    12 Products

    Fixed-Set-Point Flow Switches for Drinking Water

    Image of Product. Front orientation. Flow Switches. Fixed-Set-Point Flow Switches for Drinking Water.
    Factory set to activate equipment when your drinking water system reaches a fixed level, these flow switches are easier to install than adjustable flow switches. They meet NSF/ANSI 61, so they're safe to use with drinking water. They actuate when your system’s flowing water pushes their paddle into a set position. These switches are single pole, single throw (SPST) and turn one device from off to on. IP rated, they seal out dust and can be lightly rinsed. They're accurate in any mounting position.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Pipe
    Connections
    Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage
    Max. Switching Current
    @ Voltage
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Food Industry
    Std.
    Each
    Noryl Body with Threaded Brass Fittings
    1/2 NPT Female0.6145 psi @ 70° F-4 to 212230V AC/48V DC1 amp @ 230V AC
    1 amp @ 48V DC
    2"IP65
    CE Marked
    NSF/ANSI 61
    4646N110000000
     

    Flow Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow Transmitters, Turbine Flow Measurement.

    Turbine Flow

    Measurement

    Send flow rate measurements to monitor and control equipment. Also known as transducers, these transmitters convert flow rate measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure flow correctly no matter their mounting orientation.
    These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Turbine Flow Measurement—Turbine transmitters measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. The digital output sends flow data with a pulse, which is a spike of voltage. The higher the flow, the more pulses they send. The voltage of the pulse output matches the input voltage sent to the transmitters. These transmitters meet NSF/ANSI 61 for use with drinking water.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Pulse Freq.,
    Hz
    Each
    One 4-20 mA Analog Transmitter/Digital Pulse Output—Wire Lead Connection
     
    Nylon Body with Nylon Fitting
    Turbine1/4 NPT Male0.026 to 0.651 3/4"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo36 to 9024386N2010000000
    Turbine3/8 NPT Male0.13 to 1.32 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo56 to 5654386N202000000
    Turbine3/8 NPT Male0.26 to 42 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo36 to 5534386N203000000
    Turbine3/8 NPT Male0.53 to 9.22 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo25 to 4354386N204000000
    Turbine3/4 NPT Male1.32 to 17.172 15/16"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo17 to 2274386N205000000
     
    Brass Body with Brass Fitting
    Turbine3/8 NPT Male0.5 to 2.112 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo132 to 5594386N206000000
    Turbine3/8 NPT Male0.8 to 6.62 5/32"±3%362 psi @ 212° F-4 to 2125 to 24Any AngleNo46 to 3834386N207000000
     

    Sanitary Electronic Insertion-Mount Flow Switches

    Image of Product. Front orientation. Flow Switches. Sanitary Electronic Insertion-Mount Flow Switches.
    Easy to clean and install, these flow switches are 3-A certified to meet sanitary design standards and insert into your line with a quick-clamp mounting adapter (sold separately). They have a smooth probe, and unlike flow switches that measure with a paddle or turbine, these don’t have moving parts for contaminants to get stuck in. Rated IP67 and IP69K, they withstand temporary submersion and high-temperature, high-pressure washdowns. The mounting adapter attaches to a quick-clamp tube tee or outlet (often called tri-clamp fittings) in your large-diameter tubing system using a gasket and clamp (not included), so you don't need to disassemble your line for inline installation. This mounting adapter is also easy to remove and clean.
    They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. They’re accurate in any mounting position.
    Flow Set Point
    13/16"
    Probe Length
    1 13/16"
    Probe Length
    For Tube
    OD
    For Liquids, gpm
    For Gas, scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Food Industry Std.
    Each
    Each
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1 Digital PNP Output Signal
    1 1/2"
    2"
    0.55 to 54.21
    0.97 to 96.37
    4.84 to 72.47
    8.59 to 128.84
    430 psi @ 70° F-10 to 20036250 mA @ 19V DC
    250 mA @ 36V DC
    3 5/16"IP67, IP69K
    C-UL Listed
    UL Listed
    CE Marked
    3-A Certified 74-07, FDA Compliant 21 CFR 177.2415
    4548N1100000004548N120000000
     