McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    38 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Lead Wire

    Also known as hook-up wire, this wire is primarily used for wiring electrical panels, lighting, and plant floor equipment. It meets UL 1007, UL 1015, or UL 1569 for appliance wiring.
    Stranded Wire—600V AC
    Image of Product. Front orientation. Stranded Wire. Lead Wire.
    Stranded wire is flexible, so it’s pliable enough to be pulled around corners. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM
    Style
    Choose an Outer Jacket Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    500 ft.
    Long
    26
    7/34
    5 amp @ 86° F0.08"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T210000000000000000000000000000
    24
    7/32
    7 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T2200000000000000000000000
    22
    7/30
    10 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Blue/White, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, Red/White, White, Yellow8054T2300000000000000000000000
    20
    10/30
    13 amp @ 86° F0.1"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Blue/White, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, Red/White, White, Yellow8054T2400000000000000000000000
    18
    16/30
    18 amp @ 86° F0.11"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Blue/White, Brown, Gray, Green, Green/Yellow, Orange, Pink, Purple, Red, Red/White, White, Yellow8054T25000000000000000000000000
    16
    26/30
    24 amp @ 86° F0.12"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T260000000000000000000000000
    14
    41/30
    33 amp @ 86° F0.14"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T2700000000000000000000000000
    12
    65/30
    45 amp @ 86° F0.16"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T28000000000000000000000000000
    10
    105/30
    58 amp @ 86° F0.18"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8054T290000000000000000000000000000
    Solid Wire—600V AC
    Image of Product. Front orientation. Solid Wire. Lead Wire.
    Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM
    Style
    Choose an Outer Jacket Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    24
    7 amp @ 86° F0.08"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Green, Orange, Red, White, Yellow8428T10000000000000000000000000000
    22
    10 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Green, Orange, Red, White, Yellow8428T200000000000000000000000
    20
    13 amp @ 86° F0.1"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Green, Orange, Red, White, Yellow8428T3000000000000000000000000
    18
    18 amp @ 86° F0.1"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Gray, Green, Green/Yellow, Orange, Purple, Red, White, Yellow8428T4000000000000000000000000
    16
    24 amp @ 86° F0.12"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Green, Orange, Red, White, Yellow8428T8000000000000000000000000000
    14
    33 amp @ 86° F0.13"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Green, Orange, Red, White, Yellow8428T7000000000000000000000000000
    12
    45 amp @ 86° F0.16"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Green, Orange, Red, White, Yellow8428T6000000000000000000000000000
    10
    58 amp @ 86° F0.18"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1015Black, Blue, Brown, Green, Orange, Red, White, Yellow8428T50000000000000000000000000000

    Machine Tool Wire

    More flexible than standard wire, this wire is often used for internal appliance wiring. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire. Also known as MTW wire, it’s rated UL 1063 for machine tool wiring.
    600V AC/600V DC
    Image of Product. Front orientation. Lead Wire. Machine Tool Wire.
    Metric wire is also known as Harmonized European Wire and meets HAR H07V-K for size (mm²), material, and voltage. It can also be used on North American electrical panels and machines.
    AWG
    Wire Strand
    Count
    Metric Wire
    Size, mm²
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Flexibility
    Cable
    Designation
    Specs.
    Met
    Certification
    AWM
    Style
    Choose an Outer
    Jacket Color
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    500 ft.
    Long
    Stranded Wire
    16
    30/0.26 mm²
    1.524 amp @ 86° F0.12"-40 to 220PVCFlexibleMTW
    UL 1063CSA Certified, HAR Marked H07V-K, UL Recognized Component
    1015Black, Blue, Green/Yellow6513T40000000000000000000000000000000
    14
    50/0.26 mm²
    2.535 amp @ 86° F0.15"-40 to 220PVCFlexibleMTW
    CSA Certified, HAR Marked H07V-K, UL Recognized Component
    1015Black, Blue, Green/Yellow6513T5000000000000000000000000000
    12
    56/0.31 mm²
    440 amp @ 86° F0.17"-40 to 220PVCFlexibleMTW
    CSA Certified, HAR Marked H07V-K, UL Recognized Component
    1015Black, Blue, Green/Yellow6513T60000000000000000000000000000
    10
    84/0.31 mm²
    655 amp @ 86° F0.19"-40 to 220PVCFlexibleMTW
    CSA Certified, HAR Marked H07V-K, UL Recognized Component
    1015Black, Green/Yellow6513T7000000000000000000000000000000
     

    Lead Wire Assortments

    Image of Product. Five Spools. Front orientation. 5. Lead Wire Assortments.
    Image of Product. Eight Spools. Front orientation. 8. Lead Wire Assortments.

    Five Spools

    Eight Spools

    Keep spools of wire in multiple colors on hand; each assortment includes one spool of each color listed. Mount the included rack (fasteners not included) or use it to transport wire. Also known as hook-up wire, it’s primarily used for wiring electrical panels, lighting, and plant for equipment. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Wire meets UL standards for appliance wiring.
    Stranded Wire—Stranded wire is flexible, so it’s pliable enough to be pulled around corners.
    Solid Wire—Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    Mount
    Holes
    25 ft. Long
    100 ft. Long
    No. of
    Spools
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Outer Jacket Color
    Certification
    Flammability
    Rating
    AWM Style
    No.
    of
    Dia.
    Each
    Each
    Stranded Wire
     
    600V AC
    526
    7/34
    5 amp @ 86° F0.08"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    101520.19"9948T340000009948T35000000
    524
    7/32
    7 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    101520.19"9948T36000009948T3700000
    522
    7/30
    10 amp @ 86° F0.1"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    101520.19"9948T38000009948T3900000
    520
    10/30
    13 amp @ 86° F0.1"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    101520.19"9948T4100000———0
    518
    16/30
    18 amp @ 86° F0.11"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    101520.19"9948T4200000———0
    516
    26/30
    24 amp @ 86° F0.12"-40 to 220PVCBlack, Blue, Green, Red, WhiteC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    101520.19"6616N2100000———0
    514
    41/30
    33 amp @ 86° F0.14"-40 to 220PVCBlack, Blue, Green, Red, WhiteC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    101520.19"6616N2200000———0
    512
    65/30
    45 amp @ 86° F0.16"-40 to 220PVCBlack, Blue, Green, Red, WhiteC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    101520.19"6616N23000000———0
    826
    7/34
    5 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    101520.19"6616N5100000———0
    824
    7/32
    7 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    101520.19"6616N5200000———0
    822
    7/30
    10 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    101520.19"6616N5300000———0
     
    Solid Wire
     
    600V AC
    518
    18 amp @ 86° F0.1"-40 to 220PVCBlack, Blue, Green, Red, WhiteCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015, 1032, 1230, 133520.19"9948T5100000———0
    824
    7 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015, 1032, 1230, 133520.19"9948T4800000———0
    822
    10 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015, 1032, 1230, 133520.19"9948T4900000———0
     
    back to top