    High-Output Hazardous Location Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard hazardous location spark-resistant blowers can handle. They have an explosion-proof motor that is UL listed for hazardous locations. They also have an aluminum housing for spark resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Round Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. High-Output Hazardous Location Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    130 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/34"4"7"13 5/8"14 3/4"12 1/8"567.0 amp/3.5 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"0000000000000000
    250 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/24"4"8 1/8"13 5/8"14 3/4"12 1/8"497.4 amp/3.7 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"000000000000000
     
    230V AC/460V AC
     
    Three Phase—Hardwire
    250 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/24"4"8 1/8"13 5/8"14 3/4"12 1/8"472.2 amp/1.1 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"000000000000000
     

    High-Output Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard spark-resistant blowers can handle. They have an aluminum housing for spark resistance. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    130 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/34"4"7"13 5/8"14 3/4"12 1/8"415.6 amp/2.8 amp0 to 100AluminumNo7/16"0000000000000000
    250 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/24"4"8 1/8"13 5/8"14 3/4"12 1/8"487.2 amp/3.6 amp0 to 100AluminumNo7/16"000000000000000
     
    230V AC/460V AC
     
    Three Phase—Hardwire
    250 ft³/min @ 3 in. H₂O75 dBA @ 15 ft.3,4501/24"4"8 1/8"13 5/8"14 3/4"12 1/8"401.8 amp/0.9 amp0 to 100AluminumNo7/16"000000000000000
     