McMaster-Carr logo
    Filter by
    For Use With
    Calibrated With
    Fitting Connection
    Switch Designation
    Industrial Info Compare
    Mounting Location
    Mounting Position
    DFARS Specialty Metals
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    90 Products

    Fixed-Set-Point Flow Switches

    Image of Product. Style A. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style A.
    Image of Product. Style B. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style B.
    Image of Product. Style C. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style C.

    Style A

    Style B

    Style C

    Image of Product. Style D. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style D.
    Image of Product. Style E. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style E.

    Style D

    Style E

    Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They’re accurate in any mounting position.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    Straight
    Image of Product. Style A. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style A.
    Image of Product. Style B. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style B.
    Image of Product. Style C. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches, Straight, Style C.

    Style A

    Style B

    Style C

    316 Stainless Steel Fitting and Bronze Fitting—Bronze and 316 stainless steel fittings resist impact better than plastic fittings.
    Polypropylene Fitting—Polypropylene and PPS fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    SPDT—SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or from on to off (normally closed).
    SPST—SPST (single pole, single throw) switches turn one device from off to on (normally open).
    Conduit
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Mounting
    Position
    Each
    Polypropylene Body with Polypropylene Fittings
     
    SPST
    A1/4
    NPT
    Female0.10.1200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    4 7/8"Any Angle2371K41000000
    A1/4
    NPT
    Female0.250.25200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    4 7/8"Any Angle2371K4200000
    A1/4
    NPT
    Female0.50.5200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    4 7/8"Any Angle2371K4300000
    A1/4
    NPT
    Female0.750.75200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    4 7/8"Any Angle2371K4400000
    A1/4
    NPT
    Female11200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    4 7/8"Any Angle2371K4500000
    B3/8
    NPT
    Male0.250.05125 psi @ 70° F33 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    4"Any Angle42015K2100000
    B3/8
    NPT
    Male0.50.1125 psi @ 70° F33 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    4"Any Angle42015K2200000
    B3/8
    NPT
    Male10.2125 psi @ 70° F33 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    4"Any Angle42015K2300000
    B3/8
    NPT
    Male1.50.3125 psi @ 70° F33 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    4"Any Angle42015K2400000
    B3/8
    NPT
    Male20.4125 psi @ 70° F33 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    4"Any Angle42015K2500000
     
    Bronze Body with Bronze Fittings
     
    SPDT
    C1
    NPT
    Female0.50.075400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T211000000
    C1
    NPT
    Female10.15300 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 3/8"Any Angle4553N11000000
    C1
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T212000000
    C1
    NPT
    Female30.45400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 3/8"Any Angle4553N12000000
    C1
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T213000000
    C1
    NPT
    Female60.9400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T214000000
    C1
    NPT
    Female81.2400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T215000000
    C1 1/4
    NPT
    Female10.15400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4"Any Angle6486T231000000
    C1 1/4
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4"Any Angle6486T232000000
    C1 1/4
    NPT
    Female203400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4"Any Angle6486T235000000
    C1 1/2
    NPT
    Female1.50.225400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4 1/2"Any Angle6486T241000000
    C1 1/2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4 1/2"Any Angle6486T242000000
    C1 1/2
    NPT
    Female304.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male4 1/2"Any Angle6486T245000000
    C2
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle6486T251000000
    C2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle6486T252000000
    C2
    NPT
    Female507.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle6486T255000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    SPDT
    C1
    NPT
    Female0.50.075400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T26100000000
    C1
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T26200000000
    C1
    NPT
    Female40.6400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T26300000000
    C1
    NPT
    Female60.9400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T26400000000
    C1
    NPT
    Female81.2400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male3 1/4"Any Angle6486T26500000000
    C2
    NPT
    Female20.3400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle6486T29100000000
    C2
    NPT
    Female50.75400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle6486T29200000000
    C2
    NPT
    Female507.5400 psi @ 70° F-20 to 300400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    1/2
    NPT
    Male5 3/8"Any Angle6486T29500000000
     
    90° Elbow
    Image of Product. Style D. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style D.
    Image of Product. Style E. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Flow Switches, 90° Elbow, Style E.

    Style D

    Style E

    Polypropylene Fitting and PPS Fitting—Polypropylene and PPS fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    SPDT—SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or from on to off (normally closed).
    SPST—SPST (single pole, single throw) switches turn one device from off to on (normally open).
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Mounting
    Position
    Each
    Polypropylene Body with Polypropylene Fittings
     
    SPST
    D1/4
    NPT
    Female0.0420.006200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    Any Angle4553N15000000
    D1/4
    NPT
    Female0.10.1200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    Any Angle2371K2100000
    D1/4
    NPT
    Female0.250.25200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    Any Angle2371K2200000
    D1/4
    NPT
    Female0.50.5200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    Any Angle2371K2300000
    D1/4
    NPT
    Female0.750.75200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    Any Angle2371K2400000
    D1/4
    NPT
    Female11200 psi @ 70° F33 to 194500 mA @ 300V AC
    700 mA @ 350V DC
    Any Angle2371K2500000
    E3/4
    NPT
    Female0.250.05100 psi @ 70° F0 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle4553N13000000
    E3/4
    NPT
    Female0.50.1100 psi @ 70° F0 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle42015K6000000
    E3/4
    NPT
    Female10.2100 psi @ 70° F0 to 212400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle4553N14000000
     
    PPS Body with PPS Fittings
     
    SPDT
    D1/4
    NPT
    Female0.10.02250 psi @ 70° F0 to 225400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle42015K41000000
    D1/4
    NPT
    Female0.250.05250 psi @ 70° F0 to 225400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle42015K42000000
    D1/4
    NPT
    Female10.2250 psi @ 70° F0 to 225400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle42015K45000000
    D1/4
    NPT
    Female1.50.3250 psi @ 70° F0 to 225400 mA @ 30V AC
    170 mA @ 120V AC
    80 mA @ 240V AC
    300 mA @ 30V DC
    130 mA @ 120V DC
    60 mA @ 240V DC
    Any Angle42015K46000000
     

    Fixed-Set-Point High-Pressure Flow Switches

    Quicker to install than adjustable flow switches in high-pressure lines, these switches come factory-set to activate or deactivate equipment at a specific level. They compensate for the viscosity and density changes of liquid. As flowing liquid pushes an internal piston, the switch reads the piston's position to measure the flow. When the piston passes the set point, the switch actuates. All measure flow correctly no matter their mounting position.
    These switches are calibrated with water. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new setpoint.
    Straight
    Image of Product. Front orientation. Straight. Fixed-Set-Point High-Pressure Flow Switches.
    SPST—SPST (single pole, single throw) switches turn one device from off to on (normally open).
    Pipe
    Connections
    Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    End-to-End
    Lg.
    Each
    SPST
     
    Brass Body with Brass Fittings
    3/8 NPT Male0.250.051,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K510000000
    3/8 NPT Male0.50.11,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K52000000
    3/8 NPT Male10.21,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K53000000
    3/8 NPT Male1.50.31,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K54000000
    3/8 NPT Male20.41,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K55000000
    1/2 NPT Male0.250.051,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    4"4960K61000000
    1/2 NPT Male0.50.11,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    4"4960K62000000
    1/2 NPT Male10.21,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    4"4960K63000000
    1/2 NPT Male1.50.31,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    4"4960K64000000
    1/2 NPT Male20.41,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    4"4960K65000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
    3/8 NPT Male0.250.051,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K71000000
    3/8 NPT Male0.50.11,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K72000000
    3/8 NPT Male20.41,500 psi @ 70° F-20 to 2750.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    3 7/16"4960K75000000
     
    90° Elbow
    Image of Product. Front orientation. Contains Annotated. 90° Elbow. Fixed-Set-Point High-Pressure Flow Switches.
    SPDT—SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or from on to off (normally closed).
    Approx. Difference Between Set
    Point and Reset Point
    Conduit
    Pipe
    Connections
    Set Point,
    gpm
    For Liquids,
    gpm
    For Gas,
    scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Port-to-Port
    Lg.
    Each
    SPDT
     
    Brass Body with Brass Fittings
    1/4 NPT Female0.0130.01950.031,000 psi @ 70° F-20 to 2250.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    1/2
    NPT
    Female2 1/16"4960K810000000
    1/4 NPT Female0.10.0150.011,000 psi @ 70° F-20 to 2250.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    1/2
    NPT
    Female2 1/16"4960K21000000
    1/4 NPT Female0.250.03750.011,000 psi @ 70° F-20 to 2250.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    1/2
    NPT
    Female2 1/16"4960K22000000
    1/4 NPT Female0.50.0750.011,000 psi @ 70° F-20 to 2250.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    1/2
    NPT
    Female2 1/16"4960K23000000
    1/4 NPT Female0.750.11250.021,000 psi @ 70° F-20 to 2250.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    1/2
    NPT
    Female2 1/16"4960K24000000
    1/4 NPT Female10.150.021,000 psi @ 70° F-20 to 2250.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    1/2
    NPT
    Female2 1/16"4960K25000000
    1/4 NPT Female1.50.2250.031,000 psi @ 70° F-20 to 2250.4 amp @ 30V AC
    0.17 amp @ 120V AC
    0.08 amp @ 240V AC
    0.3 amp @ 30V DC
    0.13 amp @ 120V DC
    0.06 amp @ 240V DC
    1/2
    NPT
    Female2 1/16"4960K26000000
     

    Insertion-Mount Flow Switches

    Image of Product. Threaded Connection with NEMA 4X Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection, NEMA 4X Enclosure Rating.

    Threaded

    Connection with

    NEMA 4X Rating

    Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. They are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They should be mounted vertically into a large-diameter horizontal pipeline, so liquid pushes the paddle.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Brass Body—Switches with a brass or 316 stainless steel body have multiple paddles you can choose between to get you closest to your set point. For a higher set point, loosen the locking washers to remove the largest paddles. You can also trim the paddles to fine-tune your set point. The more you trim, the higher the set point.
    Brass Fitting—Brass and 316 stainless steel fittings resist impact better than Noryl fittings.
    NEMA 4X Enclosure Rating—NEMA 4X rated switches protect against dust, weather, and washdowns.
    For Pipe
    Size
    Flow Set Point Range, gpm
    Max. Flow Rate, gpm
    Paddle Material
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Brass Body with 1 NPT Male Threaded Brass Fittings
     
    Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles
    1
    2
    4
    6
    4.9 to 17.6
    13.7 to 56.4
    35.3 to 118
    60.3 to 245
    27, 105, 397, 900304 Stainless Steel
    160 psi @ 70° F33 to 2253.7 amp @ 240V AC
    7.4 amp @ 120V AC
    5"NEMA 4X
    C-UL Listed
    UL Recognized Component
    4971K50000000
     

    Flow Switches with Sight

    Image of Product. Front orientation. Flow Switches with Sight.
    For monitoring flow at a glance, these switches have a plastic window with a rotor indicator that spins when there’s flow. They activate or deactivate equipment when the flow rate reaches your set point. Tighten or loosen the adjustment screw to choose your set point anywhere within the range. To measure flow, they count how many times the turbine turns as liquid flows through. Use them only with clean, low-viscosity liquids to prevent clogging the turbine and other damage. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed).
    These switches are calibrated with water. They can also be used with other liquids but may not measure accurately if their viscosity is significantly different.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    316 Stainless Steel Fitting and Brass Fitting—Brass and 316 stainless steel fittings resist impact better than polypropylene fittings.
    Polypropylene Fitting—Polypropylene fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Any-Angle Mount—Flow switches with any-angle mounting position will measure accurately no matter how you orient them in your system.
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Mounting
    Position
    End-to-End
    Lg.
    Certification
    Each
    Polypropylene Body with Polypropylene Fittings
     
    1/4 NPT Female
    0.1 to 5100 psi @ 70° F33 to 18095 mA @ 115V ACAny Angle3 1/16"CE Marked
    UL Recognized Component
    4138K110000000
     
    1/2 NPT Female
    1.5 to 20100 psi @ 70° F33 to 18095 mA @ 115V ACAny Angle3 1/16"CE Marked
    UL Recognized Component
    4138K12000000
     
    Brass Body with Brass Fittings
     
    1/4 NPT Female
    0.1 to 5200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3"CE Marked
    UL Recognized Component
    4138K13000000
     
    1/2 NPT Female
    1.5 to 20200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3"CE Marked
    UL Recognized Component
    4138K14000000
     
    3/4 NPT Female
    5 to 30200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3 15/16"CE Marked
    UL Recognized Component
    4138K15000000
     
    1 NPT Female
    8 to 60200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3 15/16"CE Marked
    UL Recognized Component
    4138K16000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1/2 NPT Female
    1.5 to 20200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3"CE Marked
    UL Recognized Component
    4138K18000000
     
    3/4 NPT Female
    5 to 30200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3 15/16"CE Marked
    UL Recognized Component
    4138K19000000
     
    1 NPT Female
    8 to 60200 psi @ 70° F33 to 21295 mA @ 115V ACAny Angle3 15/16"CE Marked
    UL Recognized Component
    4138K21000000
     

    Flow Transmitters with Sight

    Image of Product. Front orientation. Flow Transmitters. Flow Transmitters with Sight.
    Send flow rate data using these transmitters while also being able to visually confirm liquid is flowing. They measure flow by counting how many times the turbine turns as the liquid moves through it. To prevent clogging the turbine and other damage, use them only with clean, low-viscosity liquids. These transmitters, also known as transducers, convert the flow measurement to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs), to monitor flow or control equipment. Mount them directly inline with your system. They measure accurately in any mounting orientation.
    These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Digital Pulse Output—Transmitters with a digital pulse output send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Pulse Freq.,
    Hz
    Each
    One Digital Pulse Output—Wire Lead Connection
     
    Polypropylene Body with Polypropylene Fitting
    Turbine1/4 NPT Female0.1 to 53 1/16"±7%100 psi @ 70° F33 to 180Fluoroelastomer
    4.25 to 24Any AngleNo15 to 2259687K110000000
    Turbine1/2 NPT Female1.5 to 203 1/16"±15%100 psi @ 70° F33 to 180Fluoroelastomer
    4.25 to 24Any AngleNo15 to 2259687K12000000
     
    Brass Body with Brass Fitting
    Turbine1/4 NPT Female0.1 to 53"±7%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K21000000
    Turbine1/2 NPT Female1.5 to 203"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K22000000
    Turbine1 NPT Female8 to 603 15/16"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K24000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Turbine1/2 NPT Female1.5 to 203"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K32000000
    Turbine3/4 NPT Female5 to 303 15/16"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K33000000
    Turbine1 NPT Female8 to 603 15/16"±15%200 psi @ 70° F33 to 212Fluoroelastomer
    4.5 to 24Any AngleNo15 to 2259687K34000000
     

    High-Accuracy Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. High-Accuracy Flow and Temperature Transmitters.
    Also known as magmeters, these transmitters use a magnetic field to measure flow rate and temperature with high accuracy. Because they use a magnetic field, they only work with conductive liquids, such as water. These transmitters, also known as transducers, convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. As flow or temperature increases, the output signal increases. These transmitters have one analog output for flow and another for temperature. They only give accurate readings within the rated measurement range. A digital display makes it easy to view readings and adjust settings at the source. Mount these transmitters inline with your pipe system. They measure flow correctly in any mounting orientation.
    These transmitters are calibrated with water. They can only be used with liquids with a conductivity of at least 20 µS/cm.
    Flow Range
    Flow Measurement
    Type
    Pipe
    Connections
    Gallons per
    Minute, gpm
    Liters per
    Minute, L/min
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs
     
    316 Stainless Steel/Plastic/Polybutylene Body with 316 Stainless Steel Fitting
    Magnetic Induction1/2 NPT Female0.03 to 6.60.1 to 252 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N1010000000
    Magnetic Induction3/4 NPT Female0.02 to 13.220.2 to 502 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N102000000
    Magnetic Induction1 NPT Female0.1 to 26.40.2 to 1002 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N103000000
    Magnetic Induction1 1/2 NPT Female1.3 to 79.35 to 3006 11/16"±0.8%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP65, IP67
    4397N10400000000
    Magnetic Induction2 NPT Female1.3 to 158.55 to 6007 1/16"±0.8%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP65, IP67
    4397N10500000000
     
    back to top