Hazardous Location Enclosures
For use in hazardous locations, these enclosures are rated NEMA 7 and 9 and meet UL Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2. They are also rated NEMA 4 for protection from dirt and washdowns.
Panels are for mounting components inside enclosures.
For technical drawings and 3-D models, click on a part number.
Enclosures | Panels | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Wall Thick. | Environment | Environmental Rating | Specifications Met | Each | Each | ||
Aluminum with Lift-Off Cover and Screw Closure | ||||||||||
10 1/4" | 10 1/4" | 6" | 1/2" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 000000000 | 0000000 | 0000000 |
12 1/4" | 12 1/4" | 8" | 1/2" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 00000000 | 0000000 | 000000 |
12 1/4" | 14 1/4" | 8 1/4" | 1/2" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 00000000 | 0000000 | 000000 |
Aluminum with Hinged Cover and Screw Closure | ||||||||||
16 1/2" | 16 1/2" | 8 3/4" | 3/4" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 00000000 | 0000000 | 000000 |
16 1/2" | 16 1/2" | 10 3/4" | 3/4" | Hazardous Location, Washdown | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA IP66 NEMA 4 NEMA 7 NEMA 9 | UL Listed, UL 698, UL 886, UL 1203, CSA Certified | 0000000 | 00000000 | 0000000 | 000000 |
Push-Button Hazardous Location Enclosures
UL and C-UL classified, these enclosures safely house push-button controls and electronics where there’s explosive dust and gas. They have holes already drilled to standard button sizes and conduit connections that let you route wire through the enclosure, saving you effort and time. NEMA rated, they also protect what’s inside from dust, rain, and spraying water.
For technical drawings and 3-D models, click on a part number.
Inside | Connection | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Columns | Number of Rows | Height | Width | Depth | Height | Width | Depth | Environment | Thread Type | Pipe Size | Features | Specifications Met | Color | Each | |
Aluminum with Lift-Off Cover and Screw Closure | |||||||||||||||
For 19 mm Push Button | |||||||||||||||
1 | 1 | 4 1/2" | 4 1/2" | 4 3/8" | 3" | 3" | 3 7/8" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 3/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 0000000 |
1 | 2 | 7 1/16" | 4 1/2" | 4 3/16" | 6" | 3" | 3 3/4" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 3/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 3 | 8 1/8" | 4 1/2" | 4 3/16" | 7" | 3" | 3 11/16" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 3/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 4 | 10 1/16" | 4 1/2" | 4 1/4" | 9" | 3" | 3 3/4" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 1 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 5 | 12 1/16" | 4 1/2" | 4 1/4" | 11" | 3" | 3 3/4" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 1 1/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 6 | 14 1/16" | 4 1/2" | 4 1/8" | 13" | 3" | 3 5/8" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 1 1/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
1 | 7 | 16" | 4 1/2" | 4 1/8" | 15" | 3" | 3 5/8" | Corrosive, Damp, Dusty, Hazardous Location, Outdoor, Washdown | NPT | 1 1/4 | Grounding Stud; Mounting Feet | UL Classified, C-UL Classified | Gray | 0000000 | 000000 |
Hazardous Location Inspection Windows for Enclosures
Safely and clearly view electronics inside enclosures in areas with explosive gases and dust. Made of glass, these windows protect your electronics from dust, weather, and washdowns. All have a 316 stainless steel frame that resists corrosion.
For technical drawings and 3-D models, click on a part number.
Overall | For Opening | Window | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Height | Width | Frame Thickness | Height | Width | Viewing Height | Viewing Width | Gasket Material | For Wall Thickness Range | For Use Outdoors | Mounting Hardware Included | Features | Environmental Rating | Specifications Met | Each | |
316 Stainless Steel Frame | |||||||||||||||
7 1/2" | 5 1/2" | 5/16" | 6 11/16" | 4 11/16" | 5" | 3" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 0000000 |
9 1/2" | 13" | 5/16" | 8 11/16" | 12 11/16" | 7" | 11" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 000000 |
9 1/2" | 17 1/2" | 5/16" | 8 11/16" | 16 11/16" | 7" | 15" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 00000000 |
9 1/2" | 22 1/2" | 5/16" | 8 11/16" | 21 11/16" | 7" | 20" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 00000000 |
9 1/2" | 26 1/2" | 5/16" | 8 11/16" | 25 11/16" | 7" | 24" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 00000000 |
9 1/2" | 31 1/2" | 5/16" | 8 11/16" | 30 11/16" | 7" | 29" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 00000000 |
11 1/2" | 8" | 5/16" | 10 11/16" | 7 3/16" | 9" | 5 1/2" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 000000 |
15 1/2" | 10 1/2" | 5/16" | 14 11/16" | 9 11/16" | 13" | 8" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 00000000 |
19 1/2" | 13 1/2" | 5/16" | 18 11/16" | 12 11/16" | 17" | 11" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 00000000 |
25 1/2" | 17 1/2" | 5/16" | 24 11/16" | 16 11/16" | 23" | 15" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 00000000 |
31 1/2" | 21 1/2" | 5/16" | 30 11/16" | 20 11/16" | 29" | 19" | Silicone Rubber | 1/16"-1/8" | Yes | Yes | Grounding Stud | IP66, NEMA 13, NEMA 4X | IECEx Ex e IIC Gb, ATEX Ex e IIC Gb, C-UL Recognized Component, IECEx Ex tb IIIC Db, UL Recognized Component, ATEX Ex tb IIIC Db | 0000000 | 00000000 |
Hazardous Location Telephones
For use in hazardous locations, these phones meet UL and CSA specifications for Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; and Class III, Div. 2. They have a sealed keypad to keep out dirt and moisture and are made from glass-filled polyester to withstand corrosion and extreme temperatures.
Optional text telephone adapters make it easier for people who are deaf, hard of hearing, or speech-impaired to use these phones to communicate, by letting them send and receive typed messages. They’re also known as TTY, TDD, and teletypewriters.
With Retractable Plastic Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Lines | Ht. | Wd. | Dp. | Color | Cord Lg. | Environmental Rating | Specifications Met | Features | Each | |
1 | 13 1/4" | 9 3/8" | 7 3/8" | Blue | 72" | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 NEMA 3R | UL Listed, UL 508, CSA Certified | Volume Control, Background Noise Canceling Device, Sealed Keypad | 0000000 | 000000000 |