    27 Products

    Hazardous Location Relays

    Image of Product. Front orientation. Contains Annotated. Relays. Hazardous Location Relays, Screw Terminals.
    Image of Product. Front orientation. Relays. Hazardous Location Relays, Spring-Clamp Terminals.
    Image of Product. Front orientation. Contains Annotated. Relays. Hazardous Location Relays, Circular-Pin Terminals—Hermetically Sealed.

    Screw Terminals

    Spring-Clamp

    Terminals

    Circular-Pin

    Terminals—Hermetically

    Sealed

    Image of Product. Back orientation. Relays. Hazardous Location Relays, Quick-Disconnect Terminals—Hermetically Sealed.
    Image of Product. Front orientation. Relay Sockets. Hazardous Location Relays.

    Quick-Disconnect

    Terminals—Hermetically

    Sealed

    Sockets with

    Screw Terminals

    Sealed for safety, these relays are a good choice for hazardous locations where combustible or corrosive gases may be present.
    Screw Terminals—Relays with screw terminals are considered interface relays, so they’re placed between your controller and components to isolate the input and output circuits. This means they protect your component from voltage spikes while amplifying the relay’s signal and reducing interference for reliable transmission. They are often used for switching applications, such as small motors and pilot lights. The included relay socket mounts on 35 mm DIN rail (also known as DIN 3 rail).
    Spring-Clamp Terminals—Relays with spring-clamp terminals are considered interface relays, so they’re placed between your controller and components to isolate the input and output circuits. This means they protect your component from voltage spikes while amplifying the relay’s signal and reducing interference for reliable transmission. They are often used for switching applications, such as small motors and pilot lights. The included relay socket mounts on 35 mm DIN rail (also known as DIN 3 rail). Relays with spring-clamp terminals connect and disconnect to wires without needing to turn screws. With no screws to shake loose with vibration, the terminals hold tight over time.
    Circular-Pin Terminal and Quick-Disconnect Terminal—Relays with circular-pin terminals or quick-disconnect terminals are hermetically sealed—completely air- and watertight—to shield internal parts from gases, moisture, and other contaminants. They plug into relay sockets (sold separately) for easy installation.
    Sockets with Screw Terminals—Relay sockets mount to 35 mm DIN rail (also known as DIN 3 rail) or flat surfaces.
    Relays
    Sockets with
    Screw Terminals
    No. of
    Terminals
    Input Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    hp @ Switching
    Voltage
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Enclosure
    Rating
    Hazardous Location Rating
    Each
    Each
    Screw Terminals
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    512V AC, 12V DC15.56 amp @ 240V AC/30V DC400V AC/125V DC2.9"0.2"3.5"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N311000000———0
    512V AC, 12V DC2912 amp @ 240V AC/24V DC400V AC/300V DC2.9"0.6"3.5"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N31200000———0
    524V AC, 24V DC13.56 amp @ 240V AC/30V DC400V AC/125V DC3.5"0.2"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N1100000———0
    524V AC, 24V DC13.516 amp @ 240V AC/24V DC400V AC/300V DC3.5"0.6"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N1500000———0
    548V AC, 48V DC46 amp @ 240V AC/30V DC400V AC/125V DC3.5"0.2"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N1200000———0
    548V AC, 48V DC416 amp @ 240V AC/24V DC400V AC/300V DC3.5"0.6"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N1700000———0
    5120V AC, 120V DC3.56 amp @ 240V AC/30V DC400V AC/125V DC3.5"0.2"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N1300000———0
    5120V AC, 120V DC3.516 amp @ 240V AC/24V DC400V AC/300V DC3.5"0.6"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N1900000———0
    5240V AC, 240V DC3.56 amp @ 240V AC/30V DC400V AC/125V DC3.5"0.2"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N1400000———0
    5240V AC, 240V DC3.516 amp @ 240V AC/24V DC400V AC/300V DC3.5"0.6"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N2200000———0
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    824V AC, 24V DC13.58 amp @ 240V AC/24V DC400V AC/300V DC3.5"0.6"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N1600000———0
    848V AC, 48V DC48 amp @ 240V AC/24V DC400V AC/300V DC3.5"0.6"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N1800000———0
    8120V AC, 120V DC3.58 amp @ 240V AC/24V DC400V AC/300V DC3.5"0.6"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N2100000———0
    8240V AC, 240V DC3.58 amp @ 240V AC/24V DC400V AC/300V DC3.5"0.6"2.9"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N2300000———0
     
    Spring-Clamp Terminals
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    512V AC, 12V DC15.56 amp @ 240V AC/30V DC400V AC/125V DC2.9"0.2"3.7"IP20
    NEC Class I Division 2 Groups A, B, C, D
    8163N1100000———0
    512V AC, 12V DC2912 amp @ 240V AC/24V DC400V AC/300V DC2.9"0.6"3.7"IP20
    NEC Class I Division 2 Groups A, B, C, D
    8163N1400000———0
    524V AC, 24V DC13.56 amp @ 240V AC/30V DC400V AC/125V DC2.9"0.2"3.7"IP20
    NEC Class I Division 2 Groups A, B, C, D
    8163N1200000———0
    524V AC, 24V DC2012 amp @ 240V AC/24V DC400V AC/300V DC2.9"0.6"3.7"IP20
    NEC Class I Division 2 Groups A, B, C, D
    8163N1500000———0
    5120V AC, 120V DC3.56 amp @ 240V AC/30V DC400V AC/125V DC2.9"0.2"3.7"IP20
    NEC Class I Division 2 Groups A, B, C, D
    8163N1300000———0
    5120V AC, 120V DC412 amp @ 240V AC/24V DC400V AC/300V DC2.9"0.6"3.7"IP20
    NEC Class I Division 2 Groups A, B, C, D
    8163N1600000———0
     
    Circular-Pin Terminals—Hermetically Sealed
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    8120V AC1012 amp @ 120V AC/24V DC300V AC1/3 hp @ 120V AC1.6"1.4"2.1"NEC Class I Division 2 Groups A, B, C, D
    7125T320000007125T4100000
    824V DC3812 amp @ 120V AC/24V DC300V AC1/3 hp @ 120V AC1.6"1.4"2.1"NEC Class I Division 2 Groups A, B, C, D
    7125T340000007125T410000
     
    3 Circuits Controlled with 3 Off or 3 On—3PDT
    11120V AC10012 amp @ 120V AC/240V AC300V AC1/3 hp @ 120V AC1.6"1.4"2.1"NEC Class I Division 2 Groups A, B, C, D
    7125T1110000007122K210000
     
    Quick-Disconnect Terminals—Hermetically Sealed
     
    4 Circuits Controlled with 4 Off or 4 On—4PDT
    14120V AC1003 amp @ 120V AC/240V AC240V AC1/10 hp @ 120V AC1.2"0.9"1.3"0.125"NEC Class I Division 2 Groups A, B, C, D
    8161N110000007122K2500000
     