McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    81 Products

    High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. High-Current Time and Day Activated Switches.
    Control equipment with high currents such as landscape lighting, pumps, and heaters. Program these switches to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Trippers—Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
    Switches
    Trippers
    No. of Circuits
    Controlled
    Switching Current @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time
    Tripper
    Type
    No. of
    Trippers
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Environment
    Each
    No. of Trippers
    Included
    Pkg.
    24-Hr. Timing Cycle
    120 amp @ 120V AC, 208V AC, 240V AC, 277V AC120/208/240/2774815 min.Captive96SPDT
    7 3/4"5"3"Screw TerminalIndoor Only00000000000000———0
    140 amp @ 240V AC120121 hr.Removable2SPST
    7 3/4"5"3"Screw TerminalIndoor Only0000000000001 Pair000000000000
    240 amp @ 240V AC120121 hr.Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only0000000000001 Pair00000000000
    240 amp @ 240V AC208/240/277121 hr.Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only00000000000001 Pair00000000000
     
    24-Hr. Timing Cycle with Day Skipper and Three Skip Screws
    140 amp @ 240V AC120101 hr.Removable2SPST
    7 3/4"5"3"Screw TerminalIndoor Only0000000000001 Pair00000000000
    240 amp @ 240V AC120101 hr.Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only00000000000001 Pair00000000000
    240 amp @ 240V AC208/240/277101 hr.Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only00000000000001 Pair00000000000
     
    7-Day Timing Cycle
    120 amp @ 240V AC120122 hr.Captive84SPDT
    7 3/4"5"3"Screw TerminalIndoor Only00000000000000———0
    440 amp @ 240V AC12033.5 hr.Removable44PST-NO
    12 1/2"8 1/4"4"Screw TerminalIndoor Only000000000000007 Pair0000000000000
     
    Screws

    Panel-Mount Timer Switches

    Image of Product. 15 amp Switching Current. Front orientation. Timer Switches. Panel-Mount Timer Switches, 1 Circuit Controlled, 15 amp Switching Current.
    Image of Product. 20 amp Switching Current. Front orientation. Timer Switches. Panel-Mount Timer Switches, 1 Circuit Controlled, 20 amp Switching Current.

    15 amp Switching

    Current

    20 amp Switching

    Current

    Install these switches in a panel cutout to automatically turn electrical equipment on or off after a set interval.
    Set Time Recall—Switches with set time recall retain the last setting; push the button to start the timer over at the same interval, eliminating the need to reset the dial with every use.
    Wire
    Leads
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switching Current
    @ Voltage
    Set Time
    Input Voltage,
    V AC
    Dia.
    Dp.
    For Panel
    Cutout Dia.
    For Max.
    Panel Thk.
    Wire Connection
    No. of
    Terminals
    No.
    of
    Lg.
    Each
    Dial Reset
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 min. to 30 min.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"00000000000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 hr. to 12 hr.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"0000000000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 hr. to 60 hr.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"0000000000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC2 hr. to 24 hr.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"0000000000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC5 min. to 60 min.1203 1/16"1 13/16"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"0000000000000
    11 Off or 1 On
    20 amp @ 120V AC/240V AC1 min. to 15 min.120/2402 9/16"1 9/16"13/32"1/8"Screw Terminal30000000000000
    11 Off or 1 On
    20 amp @ 120V AC/240V AC1 min. to 30 min.120/2402 3/4"1 5/8"2 19/32"1/4"Screw Terminal30000000000000
     
    Push Reset with Set Time Recall
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 min. to 30 min.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"0000000000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 hr. to 12 hr.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"0000000000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC1 hr. to 60 hr.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"0000000000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC2 hr. to 24 hr.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"0000000000000
    11 Off or 1 On
    15 amp @ 125V AC/250V AC5 min. to 60 min.1203 1/16"2 1/8"3/8"1/8"Quick-Disconnect Terminal/Wire Leads228"0000000000000
     
    Replacement Actuators

    Outdoor High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Trippers—Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
    Switches
    Trippers
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time
    Tripper
    Type
    No. of
    Trippers
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Each
    No. of Trippers
    Included
    Pkg.
    24-Hr. Timing Cycle
    140 amp @ 240V AC120121 hr.Removable2SteelSPST
    9 3/8"5 1/2"3 5/8"Screw Terminal000000000000001 Pair000000000000
    240 amp @ 240V AC120/208/240/2774815 min.Captive96Polycarbonate
    DPDT
    8 7/8"6 5/8"3"Screw Terminal000000000000———0
    240 amp @ 240V AC120121 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal00000000000001 Pair00000000000
    240 amp @ 240V AC208/240/277121 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal00000000000001 Pair00000000000
     
    24-Hr. Timing Cycle with Day Skipper and Three Skip Screws
    240 amp @ 240V AC120101 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal00000000000001 Pair00000000000
    240 amp @ 240V AC208/240/277101 hr.Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal00000000000001 Pair00000000000
     
    7-Day Timing Cycle
    240 amp @ 240V AC120/208/240/27762 hr.Captive96Polycarbonate
    DPDT
    8 7/8"6 5/8"3"Screw Terminal00000000000000———0
    440 amp @ 240V AC12033.5 hr.Removable14Steel4PST
    12 1/2"8 1/4"4"Screw Terminal000000000000007 Pair0000000000000
     
    Screws

    Panel-Mount Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Panel-Mount Time and Day Activated Switches.
    Install these switches in a panel cutout and program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. As UL and C-UL Recognized Components that are also CE Marked, these switches meet American, Canadian, and European safety standards.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week. They come with an override to bypass their programmed settings.
    For Panel
    Cutout
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage,
    V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time
    Timing Adjustment
    Style
    Tripper
    Type
    With
    Override
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Wire Connection
    Certification
    Each
    24-Hr. Timing Cycle
    121 amp @ 250V AC1204815 min.TripperCaptiveSPDT
    2.8"2.8"1.5"2.63"2.63"Quick-Disconnect TerminalUL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked
    0000000000000
     
    7-Day Timing Cycle
    121 amp @ 250V AC12062 hr.TripperCaptiveYesSPDT
    2.8"2.8"1.5"2.63"2.63"Quick-Disconnect TerminalUL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked
    0000000000000
     

    Surface/DIN-Rail Mount Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Surface/DIN-Rail Mount Time and Day Activated Switches.
    Mount these switches to a flat surface or attach to DIN rail. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times. These switches have a 24-hr. timing cycle that repeats the same program daily. As UL and C-UL Recognized Components that are also CSA Certified and CE Marked, they meet American, Canadian, and European safety standards.
    Mounting
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage,
    V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Tripper
    Type
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    For DIN
    Rail Ht., mm
    Wire
    Connection
    Certification
    Each
    24-Hr. Timing Cycle
    121 amp @ 250V AC1204815TripperCaptiveSPDT
    4.2"2.8"2.2"No30.13"35Screw TerminalUL Recognized Component, C-UL Recognized Component, CSA Certified, CE Marked
    0000000000000
     

    Energy-Saving Panel-Mount Timer Switches

    Image of Product. Front orientation. Timer Switches. Energy-Saving Panel-Mount Timer Switches.
    Push and release the button to activate—no electricity required.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switching Current
    @ Voltage
    Set Time
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    No. of
    Terminals
    Dp. Behind
    Panel
    For Panel
    Cutout Dia.
    For Max.
    Panel Thk.
    Each
    11 Off or 1 On
    10 amp @ 120V AC/240V AC2 sec. to 1 min.1 7/16"1"1 1/2"Tab Terminal41 1/16"15/32"3/16"00000000000000

    Wall-Mount Timer Switches

    Use these switches in place of standard wall switches to automatically turn electrical equipment on or off after a set interval of time. They’re often used with lights.
    Knob
    Image of Product. Front orientation. Timer Switches. Wall-Mount Timer Switches, Knob.
    With Override—Switches with override can bypass the automatic shut-off.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switching Current @ Voltage
    Set Time
    For Outlet Box
    Designation
    Wire
    Connection
    Choose a Knob
    Color
    Each
    Without Override
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC40 sec. to 5 min.1 Gang
    Screw Terminal
    Ivory
    ,
    White
    0000000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC1 min. to 30 min.1 Gang
    Screw Terminal
    Ivory
    ,
    White
    000000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC10 min. to 60 min.1 Gang
    Screw Terminal
    Ivory
    ,
    White
    000000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC1 hr. to 6 hr.1 Gang
    Screw Terminal
    Ivory
    ,
    White
    000000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC2 hr. to 12 hr.1 Gang
    Screw Terminal
    Ivory
    ,
    White
    000000000000
     
    With Override
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC1 min. to 30 min.1 Gang
    Screw Terminal
    Ivory
    ,
    White
    000000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC10 min. to 60 min.1 Gang
    Screw Terminal
    Ivory
    ,
    White
    000000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC1 hr. to 6 hr.1 Gang
    Screw Terminal
    Ivory
    ,
    White
    000000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC2 hr. to 12 hr.1 Gang
    Screw Terminal
    Ivory
    ,
    White
    000000000000
     
    Replacement Actuators
    Knob and Silver Plastic Wall Plate
    Image of Product. Front orientation. Timer Switches. Wall-Mount Timer Switches, Knob and Silver Plastic Wall Plate.
    With Override—Switches with override can bypass the automatic shut-off.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switching Current @ Voltage
    Set Time
    For Outlet Box
    Designation
    Wire
    Connection
    Knob
    Color
    Each
    Without Override
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC1 min. to 5 min.1 Gang
    Screw TerminalIvory000000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC4 min. to 30 min.1 Gang
    Screw TerminalIvory00000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC10 min. to 60 min.1 Gang
    Screw TerminalIvory00000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC1 hr. to 6 hr.1 Gang
    Screw TerminalIvory00000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC2 hr. to 12 hr.1 Gang
    Screw TerminalIvory000000000000
     
    With Override
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC1 min. to 5 min.1 Gang
    Screw TerminalIvory00000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC4 min. to 30 min.1 Gang
    Screw TerminalIvory00000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC10 min. to 60 min.1 Gang
    Screw TerminalIvory00000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC1 hr. to 6 hr.1 Gang
    Screw TerminalIvory00000000000
    11 Off
    20 amp @ 125V AC, 10 amp @ 250V AC2 hr. to 12 hr.1 Gang
    Screw TerminalIvory00000000000
     
    Replacement Actuators

    Smart Time and Day Activated Switches

    Image of ProductInUse. Front orientation. Contains MultipleImages. Timer Switches. Smart Time and Day Activated Switches.
    Use your smart phone to turn equipment on and off at a set time and day. These switches connect to your phone via NFC (near field communication) and work with a free app to set schedules, adjust settings, and save programs. They can perform a different program each day of the week, and they compensate for leap year and daylight savings time. You can remotely apply programs across compatible switches, so it’s easy to reprogram lighting or equipment in large facilities. These switches mount to a flat surface or attach to DIN rail.
    Astronomical Timing—Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage
    Max. On/Off
    Cycles, per wk.
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Electrical
    Connection
    Operating System Compatibility
    For DIN
    Rail Ht., mm
    Wire
    Connection
    Certification
    Each
    7-Day Timing Cycle
    116 amp @ 240V AC120V AC/208V AC/240V AC/120V DC/240V DC501JoystickSPDT
    3.4"1.4"2.2"NFCAndroid 5.1 or Later, iOS 13.1 or Later35Screw TerminalUL Listed, C-UL Listed, CE Marked
    000000000000000
    216 amp @ 240V AC120V AC/208V AC/240V AC/120V DC/240V DC501JoystickDPDT
    3.4"1.4"2.2"NFCAndroid 5.1 or Later, iOS 13.1 or Later35Screw TerminalUL Listed, C-UL Listed, CE Marked
    00000000000000
     
    7-Day Timing Cycle—With Astronomical Timing
    116 amp @ 240V AC120V AC/208V AC/240V AC/120V DC/240V DC501JoystickSPDT
    3.4"1.4"2.2"NFCAndroid 5.1 or Later, iOS 13.1 or Later35Screw TerminalUL Listed, C-UL Listed, CE Marked
    00000000000000
    216 amp @ 240V AC120V AC/208V AC/240V AC/120V DC/240V DC501JoystickDPDT
    3.4"1.4"2.2"NFCAndroid 5.1 or Later, iOS 13.1 or Later35Screw TerminalUL Listed, C-UL Listed, CE Marked
    00000000000000
     

    High-Current Wall-Mount Timer Switches

    Image of Product. Front orientation. Timer Switches. High-Current Wall-Mount Timer Switches.
    Control equipment with high currents such as air conditioners, heaters, and ventilating equipment. They automatically turn electrical equipment on or off after a set interval of time.
    With Override—Switches with override can bypass the automatic shut-off.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switching Current
    @ Voltage
    hp @ Switching Voltage
    Set Time
    For Outlet Box
    Designation
    Includes
    Wire
    Connection
    Each
    Without Override
    11 Off or 1 On
    28 amp @ 120V AC/240V AC1 hp @ 120V AC, 1 hp @ 240V AC1 min. to 1 hr.2 Gang
    Steel Wall PlateScrew Terminal00000000000000
    11 Off or 1 On
    28 amp @ 120V AC/240V AC1 hp @ 120V AC, 1 hp @ 240V AC15 min. to 12 hr.2 Gang
    Steel Wall PlateScrew Terminal0000000000000
    21 Off
    28 amp @ 120V AC/240V AC1 hp @ 120V AC, 1 hp @ 240V AC1 min. to 1 hr.2 Gang
    Steel Wall PlateScrew Terminal0000000000000
    21 Off
    28 amp @ 120V AC/240V AC1 hp @ 120V AC, 1 hp @ 240V AC15 min. to 12 hr.2 Gang
    Steel Wall PlateScrew Terminal0000000000000
     
    With Override
    11 Off or 1 On
    28 amp @ 120V AC/240V AC1 hp @ 120V AC, 1 hp @ 240V AC1 min. to 1 hr.2 Gang
    Steel Wall PlateScrew Terminal0000000000000
    11 Off or 1 On
    28 amp @ 120V AC/240V AC1 hp @ 120V AC, 1 hp @ 240V AC15 min. to 12 hr.2 Gang
    Steel Wall PlateScrew Terminal0000000000000
    21 Off
    28 amp @ 120V AC/240V AC1 hp @ 120V AC, 1 hp @ 240V AC1 min. to 1 hr.2 Gang
    Steel Wall PlateScrew Terminal0000000000000
    21 Off
    28 amp @ 120V AC/240V AC1 hp @ 120V AC, 1 hp @ 240V AC15 min. to 12 hr.2 Gang
    Steel Wall PlateScrew Terminal0000000000000
     
    Replacement Actuators

    Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Time and Day Activated Switches, 24-Hr. Timing Cycle.

    24-Hr. Timing Cycle

    Program these switches to turn a device on and off at a set time and day. They have a three-prong outlet to plug devices directly into the switch. Use with lamps and other small electrical loads. All have an override to bypass the programmed on/off settings.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    Timing-Adjustment Tripper—Switches with trippers are programmed by setting on and off times by positioning trippers around the clock dial.
    Electrical
    Switching Current
    @ Voltage
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Tripper
    Type
    No. of
    Trippers
    With
    Override
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Connection
    No. of
    Blades
    Certification
    Each
    24-Hr. Timing Cycle
    15 amp @ 120V AC330TripperRemovable6Yes13 1/4"3 1/4"3 1/4"Straight Blade3CSA-US Certified, CSA Certified
    0000000000000
     

    Timer Switches

    Image of Product. Front orientation. Timer Switches. Timer Switches.
    Automatically turn electrical equipment off after a set interval of time. Use the three-prong outlet to plug a device directly into the switch.
    Switching Current
    @ Voltage
    Set Time,
    min.
    No. of
    Outlets
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Each
    10 amp @ 125V AC0 to 30163 1/4"2 3/4"2 3/4"00000000000000

    Handheld IO Link Programmers

    Image of Product. Front orientation. IO Link Programmers. Handheld IO Link Programmers.
    Image of Specification. 3-Pole Nano M8. Front orientation. Handheld IO Link Programmers, A Code, 3-Pole Electrical Socket, Plug In.

    3-Pole

    Nano M8

    Image of Specification. 4-Pole Nano M8. Front orientation. A Code. Handheld IO Link Programmers, Nano M8, 4-Pole Electrical Socket, Plug In.

    4-Pole

    Nano M8

    Image of Specification. 5-Pole Micro M12. Front orientation. 5-Pole Electrical Socket. Handheld IO Link Programmers, A Code, Micro M12, Plug In.

    5-Pole

    Micro

    M12

    Configure any of your IO Link devices—from sensors to switches—without a PC, outlet, or separate software. Use these programmers to set parameters, check the quality of runs, clone settings for other devices, and more. Whether you’re setting up a device for the first time or adjusting settings, the easy-to-use touchscreen makes for a smooth experience. Since these programmers are powered by a battery and small enough to carry, you can bring them wherever you need.
    As soon as you connect your device, these programmers download its IO Device Description (IODD) file. This means you won’t need to manually input device details, saving you time to jump right into programming. Internal storage keeps IODD files and custom settings on hand for you. If you need extra space, insert a microSD card (not included) into these programmers before turning on the connected device.
    Plug devices with M8 or M12 connections directly into the sockets on these programmers. If your device has wire leads, use the included adapter.
    Connection Type
    Internal Memory
    Size, GB
    Data Connection
    Features
    Enclosure
    Rating
    Battery
    Type
    Includes
    Certification
    Each
    A-Code, 3-Pole Nano M8 Plug In
    A-Code, 4 -Pole Nano M8 Plug In
    A-Code, 5-Pole Micro M12 Plug In
    16Wi-Fi
    microSD Card
    LED Status IndicatorIP30
    RechargeableM12 to 4 Hook Adapter (1 1/2 ft. Lg)
    USB Charging Cord (1 1/2 ft. Lg)
    CE Marked
    0000000000000000

    Outlet-Box-Mount Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outlet-Box-Mount Time and Day Activated Switches, 24-Hr. Timing Cycle.

    24-Hr.

    Timing

    Cycle

    Switches fit 1 gang outlet boxes. Program them to turn a device on and off at a set time and day. They’re often used with lamps and other small electrical loads.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Tripper
    Type
    Switch
    Designation
    For Outlet Box
    Designation
    Wire
    Connection
    Wire Lead
    Lg.
    Certification
    Each
    24-Hr. Timing Cycle—With On/Off/Timer Selector
    120 amp @ 120V AC2430TripperCaptiveSPST
    1 Gang
    Wire Leads6"UL Listed, C-UL Listed
    000000000000
     

    High-Visibility Timer Switches

    Image of Product. Front orientation. Timer Switches. High-Visibility Timer Switches, With White Face.
    Image of Product. Front orientation. Timer Switches. High-Visibility Timer Switches, With Black Face and Glow-in the-Dark Dial and Hands.

    With White Face

    With Black Face and Glow-in

    the-Dark Dial and Hands

    The large face makes these switches easy to read from a distance. They automatically turn electrical equipment on or off after a set interval of time. All have two three-prong outlets to control up to two devices at once; plug each device directly into the switch. A rocker switch controls the outlet settings. The buzzer sounds when the timer stops.
    With White Face—Switches with a white face can be set so that both outlets turn off when the timer stops, or so that the top outlet turns off and the bottom outlet turns on.
    With Black Face and Glow-in the-Dark Dial and Hands—Switches with a black face can be set so that both outlets turn on when the timer stops, or so that the top outlet remains off and the bottom outlet remains on.
    Outlet
    Electrical
    Mounting
    Switching Current
    @ Voltage
    hp @ Switching
    Voltage
    Set Time
    Face
    Dia.
    No.
    of
    Type
    Switch
    Style
    Cord Lg.,
    ft.
    Connection
    No. of
    Blades
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    With White Face
    5 amp @ 120V AC1/3 hp @ 120V AC0.25 sec. to 15 min.6 1/2"2Three ProngRocker6Straight Blade37 1/2"7 1/2"2 1/2"No23/8"00000000000000
    5 amp @ 120V AC1/3 hp @ 120V AC1 sec. to 60 min.6 1/2"2Three ProngRocker6Straight Blade37 1/2"7 1/2"2 1/2"No23/8"0000000000000
    5 amp @ 120V AC1/3 hp @ 120V AC1 min. to 60 hr.6 1/2"2Three ProngRocker6Straight Blade37 1/2"7 1/2"2 1/2"No23/8"0000000000000
    5 amp @ 120V AC1/3 hp @ 120V AC15 sec. to 15 hr.6 1/2"2Three ProngRocker6Straight Blade37 1/2"7 1/2"2 1/2"No23/8"0000000000000
     
    With Black Face and Glow-in the-Dark Dial and Hands
    5 amp @ 120V AC1/3 hp @ 120V AC1 sec. to 60 min.6 1/2"2Three ProngRocker6Straight Blade37 1/2"7 1/2"2 1/2"No23/8"0000000000000
     
    back to top