    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    High-Voltage Continuous-Flex Lead Wire

    A thick insulation protects this wire from high voltages while maintaining flexibility. The insulation also resists moisture. Often used in automated applications such as robotics, it withstands continuous motion without degrading data or signal transmission. It meets UL 94 V-0 for flame retardance. If this wire is exposed to flames, it minimizes how much smoke and halogen it releases.
    Stranded Wire with Silicone Rubber Outer Jacket
    Image of Product. Front orientation. Lead Wire. High-Voltage Continuous-Flex Lead Wire.
    Per Ft.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    Temp. Range,
    ° F
    OD
    Outer Jacket
    Color
    Performance
    Environment
    Clean Room Std.
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Unshielded
     
    Tin-Plated Copper Wire—14,000V AC/10,000V DC
    30
    11/40
    3 amp @ 86° F-85 to 3250.21"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T110000000000
     
    Tin-Plated Copper Wire—17,000V AC/12,000V DC
    28
    16/40
    5 amp @ 86° F-85 to 3250.21"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T1200000000
    26
    26/40
    6 amp @ 86° F-85 to 3250.22"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T1300000000
    24
    42/40
    7 amp @ 86° F-85 to 3250.22"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T1400000000
     
    Tin-Plated Copper Wire—44,000V AC/31,000V DC
    22
    66/40
    8 amp @ 86° F-85 to 3250.23"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T1500000000
    20
    105/40
    10 amp @ 86° F-85 to 3250.24"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T1600000000
     
    Tin-Plated Copper Wire—59,000V AC/42,000V DC
    18
    168/40
    15 amp @ 86° F-85 to 3250.25"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T1700000000
    16
    280/40
    19 amp @ 86° F-85 to 3250.26"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T1800000000
    14
    441/40
    27 amp @ 86° F-85 to 3250.28"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T190000000000
    12
    672/40
    36 amp @ 86° F-85 to 3250.3"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T210000000000
    10
    780/40
    47 amp @ 86° F-85 to 3250.33"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T220000000000
    8
    1,666/40
    65 amp @ 86° F-85 to 3250.39"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T230000000000
    6
    2,744/40
    95 amp @ 86° F-85 to 3250.44"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T240000000000
    4
    1,666/36125 amp @ 86° F-85 to 3250.5"ClearFlame Retardant, High Voltage, Low Smoke, Zero HalogenClean Room
    Fed. Std. Class 1, ISO Class 3
    CSA Certified, UL Recognized Component
    UL 94 V-0
    5, 10, 25, 50, 1009620T250000000000
     