McMaster-Carr logo
    Filter by
    Blade Diameter
    Mounting Location
    Electrical Phase
    Overall Height
    Opening Width
    Blade Material
    Number of Speeds
    Drive Type
    Overall Width
    Environment
    Power Source
    NEC Hazardous Location Temperature Classification
    DFARS Specialty Metals
    Electrical Connection Type
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Height
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    6 Products

    Direct-Drive Wall-Mount Exhaust Fans

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Direct-Drive Wall-Mount Exhaust Fans .
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Exhaust Fan Collars—Use a collar (sold separately) to connect these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Certification
    Each
    Each
    10"80057 dBA @ 5 ft.Direct1,55011/2016 1/8"16 1/8"8 3/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    0000000000000000000000000000
    12"1,50060 dBA @ 5 ft.Direct1,55011/816 1/8"16 1/8"8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Back orientation. 120V AC. Direct-Drive Wall-Mount Exhaust Fans .
    Louvers—Fans with louvers create a weather-tight seal when they're turned off. The louvers open automatically on startup and spring closed when not in use.
    Hoods—Hoods (sold separately) help extend the life of your exhaust fan by protecting it from harsh weather, such as severe wind, and debris.
    Exhaust Fans
    Hoods
    For
    Opening
    Overall
    Mounting
    Hole
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Dia.
    Location
    No.
    of
    Includes
    Each
    Each
    12"900Not RatedDirect1,72511/1013 3/4"13 3/4"16 1/8"16 1/8"15 3/16"100Galvanized SteelAluminum
    3/16"Frame4Louvers0000000000000000000000000000

    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Each
    Each
    12"1,600Not RatedDirect1,72511/416 1/8"16 1/8"17 3/4"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    000000000000000000000000000000
    back to top