About Wire and Cable
Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.
Building Wire
Stranded Wire with Nylon Outer Jacket and PVC Inner Insulation
Shorter Lengths | Longer Lengths | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | OD | Temp. Range, ° F | Cable Designation | Certification | Flammability Rating | Choose an Outer Jacket Color | Choose a Length, ft. | Per Ft. | Lg., ft. | Each | ||||
600V AC/600V DC | ||||||||||||||||
| 8 | 19/21 | 55 amp @ 86° F | 0.21" | -10 to 190 | THHN, THWN-2 | C-UL Listed, UL Listed | UL 2556 VW-1 | Black, Blue, Brown, Green, Orange, Red, White, Yellow | 10, 25, 50, 100, 250 | 7715T16 | 00000 | 500 | 7715T56 | 0000000 | ||
Stranded Wire with Polyethylene Outer Jacket
Machine Tool Wire
600V AC
AWG | Wire Strand Count | Current @ Temp. | OD | Temp. Range, ° F | Outer Jacket Material | Flexibility | Cable Designation | Specs. Met | Certification | Flammability Rating | Choose an Outer Jacket Color | Choose a Length, ft. | Per Ft. | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stranded Wire | ||||||||||||||||
| 8 | 19/21 | 83 amp @ 86° F | 0.21" | 0 to 190 | PVC | Flexible | MTW | UL 1063 | C-UL Listed, UL Listed | UL 2556 VW-1 | Blue | 10, 25, 50, 100, 250 | 9874T821 | 00000 | ||
| 8 | 19/21 | 83 amp @ 86° F | 0.24" | 0 to 190 | PVC | Flexible | MTW | UL 1063 | CSA Certified, UL Listed | UL 2556 VW-1 | Black, Green, Red, White | 10, 25, 50, 100, 250 | 9874T16 | 0000 | ||
600V AC
AWG | Wire Strand Count | Current @ Temp. | OD | Temp. Range, ° F | Outer Jacket Material | Flexibility | Cable Designation | Specs. Met | Certification | Flammability Rating | Lg., ft. | Choose an Outer Jacket Color | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stranded Wire | ||||||||||||||||
| 8 | 19/21 | 83 amp @ 86° F | 0.21" | 0 to 190 | PVC | Flexible | MTW | UL 1063 | C-UL Listed, UL Listed | UL 2556 VW-1 | 500 | Blue | 9874T892 | 0000000 | ||
| 8 | 19/21 | 83 amp @ 86° F | 0.24" | 0 to 190 | PVC | Flexible | MTW | UL 1063 | CSA Certified, UL Listed | UL 2556 VW-1 | 500 | Black, Green, Red, White | 9874T26 | 000000 | ||
Power Cable
Outer Jacket | Per Ft. | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Temp., ° F | Flammability Rating | Certification | Choose a Length, ft. | 1-249 | 250-Up | |||
600V AC | ||||||||||||
SEOOW Cable | ||||||||||||
| 8/3 | 40 amp @ 86° F | TPE | Black | -55 to 220 | — | — | 10, 20, 25, 50, 100, 250 | 7080K37 | 00000 | 00000 | ||
| 8/4 | 35 amp @ 86° F | TPE | Black | -55 to 220 | — | — | 10, 20, 25, 50, 100, 250 | 7080K41 | 0000 | 0000 | ||
SOOW Cable | ||||||||||||
| 8/3 | 40 amp @ 86° F | EPDM | Black | -40 to 190 | UL 2556 FT2 | CSA Certified, UL Listed | 10, 25, 50, 100, 250 | 7081K35 | 00000 | 0000 | ||
| 8/4 | 35 amp @ 86° F | EPDM | Black | -40 to 190 | UL 2556 FT2 | CSA Certified, UL Listed | 10, 25, 50, 100, 250 | 7081K82 | 00000 | 00000 | ||
| 8/5 | 28 amp @ 86° F | EPDM | Black | -40 to 190 | — | — | 10, 25, 50, 100, 250 | 7081K44 | 00000 | 0000 | ||
High-Temperature Lead Wire
Temp., ° F | Per Ft. | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | OD | Min. | Max. | Outer Jacket Color | Flexibility | Cable Designation | Wire Material | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Stranded Wire with Fiberglass Fabric Outer Jacket and Mica Inner Insulation | |||||||||||||||||
600V AC/600V DC | |||||||||||||||||
| 8 | 133/29 | 130 amp @ 86° F 87 amp @ 600° F | 0.27" | -40 | 840 | Beige | Flexible | MG | Nickel-Plated Copper | CSA Certified, UL Listed | — | 10, 25, 50, 100 | 8209K22 | 00000 | 00000 | ||
Stranded Wire with Silicone-Coated Fiberglass Fabric Outer Jacket and Mica Inner Insulation | |||||||||||||||||
600V AC/600V DC | |||||||||||||||||
| 8 | 133/29 | 130 amp @ 86° F | 0.27" | — | 1,020 | Beige | Flexible | MG | Nickel-Plated Copper | CSA Certified, UL Listed | — | 10, 25, 50, 100, 250 | 8209K36 | 00000 | 0000 | ||
Stranded Wire with Fiberglass Fabric Outer Jacket and PTFE Inner Insulation | |||||||||||||||||
600V AC | |||||||||||||||||
| 8 | 133/29 | 88 amp @ 86° F 30 amp @ 400° F | 0.23" | -65 | 480 | Beige | Flexible | TGGT | Nickel-Plated Copper | CSA Certified, UL Recognized Component | — | 10, 25, 50, 100 | 8240K36 | 00000 | 00000 | ||
Stranded Wire with Ceramic Fabric Outer Jacket and Mica Inner Insulation | |||||||||||||||||
300V AC | |||||||||||||||||
| 8 | 168/30 | 43 amp @ 86° F | 0.29" | -40 | 1,830 | Beige | Bend and Stay | — | Nickel | — | UL 2556 VW-1 | 5, 10, 25, 50, 100 | 9457T26 | 00000 | 00000 | ||
Battery Wire
Vehicle Wire
Abrasion-Resistant Lead Wire
Stranded Wire with FEP Outer Jacket
Stranded Wire with Silicone Rubber Outer Jacket
Vehicle Cable
Welding Cable
Chemical-Resistant Continuous-Flex Lead Wire
Stranded Wire with TPE Outer Jacket
Per Ft. | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Current @ Temp. | Temp. Range, ° F | OD | Torsion Angle | Outer Jacket Color | Performance | Environment | Clean Room Std. | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Unshielded | ||||||||||||||||
Copper Wire—1,000V AC | ||||||||||||||||
| 8 | 74 amp @ 86° F | -30 to 190 | 0.31" | 90° | Black | Chemical Resistant, Flame Retardant | Clean Room | ISO Class 1 | C-UL Recognized Component, UL Recognized Component | UL 2556 FT1 | 10, 25, 50, 100 | 9192K13 | 00000 | 00000 | ||
Shielded—Braided Shield | ||||||||||||||||
Copper Wire—1,000V AC | ||||||||||||||||
| 8 | 74 amp @ 86° F | -30 to 190 | 0.33" | — | Black | Chemical Resistant, Flame Retardant | Clean Room | ISO Class 1 | C-UL Recognized Component, UL Recognized Component | UL 2556 FT1 | 10, 25, 50, 100 | 9192K53 | 0000 | 0000 | ||
Shielded—Spiral Shield | ||||||||||||||||
Copper Wire—1,000V AC | ||||||||||||||||
| 8 | 72 amp @ 86° F | -30 to 190 | 0.41" | 180° | Black | Chemical Resistant, Flame Retardant | Clean Room | ISO Class 1 | C-UL Recognized Component, UL Recognized Component | UL 2556 FT1 | 10, 25, 50, 100 | 9192K55 | 00000 | 00000 | ||
Continuous-Flex Power Cable
Outer Jacket | Per Ft. | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Bend Radius | Material | Color | Temp., ° F | Flammability Rating | Certification | Clean Room Std. | Choose a Length, ft. | 1-99 | 100-Up | |||
1,000V AC | ||||||||||||||
Unshielded | ||||||||||||||
| 8/4 | 69 amp @ 86° F | 5.18" | PVC | Black | 25 to 155 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | ISO Class 2 | 5, 10, 20, 30, 50, 100 | 9243K17 | 000000 | 000000 | ||
| 8/5 | 51 amp @ 86° F | 5.93" | PVC | Black | 25 to 155 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | ISO Class 2 | 5, 10, 20, 30, 50, 100 | 9243K18 | 00000 | 00000 | ||
Shielded | ||||||||||||||
| 8/4 | 69 amp @ 86° F | 6.08" | PVC | Black | 25 to 155 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | ISO Class 2 | 5, 10, 20, 30, 50, 100 | 9243K38 | 00000 | 00000 | ||
| 8/5 | 51 amp @ 86° F | 6.68" | PVC | Black | 25 to 155 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | ISO Class 2 | 5, 10, 20, 30, 50, 100 | 9243K39 | 00000 | 00000 | ||
No-Conduit-Required Control Cable
Outer Jacket | Per Ft. | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Cable Designation | Temp., ° F | Flammability Rating | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
600V AC | |||||||||||||
Unshielded | |||||||||||||
| 8/4 | 55 amp @ 86° F | PVC | Black | TC-ER | -10 to 190 | UL 2556 FT4 | C-UL Listed, CSA Certified, UL Listed | 10, 20, 30, 50, 100 | 6452T59 | 00000 | 00000 | ||
| 8/5 | 44 amp @ 86° F | PVC | Black | TC-ER | -10 to 190 | UL 2556 FT4 | C-UL Listed, CSA Certified, UL Listed | 10, 20, 30, 50, 100 | 6452T31 | 00000 | 00000 | ||
Double Shielded | |||||||||||||
| 8/4 | 55 amp @ 86° F | PVC | Black | TC-ER | -10 to 190 | UL 2556 FT4 | C-UL Listed, CSA Certified, UL Listed | 10, 20, 30, 50, 100 | 6452T69 | 00000 | 00000 | ||
Heavy Duty Harsh-Environment Power Cable
Outer Jacket | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Temp., ° F | Certification | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | |||
2,000V AC/2,000V DC | ||||||||||||
Type W Cable | ||||||||||||
| 8/2 | 74 amp @ 86° F | EPDM | Black | -40 to 190 | CSA Certified, MSHA Accepted, UL Listed | 2962N1 | 000000 | 0000000 | 0000000 | 0000000 | ||
| 8/3 | 74 amp @ 86° F | EPDM | Black | -40 to 190 | CSA Certified, MSHA Accepted, UL Listed | 2962N4 | 000000 | 000000 | 000000 | 000000 | ||
Pendant Cable
Distribution Blocks
Screw-Clamp Terminal Input Connection
Distribution Blocks | End Stops | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Connections Per Circuit | ||||||||||||||||
Current per Circuit, amp | Voltage | Input (For Wire Ga.) | Output (For Wire Ga.) | Wd. | Ht. | Dp. | Enclosure Rating | Certification | Flammability Rating | Features | Each | Each | ||||
DIN-Rail Mount | ||||||||||||||||
1 Circuit | ||||||||||||||||
| 115 | 600V AC/600V DC | 1 (14-2) | 1 (14-2) | 3/4" | 4 1/8" | 1 11/16" | IP20 | UL Listed, CE Marked | UL 94 V-0 | — | 6367T25 | 000000 | ——— | 0 | ||
| 115 | 1,000V AC/1,000V DC | 1 (8-2) | 1 (10-6), 6 (14-6) | 1 1/8" | 3" | 2" | IP20, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | — | Jumper Cable Terminal | 6367T31 | 00000 | 7641K35 | 00000 | ||
| 160 | 1,000V AC/1,000V DC | 1 (6-2/0) | 1 (10-6), 6 (14-6) | 1 1/8" | 3" | 2" | IP10, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Jumper Cable Terminal | 6367T51 | 00000 | 7641K35 | 0000 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 1 (14-2/0) | 1" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T11 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 1" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T14 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 1" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover, Quick-Disconnect Load Connection | 6367T22 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 6 (14-4) | 1" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T17 | 00000 | ——— | 0 | ||
| 175 | 1,000V AC/1,000V DC | 2 (6-2/0) | 10 (14-6) | 1 13/16" | 2 7/8" | 2 1/16" | IP10, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Jumper Cable Terminal | 6367T52 | 00000 | 7641K35 | 0000 | ||
| 200 | 600V AC/600V DC | 1 (14-3/0) | 4 (14-2) | 1 1/8" | 3 5/8" | 2 11/16" | IP20 | UL Listed, CSA Certified, CE Marked | UL 94 V-0 | — | 6367T27 | 00000 | ——— | 0 | ||
| 230 | 1,000V AC/1,000V DC | 1 (2-250 MCM) | 2 (14-2), 5 (14-6), 4 (14-8) | 1 13/16" | 3 3/4" | 2 3/8" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | — | 6367T21 | 00000 | 7641K35 | 0000 | ||
| 335 | 600V AC/600V DC | 1 (6-400 MCM) | 8 (14-2) | 2 1/4" | 4 3/4" | 3 5/16" | IP20 | UL Recognized Component, CE Marked | UL 94 V-0 | — | 6367T28 | 00000 | ——— | 0 | ||
| 335 | 1,000V AC/1,000V DC | 1 (3/0-400 MCM) | 2 (14-2), 5 (14-6), 4 (14-8) | 1 13/16" | 3 3/4" | 2 3/8" | IP10, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Jumper Cable Terminal | 6367T53 | 00000 | 7641K35 | 0000 | ||
2 Circuits | ||||||||||||||||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 1 (14-2/0) | 2" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T12 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T15 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover, Quick-Disconnect Load Connection | 6367T23 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 6 (14-4) | 2" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T18 | 00000 | ——— | 0 | ||
3 Circuits | ||||||||||||||||
| 115 | 1,000V AC/1,000V DC | 1 (8-2) | 1 (10-6), 6 (14-6) | 3 5/16" | 3" | 2" | IP20, NEMA 1 | UL Recognized Component, CE Marked | — | — | 6367T33 | 00000 | 7641K35 | 0000 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 1 (14-2/0) | 2 5/8" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T13 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2 5/8" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T16 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 4 (14-4) | 2 5/8" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover, Quick-Disconnect Load Connection | 6367T24 | 00000 | ——— | 0 | ||
| 175 | 600V AC/600V DC | 1 (14-2/0) | 6 (14-4) | 2 5/8" | 3" | 2 9/16" | — | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T19 | 000000 | ——— | 0 | ||
| 175 | 1,000V AC/1,000V DC | 1 (6-2/0) | 1 (10-6), 6 (14-6) | 3 5/16" | 3" | 2" | IP10, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | — | 6367T54 | 00000 | 7641K35 | 0000 | ||
Surface Mount | ||||||||||||||||
1 Circuit | ||||||||||||||||
| 335 | 600V AC/600V DC | 2 (14-4/0) | 8 (14-2) | 2 1/4" | 4 3/8" | 3 3/16" | IP20 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Extendable | 6367T43 | 00000 | ——— | 0 | ||
| 760 | 600V AC | 2 (4-4/0) | 8 (14- 2/0) | 2 1/2" | 4.63" | 3 3/8" | IP20 | UL Listed, CSA Certified, CE Marked | UL 94 V-0 | Extendable | 6367T45 | 000000 | ——— | 0 | ||
| 760 | 600V AC/600V DC | 2 (4-4/0) | 12 (14-4) | 2 1/2" | 4.63" | 3 3/8" | IP20 | UL Listed, CSA Certified, CE Marked | UL 94 V-0 | Extendable | 6367T41 | 000000 | ——— | 0 | ||
3 Circuits | ||||||||||||||||
| 335 | 600V AC/600V DC | 1 (14-4/0) | 6 (14-2) | 5 5/8" | 5" | 3 15/16" | — | UL Listed, C-UL Listed | — | — | 6367T46 | 000000 | ——— | 0 | ||
| 350 | 600V AC/600V DC | 2 (14-2/0) | 6 (14-4) | 5 5/8" | 5" | 3 15/16" | — | UL Listed, C-UL Listed | — | — | 6367T44 | 000000 | ——— | 0 | ||
| 510 | 600V AC/600V DC | 2 (6-4/0) | 8 (14-2) | 5 5/8" | 5" | 3 15/16" | — | UL Listed, C-UL Listed | — | — | 6367T42 | 000000 | ——— | 0 | ||
Stud-Terminal Input Connection
No. of Connections Per Circuit | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current per Circuit, amp | Voltage | Input (For Wire Ga.) | Output (For Wire Ga.) | Terminal Size | Wd. | Ht. | Dp. | Certification | Flammability Rating | Features | Each | |||
DIN-Rail Mount | ||||||||||||||
1 Circuit | ||||||||||||||
| 200 | 600V AC/600V DC | 1 (14-3/0) | 1 (14-3/0) | 1/4" | 1" | 3" | 2 9/16" | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T34 | 000000 | ||
2 Circuits | ||||||||||||||
| 200 | 600V AC/600V DC | 1 (14-3/0) | 1 (14-3/0) | 1/4" | 2" | 3 1/8" | 3 1/4" | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T35 | 00000 | ||
3 Circuits | ||||||||||||||
| 200 | 600V AC/600V DC | 1 (14-3/0) | 1 (14-3/0) | 1/4" | 2 9/16" | 3 1/8" | 3 1/4" | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | Detachable Cover | 6367T36 | 00000 | ||
Surface Mount | ||||||||||||||
1 Circuit | ||||||||||||||
| 310 | 600V AC/600V DC | 1 (14-4/0) | 1 (14-4/0) | 3/8" | 2" | 4" | 3 1/2" | UL Recognized Component, CSA Certified | UL 94 V-0 | Detachable Cover | 6367T37 | 00000 | ||
2 Circuits | ||||||||||||||
| 310 | 600V AC/600V DC | 1 (14-4/0) | 1 (14-4/0) | 3/8" | 3 5/8" | 4" | 3 1/2" | UL Recognized Component, CSA Certified | UL 94 V-0 | Detachable Cover | 6367T38 | 000000 | ||
3 Circuits | ||||||||||||||
| 310 | 600V AC/600V DC | 1 (14-4/0) | 1 (14-4/0) | 3/8" | 5 3/8" | 4" | 3 1/2" | UL Recognized Component, CSA Certified | UL 94 V-0 | Detachable Cover | 6367T39 | 000000 | ||
Bus-Bar Input Connection
Distribution Blocks | End Stops | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Connections Per Circuit | Bus Bar, mm | ||||||||||||||||
Current per Circuit, amp | Voltage | Input (For Wire Ga.) | Output (For Wire Ga.) | Wd. | Ht. | Dp. | Wd. | Thk. | Enclosure Rating | Certification | Flammability Rating | Each | Each | ||||
DIN-Rail Mount | |||||||||||||||||
1 Circuit | |||||||||||||||||
| 160 | 1,000V AC/1,000V DC | 1 | 6 (14-6) | 1 1/8" | 3" | 2" | 12 | 4 | IP20, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | 6367T55 | 000000 | 7641K35 | 00000 | ||
| 420 | 1,000V AC/1,000V DC | 1 | 2 (14-2), 4 (14-8), 5 (14-6) | 1 13/16" | 4" | 2 3/8" | 25 | 10 | IP20, NEMA 1 | UL Recognized Component, CSA Certified, CE Marked | UL 94 V-0 | 6367T56 | 00000 | 7641K35 | 0000 | ||
UV-Resistant Lead Wire
600V AC
Per Ft. | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | OD | Temp. Range, ° F | Outer Jacket Material | Outer Jacket Color | Cable Designation | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Stranded Wire | |||||||||||||||
| 8 | 157/29 | 98 amp @ 86° F | 0.28" | -40 to 190 | Cross-Linked Polyethylene | Black | PV, RHW-2 | UL Listed | UL 2556 VW-1 | 10, 25, 50, 100, 500 | 3022N78 | 00000 | 00000 | ||
2,000V AC/2,000V DC
Temp., ° F | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | OD | Min. | Max. | Outer Jacket Material | Cable Designation | Certification | Flammability Rating | Choose an Outer Jacket Color | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | |||
Stranded Wire | |||||||||||||||||
| 8 | 19/21 | 55 amp @ 86° F | 0.3" | -40 | 190 | Cross-Linked Polyethylene | PV, RHW-2 | C-UL Listed, UL Listed | UL 2556 VW-1 | Black, Red | 3022N3 | 000000 | 000000 | 000000 | 0000000 | ||
Harsh-Environment Power Cable
Outer Jacket | Per Ft. | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Temp., ° F | Specs. Met | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
600V AC | ||||||||||||
Type P Cable | ||||||||||||
| 8/4 | 40 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K25 | 00000 | 00000 | ||
Type P Cable with Bronze Armor | ||||||||||||
| 8/4 | 40 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K55 | 00000 | 00000 | ||
Grounding Wire
Flexible Grounding Wire
Power Cords
Outdoor Lead Wire
2,000V AC
AWG | Current @ Temp. | OD | Max. Temp., ° F | Outer Jacket Material | Inner Insulation Material | Outer Jacket Color | Cable Designation | Certification | Flammability Rating | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stranded Wire | ||||||||||||||||
| 8 | 55 amp @ 86° F | 0.33" | 190 | CPE | EPDM | Black | DLO, RHW-2 | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T26 | 000000 | 000000 | 0000000 | 0000000 | ||
Continuous-Flex Lead Wire
Stranded Wire with PVC Outer Jacket with Fabric Tape and PVC Inner Insulation
Per Ft. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | Temp. Range, ° F | OD | Outer Jacket Color | Performance | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Unshielded | ||||||||||||||
Copper Wire—600V AC | ||||||||||||||
| 8 | 320/32 | 80 amp @ 86° F | 45 to 190 | 0.36" | Black | Flame Retardant | CSA Certified, UL Recognized Component | UL 2556 VW-1 | 10, 25, 50, 100 | 9192K4 | 00000 | 00000 | ||
High-Voltage Continuous-Flex Lead Wire
Stranded Wire with Silicone Rubber Outer Jacket
Per Ft. | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | Temp. Range, ° F | OD | Outer Jacket Color | Performance | Environment | Clean Room Std. | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Unshielded | ||||||||||||||||
Tin-Plated Copper Wire—59,000V AC/42,000V DC | ||||||||||||||||
| 8 | 1,666/40 | 65 amp @ 86° F | -85 to 325 | 0.39" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T23 | 000000 | 000000 | ||
Corrosion-Resistant Battery Wire
VFD Motor Cable
Power Wire— Stranded with PVC Outer Jacket
Power Wire | Inner Insulation | Per Ft. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | AWG | Cable AWG | Current @ Temp. | OD | Outer Jacket Color | Material | Color | Temp. Range, ° F | Cable Designation | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
Double Shielded—1,000V AC/1,500V DC | ||||||||||||||||
| 4 | 8 | 8/4 | 40 amp @ 86° F | 0.84" | Black | Nylon, PVC | Black, Green/Yellow | -40 to 220 | WTTC | UL Listed, C-UL Listed | 5, 10, 20, 30, 50, 100 | 7777T24 | 000000 | 000000 | ||
Flat Control Cable
Abrasion-Resistant Extension Cords
Light Duty Power Cords
Outer Jacket | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Voltage, V AC | Current, amp | AWG | Cable Designation | Material | Color | Certification | Each | |||
90° Elbow NEMA 10-50 Plug × Ring Terminal | |||||||||||
| 4 | 125/250 | 50 | 8, 6 | SRDT | PVC | Gray | UL Listed | 70355K114 | 000000 | ||
| 6 | 125/250 | 50 | 8, 6 | SRDT | PVC | Gray | UL Listed | 70355K37 | 00000 | ||
90° Elbow NEMA 14-50 Plug × Spade Terminal | |||||||||||
| 4 | 125/250 | 50 | 8, 6 | SRDT | PVC | Black | UL Listed | 70355K706 | 00000 | ||
| 6 | 125/250 | 50 | 8, 6 | SRDT | PVC | Black | UL Listed | 70355K94 | 00000 | ||