    Determine the flow rate and total volume of liquid flowing through your system with the same meter. To measure flow, these flowmeter/totalizers count how many times their turbine turns as liquid passes through. Use them only with clean, low-viscosity liquids to avoid clogging the turbine and other damage to these flowmeter/totalizers. You can reset the batch total, but you can’t reset the cumulative total. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    These flowmeter/totalizers are either calibrated with water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Choose a fitting material that is compatible with the liquid you're running through your line. IP rated, all seal out dust and can be lightly rinsed.
    PVC Body with PVC Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVC Body.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, PVC Body.

    Shown with 90°

    Display Adapter Kit

    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers
    1/2 NPT Female1 to 1080
    6"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T3110000000Digital4352K5130000000———0
    3/4 NPT Female2 to 2080
    6 1/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T321000000Digital4352K523000000———0
    1 NPT Female5 to 5080
    6 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T331000000Digital4352K533000000———0
    1 1/2 NPT Female10 to 10080
    7 5/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T341000000Digital4352K543000000———0
    2 NPT Female20 to 20080
    7 7/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T351000000Digital4352K553000000———0
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T42100000000Digital4352K1090000004352K1120000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1 to 1080
    6"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T431000000Digital4352K513000000———0
    3/4 NPT Female2 to 2080
    6 1/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T441000000Digital4352K523000000———0
    1 NPT Female5 to 5080
    6 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T451000000Digital4352K533000000———0
    1 1/2 NPT Female10 to 10080
    7 5/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T461000000Digital4352K543000000———0
    2 NPT Female20 to 20080
    7 7/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T471000000Digital4352K553000000———0
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T49100000000Digital4352K1090000004352K112000000
     
    Accessories for Flowmeters
    Nylon Body with Nylon Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.

    Shown with 90°

    Display Adapter Kit

    Nylon fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Flowmeter/Totalizers
    1 NPT Female0.3 to 380
    4"±1.5%999,999 Gallons999,999 Gallons150 psi @ 70° F14140YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx Ia IIC T4
    FM Approved
    4352K6320000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1 NPT Female0.3 to 380
    4"±1.5%999,999 Gallons999,999 Gallons150 psi @ 70° F14140YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx Ia IIC T4
    FM Approved
    4352K232000000
     
    Accessories for Flowmeters
    PVDF Body with PVDF Fittings and Fluoroelastomer Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVDF Body.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVDF fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers
    1/2 NPT Female1.2 to 1280
    7 5/16"±2%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K102000000000Digital4352K51300000004352K1040000000
    1 NPT Female5 to 5080
    8 1/16"±1.5%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K10500000000Digital4352K5330000004352K107000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1.2 to 1280
    7 5/16"±2%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K10300000000Digital4352K5130000004352K104000000
     
    Accessories for Flowmeters

    High-Temperature Flowmeters with Digital Display

    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeters with Digital Display.
    Check the flow rate of liquids up to 200° F from an easy-to-read digital display instead of a scale or dial. These flowmeters measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these flowmeters, use them only with clean, low-viscosity liquids. Mount them inline with your pipe system. Their fittings are polypropylene, which works with a wide range of chemicals. NEMA and IP rated, these flowmeters stand up to dust, weather, corrosion, and water from washdowns.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow,
    gpm
    End-to-End
    Lg.
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Each
    Polypropylene Body with Polypropylene Fittings
     
    3/8 NPT Male
    0.4 to 44 3/4"5 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K170000000
    0.8 to 84 3/4"5 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K11000000
     
    1/2 NPT Male
    2 to 205 1/8"5 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K12000000
     
    3/4 NPT Male
    3 to 305 1/4"5 5/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K13000000
     
    1 NPT Male
    5 to 505 5/8"5 5/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K14000000
     
    1 1/2 NPT Male
    6 to 606 1/2"6 1/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K15000000
     
    2 NPT Male
    10 to 1006 3/4"6 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K16000000
    20 to 2006 3/4"6 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K18000000
     
    Replacements for Flowmeters

    Flowmeter/Totalizers for Oil and Fuel

    Image of ProductInUse. Shown with 90° Display
Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers for Oil and Fuel.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers for Oil and Fuel.
    Image of Product. Front orientation. Flowmeter Displays. Flowmeter/Totalizers for Oil and Fuel, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers for Oil and Fuel.

    Replacement Flowmeter

    Rotors

    Use these flowmeter/totalizers to measure both the flow rate and total flow volume of oil, gasoline, diesel fuel, and kerosene. They count how many times their turbine turns as liquid passes through them to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation. Rated NEMA 4 and IP65, they seal out dust and protect against washdowns.
    These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Flowmeter/Totalizers
    Flowmeter/Totalizers with Calibration
    Certificate Traceable to NIST
    Max. Volume
    Displayed
    Temp., ° F
    Temp., ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Min.
    Max.
    Each
    Min.
    Max.
    Each
    Display
    Type
    Each
    Each
    Turbine Flow Measurement
     
    Aluminum Body with Aluminum Fitting and 316 Stainless Steel Seal
    1/2 NPT Female1 to 104 3/16"±2%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K201000000001254352K202000000000Digital4352K51300000004352K6650000000
    3/4 NPT Female2 to 204 5/16"±1.5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K20300000001254352K20400000000Digital4352K5230000004352K666000000
    1 NPT Female0.3 to 34"±5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141404352K672000000141404352K912000000———0———0
    1 NPT Female3 to 504"±1.5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141404352K682000000141404352K922000000———0———0
    1 1/2 NPT Female10 to 1005 5/16"±1%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K2050000000001254352K20600000000Digital4352K5430000004352K668000000
    2 NPT Female20 to 2006"±0.75%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    -402504352K4100000000141404352K4200000000Digital4352K4000000———0
     
    Accessories for Flowmeters

    Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings

    Image of Product. Shown with 90° Display
Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings.
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeter Displays. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    Easy to remove for cleaning and maintenance, these flowmeter/totalizers connect to sanitary quick-clamp fittings (often called tri-clamp fittings) and measure the flow rate and volume of liquid passing through your system. You'll need a gasket and clamp to connect these to your line. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation.
    For use in hazardous locations, these flowmeter/totalizers are FM-approved. They’re also rated NEMA 4 to protect against weather and washdowns.
    These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    Flowmeter/Totalizers
    Replacement Displays
    Max. Volume
    Displayed
    Temp.,
    ° F
    Flowmeter/Totalizers
    Flowmeter/Totalizers with Calibration
    Certificate Traceable to NIST
    For Tube
    OD
    Connections
    Flow,
    gpm
    Flange
    OD
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Each
    Each
    Display
    Type
    Each
    Turbine Flow Measurement
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    3/4"Female1 to 100.984"5"±1.5%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N110000000009011N21000000000Digital9011N4110000000
    1"Female2 to 201.984"5"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N12000000009011N2200000000Digital9011N412000000
    1 1/2"Female5 to 501.984"5 1/2"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N13000000009011N2300000000Digital9011N413000000
    2"Female10 to 1002.515"6 1/2"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N14000000009011N2400000000Digital9011N414000000
    2 1/2"Female20 to 2003.047"7"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N15000000009011N2500000000Digital9011N415000000
     
    Accessories for Flowmeters

    High-Temperature Flowmeter/Totalizers

    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeter/Totalizers.
    With one meter, these flowmeter/totalizers measure the flow rate and total flow volume of high-temperature liquid up to 200° F. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. The batch total can be reset after each metering application. They come set for batch totalization, but you can disable the reset function to operate as a cumulative totalizer. They measure flow correctly no matter the mounting orientation.
    These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Min.
    Max.
    Each
    Turbine Flow Measurement
     
    Polypropylene Body with Polypropylene Fitting and Fluoroelastomer Seal
    3/8 NPT Male0.8 to 84 3/4"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K310000000
    1/2 NPT Male2 to 205 1/8"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K32000000
    3/4 NPT Male3 to 305 1/4"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K33000000
    1 NPT Male5 to 505 5/8"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K34000000
    1 1/2 NPT Male6 to 606 1/2"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K35000000
    2 NPT Male10 to 1006 3/4"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K36000000
     
    Replacements for Flowmeters

    Socket-Connect Flowmeter/Totalizers with Remote Display

    Often used in hard-to-access areas, these flowmeter/totalizers have a display that can be placed up to 25 feet from the sensor. Use them to measure the rate and volume of liquid flowing through your system. They measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Batch totals are resettable but can be protected with a security code to prevent tampering. The reset function can also be disabled so that they operate as a cumulative totalizer. Cumulative totals cannot be reset. No matter the mounting orientation, they’ll measure flow correctly.
    These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    For a complete unit, you’ll need a display, a sensor, and a tee fitting.
    Displays
    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers with Remote Display, Displays.
    Displays are rated NEMA 4X and IP65 for protection against dust, weather, washdowns, and corrosion.
    Displays
    Brackets
    Temp.,
    ° F
    For Panel
    Cutout, mm
    Mounting Slot
    Maximum Total
    Volume Displayed
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    For DIN Panel
    Cutout Size
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Lg.
    Wd.
    No.
    of
    Each
    9,999 Gallons
    9,999 Liters
    ±0.5%180 psi @ 70° F331491/4969641YesIP65
    NEMA 4X
    4114K33500000003/16"3/4"44114K94000000
     

    Variable-Pressure Flow Switches

    Image of Product. Front orientation. Flow Switches. Variable-Pressure Flow Switches.
    Accurate even in applications where pressure fluctuates regularly, these flow switches split flow into two paths and measure their difference in pressure drop to calculate the flow rate of liquid. They activate or deactivate equipment when the flow rate reaches your set point. Tighten or loosen the adjustment screw to choose your set point anywhere within the range. They measure accurately no matter their mounting position. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). Rated NEMA 4X and IP66, they seal out dust and protect against washdowns and corrosion.
    These switches are calibrated with water. They can also be used with other liquids but may not measure accurately if their viscosity is significantly different.
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage
    Max. Switching Current @ Voltage
    Conduit
    Trade Size
    End-to-End
    Lg.
    Each
    Bronze Body
     
    1/4 NPT Female
    0.3 to 2400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T2110000000
    0.4 to 3400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T212000000
    0.5 to 4400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T213000000
     
    1/2 NPT Female
    0.3 to 2400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T221000000
    0.4 to 3400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T222000000
    0.5 to 4400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T223000000
    0.5 to 6400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T224000000
    1.5 to 10400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T225000000
     
    3/4 NPT Female
    0.5 to 6400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T231000000
    1.5 to 10400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T232000000
    2 to 15400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T233000000
    3 to 20400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T234000000
     
    1 NPT Female
    2 to 15400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T241000000
    3 to 20400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T242000000
    4 to 30400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T243000000
    5 to 40400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T244000000
     
    1 1/2 NPT Female
    4 to 30400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T251000000
    5 to 60400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T253000000
    15 to 100400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 1/16"2913T254000000
     
    2 NPT Female
    5 to 40400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 3/16"2913T261000000
    15 to 100400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 3/16"2913T263000000
    30 to 200400 psi @ 70° F-30 to 212120V AC/175V DC180 mA @ 120V AC
    250 mA @ 175V DC
    1/2
    3 3/16"2913T265000000
     

    High-Temperature Totalizers with Digital Display

    Image of Product. Front orientation. Flowmeters. High-Temperature Totalizers with Digital Display.
    The digital display on these totalizers makes it easy to check the total amount of high-temperature liquid—up to 200° F—passing through your system. They measure flow volume by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. The batch total can be reset after each metering application. They come set for batch totalization, but you can disable the reset function to operate as a cumulative totalizer. They measure flow accurately no matter the mounting orientation. Rated NEMA 4X and IP65, they seal out dust and protect against washdowns and corrosion.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Total
    Batch
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Display
    Type
    Batteries
    Included
    Enclosure
    Rating
    Each
    Polypropylene Body with Polypropylene Fittings
    3/8 NPT Male0.8 to 899,999.9 Gallons999,999 Gallons4 3/4"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K210000000
    1/2 NPT Male2 to 2099,999.9 Gallons999,999 Gallons5 1/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K22000000
    3/4 NPT Male3 to 3099,999.9 Gallons999,999 Gallons5 1/4"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K23000000
    1 NPT Male5 to 5099,999.9 Gallons999,999 Gallons5 5/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K24000000
    1 1/2 NPT Male6 to 6099,999.9 Gallons999,999 Gallons6 1/2"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K25000000
    2 NPT Male10 to 10099,999.9 Gallons999,999 Gallons6 3/4"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K26000000
     
    Replacements for Flowmeters

    Airflow-Actuated HVAC Switches

    Image of Product. Front orientation. HVAC Switches. Airflow-Actuated HVAC Switches.
    Use this switch to sense changes in airflow velocity in duct. The paddle extends into the duct and actuates the switch when airflow reaches the setpoint. Switch is rated NEMA 3R for protection from dirt, falling liquids, and light splashing.
    Paddle
    Speed Set Point,
    fpm
    Temp. Range,
    ° F
    Current @ Voltage
    Electrical
    Connection
    Switch
    Designation
    For Conduit
    Trade Size
    Knockout
    Dia.
    Material
    Ht.
    Wd.
    For Use
    Outdoors
    Enclosure
    Rating
    Certification
    Each
    Paddle Sensors
    350 to 50032 to 10410 amp @ 240V AC
    16 amp @ 120V AC
    Screw TerminalSPDT
    1/2
    7/8"Stainless Steel
    6 7/8"3 1/8"YesIP43, NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    1783K130000000
     

    Hazardous-Location Insertion-Mount Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. Hazardous-Location Insertion-Mount Flow Switches.
    Safely activate and deactivate equipment in environments with flammable gases and combustible dust when your flow rate reaches a set point. They are UL listed and CSA certified for use in hazardous locations. These switches save you from disassembling your pipeline because you insert them into pipe tees or pipe outlets instead of mounting them inline. They actuate when your system’s liquid pushes the paddle into a set position. To change your set point, the paddle has multiple layers that you can remove. For the lowest set point, use the largest paddle that will fit your pipe. To increase your set point, loosen the locking washers and remove paddles. You can trim the paddles to fine-tune your set point. The smaller the paddle, the higher the setpoint.
    They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    SPDT—SPDT (singe pole, double throw) switches can turn one device from off to on (normally open) or from on to off (normally closed).
    DPDT—DPDT (double pole, double throw) switches can either turn two devices from off to on (normally open) or on to off (normally closed).
    Flow Set Point Range
    Max. Flow Rate
    Conduit
    Pipe
    Size
    Thread
    Type
    Gender
    For Pipe
    Size
    For Water and Oil
    For Air and Inert Gas
    For Water
    and Oil
    For Air and
    Inert Gas
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Body
    Ht.
    Each
    SPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K530000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K5500000000
     
    DPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K54000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K5600000000
     

    Fixed-Set-Point Hazardous-Location Flow Switches

    Image of Product. Front orientation. Flow Switches. Fixed-Set-Point Hazardous-Location Flow Switches.
    Safe to use where flammable gases and combustible dust may be present, these switches activate or deactivate when your flow reaches a factory-set level. All are UL listed for hazardous environments. Because their set point is fixed, they’re ready to go, making them easy to install. They actuate when your flowing liquid or gas pushes their paddle into a set position. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function accurately.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    Set Point
    Conduit
    Pipe
    Connections
    For Liquids,
    gpm
    For Gas,
    scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with Threaded 304 Stainless Steel Fittings
    1/2 NPT Female1.56.52,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 1/4"NEMA 4
    UL Listed
    CE Marked
    47565K610000000
    3/4 NPT Female2102,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 5/8"NEMA 4
    UL Listed
    CE Marked
    47565K62000000
    1 NPT Female3142,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3"NEMA 4
    UL Listed
    CE Marked
    47565K63000000
    2 NPT Female10432,000 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male4 3/4"NEMA 4
    UL Listed
    CE Marked
    47565K6600000000
     
    Brass Body with Threaded Brass Fittings
    1/2 NPT Female1.56.5250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 1/4"NEMA 4
    UL Listed
    CE Marked
    47565K31000000
    3/4 NPT Female210250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 3/8"NEMA 4
    UL Listed
    CE Marked
    47565K32000000
    1 NPT Female314250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 1/2"NEMA 4
    UL Listed
    CE Marked
    47565K33000000
    1 1/4 NPT Female421250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 5/8"NEMA 4
    UL Listed
    CE Marked
    47565K34000000
    1 1/2 NPT Female633250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male2 7/8"NEMA 4
    UL Listed
    CE Marked
    47565K35000000
    2 NPT Female1043250 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3"NEMA 4
    UL Listed
    CE Marked
    47565K36000000
     

    Insertion-Mount Flow Switches

    Image of Product. Threaded Connection with NEMA 4X Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection, NEMA 4X Enclosure Rating.

    Threaded

    Connection with

    NEMA 4X Rating

    Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. They are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They should be mounted vertically into a large-diameter horizontal pipeline, so liquid pushes the paddle.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Brass Body—Switches with a brass or 316 stainless steel body have multiple paddles you can choose between to get you closest to your set point. For a higher set point, loosen the locking washers to remove the largest paddles. You can also trim the paddles to fine-tune your set point. The more you trim, the higher the set point.
    Brass Fitting—Brass and 316 stainless steel fittings resist impact better than Noryl fittings.
    NEMA 4X Enclosure Rating—NEMA 4X rated switches protect against dust, weather, and washdowns.
    For Pipe
    Size
    Flow Set Point Range, gpm
    Max. Flow Rate, gpm
    Paddle Material
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Brass Body with 1 NPT Male Threaded Brass Fittings
     
    Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles
    1
    2
    4
    6
    4.9 to 17.6
    13.7 to 56.4
    35.3 to 118
    60.3 to 245
    27, 105, 397, 900304 Stainless Steel
    160 psi @ 70° F33 to 2253.7 amp @ 240V AC
    7.4 amp @ 120V AC
    5"NEMA 4X
    C-UL Listed
    UL Recognized Component
    4971K50000000
     

    Hazardous-Location Flow Switches

    Image of Product. Front orientation. Flow Switches. Hazardous-Location Flow Switches.
    UL listed for use where flammable gases or combustible dusts may be present, these flow switches activate or deactivate equipment when your flow rate reaches a set point. Use the adjustment screw to select their set point. They actuate when your flowing liquid or gas pushes their paddle into a certain position determined by the set point. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). Mount them horizontally. Rated NEMA 4, they also protect against weather and washdowns.
    These flow switches are calibrated with water and air. You can use them with other liquids and gases, but they may not measure accurately if the viscosity is different from water or air.
    Flow Set Point
    Conduit
    Pipe
    Connections
    For Liquids,
    gpm
    For Gas,
    scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage, V AC
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with Threaded 304 Stainless Steel Fittings
    1/2 NPT Female0.04 to 0.750.18 to 2.71,450 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3 5/8"NEMA 4
    UL Listed
    CE Marked
    91445K240000000
     
    Brass Body with Threaded Brass Fittings
    1/2 NPT Female0.04 to 0.750.18 to 2.71,450 psi @ 70° F-4 to 220120/2405 amp @ 120V AC3/4
    NPT
    Male3 5/8"NEMA 4
    UL Listed
    CE Marked
    91445K23000000
     
    back to top