    85 Products

    Fire Sprinkler Head Cover Plates

    Image of ProductInUse. Front orientation. Contains Annotated. Fire Sprinkler Head Cover Plates.
    Block the gap between a sprinkler head and the wall or ceiling. Also known as escutcheons, these plates make sure rising heat sets off your sprinklers instead of escaping through the gap.
    Split—Split plates snap together over a sprinkler head that’s already installed.
    Solid—Solid plates must be installed before a sprinkler head.
    Adjustable—Adjustable plates let you customize the depth to conceal pipes that stick out from the wall or ceiling.
    Recessed Mount—Recessed plates sit flush against a surface for a clean look. They have a flat outer ring and an inner ring that extends into the wall or ceiling.
    Each
    Dp.
    Material
    For Sprinkler
    Head Style
    ID
    OD
    Certification
    1-9
    10-Up
    Split
    Image of Product. Front orientation. Fire Sprinkler Head Cover Plates. Split.
     
    For 1/2 NPT Pipe Size
    1/4"Chrome-Plated SteelDown3/4"3"6425T30000000000
    5/8"PlasticDown3/4"3"6425T100000000
     
    For 3/4 NPT Pipe Size
    1/4"Chrome-Plated SteelDown1"3"6425T400000000
     
    Split—Adjustable
    Image of Product. Front orientation. Fire Sprinkler Head Cover Plates. Split—Adjustable.
     
    For 1/2 NPT Pipe Size
    1/4" to 1 5/8"Chrome-Plated SteelDown3/4"3 3/4"6425T500000000
    3/4" to 1 7/8"Chrome-Plated SteelDown3/4"3 3/4"6425T600000000
    2" to 3"Chrome-Plated SteelDown3/4"3 1/2"6425T700000000
    2" to 3"Painted SteelDown3/4"3 1/2"6425T1200000000
    3" to 4"Chrome-Plated SteelDown3/4"4 1/2"6425T80000000000
    3" to 4"Painted SteelDown3/4"4 1/2"6425T130000000000
     
    For 3/4 NPT Pipe Size
    2" to 3"AluminumDown1"3 1/2"9300N110000000000
     
    Split—Recessed
    Image of Product. Top orientation. Fire Sprinkler Head Cover Plates. Split—Recessed.
     
    For 1/2 NPT Pipe Size
    3/4"Chrome-Plated SteelDown3/4"2 7/8"6425T2100000000
    3/4"Painted SteelDown3/4"2 7/8"6425T2200000000
     
    For 3/4 NPT Pipe Size
    3/4"Chrome-Plated SteelDown1"2 7/8"6425T2300000000
     
    Solid
    Image of Product. Top orientation. Fire Sprinkler Head Cover Plates. Solid.
     
    For 1/2 NPT Pipe Size
    1/4"Chrome-Plated SteelDown3/4"3"9300N1200000000
     
    For 3/4 NPT Pipe Size
    1/4"Chrome-Plated SteelDown1"3"9300N1300000000
     
    Solid—Adjustable
    Image of Product. Front orientation. Fire Sprinkler Head Cover Plates. Solid—Adjustable.
     
    For 1/2 NPT Pipe Size
    2" to 3"Chrome-Plated SteelDown3/4"3 1/2"6410T400000000
    2" to 3"Painted SteelDown3/4"3 1/2"6425T2400000000
    3" to 5"Chrome-Plated SteelDown3/4"4 1/2"6425T110000000000
    3" to 5"Painted SteelDown3/4"4 1/2"6425T140000000000
     
    For 3/4 NPT Pipe Size
    2" to 3"Chrome-Plated SteelDown1"3 1/2"6425T2500000000
    2" to 3"Painted SteelDown1"3 1/2"6425T2600000000
     
    Solid—Recessed
    Image of Product. Front orientation. Fire Sprinkler Head Cover Plates. Solid—Recessed.
     
    For 1/2 NPT Pipe Size
    3/4"Chrome-Plated SteelDown3/4"2 7/8"6425T2700000000
    3/4"Chrome-Plated SteelDown3/4"2 7/8"C-UL Listed, UL Listed
    63945T9100000000
    3/4"Painted SteelDown3/4"2 7/8"6425T2800000000
    3/4"Painted SteelDown3/4"2 7/8"C-UL Listed, UL Listed
    6425T12100000000
     
    For 3/4 NPT Pipe Size
    3/4"Chrome-Plated SteelDown1"2 7/8"6425T2900000000
    3/4"Painted SteelDown1"2 7/8"6425T3100000000
     

    Fire Sprinkler Heads

    When a fire starts, these sprinkler heads automatically release water to put it out. Choose a head with the same trigger type and temperature rating as the other heads in your sprinkler system. To comply with NFPA standards, use a sprinkler-head wrench or installation socket (both sold separately) to install and maintain these heads.
    Pipe Mount
    Image of Product. Front orientation. Fire Sprinkler Heads. Fire Sprinkler Heads, Pipe Mount.
    Image of Product. Glass Bulb. Front orientation. ZoomedIn view. Contains Border. Glass-Bulb Trigger. Fire Sprinkler Heads.
    Image of Product. Fusible Link. Front orientation. ZoomedIn view. Contains Border. Fusible-Link Trigger. Fire Sprinkler Heads.

    Glass Bulb

    Fusible Link

    Image of Specification. Down. Front orientation. Contains Border. Down. Fire Sprinkler Heads, Pipe Mount.
    Image of Specification. Up. Front orientation. Contains Border. Up. Fire Sprinkler Heads, Pipe Mount.

    Down

    Up

    Glass-Bulb Trigger—Glass-bulb heads are triggered when heat expands the liquid inside the bulb until it bursts. The color of the liquid indicates the activation temperature—choose a sprinkler head that's the same color as the rest of your sprinkler system.
    Fusible-Link Trigger—Fusible-link heads are triggered by a soft metal alloy that melts at the listed temperature.
    Sprinkler Heads
    Installation
    Wrenches
    1/2 NPT Male
    Connection
    3/4 NPT Male
    Connection
    Temp.
    Each
    Each
    Rating,
    ° F
    Color
    Code
    Material
    Response
    Time Index
    Certification
    Flammability
    Rating
    1-9
    10-Up
    1-9
    10-Up
    Each
    Down with Glass Bulb
    155RedBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T67100000000000064575T4310000000000006410T620000000
    155RedWhite Polyester-Coated Bronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T510000000000———006410T62000000
    175YellowBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T221000000000064575T44100000000006410T62000000
    175YellowWhite Polyester-Coated Bronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T5210000000000———006410T62000000
    200GreenBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T681000000000064575T45100000000006410T62000000
    200GreenWhite Polyester-Coated Bronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T5310000000000———006410T62000000
    286BlueBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T251000000000064575T46100000000006410T62000000
    286BlueWhite Polyester-Coated Bronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T5410000000000———006410T62000000
    360PurpleBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T2710000000000———006410T62000000
    360PurpleWhite Polyester-Coated Bronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T5510000000000———006410T62000000
     
    Up with Glass Bulb
    155RedBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T631000000000064575T43200000000006410T62000000
    175YellowBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T2220000000000———006410T62000000
    200GreenBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T641000000000064575T45200000000006410T62000000
    286BlueBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T252000000000064575T46200000000006410T62000000
    360PurpleBronze80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T272000000000064575T47200000000006410T62000000
     
    Down with Fusible Link
    165Brass80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256410T410000000000———006410T5200000
    212WhiteBrass80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256410T420000000000———006410T5200000
    280BlueBrass80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256410T430000000000———006410T5200000
     
    Up with Fusible Link
    165Brass80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256409T3100000000006410T24200000000006410T5200000
    212WhiteBrass80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256409T3200000000006410T25200000000006410T5200000
    280BlueBrass80FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256409T3300000000006410T26200000000006410T5200000
     
    Recessed Mount
    Image of Product. Front orientation. Fire Sprinkler Heads. Fire Sprinkler Heads, Recessed Mount.
    Image of Product. Glass Bulb. Front orientation. ZoomedIn view. Contains Border. Glass-Bulb Trigger. Fire Sprinkler Heads.
    Image of Product. Fusible Link. Front orientation. ZoomedIn view. Contains Border. Fusible-Link Trigger. Fire Sprinkler Heads.
    Image of Specification. Top orientation. Fire Sprinkler Heads. Fire Sprinkler Heads, Recessed Mount.

    Glass Bulb

    Fusible Link

    Recessed heads are designed for a clean look in finished ceilings. They come with a cover plate to close off the space around the head.
    Glass-Bulb Trigger—Glass-bulb heads are triggered when heat expands the liquid inside the bulb until it bursts. The color of the liquid indicates the activation temperature—choose a sprinkler head that's the same color as the rest of your sprinkler system.
    Fusible-Link Trigger—Fusible-link heads are triggered by a soft metal alloy that melts at the listed temperature.
    Sprinkler Heads
    Replacement
    Cover Plates
    Installation
    Sockets
    1/2 NPT Male
    Connection
    Temp.
    Recess
    Each
    Plate Temp.
    Rating
    Rating,
    ° F
    Color
    Code
    Plate
    Color
    Material
    Dia.
    Dp.
    Response
    Time Index
    Includes
    Certification
    Flammability
    Rating
    1-9
    10-Up
    Each
    Each
    Down with Glass Bulb
    Not Rated155RedChrome-Plated Bronze1 15/16"1"80Cover PlateFM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T12100000000000063945T910000064575T980000000
    Not Rated155RedWhiteWhite Polyester-Coated Bronze1 15/16"1.125"80Cover PlateFM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T13100000000006425T121000064575T98000000
     
    Down with Fusible Link
    Not Rated165Chrome-Plated Brass1 15/16"1"80Cover PlateFM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T141000000000063945T91000064575T88000000
     
    Concealed Mount
    Image of Product. Front orientation. Exploded view. Fire Sprinkler Heads. Fire Sprinkler Heads, Concealed Mount.
    Image of Product. Glass Bulb. Front orientation. ZoomedIn view. Contains Border. Glass-Bulb Trigger. Fire Sprinkler Heads.
    Image of Specification. Top orientation. Fire Sprinkler Heads. Fire Sprinkler Heads, Concealed Mount.

    Glass Bulb

    Concealed heads stay out of sight until they’re needed. Once the temperature hits 139° F, the cover plate falls off to expose the head.
    Glass-Bulb Trigger—Glass-bulb heads are triggered when heat expands the liquid inside the bulb until it bursts. The color of the liquid indicates the activation temperature—choose a sprinkler head that's the same color as the rest of your sprinkler system.
    Sprinkler Heads
    Replacement
    Covers
    Installation
    Sockets
    1/2 NPT Male
    Connection
    Temp.
    Each
    Plate Temp.
    Rating, ° F
    Rating,
    ° F
    Color
    Code
    Plate
    Color
    Material
    Recess
    Dia.
    Response
    Time Index
    Includes
    Certification
    Flammability
    Rating
    1-9
    10-Up
    Each
    Each
    Down with Glass Bulb
    139155RedWhiteBrass2 1/4"80CoverFM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 2564575T1110000000000006496T2120000006496T790000000
     

    Fire Sprinkler Head Installation Tools

    Image of ProductInUse. Front orientation. Fire Sprinkler Head Installation Tools.
    Image of Product. Wrench. Front orientation. Fire Sprinkler Head Installation Tools. Wrench.

    Wrench

    Image of Product. Socket. Front orientation. Fire Sprinkler Head Installation Tools. Socket.

    Socket

    Install fire sprinkler heads without damaging them—these tools are made for specific sprinkler models. They help you meet NFPA 13 and NFPA 25 standards for maintaining your fire sprinkler system.
    Socket—Sockets require a ratchet handle with a 1⁄2" square drive (sold separately).
    Installation Tools
    Ratchet Wrenches
    For Mfr. Series
    For
    Mfr.
    For Pipe
    Size
    For Trigger
    Device
    For Sprinkler
    Head Style
    Each
    Each
    Wrench
    TY-B, TY-FRB, EC-5Tyco1/2, 3/4
    Glass BulbUp, Down, Side6410T620000000———0
    TY-L, TY-FRLTyco1/2, 3/4
    Fusible LinkUp, Down, Side6410T5200000———0
     
    Socket
    TY-BTyco1/2
    Glass BulbDown64575T9800000053125A81000000
    TY-LTyco1/2
    Fusible LinkDown64575T8800000053125A8100000
    RFIITyco1/2
    Glass BulbDown6496T7900000053125A8100000
     

    Quick-Response Fire Sprinkler Heads

    Image of ProductInUse. Front orientation. Contains Annotated, Border, MultipleImages. Fire Sprinkler Heads. Quick-Response Fire Sprinkler Heads.
    Image of ProductInUse. Down. Front orientation. Contains Border. Fire Sprinkler Heads. Quick-Response Fire Sprinkler Heads, Down.

    Down

    Image of ProductInUse. Up. Front orientation. Contains Border. Fire Sprinkler Heads. Quick-Response Fire Sprinkler Heads, Up.
    Image of Product. Top orientation. Fire Sprinkler Heads. Quick-Response Fire Sprinkler Heads.

    Up

    Halt fires fast with these sprinkler heads. With a low response time index, they activate 30% faster than standard sprinkler heads. The color of the liquid indicates the activation temperature--choose a sprinkler head that's the same color as the rest of your sprinkler system. To comply with NFPA standards, use a sprinkler-head wrench (sold separately) to install and maintain these sprinkler heads.
    Sprinkler Heads
    Installation
    Wrenches
    1/2 NPT Male
    Connection
    Temp.
    Each
    Rating,
    ° F
    Color
    Code
    Material
    Response
    Time Index
    Certification
    Flammability
    Rating
    1-9
    10-Up
    Each
    Down with Glass Bulb
    155RedBrass50FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256422T1120000000000006410T620000000
    175YellowBrass50FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256422T12200000000006410T62000000
    286BlueBrass50FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256422T14200000000006410T62000000
     
    Up with Glass Bulb
    200GreenBrass50FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256422T13100000000006410T62000000
    286BlueBrass50FM Approved, UL Listed, C-UL Listed
    NFPA 13, NFPA 256422T14100000000006410T62000000
     

    Fire Sprinkler Head Guards

    Image of ProductInUse. Hook-On Mount Shown Installed. Side1 orientation. Fire Sprinkler Head Guards. Fire Sprinkler Head Guards, Hook On.
    Image of ProductInUse. Screw-On Mount Shown Installed. Side1 orientation. Fire Sprinkler Head Guards. Fire Sprinkler Head Guards, Screw On.

    Hook-On Mount Shown Installed

    Screw-On Mount Shown Installed

    Image of ProductInUse. Hook-On Mount with Water Shield Shown Installed. Side1 orientation. Fire Sprinkler Head Guards. Fire Sprinkler Head Guards, Fire Sprinkler Head Guards with Water Shield, Hook On.

    Hook-On Mount with Water Shield Shown

    Installed

    Image of Product. Hook-On Mount. Front orientation. Fire Sprinkler Head Guards. Fire Sprinkler Head Guards, Hook On.

    Hook-On Mount

    Image of Product. Screw-On Mount. Front orientation. Fire Sprinkler Head Guards. Fire Sprinkler Head Guards, Screw On.

    Screw-On Mount

    Image of Product. Hook-On Mount with Water Shield. Front orientation. Fire Sprinkler Head Guards. Fire Sprinkler Head Guards, Fire Sprinkler Head Guards with Water Shield, Hook On.

    Hook-On Mount with

    Water Shield

    Protect sprinkler heads from damage and tampering.
    Fire Sprinkler Head Guards with Water Shield—Guards with a water shield are made for upward-facing sprinkler heads. They direct spray downward, so it won’t set off sprinklers higher up. They’re often used for in-rack sprinkler systems.
    Hook On—Hook-on guards are easy to install.
    Screw On—Screw-on guards clamp securely onto your sprinkler head with the included lock screw. You can adjust their position up or down on the sprinkler threads.
    Each
    For Pipe
    Size
    For Thread
    Type
    For Sprinkler
    Head Style
    Dia.
    Ht.
    Material
    Color
    Includes
    1-9
    10-Up
    Fire Sprinkler Head Guards
     
    Hook On
    1/2, 3/4
    NPT
    Up, Down, Side2 1/2"3 1/4"Steel
    Red6411T110000000000
     
    Screw On
    1/2
    NPT
    Up, Down4 1/4"2"Steel
    RedLock Screw6411T2500000000
    3/4
    NPT
    Up, Down4 1/4"2"Steel
    RedLock Screw6411T3600000000
     
    Fire Sprinkler Head Guards with Water Shield
     
    Hook On
    1/2, 3/4
    NPT
    Up2 1/2"3 1/4"Steel
    Red6411T1200000000
     

    Fire Sprinkler Head Stoppers

    Image of ProductInUse. Stopper Shown in Use. Side2 orientation. Fire Sprinkler Head Stoppers.
    Image of Product. Front orientation. Fire Sprinkler Head Stoppers.
    Image of Product. Front orientation. Fire Sprinkler Head Stopper Cases.

    Stopper Shown in Use

    Cases

    Stop the flow from a discharged sprinkler head to minimize water damage. Like locking pliers, these stoppers clamp down tightly and stay locked even after you release the handles. That means the rest of your sprinkler system can remain online until you have a chance to repair the head. A fail safe restores water flow to the broken head if a fire breaks out—when temperatures reach 250° F, the handles pop open.
    Cases—Add a case to mount your stopper on the wall for quick access during an emergency.
    Stoppers
    Cases
    For Sprinkler
    Head Style
    For Pipe
    Size
    For Thread
    Type
    Max. Pressure,
    psi
    Lg.
    Material
    Each
    Each
    Up, Down, Side1/2, 3/4
    NPT
    3507 1/4"Steel
    6468T1010000006468T102000000

    Rack-Mount Fire Sprinkler Head Guards

    Image of ProductInUse. Guard for 1 Beam Shown Installed. Front orientation. Fire Sprinkler Head Guards. Rack-Mount Fire Sprinkler Head Guards, Screw On, .
    Image of ProductInUse. Guard for 2 Beams Shown Installed. Front orientation. Fire Sprinkler Head Guards. Rack-Mount Fire Sprinkler Head Guards, Screw On, .

    Guard for 1 Beam Shown Installed

    Guard for 2 Beams Shown Installed

    Image of Product. Guard for 1 Beam. Front orientation. Fire Sprinkler Head Guards. Rack-Mount Fire Sprinkler Head Guards, Screw On, .
    Image of Product. Guard for 2 Beams. Front orientation. Fire Sprinkler Head Guards. Rack-Mount Fire Sprinkler Head Guards, Screw On, .

    Guard for 1 Beam

    Guard for 2 Beams

    Keep forklifts and other vehicles from damaging sprinklers in your rack system. These guards are bright yellow, so they’re easy to spot from a distance. Mount them directly to rack beams.
    Overall
    Each
    For No.
    of Beams
    For Sprinkler
    Head Style
    Lg.
    Wd.
    Ht.
    For Pallet
    Rack Dp.
    Mounting Hardware
    Included
    Material
    Color
    1-9
    10-Up
     
    Screw On
    1Up, Down, Side9 5/8"6"5"YesSteel
    Yellow9073N11000000000000
    2Up, Down, Side35 3/4"6"5"36"YesSteel
    Yellow9073N120000000000
    2Up, Down, Side41 3/4"6"5"42"YesSteel
    Yellow9073N130000000000
    2Up, Down, Side47 3/4"6"5"48"YesSteel
    Yellow9073N1400000000000
     