About Wire and Cable
Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.
Armored Building Cable
MC, XHHW-2 Stranded Wire
Inner Insulation | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. of Wires | Cable AWG | Current @ Temp. | OD | Outer Jacket Material | Material | Color | Temp. Range, ° F | Features | Hazardous Location Rating | Specs. Met | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | 250 ft. Long | |||
600V AC/600V DC | |||||||||||||||||||
| 14 | 3 | 14/3 | 15 amp @ 86° F | 0.64" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T31 | 000000 | 000000 | 0000000 | 0000000 | 0000000 | ||
| 12 | 3 | 12/3 | 20 amp @ 86° F | 0.65" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T32 | 00000 | 00000 | 000000 | — | 000000 | ||
| 12 | 4 | 12/4 | 20 amp @ 86° F | 0.68" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T33 | 00000 | 00000 | 000000 | 000000 | 000000 | ||
| 10 | 3 | 10/3 | 30 amp @ 86° F | 0.7" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T34 | 00000 | 000000 | 000000 | 000000 | 000000 | ||
| 10 | 4 | 10/4 | 30 amp @ 86° F | 0.74" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T35 | 00000 | 000000 | 000000 | 000000 | 000000 | ||
Armored Fire Alarm Cable
Outer Jacket | Inner Insulation | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. of Wires | Cable AWG | OD | Material | Color | Material | Color | Temp. Range, ° F | Features | Armored Cable Type | Hazardous Location Rating | Certification | Flammability Rating | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | 250 ft. Long | |||
Unshielded Solid Wire | |||||||||||||||||||||
300V AC/300V DC | |||||||||||||||||||||
| 18 | 4 | 18/4 | 0.43" | Aluminum | Red | Nylon, PVC | Black, Blue, Green, Red, White | -10 to 190 | Insulated Ground Wire | MC-FPLP | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL Listed | UL 2556 VW-1 | 6123N12 | 000000 | 000000 | 000000 | 0000000 | 0000000 | ||
Shielded Solid Wire | |||||||||||||||||||||
300V AC/300V DC | |||||||||||||||||||||
| 18 | 2 | 18/2 | 0.39" | Aluminum | Red | Nylon, PVC | Black, White | -10 to 190 | Uninsulated Ground Wire | MC-FPLP | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL Listed | UL 2556 VW-1 | 6123N11 | 00000 | 00000 | 00000 | 00000 | 000000 | ||