    DC Equipment-Cooling Fans

    Running on 48V DC power or lower, these compact fans fit inside electronics and other small, heat-sensitive equipment to keep things cool. They're also known as muffin fans. Some meet American and Canadian safety standards.
    Square
    Image of Product. Front orientation. Fans. DC Equipment-Cooling Fans, Square.
    Plain Bearing—Fans with plain bearings are good for less demanding applications, such as cooling prototypes or parts that aren’t used often.
    Overall
    Mounting
    Airflow
    Temp. Range,
    ° F
    Volume
    Current
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Bearing
    Type
    Fasteners
    Included
    Hole Dia.
    Certification
    Each
    12V DC—Wire Leads
    104.4 ft³/min15 to 15545 dBA0.56 amp4.72" (120 mm)4.72" (120 mm)0.98" (25 mm)PlasticPlasticPlain
    No0.177" (4.5 mm)C-UL Recognized Component, UL Recognized Component
    0000000000000
     
    24V DC—Wire Leads
    108 ft³/min15 to 15545 dBA0.24 amp4.72" (120 mm)4.72" (120 mm)0.98" (25 mm)PlasticPlasticPlain
    No0.17" (4.3 mm)C-UL Recognized Component, UL Recognized Component
    000000000000
     

    DC Wet-Location Equipment-Cooling Fans

    Operate these fans with a DC power source. Also known as muffin fans, they keep heat-sensitive equipment such as electronic components cool. All have ball bearings to lower the heat that is generated from the fans for a longer service life.
    Square
    Image of Product. Front orientation. Fans. DC Wet-Location Equipment-Cooling Fans.
    Overall
    Mounting
    Airflow
    Temp. Range,
    ° F
    Volume
    Current
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Bearing
    Type
    Fasteners
    Included
    Hole Dia.
    Enclosure
    Rating
    Certification
    Each
    12V DC—Wire Leads
    85.5 ft³/min15 to 15536 dBA0.81 amp4.72" (120 mm)4.72" (120 mm)0.98" (25 mm)PlasticPlasticBall
    No0.169" (4.3 mm)IP57
    C-UL Recognized Component, CE Marked, UL Recognized Component
    00000000000000
    119 ft³/min15 to 15541 dBA0.60 amp4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)PlasticPlasticBall
    No0.18" (4.57 mm)IP58
    C-UL Recognized Component, CE Marked, UL Recognized Component
    000000000000
     
    24V DC—Wire Leads
    110 ft³/min15 to 15544 dBA0.24 amp4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)PlasticPlasticBall
    No0.18" (4.57 mm)IP58
    C-UL Recognized Component, CE Marked, UL Recognized Component
    000000000000
     

    Hazardous Location Equipment-Cooling Fan Kits

    Cool electronics and other sensitive equipment in potentially unsafe areas. These fans are non-sparking, so they’re safe for use around gas and explosive dust. They also withstand washdowns, occasional submersion in water, and wet weather. They’re not for use in mines. Ball bearings reduce the heat that’s generated to prolong fan lifespan.
    Square
    Image of Product. Front orientation. Fans. Hazardous Location Equipment-Cooling Fan Kits.
    Overall
    Mounting
    Ht.
    Wd.
    Dp.
    Airflow,
    ft³/min
    Temp. Range,
    ° F
    Volume (Sound),
    dBA
    Current,
    amp
    Frame
    Material
    Fasteners
    Included
    Hole Dia.
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Guard
     
    120V AC, Single Phase, 50 Hz, 60 Hz—Two Blade Plug
    4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)1060 to 155430.08AluminumNo0.17" (4.3 mm)ATEX II 3 G Ex nA IIC Gc; IEC Zone 2 Groups IIC, IIB, IIAIP68
    C-UL Listed, UL Listed, UL Recognized Component
    00000000000000
     

    Hazardous Location Equipment-Cooling Fans

    Safely cool electronics and equipment where explosive gases could be present due to equipment failure. ATEX certified, these fans meet European standards for hazardous locations. They’re also IP rated, so they seal out dust and are protected from water if briefly submersed. All have ball bearings that decrease noise for quiet operation. Their bearings reduce heat as they run as well, extending their life.
    Square
    Image of Product. Front orientation. Fans. Hazardous Location Equipment-Cooling Fans, Square.
    Overall
    Mounting
    Airflow
    Temp. Range,
    ° F
    Volume
    Current
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole Dia.
    Enclosure
    Rating
    Certification
    Each
    100V AC to 240V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminal
    124 ft³/min0 to 15549 dBA0.18 amp4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)PlasticPlasticATEX II 3 G Ex Ec IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.17" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    0000000000000
     
    100V AC to 240V AC, Single Phase, 50Hz/60Hz—Wire Leads
    124 ft³/min0 to 15549 dBA0.18 amp4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)PlasticPlasticATEX II 3 G Ex Ec IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.17" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    000000000000
     
    115V AC to 230V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminal
    106 ft³/min0 to 15543 dBA0.08 amp4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)PlasticPlasticATEX II 3 G Ex nA IIC Gc; IEC Zone 2 Groups IIC, IIB, IIANo0.17" (4.3 mm)IP68
    C-UL Recognized Component, CE Marked, TUV Rheinland Certified, UL Recognized Component
    000000000000
     

    Submersible DC Equipment-Cooling Fans

    Keep electronics cool in wet areas. These fans withstand weather, washdowns, and occasional time spent underwater. A ball bearing keeps them running smoothly and quietly, reducing friction to increase their lifespan.
    Square
    Image of Product. Front orientation. Fans. Submersible DC Equipment-Cooling Fans, Square.
    Overall
    Mounting
    Ht.
    Wd.
    Dp.
    Airflow,
    ft³/min
    Temp. Range,
    ° F
    Volume (Sound),
    dBA
    Current,
    amp
    Fasteners
    Included
    Hole Dia.
    Enclosure
    Rating
    Certification
    Each
    Plastic Frame with Plastic Blades
     
    12V DC, Wire Leads
    4.72" (120 mm)4.72" (120 mm)0.98" (25 mm)8015 to 155410.65No0.17" (4.4 mm)IP68
    CE Marked, TUV Rheinland Certified, UL Recognized Component
    0000000000000
     
    24V DC, Wire Leads
    4.72" (120 mm)4.72" (120 mm)0.98" (25 mm)8015 to 155410.14No0.17" (4.4 mm)IP68
    CE Marked, TUV Rheinland Certified, UL Recognized Component
    000000000000
     
    48V DC, Wire Leads
    4.72" (120 mm)4.72" (120 mm)1.5" (38 mm)27115 to 155681.00No0.18" (4.5 mm)IP68
    CE Marked, TUV Rheinland Certified, UL Recognized Component
    000000000000
     