About Air Conditioner Cooling Capacity
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
DC Equipment-Cooling Fans
Running on 48V DC power or lower, these compact fans fit inside electronics and other small, heat-sensitive equipment to keep things cool. They're also known as muffin fans. Some meet American and Canadian safety standards.
Fans with ball bearings generate less heat as they run, so they have a longer life than fans with sleeve bearings.
Fans with sleeve bearings are good for less demanding applications, such as cooling prototypes or parts that aren’t used often.
Fans with quick-disconnect (QD) terminals are compatible with quick-disconnect power cords.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Airflow, cfm | Bearing Type | Temp. Range, °F | Volume, dBA | Current, A | Frame Material | Blade Material | Mounting Fasteners Included | Mounting Hole DIa. | Specifications Met | Each | |
48V DC—Wire Leads | ||||||||||||||
2.36" (60 mm) | 2.36" (60 mm) | 0.98" (25 mm) | 33 | Ball | 0° to 155° | 43 | 0.09 | Plastic | Plastic | No | 0.15" (3.7 mm) | UL Recognized Component, CSA Certified, C-UL Recognized Component | 00000000 | 000000 |
3.15" (80 mm) | 3.15" (80 mm) | 0.98" (25 mm) | 41 | Ball | 0° to 155° | 32 | 0.04 | Plastic | Plastic | No | 0.17" (4.3 mm) | UL Recognized Component, CSA Certified, C-UL Recognized Component | 00000000 | 00000 |
3.15" (80 mm) | 3.15" (80 mm) | 1.5" (38 mm) | 131 | Ball | 0° to 155° | 71 | 0.77 | Plastic | Plastic | No | 0.17" (4.3 mm) | UL Recognized Component, CSA Certified, C-UL Recognized Component | 00000000 | 000000 |
3.62" (92 mm) | 3.62" (92 mm) | 1.5" (38 mm) | 86 | Ball | 0° to 155° | 55 | 0.20 | Plastic | Plastic | No | 0.17" (4.3 mm) | UL Recognized Component, CSA Certified, C-UL Recognized Component | 00000000 | 00000 |
3.62" (92 mm) | 3.62" (92 mm) | 1.5" (38 mm) | 139 | Ball | 0° to 155° | 69 | 0.61 | Plastic | Plastic | No | 0.17" (4.3 mm) | UL Recognized Component, CSA Certified, C-UL Recognized Component | 00000000 | 000000 |
4.69" (119 mm) | 4.69" (119 mm) | 1.26" (32 mm) | 100 | Ball | 0° to 165° | 45 | 0.11 | Plastic | Plastic | No | 0.17" (4.3 mm) | UL Recognized Component, CSA Certified, C-UL Recognized Component | 00000000 | 00000 |
5" (127 mm) | 5" (127 mm) | 1.5" (38 mm) | 200 | Ball | 0° to 145° | 58 | 0.38 | Plastic | Plastic | No | 0.17" (4.3 mm) | UL Recognized Component, CSA Certified, C-UL Recognized Component | 00000000 | 000000 |
5.32" (135 mm) | 5.32" (135 mm) | 1.5" (38 mm) | 153 | Ball | -10° to 160° | 48 | 0.20 | Aluminum | Steel | No | 0.17" (4.3 mm) | UL Recognized Component, CSA Certified, C-UL Recognized Component | 00000000 | 000000 |
48V DC—Quick-Disconnect Terminals with Male Fan Plug | ||||||||||||||
4.69" (119 mm) | 4.69" (119 mm) | 1.5" (38 mm) | 94 | Sleeve | 15° to 165° | 43 | 0.08 | Aluminum | Plastic | No | 0.15" (3.8 mm) | UL Recognized Component, CSA Certified | 00000000 | 00000 |
DC Wet-Location Equipment-Cooling Fans
Operate these fans with a DC power source. Also known as muffin fans, they keep heat-sensitive equipment such as electronic components cool. All have ball bearings to lower the heat that is generated from the fans for a longer service life.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Airflow, cfm | Temp. Range, °F | Volume, dBA | Current, A | Frame Material | Blade Material | Bearing Type | Mounting Fasteners Included | Mounting Hole Dia. | Environmental Rating | Each | |
Square | ||||||||||||||
48V DC—Wire Leads | ||||||||||||||
2.36" (60 mm) | 2.36" (60 mm) | 0.98" (25 mm) | 25.3 | 15° to 155° | 32.3 | 0.07 | Plastic | Plastic | Ball | No | 0.169" (4.3 mm) | IP58 | 00000000 | 000000 |
2.76" (70 mm) | 2.76" (70 mm) | 0.98" (25 mm) | 39.9 | 15° to 155° | 37 | 0.09 | Plastic | Plastic | Ball | No | 0.169" (4.3 mm) | IP58 | 00000000 | 00000 |
3.15" (80 mm) | 3.15" (80 mm) | 0.98" (25 mm) | 50 | 15° to 155° | 40.1 | 0.24 | Plastic | Plastic | Ball | No | 0.169" (4.3 mm) | IP58 | 00000000 | 00000 |
3.62" (92 mm) | 3.62" (92 mm) | 0.98" (25 mm) | 56.8 | 15° to 155° | 38 | 0.17 | Plastic | Plastic | Ball | No | 0.169" (4.3 mm) | IP58 | 00000000 | 00000 |
4.72" (120 mm) | 4.72" (120 mm) | 1.5" (38 mm) | 178.4 | 15° to 155° | 54 | 0.70 | Plastic | Plastic | Ball | No | 0.169" (4.3 mm) | IP58 | 00000000 | 00000 |
5.98" (152 mm) | 6.77" (172 mm) | 2" (51 mm) | 350 | 15° to 155° | 66 | 1.45 | Aluminum | Plastic | Ball | No | 0.177" (4.5 mm) | IP58 | 00000000 | 00000 |
High-Pressure Washdown DC Equipment-Cooling Fans
Keep electronics from overheating in places that must be sanitized often. These DC-powered fans are rated IP69K, meaning you won’t damage them with harsh jets of water and they block out dust. For a long life, all have ball bearings that reduce friction and heat as they operate. Also called muffin fans.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Height, mm | Width, mm | Depth, mm | Airflow, cfm | Volume, dBA | Current, A | Mounting Fasteners Included | Mounting Hole Diameter, mm | Environmental Rating | Specifications Met | Each | |
Plastic Frame with Plastic Blades | |||||||||||
48V DC—Wire Leads | |||||||||||
60 | 60 | 25 | 28 | 30 | 0.07 | No | 4.3 | IP69K | CE Marked, UL Recognized Component | 0000000 | 000000 |
80 | 80 | 25 | 40 | 33 | 0.08 | No | 4.3 | IP69K | CE Marked, UL Recognized Component | 0000000 | 00000 |
80 | 80 | 32 | 77 | 50.1 | 0.16 | No | 4.1 | IP69K | CE Marked, UL Recognized Component | 0000000 | 00000 |
92 | 92 | 25 | 50 | 35 | 0.09 | No | 4.3 | IP69K | CE Marked, UL Recognized Component | 0000000 | 00000 |
92 | 92 | 38 | 100 | 56.2 | 0.25 | No | 4.5 | IP69K | CE Marked, UL Recognized Component | 0000000 | 00000 |
120 | 120 | 25 | 120 | 42 | 0.09 | No | 4.4 | IP69K | CE Marked, UL Recognized Component | 0000000 | 00000 |
120 | 120 | 38 | 124 | 44.1 | 0.10 | No | 4.3 | IP69K | CE Marked, UL Recognized Component | 0000000 | 00000 |
Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Height, mm | Width, mm | Depth, mm | Airflow, cfm | Volume, dBA | Current, A | Mounting Fasteners Included | Mounting Hole Diameter, mm | Environmental Rating | Specifications Met | Each | |
Aluminum Frame with Plastic Blades | |||||||||||
48V DC—Wire Leads | |||||||||||
150 | 172 | 51 | 235 | 52 | 0.48 | No | 4.3 | IP69K | CE Marked, UL Recognized Component | 0000000 | 0000000 |
151 | 172 | 51 | 323 | 63.5 | 1.03 | No | 4.5 | IP69K | CE Marked, UL Recognized Component | 0000000 | 000000 |
Submersible DC Equipment-Cooling Fans
Keep electronics cool in wet areas. These fans withstand weather, washdowns, and occasional time spent underwater. A ball bearing keeps them running smoothly and quietly, reducing friction to increase their lifespan.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Height | Width | Depth | Airflow, cfm | Temp. Range, °F | Volume, dBA | Current, A | Mounting Fasteners Included | Mounting Hole Diameter | Environmental Rating | Specifications Met | Each | |
Plastic Frame with Plastic Blades | ||||||||||||
48V DC, Wire Leads | ||||||||||||
3.62" (92 mm) | 3.62" (92 mm) | 1.5" (38 mm) | 167 | 15° to 155° | 65 | 0.60 | No | 0.17" (4.4 mm) | IP68 | UL Recognized Component CE Marked TUV Rheinland Certified | 0000000 | 000000 |
4.72" (120 mm) | 4.72" (120 mm) | 1.5" (38 mm) | 271 | 15° to 155° | 68 | 1.00 | No | 0.18" (4.5 mm) | IP68 | UL Recognized Component CE Marked TUV Rheinland Certified | 0000000 | 00000 |
Thermoelectric Coolers for Enclosures
Also known as Peltier coolers, these coolers use electrical current to transfer heat away from your enclosure while sealing out contaminants. They cool the enclosure to below the ambient temperature. The solid-state thermoelectric components require no maintenance and take up less space than an air conditioner or heat exchanger.
Rated IP66 and NEMA 4X, these coolers withstand weather, washdowns, and corrosive environments. They meet American and European safety standards.
Coolers without a thermostat run continuously when powered. Add a thermostat, timer, or switch to turn them on and off.
An optional extension bracket holds the cooler away from the enclosure wall for more space inside the enclosure.
Add a drain kit to remove moisture when condensation is likely, such as in humid environments and enclosures exposed to rapid temperature changes. The included hose directs water away from electrical components.
For technical drawings and 3-D models, click on a part number.
Coolers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | For Opening | Extension Brackets | Drain Kits | |||||||||||||
Cooling Capacity, Btu/hr. | Airflow, cfm | Wattage, W | Current, A | Height | Width | Depth | Height | Width | Environment | Mounting Fasteners Included | Each | Each | Each | |||
Without Thermostat | ||||||||||||||||
48V DC—Terminal Block | ||||||||||||||||
850 | 70 | 250 | 9.3 | 15 3/4" | 7 1/8" | 6 11/16" | 14 5/8" | 6 1/8" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 000000000 | 0000000 | 0000000 | 0000000 | 0000000 |