10, 25, 50, 1009192K580000000000
     

    Flame-Resistant Welding Cable

    Image of Product. Front orientation. Welding Cable. Flame-Resistant Welding Cable.
    Image of Specification. Front orientation. Contains Border. Welding Cable. Flame-Resistant Welding Cable, Flexible, Stranded Wire Class M.

    This cable meets Mine Safety and Health Administration (MSHA) standards for flame resistance. The insulation resists abrasion and chemicals.
    Stranded Wire Class M—Class M cable is more flexible and durable than Class K cable.
    Outer
    Jacket
    Per Ft.
    AWG
    Stranded
    Wire Class
    Wire Strand
    Count
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-249
    250-Up
    600V AC/600V DC
     
    Flexible
    2
    M1,634/34PolyethyleneOrange-55 to 190UL 2556 VW-1
    CSA Certified, MSHA Accepted, UL Listed
    10, 20, 25, 30, 50, 100, 2507818A1200000000000
     

    Aluminum Building Wire

    Image of Product. Side1 orientation. Building Wire. Aluminum Building Wire.
    Mend or extend aluminum wire often found in older buildings. This wire isn’t recommended for new wiring, since it’s more likely to overheat than copper when conducting electricity. However, it’s safer to maintain existing aluminum wire with aluminum rather than mixing materials. Building wire is also known as branch circuit wire.
    This wire has an outer layer of nylon insulation that won't degrade from oil and water. It’s designed to be pulled through conduit without pulling lubricants. THHN and THWN-2 designated, this wire can be used in damp places.
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    Stranded Wire with Nylon Outer Jacket and PVC Inner Insulation
     
    600V AC/600V DC
    2
    100 amp @ 86° F0.36"-40 to 190BlackTHHN, THWN-2
    UL Listed
    6082N1300000000000000000000000000000000
     

    Corrosion-Resistant Battery Wire

    Connect batteries in generators, forklifts, and other vehicles in corrosive environments. Also known as marine wire, this copper wire is tin plated to resist corrosion from salt water, battery acid, and oil. Designed for boats, it's a good choice for use outdoors. The PVC outer jacket stands up to fuel and oil. Wire strand count is the number of strands followed by the size of the individual strand.
    Stranded Wire with PVC Outer Jacket
    Image of Product. Front orientation. Battery Wire. Corrosion-Resistant Battery Wire.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    600V AC
    2
    665/30Not Rated0.43"0 to 220Red6444N41000000000000000000000
    2
    665/30Not Rated0.47"0 to 220Black6444N42000000000000000000
     

    Distribution Blocks

    With the help of distribution blocks, you can take a high-current wire from your power source and connect it to one or more electrical devices.
    Screw-Clamp Terminal Input Connection
    Image of Product. Front orientation. Contains Annotated. Distribution Blocks. Screw-Clamp Terminal Input Connection.
    Image of Product. Terminal Block End Stop. Front orientation. Terminal Block End Stops.

    Terminal

    Block End

    Stop

    Blocks with a screw-clamp terminal input wire connection have a current rating based on NEC table 310-16 using 75° C copper wire.
    Extendable—Extendable blocks attach to each other to create custom-sized distribution blocks.
    Jumper Cable Terminal—Blocks with a jumper cable terminal connect to other blocks to increase the number of outputs.
    Detachable Cover—Blocks with a detachable cover prevent accidental contact with live circuits.
    End Stops—End stops (sold separately) mount at the end of a group of blocks to prevent movement.
    Distribution Blocks
    End Stops
    No. of
    Connections Per Circuit
    Current per
    Circuit, amp
    Voltage
    Input (For
    Wire Ga.)
    Output (For Wire Ga.)
    Wd.
    Ht.
    Dp.
    Enclosure
    Rating
    Certification
    Flammability
    Rating
    Features
    Each
    Each
    DIN-Rail Mount
     
    1 Circuit
    115600V AC/600V DC1 (14-2)1 (14-2)3/4"4 1/8"1 11/16"IP20
    UL Listed, CE Marked
    UL 94 V-0
    6367T25000000———0
    175600V AC/600V DC1 (14-2/0)1 (14-2/0)1"3"2 9/16"UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    Detachable Cover6367T1100000———0
    200600V AC/600V DC1 (14-3/0)4 (14-2)1 1/8"3 5/8"2 11/16"IP20
    UL Listed, CSA Certified, CE Marked
    UL 94 V-0
    6367T2700000———0
    2301,000V AC/1,000V DC1 (2-250 MCM)2 (14-2), 5 (14-6), 4 (14-8)1 13/16"3 3/4"2 3/8"UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    6367T21000007641K3500000
    335600V AC/600V DC1 (6-400 MCM)8 (14-2)2 1/4"4 3/4"3 5/16"IP20
    UL Recognized Component, CE Marked
    UL 94 V-0
    6367T2800000———0
    3351,000V AC/1,000V DC1 (3/0-400 MCM)2 (14-2), 5 (14-6), 4 (14-8)1 13/16"3 3/4"2 3/8"IP10, NEMA 1
    UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    Jumper Cable Terminal6367T53000007641K350000
     
    2 Circuits
    175600V AC/600V DC1 (14-2/0)1 (14-2/0)2"3"2 9/16"UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    Detachable Cover6367T1200000———0
     
    3 Circuits
    175600V AC/600V DC1 (14-2/0)1 (14-2/0)2 5/8"3"2 9/16"UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    Detachable Cover6367T1300000———0
     
    Surface Mount
     
    1 Circuit
    335600V AC/600V DC2 (14-4/0)8 (14-2)2 1/4"4 3/8"3 3/16"IP20
    UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    Extendable6367T4300000———0
    760600V AC2 (4-4/0)8 (14- 2/0)2 1/2"4.63"3 3/8"IP20
    UL Listed, CSA Certified, CE Marked
    UL 94 V-0
    Extendable6367T45000000———0
     
    3 Circuits
    335600V AC/600V DC1 (14-4/0)6 (14-2)5 5/8"5"3 15/16"UL Listed, C-UL Listed
    6367T46000000———0
    510600V AC/600V DC2 (6-4/0)8 (14-2)5 5/8"5"3 15/16"UL Listed, C-UL Listed
    6367T42000000———0
     
    Stud-Terminal Input Connection
    Image of Product. Front orientation. Contains Annotated. Distribution Blocks. Stud-Terminal Input Connection.
    Detachable Cover—Blocks with a detachable cover prevent accidental contact with live circuits.
    No. of
    Connections Per Circuit
    Current per
    Circuit, amp
    Voltage
    Input (For
    Wire Ga.)
    Output (For
    Wire Ga.)
    Terminal
    Size
    Wd.
    Ht.
    Dp.
    Certification
    Flammability
    Rating
    Features
    Each
    DIN-Rail Mount
     
    1 Circuit
    200600V AC/600V DC1 (14-3/0)1 (14-3/0)1/4"
    1"3"2 9/16"UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    Detachable Cover6367T34000000
     
    2 Circuits
    200600V AC/600V DC1 (14-3/0)1 (14-3/0)1/4"
    2"3"2 9/16"UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    Detachable Cover6367T3500000
     
    3 Circuits
    200600V AC/600V DC1 (14-3/0)1 (14-3/0)1/4"
    2 5/8"3"2 9/16"UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    Detachable Cover6367T3600000
     
    Surface Mount
     
    1 Circuit
    310600V AC/600V DC1 (14-4/0)1 (14-4/0)3/8"
    2"4"3 1/2"UL Recognized Component, CSA Certified
    UL 94 V-0
    Detachable Cover6367T3700000
     
    2 Circuits
    310600V AC/600V DC1 (14-4/0)1 (14-4/0)3/8"
    3 5/8"4"3 1/2"UL Recognized Component, CSA Certified
    UL 94 V-0
    Detachable Cover6367T38000000
     
    3 Circuits
    310600V AC/600V DC1 (14-4/0)1 (14-4/0)3/8"
    5 3/8"4"3 1/2"UL Recognized Component, CSA Certified
    UL 94 V-0
    Detachable Cover6367T39000000
     
    Bus-Bar Input Connection
    Image of Product. Front orientation. Contains Annotated. Distribution Blocks. Bus-Bar Input Connection.
    Image of Product. Terminal Block End Stop. Front orientation. Terminal Block End Stops.

    Terminal

    Block End

    Stop

    Choose blocks with a bus-bar input wire connection to distribute power from flat conductors without the need for an adapter.
    End Stops—End stops (sold separately) mount at the end of a group of blocks to prevent movement.
    Distribution Blocks
    End Stops
    No. of
    Connections Per Circuit
    Bus
    Bar, mm
    Current per
    Circuit, amp
    Voltage
    Input (For
    Wire Ga.)
    Output (For Wire Ga.)
    Wd.
    Ht.
    Dp.
    Wd.
    Thk.
    Enclosure
    Rating
    Certification
    Flammability
    Rating
    Each
    Each
    DIN-Rail Mount
     
    1 Circuit
    4201,000V AC/1,000V DC12 (14-2), 4 (14-8), 5 (14-6)1 13/16"4"2 3/8"2510IP20, NEMA 1
    UL Recognized Component, CSA Certified, CE Marked
    UL 94 V-0
    6367T560000007641K3500000
     