Lg., ft. | AWG | Current, amp | Cable Designation | For Use Outdoors | Hazardous Location Rating | Certification | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|
NEMA 5-20 Plug × Socket—125V AC | ||||||||||
Black | ||||||||||
| 50 | 10 | 20 | SEOOW | Yes | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups F, G | CSA Certified | 2998N11 | 000000000 | ||
Armored Building Cable
MC, THHN Solid Wire
Inner Insulation | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. of Wires | Cable AWG | Current @ Temp. | OD | Outer Jacket Material | Material | Color | Temp. Range, ° F | Features | Hazardous Location Rating | Specs. Met | Flammability Rating | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | 250 ft. Long | |||
600V AC | ||||||||||||||||||||
| 14 | 2 | 14/2 | 15 amp @ 86° F | 0.44" | Aluminum | PVC | Black, Green, White | 15 to 190 | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569 | UL 2556 VW-1 | 6730T21 | 000000 | 000000 | 000000 | 0000000 | 0000000 | ||
| 14 | 3 | 14/3 | 15 amp @ 86° F | 0.46" | Aluminum | PVC | Black, Green, Red, White | 15 to 190 | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569 | UL 2556 VW-1 | 6730T22 | 00000 | 00000 | 000000 | 000000 | 000000 | ||
| 14 | 4 | 14/4 | 15 amp @ 86° F | 0.49" | Aluminum | PVC | Black, Blue, Green, Red, White | 15 to 190 | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569 | UL 2556 VW-1 | 6730T23 | 00000 | 00000 | 000000 | — | 000000 | ||
| 12 | 2 | 12/2 | 20 amp @ 86° F | 0.48" | Aluminum | PVC | Black, Green, White | 15 to 190 | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569 | UL 2556 VW-1 | 6730T24 | 00000 | 00000 | 00000 | 000000 | 000000 | ||
| 12 | 3 | 12/3 | 20 amp @ 86° F | 0.51" | Aluminum | PVC | Black, Green, Red, White | 15 to 190 | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569 | UL 2556 VW-1 | 6730T25 | 00000 | 00000 | 000000 | 000000 | 000000 | ||
| 12 | 4 | 12/4 | 20 amp @ 86° F | 0.54" | Aluminum | PVC | Black, Blue, Green, Red, White | 15 to 190 | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569 | UL 2556 VW-1 | 6730T26 | 00000 | 000000 | 000000 | 000000 | 000000 | ||
| 10 | 2 | 10/2 | 30 amp @ 86° F | 0.54" | Aluminum | PVC | Black, Green, White | 15 to 190 | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569 | UL 2556 VW-1 | 6730T27 | 00000 | 00000 | 000000 | 000000 | 000000 | ||
| 10 | 3 | 10/3 | 30 amp @ 86° F | 0.58" | Aluminum | PVC | Black, Green, Red, White | 15 to 190 | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569 | UL 2556 VW-1 | 6730T28 | 00000 | 000000 | 000000 | 000000 | 000000 | ||
| 10 | 4 | 10/4 | 30 amp @ 86° F | 0.62" | Aluminum | PVC | Black, Blue, Green, Red, White | 15 to 190 | Insulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569 | UL 2556 VW-1 | 6730T29 | 00000 | 000000 | 000000 | 000000 | 00000000 | ||