    Floor Drain Plugs

    Image of Product. Front orientation. Floor Drain Plugs.
    Often used to prevent spills from going down your drain, these plugs resist oil and most chemicals. They are nonabsorbent, washable, and reusable. An eyebolt at the top makes these plugs easy to insert and remove.
    For Drain
    ID
    Plug
    Ht.
    Overall
    Ht.
    Eyebolt Material
    Each
    Yellow Polyurethane Rubber
    2"4 1/4"5"Zinc-Plated Steel2014K220000000
    3"4 1/2"5 1/4"Zinc-Plated Steel2014K23000000
    4"4 7/8"5 5/8"Zinc-Plated Steel2014K21000000
     

    ABS Threaded Cleanout Plugs

    Image of Product. Recessed. Front orientation. Pipe and Fittings. ABS Threaded Cleanout Plugs.

    Recessed

    Close off your drain cleanout pipe with these threaded plugs. Note: If you do not know your pipe size, measure the OD of your existing cleanout plug or the ID of your cleanout fitting and match to the value listed.
    To prevent leaks in threaded connections, apply a sealant to the male threads. Threaded connections can be taken apart as needed for maintenance and repair. For metal threads, use PTFE tape. For plastic threads, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
    Recessed
    Cleanout Plug
    OD/Fitting ID
    For Pipe
    Size
    Thread
    Type
    Material
    Each
    1 7/8"1 1/2
    NPT
    ABS9359T2100000
    2 3/8"2
    NPT
    ABS9359T220000
    2 27/32"2 1/2
    NPT
    ABS9359T230000
    3 15/32"3
    NPT
    ABS9359T240000
    3 31/32"3 1/2
    NPT
    ABS9359T250000
    4 15/32"4
    NPT
    ABS9359T260000
    6 19/32"6
    UNC
    ABS9359T2900000
    Plug Wrenches

    Clog-Resistant Shower Stoppers

    Image of Product. Front orientation. Shower Stoppers. Clog-Resistant Shower Stoppers.
    Prevent clogs from ever forming. Push the top of this stopper 3 to 5 times to plunge and cut trapped material.
    Material
    Dia.
    Ht.
    Each
    Plastic2"2 11/16"2160K17000000

    Adjustable Floor Drain Covers

    Cover unused drains to prevent accidents and help meet OSHA requirements.
    Round
    Image of Product. Front orientation. Floor Drain Covers. Adjustable Floor Drain Covers, Round.
    Dia.
    Thk.
    For Drain
    ID
    Wt. Cap. @ Dia.
    Mounting Hardware
    Included
    Specs. Met
    Each
    Orange Polypropylene
    7"0.375"2" to 5"400 lb. @ 5"
    1,400 lb. @ 2"
    YesOSHA Compliant 29 CFR 1926.5022009T111000000
    15"0.375"3" to 12"1,300 lb. @ 12"
    2,900 lb. @ 6"
    YesOSHA Compliant 29 CFR 1926.5022009T100000
     
    Square
    Image of Product. Front orientation. Floor Drain Covers. Adjustable Floor Drain Covers, Square.
    For
    Drain
    Lg.
    Wd.
    Thk.
    Lg.
    Wd.
    Weight Cap. @ Hole Size
    Mounting Hardware
    Included
    Specs. Met
    Each
    Orange Polypropylene
    15"15"0.375"4" to 12"4" to 12"1,400 lb. @ 12" length × 12" widthYesOSHA Compliant 29 CFR 1926.5022009T112000000
     
    Rectangle
    Image of Product. Front orientation. Floor Drain Covers. Adjustable Floor Drain Covers, Rectangle.
    For
    Drain
    Lg.
    Wd.
    Thk.
    Lg.
    Wd.
    Weight Cap. @ Hole Size
    Mounting Hardware
    Included
    Specs. Met
    Each
    Orange Polypropylene
    15"8"0.375"4" to 12"4" to 6"1,200 lb. @ 12" length × 6" width
    4,100 lb. @ 7" length × 4" width
    YesOSHA Compliant 29 CFR 1926.5022009T113000000
     

    Floor Drain Check Valves

    Image of Product. Front orientation. Drain Check Valves.
    Put an end to water damage from backed-up sewers. To install, place a valve into your floor drain pipe and tighten the screws—the rubber collar will expand for proper fit. When water backs up, the rubber float will rise to seal off the drain. When water recedes, the float will drop for normal drainage.
    For Pipe
    Size
    Each
    2
    2495K12000000
    3
    2495K1300000
    4
    2495K1400000

    Floor Drain Trap Seals

    Image of Product. Front orientation. Floor Drain Trap Seals.
    Stop sewer gases from escaping through your floor drain if the P-trap dries out. Similar to a check valve, they allow liquid to drain but won’t let gases back up. They’re especially useful in infrequently used drains. To install, remove the strainer from your drain and place these seals in the opening. They have fins that grip the inside of the drain and a top ring to keep them in place. After putting the strainer back, pour water through the drain to fill the P-trap.
    For Pipe
    Size
    ID
    OD
    Overall
    Ht.
    Each
    Plastic/Rubber
    2
    1 1/8"2 1/8"2"6344N11000000
    3
    2 1/4"3 1/8"2 1/2"6344N1200000
    3 1/2
    2 5/8"3 3/4"2 5/8"6344N1300000
    4
    3"4 1/8"2 3/4"6344N1400000
     

    Brass and Bronze Threaded Cleanout Plugs

    Image of Product. Raised. Front orientation. Pipe and Fittings. Brass and Bronze Threaded Cleanout Plugs.

    Raised

    Image of Product. Recessed. Front orientation. Pipe and Fittings. Brass and Bronze Threaded Cleanout Plugs.

    Recessed

    Close off your drain cleanout pipe with these threaded plugs. Note: If you do not know your pipe size, measure the OD of your existing cleanout plug or the ID of your cleanout fitting and match to the value listed.
    To prevent leaks in threaded connections, apply a sealant to the male threads. Threaded connections can be taken apart as needed for maintenance and repair. For metal threads, use PTFE tape. For plastic threads, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
    Recessed
    Cleanout Plug
    OD/Fitting ID
    For Pipe
    Size
    Thread
    Type
    Material
    Each
    1 7/8"1 1/2
    NPT
    Brass2400K5200000
    2 3/8"2
    NPT
    Brass2400K530000
    3 15/32"3
    NPT
    Brass2400K550000
    3 31/32"3 1/2
    NPT
    Brass2400K5600000
    4 15/32"4
    NPT
    Brass2400K5700000
    5 17/32"5
    NPT
    Brass2400K5900000
    6"NPT
    Brass2400K6100000
    6 19/32"6
    NPT
    Brass2400K6200000
    Plug Wrenches

    Floor Drain Cleanouts

    Image of Product. Bottom orientation. Drain Cleanouts. Floor Drain Cleanouts.
    Create an access point to inspect and clean a floor drain pipeline. The cover on these cleanouts can be adjusted up or down to sit flush with the finished floor. An ABS cleanout plug underneath the cover prevents debris from entering and sewer gases from exiting the system. These cleanouts are compatible with Schedule 40 PVC pipe for gravity-flow drain, waste, and vent applications. Attach to your unthreaded drain pipe with a PVC primer and cement (also known as solvent weld).
    Material
    Pipe
    Size
    Dia.
    Ht.
    Wt. Cap.,
    lb.
    Cover
    Body
    Plug
    Each
    Female Cement Socket
    2
    5 3/16"2 5/8" to 3 1/2"2,000Textured NickelPVC
    ABS
    6139N11000000
    3
    5 3/16"3 7/8" to 4 3/4"2,000Textured NickelPVC
    ABS
    6139N1200000
    4
    5 3/16"4 5/16" to 5 3/16"2,000Textured NickelPVC
    ABS
    6139N1300000
     

    Flame-Retardant Drain, Waste, and Vent Polypropylene Pipe Fittings for Chemicals

    Made of polypropylene, these gravity-flow fittings withstand organic solvents, such as acetone, that would dissolve CPVC pipe. They also stand up to highly corrosive acids, such as hydrochloric acid, and alkalies. All meet UL and ASTM standards for flame retardance and self-extinguishment in the case of fire. They also meet strict ASTM specifications and testing requirements for material quality and product dimensions. They’re compatible with Orion Blueline No-Hub and Orion Rionfuse chemical waste pipe and pipe fittings.
    Either a clamp connector or electrofusion connector is required to connect grooved ends on adapters to pipe or to another fitting with a grooved end. Clamp connectors can be easily taken apart as needed for maintenance. Grooving tools (sold separately) prepare ungrooved ends for clamping. Electrofusion connectors create a stronger, more permanent connection than clamp connectors. Use electrofusion tools (sold separately) to weld these fittings in place.
    Warning: Never use plastic pipe fittings, flanges, and pipe with compressed air or gas.
    External-Square-Drive Plugs/Straight Adapters
    Image of Product. Electrofusion Socket/Grooved-End Clamp-On Male. Bottom orientation. Pipe and Fittings. Flame-Retardant Drain, Waste, and Vent Polypropylene Pipe Fittings for Chemicals, External-Square-Drive Plugs/Straight Adapters, Electrofusion Socket/Grooved-End Clamp-On Male, Hex Body.

    Electrofusion

    Socket/Grooved-End

    Clamp-On Male

    Adapters with a threaded pipe end connect and disconnect easily on that side, no clamp or welding required. Thread sealant tape (sold separately) prevents leaks in threaded connections. To prevent overtightening that could cause cracks and leaks, first finger-tighten fittings, then turn once or twice with a wrench.
    Pipe
    Size
    Body
    Shape
    Material
    Color
    Max. Pressure
    @ Temp.
    Flammability Rating
    Each
    Electrofusion Socket/Grooved-End Clamp-On Male
    1 1/2
    HexPolypropyleneBlueNot RatedASTM D635, UL 94 V-25389N202000000
    2
    HexPolypropyleneBlueNot RatedASTM D635, UL 94 V-25389N20300000
    3
    HexPolypropyleneBlueNot RatedASTM D635, UL 94 V-25389N205000000
    4
    HexPolypropyleneBlueNot RatedASTM D635, UL 94 V-25389N206000000
     
    270° Bend Connectors
    Image of Product. Bottom orientation. Pipe Traps. Flame-Retardant Drain, Waste, and Vent Polypropylene Pipe Fittings for Chemicals, 270° Bend.

    270° Bend

    270° Bend Connectors—270° bend fittings are also known as P-traps.
    Pipe
    Size
    Material
    Color
    Max. Pressure
    @ Temp.
    Flammability Rating
    Fitting
    Type
    Each
    Electrofusion Socket/Grooved-End Clamp-On Male
    1 1/2
    PolypropyleneBlueNot RatedASTM D635, UL 94 V-2270° Bend5389N1020000000
    2
    PolypropyleneBlueNot RatedASTM D635, UL 94 V-2270° Bend5389N103000000
     
    Union 270° Bend Connectors
    Image of Product. Bottom orientation. Pipe Traps. Flame-Retardant Drain, Waste, and Vent Polypropylene Pipe Fittings for Chemicals, Union 270° Bend.

    Union 270° Bend

    Union 270° Bend Connectors—270° bend fittings are also known as P-traps. They separate into three pieces, so you can access your line.
    Pipe
    Size
    Material
    Color
    Max. Pressure
    @ Temp.
    Flammability Rating
    Fitting Type
    Each
    Electrofusion Socket/Grooved-End Clamp On Male
    1 1/2
    PolypropyleneBlueNot RatedASTM D635, UL 94 V-2Union 270° Bend5389N3020000000
    2
    PolypropyleneBlueNot RatedASTM D635, UL 94 V-2Union 270° Bend5389N303000000
     

    Drain Cleanout Hole Covers

    Allow easy access to cleanout plugs hidden behind walls and floors. Covers come with the bolts you need to hold them in place.
    Covers for Floor Cleanouts
    Image of Product. Front orientation. Drain Cleanout Hole Covers. Covers for Floor Cleanouts, 1 Hole.

    1 Hole

    No. of
    Holes
    Dia.
    Thk.
    Material
    Wt. Cap.,
    lb.
    Mounting Fasteners
    Included
    Bolt
    Lg.
    Each
    15 1/8"3/16"Nickel2,400Yes1 1/2"2043K420000000
    16 1/8"1/4"Nickel2,400Yes1 1/2"2043K45000000
    18 3/8"1/4"Nickel2,400Yes1 1/2"2043K46000000
    back to top