McMaster-Carr logo
    Filter by
    Electrical Phase
    Mounting Location
    Draft Direction
    Drive Type
    Number of Speeds
    Opening Width
    Ambient Temperature
    Housing Material
    Power Source
    Blade Material
    For Duct Shape
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    46 Products

    Direct-Drive Upblast Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 1.

    Style 1

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. These exhaust fans draw stagnant and humid air out through your roof and then expel it up and away from the roof surface. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Brushless Motor—Fans with a brushless motor have advanced electronic controls that allow them to precisely operate at wide range of speeds, making them more efficient, quieter, and longer lasting than fans with a standard motor.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC, Single Phase—Hardwire
    19"300 ft³/min @ 1/2 in. H₂O
    400 ft³/min @ 0 in. H₂O
    54 dBA @ 5 ft.1,3001/3217 3/4"14 1/2"19"40120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    111"400 ft³/min @ 1/2 in. H₂O
    710 ft³/min @ 0 in. H₂O
    60 dBA @ 5 ft.1,6253/1622"18"19"43300Aluminum
    AMCA Certified, ETL Listed
    00000000000000000000000000
    111 3/4"750 ft³/min @ 1/2 in. H₂O
    1,050 ft³/min @ 0 in. H₂O
    59 dBA @ 5 ft.1,3001/425 1/2"25 1/4"21"67300Aluminum
    AMCA Certified, ETL Listed
    00000000000000000000000000
    112"1,100 ft³/min @ 1/2 in. H₂O
    1,300 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,6251/325 1/2"25 1/4"21"50300Aluminum
    AMCA Certified, ETL Listed
    00000000000000000000000000
    113 3/4"1,500 ft³/min @ 1/2 in. H₂O
    1,950 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,4751/228 7/8"27 1/4"21"78300Aluminum
    AMCA Certified, ETL Listed
    00000000000000000000000000
    116"2,450 ft³/min @ 1/2 in. H₂O
    2,900 ft³/min @ 0 in. H₂O
    69 dBA @ 5 ft.1,6253/431 7/8"30 1/2"24 3/4"80300Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
     
    208 to 230V AC, Three Phase—Hardwire
    118 3/4"3,750 ft³/min @ 1/2 in. H₂O
    4,100 ft³/min @ 0 in. H₂O
    68 dB @ 5 ft.1,150237 3/8"33 3/4"28"184300Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    120 3/4"5,900 ft³/min @ 1/2 in. H₂O
    6,450 ft³/min @ 0 in. H₂O
    85 dBA @ 5 ft.1,425537 3/8"33 1/4"28"221300Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    124"7,000 ft³/min @ 1/2 in. H₂O
    7,750 ft³/min @ 0 in. H₂O
    72 dBA @ 5 ft.900341 7/8"37 1/2"33"312300Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    130"9,500 ft³/min @ 1/2 in. H₂O
    10,500 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.725551 1/4"44"40"497300Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
     
    Totally Enclosed Motor Enclosure—Brushless Motor
     
    120V AC, Single Phase—Hardwire
    111 3/4"1,050 ft³/min @ 1/2 in. H₂O
    1,300 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.1,5751/325 1/2"25 1/4"21"64300Aluminum
    AMCA Certified, ETL Listed
    00000000000000000000000000
    113 3/4"1,550 ft³/min @ 1/2 in. H₂O
    2,000 ft³/min @ 0 in. H₂O
    69 dBA @ 5 ft.1,5001/228 7/8"27 1/4"21"71300Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    115 3/4"2,850 ft³/min @ 1/2 in. H₂O
    3,200 ft³/min @ 0 in. H₂O
    72 dBA @ 5 ft.1,550131 7/8"30 1/2"24 3/4"87300Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
     

    Direct-Drive Downdraft Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Downdraft Roof-Mount Exhaust Fans, Style 1.
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Downdraft Roof-Mount Exhaust Fans, Style 2.

    Style 1

    Style 2

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Brushless Motor—Fans with a brushless motor are more efficient than fans with a standard motor. They operate at a wide range of speeds for precise speed control and greater energy savings. They’re also quieter and have a longer lifespan because of their advanced electronic controls.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC, Single Phase—Hardwire
    19"100 ft³/min @ 1/2 in. H₂O
    400 ft³/min @ 0 in. H₂O
    50 dBA @ 5 ft.1,2501/3220 3/4"14 1/2"19"40120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    116"2,600 ft³/min @ 1/2 in. H₂O
    3,100 ft³/min @ 0 in. H₂O
    70 dBA @ 5 ft.1,4503/433 1/4"23 3/8"24"77120Aluminum
    AMCA Certified, ETL Listed
    00000000000000000000000000
     
    208/230V AC Three Phase—Hardwire
    219"4,500 ft³/min @ 1/2 in. H₂O
    5,000 ft³/min @ 0 in. H₂O
    75 dBA @ 5 ft.1,300238 15/16"32 3/4"28"189120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    221"6,200 ft³/min @ 1/2 in. H₂O
    6,700 ft³/min @ 0 in. H₂O
    82 dBA @ 5 ft.1,400538 15/16"32 1/4"28"201120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    224"8,100 ft³/min @ 1/2 in. H₂O
    9,000 ft³/min @ 0 in. H₂O
    73 dBA @ 5 ft.925343 7/16"37 1/4"33"288120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    230"10,400 ft³/min @ 1/2 in. H₂O
    11,500 ft³/min @ 0 in. H₂O
    69 dBA @ 5 ft.700552 13/16"44"40"467120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    236"11,000 ft³/min @ 1/2 in. H₂O
    13,500 ft³/min @ 0 in. H₂O
    64 dBA @ 5 ft.450563 5/16"49 1/2"44"532120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
     
    Totally Enclosed Motor Enclosure—Brushless Motor
     
    120V AC, Single Phase—Hardwire
    112"1,000 ft³/min @ 1/2 in. H₂O
    1,300 ft³/min @ 0 in. H₂O
    66 dBA @ 5 ft.1,5751/326 1/4"19 1/8"21"54120Aluminum
    AMCA Certified, ETL Listed
    00000000000000000000000000
    114"1,900 ft³/min @ 1/2 in. H₂O
    2,300 ft³/min @ 0 in. H₂O
    68 dBA @ 5 ft.1,5251/229 3/4"21 3/4"21"61120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
    116"2,850 ft³/min @ 1/2 in. H₂O
    3,300 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.1,525133 1/4"23 3/8"24"74120Aluminum
    AMCA Certified, ETL Listed
    0000000000000000000000000000
     

    Direct-Drive Exhaust Fans

    With fewer moving parts than belt-drive fans, these direct-drive exhaust fans require less maintenance. They have a built-in grease pan to collect waste while cooking. Mount these fans directly to your roof with the attached mounting brackets. They meet UL standards for ventilation in residential, commercial, and institutional kitchens.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Exhaust Fans.
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Overall
    Ht.
    Base
    Wd.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Features
    Specs. Met
    Certification
    Each
    12"1,250 ft³/min @ 1/2 in. H₂O
    1,500 ft³/min @ 0 in. H₂O
    64 dB @ 5 ft.Direct1,725Variable151 1/8"29 1/2"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    0000000000000000
    14"2,100 ft³/min @ 1/2 in. H₂O
    2,500 ft³/min @ 0 in. H₂O
    66 dB @ 5 ft.Direct1,650Variable155 3/8"31"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    000000000000000
    208V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Exhaust Fans.
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Overall
    Ht.
    Base
    Wd.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Features
    Specs. Met
    Certification
    Each
    16"3,000 ft³/min @ 1/2 in. H₂O
    3,500 ft³/min @ 0 in. H₂O
    71 dB @ 5 ft.Direct1,650Variable1 1/259 3/4"32 5/8"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    0000000000000000
    19"3,800 ft³/min @ 1/2 in. H₂O
    4,500 ft³/min @ 0 in. H₂O
    76 dB @ 5 ft.Direct1,175Variable1 1/266 1/8"37 1/2"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    000000000000000
    21"5,000 ft³/min @ 1/2 in. H₂O
    5,500 ft³/min @ 0 in. H₂O
    77 dB @ 5 ft.Direct1,275Variable371 7/8"38 1/4"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    000000000000000
    25"5,500 ft³/min @ 1/2 in. H₂O
    6,500 ft³/min @ 0 in. H₂O
    72 dB @ 5 ft.Direct900Variable380 3/8"49 1/4"350SteelSteelGrease PanUL 705, UL 762, ULC-S645ETL Listed
    000000000000000
    31"7,000 ft³/min @ 1/2 in. H₂O
    8,500 ft³/min @ 0 in. H₂O
    72 dB @ 5 ft.Direct675Variable585 7/8"52 1/4"350SteelSteelGrease PanUL 705, UL 762, ULC-S645ETL Listed
    000000000000000
    37"12,000 ft³/min @ 1/2 in. H₂O
    14,000 ft³/min @ 0 in. H₂O
    72 dB @ 5 ft.Direct575Variable7 1/293 1/4"59"350SteelSteelGrease PanUL 705, UL 762, ULC-S645ETL Listed
    000000000000000

    Motion-Activated Ceiling-Mount Lavatory Exhaust Fans

    When a room is occupied, these fans detect the motion and turn on. Set them to turn off anywhere from 30 seconds to 80 minutes after motion is no longer detected. They also sense humidity levels in the room and turn the fan on until the humidity level falls below a set percentage. You can set them to a maximum of 80% relative humidity.
    Exhaust Fans
    Image of Product. Front orientation. Exhaust Fans. Motion-Activated Ceiling-Mount Lavatory Exhaust Fans.
    Guard
    For
    Opening
    For Duct
    Wd.
    Airflow,
    ft³/min
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Lg.
    Wd.
    Dp.
    Housing
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Features
    Each
    For Round Duct
     
    120V AC, Single Phase—Hardwire
    6"1302314 1/4"14 1/4"13"12 7/8"9 7/8"SteelNo3/8"Backdraft-Preventing Damper00000000000000
     
    Exhaust Fans with LED
    Image of Product. Front orientation. Exhaust Fans. Motion-Activated Ceiling-Mount Lavatory Exhaust Fans, Exhaust Fans with LED.
    Guard
    For
    Opening
    For Duct
    Wd.
    Airflow,
    ft³/min
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Lg.
    Wd.
    Dp.
    Housing
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Features
    Each
    For Round Duct
     
    120V AC, Single Phase—Hardwire
    6"1302317"15 7/8"13"12 7/8"9 7/8"SteelNo3/8"Backdraft-Preventing Damper, Light00000000000000
     

    Smoke Removal Blowers

    Quickly ventilate smoke, gas, and other fumes by forcing fresh air into your space instead of exhausting air out. These fans improve air quality and manage temperature and moisture levels.
    Battery Powered
    Image of Product. Front orientation. Blowers. Smoke Removal Blowers, Battery Powered, Mobile.
    Image of Product. Front orientation. Blowers. Smoke Removal Blowers, Battery Powered, Portable.

    Mobile

    Portable

    Plastic Housing—Blowers with a plastic housing have good corrosion resistance.
    Powder-Coated Aluminum Housing—Blowers with an aluminum housing are easy to roll and lift.
    Overall
    Battery
    Charger
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Run Time,
    min.
    Batteries
    Included
    Included
    Voltage,
    V AC
    Temp. Range,
    ° F
    Housing Material
    Enclosure
    Rating
    Each
    Mobile
     
    Totally Enclosed Motor Enclosure
    10,80073 dBA @ 15 ft.3,200Variable3/424 3/8"22 7/8"11 3/4"5145YesYes1200 to 110Powder-Coated AluminumIP65
    0000000000000000
     
    Portable
     
    Totally Enclosed Motor Enclosure
    10,90073 dBA @ 15 ft.2,350Variable3/421"22"11"5150YesYes1200 to 110PlasticIP66
    000000000000000
    10,90073 dBA @ 15 ft.2,350Variable3/421"22"11"5150YesYes2400 to 110PlasticIP66
    000000000000000
     
    Replacements for Blowers
    back to top