    74 Products

    Fixed-Set-Point Flow Switches

    Image of Product. Style C. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style C.

    Style C

    Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They’re accurate in any mounting position.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    Straight
    Image of Product. Style C. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style C.

    Style C

    316 Stainless Steel Fitting—Bronze and 316 stainless steel fittings resist impact better than plastic fittings.
    SPDT—SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or from on to off (normally closed).
    Conduit
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Mounting
    Position
    Each
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    SPDT
    C1
    NPT
    Female0.50.075400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T261000000000
    C1
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T26200000000
    C1
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T26300000000
    C1
    NPT
    Female60.9400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T26400000000
    C1
    NPT
    Female81.2400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T26500000000
    C2
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle6486T29100000000
    C2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle6486T29200000000
    C2
    NPT
    Female507.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle6486T29500000000
     

    Flow Switches with Sight

    Image of Product. Front orientation. Flow Switches with Sight.
    For monitoring flow at a glance, these switches have a plastic window with a rotor indicator that spins when there’s flow. They activate or deactivate equipment when the flow rate reaches your set point. Tighten or loosen the adjustment screw to choose your set point anywhere within the range. To measure flow, they count how many times the turbine turns as liquid flows through. Use them only with clean, low-viscosity liquids to prevent clogging the turbine and other damage. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed).
    These switches are calibrated with water. They can also be used with other liquids but may not measure accurately if their viscosity is significantly different.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    316 Stainless Steel Fitting—Brass and 316 stainless steel fittings resist impact better than polypropylene fittings.
    Any-Angle Mount—Flow switches with any-angle mounting position will measure accurately no matter how you orient them in your system.
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Mounting
    Position
    End-to-End
    Lg.
    Certification
    Each
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1/2 NPT Female
    0.25 to 2.5200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal3 3/4"CE Marked
    VDE Certified
    4138K1050000000
    0.5 to 5200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal3 3/4"CE Marked
    VDE Certified
    4138K106000000
    1 to 10200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal3 3/4"CE Marked
    VDE Certified
    4138K107000000
    1.5 to 15200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal3 3/4"CE Marked
    VDE Certified
    4138K108000000
    1.5 to 20200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3"CE Marked
    UL Recognized Component
    4138K18000000
     
    3/4 NPT Female
    1.5 to 15200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal5 1/4"CE Marked
    VDE Certified
    4138K109000000
    5 to 30200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3 15/16"CE Marked
    UL Recognized Component
    4138K19000000
    5 to 50200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal5 1/4"CE Marked
    VDE Certified
    4138K111000000
     
    1 NPT Female
    1.5 to 15200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal5 1/4"CE Marked
    VDE Certified
    4138K112000000
    3 to 30200 psi @ 70° F20 to 2255 amp @ 120V AC
    5 amp @ 240V AC
    Horizontal5 1/4"CE Marked
    VDE Certified
    4138K113000000
    8 to 60200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3 15/16"CE Marked
    UL Recognized Component
    4138K21000000
     

    Insertion-Mount Flow Switches

    Image of Product. Threaded Connection. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection.

    Threaded Connection

    Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. They are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They should be mounted vertically into a large-diameter horizontal pipeline, so liquid pushes the paddle.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    316 Stainless Steel Body—Switches with a brass or 316 stainless steel body have multiple paddles you can choose between to get you closest to your set point. For a higher set point, loosen the locking washers to remove the largest paddles. You can also trim the paddles to fine-tune your set point. The more you trim, the higher the set point.
    316 Stainless Steel Fitting—Brass and 316 stainless steel fittings resist impact better than Noryl fittings.
    For Pipe
    Size
    Flow Set Point Range, gpm
    Max. Flow Rate, gpm
    Paddle Material
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Body
    Ht.
    Certification
    Each
    316 Stainless Steel Body with 1 NPT Male Threaded 316 Stainless Steel Fittings
     
    Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles
    1
    2
    4
    6
    6 to 10.2
    18.8 to 32.8
    39.7 to 73.5
    79.2 to 166
    27, 105, 397, 900304 Stainless Steel
    160 psi @ 70° F33 to 3003.7 amp @ 240V AC
    7.4 amp @ 120V AC
    5"C-UL Listed
    UL Listed
    4971K40000000
     

    Hazardous-Location Insertion-Mount Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. Hazardous-Location Insertion-Mount Flow Switches.
    Safely activate and deactivate equipment in environments with flammable gases and combustible dust when your flow rate reaches a set point. They are UL listed and CSA certified for use in hazardous locations. These switches save you from disassembling your pipeline because you insert them into pipe tees or pipe outlets instead of mounting them inline. They actuate when your system’s liquid pushes the paddle into a set position. To change your set point, the paddle has multiple layers that you can remove. For the lowest set point, use the largest paddle that will fit your pipe. To increase your set point, loosen the locking washers and remove paddles. You can trim the paddles to fine-tune your set point. The smaller the paddle, the higher the setpoint.
    They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    SPDT—SPDT (singe pole, double throw) switches can turn one device from off to on (normally open) or from on to off (normally closed).
    DPDT—DPDT (double pole, double throw) switches can either turn two devices from off to on (normally open) or on to off (normally closed).
    Flow Set Point Range
    Max. Flow Rate
    Conduit
    Pipe
    Size
    Thread
    Type
    Gender
    For Pipe
    Size
    For Water and Oil
    For Air and Inert Gas
    For Water
    and Oil
    For Air and
    Inert Gas
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Body
    Ht.
    Each
    SPDT
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K55000000000
     
    DPDT
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K5600000000
     

    Flow Transmitters with Sight

    Image of Product. Front orientation. Flow Transmitters. Flow Transmitters with Sight.
    Send flow rate data using these transmitters while also being able to visually confirm liquid is flowing. They measure flow by counting how many times the turbine turns as the liquid moves through it. To prevent clogging the turbine and other damage, use them only with clean, low-viscosity liquids. These transmitters, also known as transducers, convert the flow measurement to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs), to monitor flow or control equipment. Mount them directly inline with your system. They measure accurately in any mounting orientation.
    These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Analog Transmitter Output—Transmitters with an analog output increase their output signal as flow increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range.
    Digital Pulse Output—Transmitters with a digital pulse output send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Pulse Freq.,
    Hz
    Pulse Frequency per
    Volume, pulse per gal.
    Each
    One 4-20 mA Analog Transmitter Output—Wire Lead Connection
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Turbine1/2 NPT Female0.25 to 2.53 11/16"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K191000000000
    Turbine1/2 NPT Female0.5 to 53 11/16"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K19200000000
    Turbine1/2 NPT Female1.5 to 153 11/16"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K19300000000
    Turbine3/4 NPT Female1.5 to 155 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K20100000000
    Turbine3/4 NPT Female5 to 505 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K20200000000
    Turbine1 NPT Female1.5 to 155 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K21100000000
    Turbine1 NPT Female5 to 505 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K21200000000
     
    One 0-5V DC Analog Transmitter Output—Wire Lead Connection
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Turbine1/2 NPT Female0.25 to 2.53 11/16"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K161000000
    Turbine1/2 NPT Female0.5 to 53 11/16"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K162000000
    Turbine1/2 NPT Female1.5 to 153 11/16"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K163000000
    Turbine3/4 NPT Female1.5 to 155 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K17100000000
    Turbine3/4 NPT Female5 to 505 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K17200000000
    Turbine1 NPT Female1.5 to 155 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K18100000000
    Turbine1 NPT Female5 to 505 1/4"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo9687K18200000000
     
    One Digital Pulse Output—Wire Lead Connection
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Turbine1/2 NPT Female0.25 to 2.53 11/16"±2%200 psi @ 70° F20 to 212Buna-N
    12 to 24Any AngleNo2009687K151000000
    Turbine1/2 NPT Female1.5 to 203"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K32000000
    Turbine3/4 NPT Female5 to 303 15/16"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K33000000
    Turbine1 NPT Female8 to 603 15/16"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K34000000
     

    Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Variable Area Flow Measurement.

    Variable Area Flow

    Measurement

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Vortex Flow Measurement.

    Vortex Flow

    Measurement

    Send flow rate and temperature measurements simultaneously to a programmable logic controller (PLC), data logger, or other receiving device. Used to monitor status or control equipment, these transmitters, also known as transducers, convert measurements to an electrical signal that is interpreted by receiving devices. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them inline with your pipe system. They’ll measure flow correctly in any mounting orientation.
    A digital display makes it easy to view readings and adjust settings at the source. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    Variable Area Flow Measurement—Variable-area transmitters determine the flow rate by tracking where the liquid pushes the piston. They have two configurable outputs. One can be wired as an analog output or a digital switch. The other one can be wired as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. These transmitters are calibrated with water, glycol solutions, and coolants but can be recalibrated in the field for other liquids.
    Vortex Flow Measurement—Vortex transmitters determine the flow rate by measuring the size of the vortex created as liquid flows through them. They don’t have any moving parts that can break or get stuck. Use them only with liquids that are at least 95% water. They have one analog output for flow and another for temperature. The output for temperature can also be wired for IO Link.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gph
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch Output—4-Pole M12 Connection Plug
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Variable Area3/4 NPT Female5 to 2405 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N110000000
    Variable Area3/4 NPT Female7 to 3605 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N12000000
    Variable Area3/4 NPT Female10 to 6005 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N13000000
    Variable Area1 NPT Female30 to 1,6205 3/4"±5%362 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N14000000
    Variable Area1 1/2 NPT Female60 to 3,0006 3/16"±5%362 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N15000000
     
    Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Vortex1/2 NPT Female16 to 3174 11/16"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4401N16000000
    Vortex1/2 NPT Female32 to 6344 11/16"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4401N17000000
    Vortex3/4 NPT Female80 to 1,5855 15/32"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4401N18000000
     

    Fixed-Set-Point High-Pressure Flow Switches

    Quicker to install than adjustable flow switches in high-pressure lines, these switches come factory-set to activate or deactivate equipment at a specific level. They compensate for the viscosity and density changes of liquid. As flowing liquid pushes an internal piston, the switch reads the piston's position to measure the flow. When the piston passes the set point, the switch actuates. All measure flow correctly no matter their mounting position.
    These switches are calibrated with water. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new setpoint.
    Straight
    Image of Product. Front orientation. Straight. Fixed-Set-Point High-Pressure Flow Switches.
    SPST—SPST (single pole, single throw) switches turn one device from off to on (normally open).
    Pipe
    Connections
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    End-to-End
    Lg.
    Each
    SPST
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
    3/8 NPT Male0.250.051,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K710000000
    3/8 NPT Male0.50.11,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K72000000
    3/8 NPT Male20.41,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K75000000
     

    Sanitary Electronic Insertion-Mount Flow Switches

    Image of Product. Front orientation. Flow Switches. Sanitary Electronic Insertion-Mount Flow Switches.
    Easy to clean and install, these flow switches are 3-A certified to meet sanitary design standards and insert into your line with a quick-clamp mounting adapter (sold separately). They have a smooth probe, and unlike flow switches that measure with a paddle or turbine, these don’t have moving parts for contaminants to get stuck in. Rated IP67 and IP69K, they withstand temporary submersion and high-temperature, high-pressure washdowns. The mounting adapter attaches to a quick-clamp tube tee or outlet (often called tri-clamp fittings) in your large-diameter tubing system using a gasket and clamp (not included), so you don't need to disassemble your line for inline installation. This mounting adapter is also easy to remove and clean.
    They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. They’re accurate in any mounting position.
    Flow Set Point
    13/16"
    Probe Length
    1 13/16"
    Probe Length
    For Tube
    OD
    For Liquids, gpm
    For Gas, scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Food Industry Std.
    Each
    Each
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1 Digital PNP Signal Output
    1 1/2"
    2"
    0.55 to 54.21
    0.97 to 96.37
    4.84 to 72.47
    8.59 to 128.84
    430 psi @ 70° F-10 to 20036250 mA @ 19V DC
    250 mA @ 36V DC
    3 5/16"IP67, IP69K
    C-UL Listed
    UL Listed
    CE Marked
    3-A Certified 74-07, FDA Compliant 21 CFR 177.2415
    4548N1100000004548N120000000
     
    Mounting Adapters

    High-Accuracy Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. High-Accuracy Flow and Temperature Transmitters.
    Also known as magmeters, these transmitters use a magnetic field to measure flow rate and temperature with high accuracy. Because they use a magnetic field, they only work with conductive liquids, such as water. These transmitters, also known as transducers, convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. As flow or temperature increases, the output signal increases. These transmitters have one analog output for flow and another for temperature. They only give accurate readings within the rated measurement range. A digital display makes it easy to view readings and adjust settings at the source. Mount these transmitters inline with your pipe system. They measure flow correctly in any mounting orientation.
    These transmitters are calibrated with water. They can only be used with liquids with a conductivity of at least 20 µS/cm.
    Flow Range
    Flow Measurement
    Type
    Pipe
    Connections
    Gallons per
    Minute, gpm
    Liters per
    Minute, L/min
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs
     
    316 Stainless Steel/Plastic/Polybutylene Body with 316 Stainless Steel Fitting
    Magnetic Induction1/2 NPT Female0.03 to 6.60.1 to 252 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N1010000000
    Magnetic Induction3/4 NPT Female0.02 to 13.220.2 to 502 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N102000000
    Magnetic Induction1 NPT Female0.1 to 26.40.2 to 1002 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N103000000
    Magnetic Induction1 1/2 NPT Female1.3 to 79.35 to 3006 11/16"±0.8%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP65, IP67
    4397N10400000000
    Magnetic Induction2 NPT Female1.3 to 158.55 to 6007 1/16"±0.8%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP65, IP67
    4397N10500000000
     

    Build-Your-Own Flanged Pipe Flow Transmitters

    Image of System. Components Sold Separately (Pipe Flanges Not Included). Front orientation. Contains Annotated. Flow Transmitters. Build-Your-Own Flanged Pipe Flow Transmitters.

    Components Sold Separately (Pipe Flanges

    Not Included)

    Install these transmitters between two flanges in a flanged pipe system to measure flow rate and send the data to a remote display or programmable logic controller (PLC). For easy cleaning and maintenance, you can slide the transmitter out from between the flanges. A complete transmitter consists of a flow transmitter, display, and mounting hardware kit (all components sold separately). Flowing liquid turns the turbine in the transmitter, while the easy-to-read display counts the number of turns to measure and transmit the flow. The display also shows total and batch flow volumes. Use these transmitters with clean, low-viscosity liquids to avoid clogging or other damage to the internal parts. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    Also known as transducers, these transmitters help you monitor status or control equipment by converting measurements to a digital pulse that can be interpreted by receiving devices. Each pulse is a spike of voltage. The higher the flow, the more pulses they send. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the measurement range and output signal of the transmitter. Transmitters will only provide accurate readings within the rated measurement range.
    The transmitters are calibrated with water but can be used with other liquids.
    Flow Transmitters
    Image of Product. Front orientation. Flow Transmitters. Build-Your-Own Flanged Pipe Flow Transmitters, Flow Transmitters.
    Flange
    Flow Measurement
    Type
    Pipe
    Size
    Flow Range,
    gpm
    Bore
    Size
    OD
    Type
    For Flange
    ANSI Class
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Mounting
    Position
    Field
    Recalibratable
    Pulse Frequency per
    Volume, pulse per gal.
    Each
    One Digital Pulse Output—2-Pin BNC Connection Plug
     
    316/316L Stainless Steel Body with 316/316L Stainless Steel Fitting
    Turbine1
    3 to 307/8"2"Round150
    4"±1.0%285 psi @ 70° F-150 to 350Any AngleNo3,1004408N110000000
    Turbine2
    5 to 501"3 5/8"Round150
    2 1/2"±1.0%285 psi @ 70° F-150 to 350Any AngleNo8504408N1200000000
    Turbine2
    15 to 1801 1/2"3 5/8"Round150
    2 1/2"±1.0%285 psi @ 70° F-150 to 350Any AngleNo3254408N1300000000
    Turbine3
    60 to 6003"5"Round150
    4 1/4"±1.0%285 psi @ 70° F-150 to 350Any AngleNo504408N1400000000
     
    Flow Transmitter Repair Kits

    Insertion-Mount Flow and Temperature Transmitters

    Image of ProductInUse. Front orientation. Flow Transmitters. Insertion-Mount Flow and Temperature Transmitters.
    Image of Product. Top orientation. Flow Transmitters. Insertion-Mount Flow and Temperature Transmitters.
    Thread mounting hardware (sold separately) into your pipe connection and insert the probe of these transmitters to measure the flow and temperature of water, oil, or air. The probe is held in place with a compression fitting on the other end of the mounting hardware. They’re often used in large-diameter pipes where it would be difficult to install a transmitter inline. To calculate the flow rate, these transmitters generate a small amount of heat, then measure the cooling effect your liquid or air has on it. They measure and output both flow and temperature, making them ideal for applications where temperature fluctuates. Also known as transducers, they convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. They’ll measure flow correctly in any mounting orientation. These transmitters are calibrated with air, glycol solutions, oil, and water but can be recalibrated in the field for other liquids.
    Adjust settings at the source using the digital display. These transmitters have two configurable outputs. One can be wired for flow or temperature as an analog output or a digital switch. The other one can be wired for flow as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. To change settings and receive error messages remotely from your PLC or computer, you can program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    Flow Measurement
    Type
    Flow Range,
    gpm
    Probe
    Lg.
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug
     
    316 Stainless Steel/Polybutylene Body with 316 Stainless Steel Fitting
    Thermal0.02 to 123 15/16"7 9/16"±10%725 psi @ 212° F0 to 21218 to 30Any AngleYesIP65, IP67
    4426N1010000000
    Thermal0.02 to 127 7/8"11 1/2"±10%725 psi @ 212° F0 to 21218 to 30Any AngleYesIP65, IP67
    4426N102000000
     
    Flow Transmitter Mounting Hardware

    Ultra-Low-Flow Flow Transmitters

    Image of Product. Front orientation. Flow Transmitters. Ultra-Low-Flow Flow Transmitters.
    Often used in low-flow metering applications for lubricants or antifreeze, these transmitters measure flow rate and send the data to a remote display or programmable logic controller (PLC). To measure flow, they have oval-shaped gears that move the liquid through the flowmeter—how fast the gears turn correspond to the flow rate. Also known as transducers, they help you monitor status or control equipment by converting measurements to an electrical pulse that can be interpreted by receiving devices. The higher the flow, the more pulses they send. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    These transmitters are calibrated with oil but can be used with other liquids and will generally measure accurately, even if they differ in viscosity and density.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    ml/min
    Accuracy
    Overall
    Ht.
    Dia.
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Pulse Frequency per
    Volume, pulse per ml
    Each
    One Digital Pulse Output—Wire Lead Connection
     
    316 Stainless Steel Body
    Positive Displacement1/8 NPT Female3 to 300±0.5%2 7/8"1 1/2"1,450 psi @ 70° F-22 to 176Viton® Fluoroelastomer
    4 to 26Any AngleNo94126K73000000000
    Positive Displacement1/8 NPT Female10 to 1,000±0.5%2 7/8"1 15/16"1,450 psi @ 70° F-22 to 176Viton® Fluoroelastomer
    4 to 26Any AngleNo44126K7400000000
     