    Belt-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans with Louvers .
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    30"6,00055 dB @ 5 ft.Belt55011/237"37"36 1/2"36 1/2"19"152104SteelSteelSteelNo3/16"0000000000000000
    36"8,10053 dB @ 5 ft.Belt40011/243"43"42 1/2"42 1/2"19"121104SteelSteelSteelNo3/16"000000000000000
    42"11,00057 dB @ 5 ft.Belt40013/449"49"48 1/2"48 1/2"19"270104SteelSteelSteelNo3/16"000000000000000
    48"14,90057 dB @ 5 ft.Belt3501155"55"54 1/2"54 1/2"19"266104SteelSteelSteelNo3/16"000000000000000
    Replacements for Exhaust Fans
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    30"6,00055 dB @ 5 ft.Belt55011/237"37"36 1/2"36 1/2"25"153104SteelSteelSteelNo3/16"0000000000000000
    36"8,10053 dB @ 5 ft.Belt40011/243"43"42 1/2"42 1/2"25"225104SteelSteelSteelNo3/16"000000000000000
    42"11,00057 dB @ 5 ft.Belt40013/449"49"48 1/2"48 1/2"25"250104SteelSteelSteelNo3/16"000000000000000
    48"14,90057 dB @ 5 ft.Belt3501155"55"54 1/2"54 1/2"25"324104SteelSteelSteelNo3/16"000000000000000
    Replacements for Exhaust Fans

    Belt-Drive Wall-Mount Exhaust Fans

    Use these fans to draw stagnant and humid air out of a room or area. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Back orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans .
    Image of Product. Front orientation. Exhaust Fan Collars. Belt-Drive Wall-Mount Exhaust Fans .

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    30"8,20056 dB @ 5 ft.Belt60011/236"36"18 3/8"SteelSteel0000000000000000000000000000
    36"10,60056 dB @ 5 ft.Belt42511/242"42"18 5/8"SteelSteel0000000000000000000000000000
    48"18,50061 dB @ 5 ft.Belt4001154"54"24 3/4"SteelSteel0000000000000000000000000000
    Replacements for Exhaust Fans
    230/460V AC, Three Phase—Hardwire
    Image of Product. Back orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans .
    Image of Product. Front orientation. Exhaust Fan Collars. Belt-Drive Wall-Mount Exhaust Fans .

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    30"8,20056 dB @ 5 ft.Belt60011/236"36"18 3/8"SteelSteel0000000000000000000000000000
    36"10,60056 dB @ 5 ft.Belt42511/242"42"18 5/8"SteelSteel00000000000000000000000000
    48"18,50056 dB @ 5 ft.Belt4001154"54"24 3/4"SteelSteel0000000000000000000000000000
    Replacements for Exhaust Fans

    Belt-Drive Downdraft Roof-Mount Exhaust Fans

    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    120V AC/208 to 230V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Downdraft Roof-Mount Exhaust Fans .
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Housing
    Material
    Blade
    Material
    Features
    Each
    Each
    16"2,800 ft³/min @ 1/2 in. H₂O
    3,200 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.Belt1,14513/433 11/16"29 1/4"26"Aluminum
    Aluminum
    Bird Screen000000000000000000000000000000
    20"4,900 ft³/min @ 1/2 in. H₂O
    5,400 ft³/min @ 0 in. H₂O
    74 dBA @ 5 ft.Belt1,08011 1/238 1/4"31 3/4"30"Aluminum
    Aluminum
    Bird Screen0000000000000000000000000000
    208 to 230V AC/460V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Downdraft Roof-Mount Exhaust Fans .
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Housing
    Material
    Blade
    Material
    Features
    Each
    Each
    24"6,900 ft³/min @ 1/2 in. H₂O
    7,750 ft³/min @ 0 in. H₂O
    73 dBA @ 5 ft.Belt8751244 1/4"39 11/16"33"Aluminum
    Aluminum
    Bird Screen000000000000000000000000000000

    Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.
    Image of Product. Front orientation. Exhaust Fan Collars. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    36"14,20068 dB @ 5 ft.Belt80011 1/242"42"19 1/8"SteelSteel000000000000000000000000000000
    48"26,80072 dB @ 5 ft.Belt6001354"54"24 7/8"SteelSteel0000000000000000000000000000
    54"37,60070 dB @ 5 ft.Belt5251560"60"23 1/2"SteelSteel0000000000000000000000000000
    60"50,00079 dB @ 5 ft.Belt50017 1/266"66"23 1/2"SteelSteel0000000000000000000000000000

    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Belt Drive—Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged. They come with collars, so you can connect these fans to a louver.
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Includes
    Each
    30"9,84071 dBA @ 10 ft.Belt1,72513/434 3/4"34 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar0000000000000000
    36"11,00072 dBA @ 10 ft.Belt1,72513/440 3/4"40 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar000000000000000
    42"14,60074 dBA @ 10 ft.Belt1,72513/446 3/4"46 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar000000000000000
    48"19,10070 dBA @ 10 ft.Belt1,72513/452 3/4"52 3/4"30"SteelAluminum
    UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    Collar000000000000000

    Hazardous Location Upblast Roof-Mount Exhaust Fans

    With a UL-listed motor, these fans can be used in hazardous environments with combustible gases and dust to draw stagnant and humid air out through your roof, forcing it up and away from its surface.
    Belt Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    120/240V AC, Single Phase—Hardwire
    24"3,530 ft³/min @ 1/2 in. H₂O
    6,150 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.1,7503/433"25"36"340100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    000000000000000000000000000000
    30"2,950 ft³/min @ 1/2 in. H₂O
    9,800 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,7503/439"28"42"410100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
     
    240/460V AC, Three Phase—Hardwire
    36"20,200 ft³/min @ 1/2 in. H₂O
    24,100 ft³/min @ 0 in. H₂O
    82 dBA @ 5 ft.1,750545"31"48"590100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
    42"22,400 ft³/min @ 1/2 in. H₂O
    27,800 ft³/min @ 0 in. H₂O
    78 dBA @ 5 ft.1,750551"34"54"720100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
    48"28,600 ft³/min @ 1/2 in. H₂O
    36,700 ft³/min @ 0 in. H₂O
    80 dBA @ 5 ft.1,750557"37"60"840100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    0000000000000000000000000000
     

    Belt-Drive Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Duct Fans.
    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Also known as axial duct fans, these install inline in ductwork for use as an exhaust, supply, or booster fan. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC, 230V AC, Single Phase—Hardwire
    12"11,400 ft³/min @ 3/8 in. H₂O
    1,600 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.3,4501/214 1/16"23 7/16"12"175SteelAluminum
    No7/16"0000000000000000
    15"12,800 ft³/min @ 3/8 in. H₂O
    3,200 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,2753/417 1/16"26 15/16"12"175SteelAluminum
    No7/16"000000000000000
    18"12,500 ft³/min @ 3/8 in. H₂O
    3,400 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,6001/220 1/16"30 3/16"12"175SteelAluminum
    No7/16"000000000000000
     
    230V AC, 460V AC, Three Phase—Hardwire
    18"14,400 ft³/min @ 3/8 in. H₂O
    4,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,150120 1/16"30 3/16"12"175SteelAluminum
    No7/16"000000000000000
    24"17,000 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.1,8001 1/226 11/16"36 11/16"12"175SteelAluminum
    No7/16"000000000000000
    36"113,300 ft³/min @ 3/8 in. H₂O
    15,200 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,000239 1/4"49 1/4"16"175SteelAluminum
    No7/16"000000000000000
     

    Belt-Drive Corrosion-Resistant Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Corrosion-Resistant Duct Fans.
    A 304 stainless steel housing offers good corrosion resistance. All of these belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing Material
    Blade Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC, 460V AC, Three Phase—Hardwire
    12"11,600 ft³/min @ 3/8 in. H₂O
    1,800 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.3,0503/414 1/16"25 5/8"20"200304 Stainless SteelStainless Steel
    No7/16"0000000000000000
    18"14,600 ft³/min @ 3/8 in. H₂O
    4,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,3501 1/220 1/16"32 11/16"20"200304 Stainless SteelStainless Steel
    No7/16"000000000000000
    24"17,200 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,700226 11/16"38 3/4"21"200304 Stainless SteelStainless Steel
    No7/16"000000000000000
     

    Belt-Drive Hazardous Location Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Hazardous Location Duct Fans.
    These fans have an explosion-proof motor that is rated for hazardous environments. All are belt-drive fans that are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. UL and CSA standards apply to the motor.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    IP44 Enclosure Rating—Fans rated IP44 have a motor enclosure that's rated for protection in damp environments.
    IP56 Enclosure Rating— Fans rated IP56 have a motor enclosure that’s rated for protection in damp, dusty, and washdown environments.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Certification
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC, 230V AC, Single Phase—Hardwire
     
    IP44 Enclosure Rating
    12"11,400 ft³/min @ 3/8 in. H₂O
    1,600 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.3,0251/214 1/16"23 7/16"12"175SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"0000000000000000
    15"12,800 ft³/min @ 3/8 in. H₂O
    3,200 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,2753/417 1/16"26 15/16"12"175SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
    18"12,500 ft³/min @ 3/8 in. H₂O
    3,400 ft³/min @ 1/8 in. H₂O
    60 dBA @ 15 ft.1,6001/220 1/16"30 3/16"12"175SteelAluminum
    UL Listed, UL Recognized Component, CSA Certified
    No7/16"000000000000000
     
    230V AC, 460V AC, Three Phase—Hardwire
     
    IP44 Enclosure Rating
    18"14,400 ft³/min @ 3/8 in. H₂O
    4,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,150120 1/16"30 3/16"12"175SteelAluminum
    UL Recognized Component, CSA Energy Verified, CSA Certified
    No7/16"000000000000000
    36"113,300 ft³/min @ 3/8 in. H₂O
    15,200 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.1,000239 1/4"49 1/4"16"175SteelAluminum
    UL Listed, UL Recognized Component, CSA Energy Verified, CSA Certified
    No7/16"000000000000000
     
    IP56 Enclosure Rating
    24"17,000 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.1,8001 1/226 11/16"36 11/16"12"175SteelAluminum
    UL Listed
    No7/16"000000000000000
     

    Exterior-Wall-Mount Exhaust Fans

    Good when you don't have room to mount an exhaust fan inside your facility, these fans attach to openings in outside walls. Use them to draw stagnant and humid air out of a room or area.
    Note: Airflow depends on the resistance created by louvers, filters, and ductwork in your system. This resistance, known as static pressure (SP), is measured in inches of water.
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Totally Enclosed Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments. They mount through the wall, so you'll need to cut a hole on the inside of the wall as well.
    Belt Drive—Belt-drive fans are quieter than direct-drive fans. They also last longer because their components can be replaced if damaged.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Includes
    Each
    50"12,100 ft³/min @ 0 in. H₂O
    16,200 ft³/min @ 0.2 in. H₂O
    Not RatedBelt1,7251150"56"56"63"47 1/4"104SteelNoLouvers0000000000000000
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Totally Enclosed Motor Enclosure. Exterior-Wall-Mount Exhaust Fans.
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments. They mount through the wall, so you'll need to cut a hole on the inside of the wall as well.
    Belt Drive—Belt-drive fans are quieter than direct-drive fans. They also last longer because their components can be replaced if damaged.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Wd.
    Dia.
    Dp.
    Ambient
    Temp., ° F
    Blade
    Material
    Mounting Fasteners
    Included
    Includes
    Each
    50"12,100 ft³/min @ 0.2 in. H₂O
    21,600 ft³/min @ 0 in. H₂O
    Not RatedBelt80031/250"56"56"63"47 1/4"104SteelNoLouvers0000000000000000