About Wire and Cable
Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.
High-Voltage Continuous-Flex Lead Wire
Stranded Wire with Silicone Rubber Outer Jacket
Per Ft. | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | Temp. Range, ° F | OD | Outer Jacket Color | Performance | Environment | Clean Room Std. | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Unshielded | ||||||||||||||||
Tin-Plated Copper Wire—14,000V AC/10,000V DC | ||||||||||||||||
| 30 | 11/40 | 3 amp @ 86° F | -85 to 325 | 0.21" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T11 | 00000 | 00000 | ||
Tin-Plated Copper Wire—17,000V AC/12,000V DC | ||||||||||||||||
| 28 | 16/40 | 5 amp @ 86° F | -85 to 325 | 0.21" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T12 | 0000 | 0000 | ||
| 26 | 26/40 | 6 amp @ 86° F | -85 to 325 | 0.22" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T13 | 0000 | 0000 | ||
| 24 | 42/40 | 7 amp @ 86° F | -85 to 325 | 0.22" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T14 | 0000 | 0000 | ||
Tin-Plated Copper Wire—44,000V AC/31,000V DC | ||||||||||||||||
| 22 | 66/40 | 8 amp @ 86° F | -85 to 325 | 0.23" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T15 | 0000 | 0000 | ||
| 20 | 105/40 | 10 amp @ 86° F | -85 to 325 | 0.24" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T16 | 0000 | 0000 | ||
Tin-Plated Copper Wire—59,000V AC/42,000V DC | ||||||||||||||||
| 18 | 168/40 | 15 amp @ 86° F | -85 to 325 | 0.25" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T17 | 0000 | 0000 | ||
| 16 | 280/40 | 19 amp @ 86° F | -85 to 325 | 0.26" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T18 | 0000 | 0000 | ||
| 14 | 441/40 | 27 amp @ 86° F | -85 to 325 | 0.28" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T19 | 00000 | 00000 | ||
| 12 | 672/40 | 36 amp @ 86° F | -85 to 325 | 0.3" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T21 | 00000 | 00000 | ||
| 10 | 780/40 | 47 amp @ 86° F | -85 to 325 | 0.33" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T22 | 00000 | 00000 | ||
| 8 | 1,666/40 | 65 amp @ 86° F | -85 to 325 | 0.39" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T23 | 00000 | 00000 | ||
| 6 | 2,744/40 | 95 amp @ 86° F | -85 to 325 | 0.44" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T24 | 00000 | 00000 | ||
| 4 | 1,666/36 | 125 amp @ 86° F | -85 to 325 | 0.5" | Clear | Flame Retardant, High Voltage, Low Smoke, Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | CSA Certified, UL Recognized Component | UL 94 V-0 | 5, 10, 25, 50, 100 | 9620T25 | 00000 | 00000 | ||