High-Temperature Flowmeters with Digital Display
Temp., ° F | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow, gpm | End-to-End Lg. | Overall Ht. | Accuracy | Max. Pressure @ Temp. | Min. | Max. | Seal Material | Mounting Position | Batteries Included | Enclosure Rating | Each | |||
Polypropylene Body with Polypropylene Fittings | ||||||||||||||
3/8 NPT Male | ||||||||||||||
| 0.4 to 4 | 4 3/4" | 5 3/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Yes | IP56 NEMA 4X | 3562K17 | 0000000 | ||
| 0.8 to 8 | 4 3/4" | 5 3/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Yes | IP56 NEMA 4X | 3562K11 | 000000 | ||
1/2 NPT Male | ||||||||||||||
| 2 to 20 | 5 1/8" | 5 3/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Yes | IP56 NEMA 4X | 3562K12 | 000000 | ||
3/4 NPT Male | ||||||||||||||
| 3 to 30 | 5 1/4" | 5 5/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Yes | IP56 NEMA 4X | 3562K13 | 000000 | ||
1 NPT Male | ||||||||||||||
| 5 to 50 | 5 5/8" | 5 5/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Yes | IP56 NEMA 4X | 3562K14 | 000000 | ||
1 1/2 NPT Male | ||||||||||||||
| 6 to 60 | 6 1/2" | 6 1/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Yes | IP56 NEMA 4X | 3562K15 | 000000 | ||
2 NPT Male | ||||||||||||||
| 10 to 100 | 6 3/4" | 6 3/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Yes | IP56 NEMA 4X | 3562K16 | 000000 | ||
| 20 to 200 | 6 3/4" | 6 3/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Yes | IP56 NEMA 4X | 3562K18 | 000000 | ||
High-Temperature Flowmeter/Totalizers
Flowmeter/Totalizers | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Volume Displayed | Temp., ° F | ||||||||||||||
Connections | Flow, gpm | End-to-End Lg. | Accuracy | Total | Batch | Max. Pressure @ Temp. | Mounting Position | Batteries Included | Enclosure Rating | Min. | Max. | Each | |||
Turbine Flow Measurement | |||||||||||||||
Polypropylene Body with Polypropylene Fitting and Fluoroelastomer Seal | |||||||||||||||
| 3/8 NPT Male | 0.8 to 8 | 4 3/4" | ±2% | 99,999.9 Gallons | 999,999 Gallons | 300 psi @ 70° F | Any Angle | Yes | IP56 NEMA 4X | 33 | 200 | 3562K31 | 0000000 | ||
| 1/2 NPT Male | 2 to 20 | 5 1/8" | ±2% | 99,999.9 Gallons | 999,999 Gallons | 300 psi @ 70° F | Any Angle | Yes | IP56 NEMA 4X | 33 | 200 | 3562K32 | 000000 | ||
| 3/4 NPT Male | 3 to 30 | 5 1/4" | ±2% | 99,999.9 Gallons | 999,999 Gallons | 300 psi @ 70° F | Any Angle | Yes | IP56 NEMA 4X | 33 | 200 | 3562K33 | 000000 | ||
| 1 NPT Male | 5 to 50 | 5 5/8" | ±2% | 99,999.9 Gallons | 999,999 Gallons | 300 psi @ 70° F | Any Angle | Yes | IP56 NEMA 4X | 33 | 200 | 3562K34 | 000000 | ||
| 1 1/2 NPT Male | 6 to 60 | 6 1/2" | ±2% | 99,999.9 Gallons | 999,999 Gallons | 300 psi @ 70° F | Any Angle | Yes | IP56 NEMA 4X | 33 | 200 | 3562K35 | 000000 | ||
| 2 NPT Male | 10 to 100 | 6 3/4" | ±2% | 99,999.9 Gallons | 999,999 Gallons | 300 psi @ 70° F | Any Angle | Yes | IP56 NEMA 4X | 33 | 200 | 3562K36 | 000000 | ||
Socket-Connect Flowmeter/Totalizers with Remote Display
Displays
Displays | Brackets | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp., ° F | For Panel Cutout, mm | Mounting Slot | |||||||||||||||||
Maximum Total Volume Displayed | Accuracy | Max. Pressure @ Temp. | Min. | Max. | For DIN Panel Cutout Size | Ht. | Wd. | Dp. | Batteries Included | Enclosure Rating | Each | Lg. | Wd. | No. of | Each | ||||
| 9,999 Gallons 9,999 Liters | ±0.5% | 180 psi @ 70° F | 33 | 149 | 1/4 | 96 | 96 | 41 | Yes | IP65 NEMA 4X | 4114K335 | 0000000 | 3/16" | 3/4" | 4 | 4114K94 | 000000 | ||
Variable-Pressure Flow Switches
Flow Set Point, gpm | Max. Pressure @ Temp. | Temp. Range, ° F | Voltage | Max. Switching Current @ Voltage | Conduit Trade Size | End-to-End Lg. | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|
Bronze Body | ||||||||||
1/4 NPT Female | ||||||||||
| 0.3 to 2 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T211 | 0000000 | ||
| 0.4 to 3 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T212 | 000000 | ||
| 0.5 to 4 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T213 | 000000 | ||
1/2 NPT Female | ||||||||||
| 0.3 to 2 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T221 | 000000 | ||
| 0.4 to 3 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T222 | 000000 | ||
| 0.5 to 4 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T223 | 000000 | ||
| 0.5 to 6 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T224 | 000000 | ||
| 1.5 to 10 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T225 | 000000 | ||
3/4 NPT Female | ||||||||||
| 0.5 to 6 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T231 | 000000 | ||
| 1.5 to 10 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T232 | 000000 | ||
| 2 to 15 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T233 | 000000 | ||
| 3 to 20 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T234 | 000000 | ||
1 NPT Female | ||||||||||
| 2 to 15 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T241 | 000000 | ||
| 3 to 20 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T242 | 000000 | ||
| 4 to 30 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T243 | 000000 | ||
| 5 to 40 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T244 | 000000 | ||
1 1/2 NPT Female | ||||||||||
| 4 to 30 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T251 | 000000 | ||
| 5 to 60 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T253 | 000000 | ||
| 15 to 100 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 1/16" | 2913T254 | 000000 | ||
2 NPT Female | ||||||||||
| 5 to 40 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 3/16" | 2913T261 | 000000 | ||
| 15 to 100 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 3/16" | 2913T263 | 000000 | ||
| 30 to 200 | 400 psi @ 70° F | -30 to 212 | 120V AC/175V DC | 180 mA @ 120V AC 250 mA @ 175V DC | 1/2 | 3 3/16" | 2913T265 | 000000 | ||
High-Temperature Totalizers with Digital Display
Max. Volume Displayed | Temp., ° F | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Connections | Flow, gpm | Total | Batch | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Min. | Max. | Seal Material | Mounting Position | Display Type | Batteries Included | Enclosure Rating | Each | |||
Polypropylene Body with Polypropylene Fittings | |||||||||||||||||
| 3/8 NPT Male | 0.8 to 8 | 99,999.9 Gallons | 999,999 Gallons | 4 3/4" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Digital | Yes | IP56 NEMA 4X | 3562K21 | 0000000 | ||
| 1/2 NPT Male | 2 to 20 | 99,999.9 Gallons | 999,999 Gallons | 5 1/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Digital | Yes | IP56 NEMA 4X | 3562K22 | 000000 | ||
| 3/4 NPT Male | 3 to 30 | 99,999.9 Gallons | 999,999 Gallons | 5 1/4" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Digital | Yes | IP56 NEMA 4X | 3562K23 | 000000 | ||
| 1 NPT Male | 5 to 50 | 99,999.9 Gallons | 999,999 Gallons | 5 5/8" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Digital | Yes | IP56 NEMA 4X | 3562K24 | 000000 | ||
| 1 1/2 NPT Male | 6 to 60 | 99,999.9 Gallons | 999,999 Gallons | 6 1/2" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Digital | Yes | IP56 NEMA 4X | 3562K25 | 000000 | ||
| 2 NPT Male | 10 to 100 | 99,999.9 Gallons | 999,999 Gallons | 6 3/4" | ±2% | 300 psi @ 70° F | 33 | 200 | Fluoroelastomer | Any Angle | Digital | Yes | IP56 NEMA 4X | 3562K26 | 000000 | ||
Insertion-Mount Flow Switches
For Pipe Size | Flow Set Point Range, gpm | Max. Flow Rate, gpm | Paddle Material | Max. Pressure @ Temp. | Temp. Range, ° F | Max. Switching Current @ Voltage | Body Ht. | Enclosure Rating | Certification | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Brass Body with 1 NPT Male Threaded Brass Fittings | |||||||||||||
Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles | |||||||||||||
| 1 2 4 6 | 4.9 to 17.6 13.7 to 56.4 35.3 to 118 60.3 to 245 | 27, 105, 397, 900 | 304 Stainless Steel | 160 psi @ 70° F | 33 to 225 | 3.7 amp @ 240V AC 7.4 amp @ 120V AC | 5" | NEMA 4X | C-UL Listed UL Recognized Component | 4971K5 | 0000000 | ||