    Easy Read Flowmeters

    Image of Specification. Style B—Left to Right. Front orientation. Left to Right. Easy Read Flowmeters, Bronze Body, Female, Style B.
    Image of Specification. Style B—Right to Left. Front orientation. Right to Left. Easy Read Flowmeters, Bronze Body, Female, Style B.

    Style B—Left to Right

    Style B—Right to Left

    Image of Specification. Style B—Bottom to Top. Front orientation. Bottom to Top. Easy Read Flowmeters, Bronze Body, Female, Style B.
    Image of Specification. Style B—Top to Bottom. Front orientation. Top to Bottom. Easy Read Flowmeters, Bronze Body, Female, Style B.

    Style B—Bottom to Top

    Style B—Top to

    Bottom

    A large dial instead of a scale makes it easier to read the flow rate from a distance. As liquid flows through these flowmeters, it pushes a needle along the dial, showing you the flow rate. They measure flow correctly no matter the mounting orientation.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a direction of flow that matches your pipe system, so you don't have to tilt your head to read the dial.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Bronze Fitting—Bronze fittings resist impact better than PVC fittings.
    Style B—Style B flowmeters should be installed away from other fittings to get the most accurate reading. To determine how far away from the fittings it should be, take your pipe's diameter and multiply it by 10.
    Temp.,
    ° F
    Style
    Flow,
    gpm
    Dial
    Size
    End-to-End
    Lg.
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Choose a Direction of Flow
    Each
    Bronze Body with Bronze Fittings
     
    3 NPT Female
    B40 to 3003 1/2"9 13/16"9 13/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K57000000000
     

    Easy-Read Flowmeters for Gases

    Instead of a scale, these flowmeters have a large dial that makes it easy to read the flow rate of your gas from a distance. As gas flows through, it pushes a needle along the dial, showing you the flow rate.
    These flowmeters are calibrated with air but can be used with other gases. If you’re using these with a gas other than air, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your gas.
    Bronze Body with Bronze Fittings
    Image of Specification. Front orientation. Left to Right. Easy-Read Flowmeters for Gases, Bronze Body, Female.
    Image of Specification. Front orientation. Right to Left. Easy-Read Flowmeters for Gases, Bronze Body, Female.
    Image of Specification. Front orientation. Bottom to Top. Easy-Read Flowmeters for Gases, Bronze Body, Female.
    Image of Specification. Front orientation. Top to Bottom. Easy-Read Flowmeters for Gases, Bronze Body, Female.

    Female

    Left to Right

    Female

    Right to Left

    Female

    Bottom to Top

    Female

    Top to Bottom

    Flowmeters with a bronze body should be installed away from other fittings to get the most accurate reading. To determine how far away from the fittings it should be, take your pipe's diameter and multiply it by 10. Choose a direction of flow that matches your pipe system, so you don't have to tilt your head to read the dial.
    Temp.,
    ° F
    3 1/2" Dial Size
    Flow, scfm
    End-to-End
    Lg.
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Choose a Direction of Flow
    Each
    3 NPT Female
    300 to 2,0004 9/16"9 13/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom42005K37000000000
     

    Build-Your-Own Flanged Pipe Flow Transmitters

    Image of System. Components Sold Separately (Pipe Flanges Not Included). Front orientation. Contains Annotated. Flow Transmitters. Build-Your-Own Flanged Pipe Flow Transmitters.

    Components Sold Separately (Pipe Flanges

    Not Included)

    Install these transmitters between two flanges in a flanged pipe system to measure flow rate and send the data to a remote display or programmable logic controller (PLC). For easy cleaning and maintenance, you can slide the transmitter out from between the flanges. A complete transmitter consists of a flow transmitter, display, and mounting hardware kit (all components sold separately). Flowing liquid turns the turbine in the transmitter, while the easy-to-read display counts the number of turns to measure and transmit the flow. The display also shows total and batch flow volumes. Use these transmitters with clean, low-viscosity liquids to avoid clogging or other damage to the internal parts. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    Also known as transducers, these transmitters help you monitor status or control equipment by converting measurements to a digital pulse that can be interpreted by receiving devices. Each pulse is a spike of voltage. The higher the flow, the more pulses they send. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the measurement range and output signal of the transmitter. Transmitters will only provide accurate readings within the rated measurement range.
    The transmitters are calibrated with water but can be used with other liquids.
    Flow Transmitters
    Image of Product. Front orientation. Flow Transmitters. Build-Your-Own Flanged Pipe Flow Transmitters, Flow Transmitters.
    Flange
    Flow Measurement
    Type
    Pipe
    Size
    Flow Range,
    gpm
    Bore
    Size
    OD
    Type
    For Flange
    ANSI Class
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Mounting
    Position
    Field
    Recalibratable
    Pulse Frequency per
    Volume, pulse per gal.
    Each
    One Digital Pulse Output—2-Pin BNC Connection Plug
     
    316/316L Stainless Steel Body with 316/316L Stainless Steel Fitting
    Turbine3
    60 to 6003"5"Round150
    4 1/4"±1.0%285 psi @ 70° F-150 to 350Any AngleNo504408N14000000000
     
    Flow Transmitter Repair Kits
    Mounting Hardware Kits
    Image of Product. Front orientation. Flow Transmitters. Build-Your-Own Flanged Pipe Flow Transmitters, Mounting Hardware.
    For Pipe
    Size
    For Flange
    ANSI Class
    Includes
    Each
    3
    150
    4 Studs, 12 Nuts, 2 Gaskets, 2 Centering Rings4408N170000000
     

    Flanged Flowmeter/Totalizers

    Image of Product. Front orientation. Flowmeters. Flanged Flowmeter/Totalizers.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flanged Flowmeter/Totalizers.

    Replacement Displays

    Using the flanged ends, securely install these flowmeter/totalizers in large, high-flow pipelines to measure the flow rate and total volume of liquid flowing through. They use ultrasonic waves to measure flow, so they don’t have any internal moving parts that can break or get stuck. You can reset the batch total, but you can't reset the cumulative total. They measure accurately in any mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Flange
    OD
    For Flange
    ANSI Class
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    3 Pipe Size
    2.06 to 3097 1/2"150
    13 1/4"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K61000000000Digital3777K6150000000
     

    Flanged Totalizers for Drinking Water

    Image of Product. Front orientation. Flowmeters. Flanged Totalizers for Drinking Water, Bronze Body, Round Flange.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. Flanged Totalizers for Drinking Water, Bronze Body.

    Bronze Body

    Round Flange

    Bronze Body

    Analog Display

    Flanged ends let you securely integrate these totalizers into large drinking water pipelines to measure the cumulative amount of water flowing through them. They meet NSF/ANSI 61, so they're safe to use with drinking water. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Their total cannot be reset.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Flange
    Temp.,
    ° F
    Bolt
    Connections
    OD
    Type
    Flow,
    gpm
    Maximum Total Volume
    Displayed
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Hole
    Dia.
    Circle
    Dia.
    No. of
    Holes
    Each
    Bronze Body with Brass Fittings
    3 Pipe Size
    7 1/2"Round5 to 53099,999,000 Gallons12"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog3/4"6"44189K32000000000
     

    Insertion Flowmeters

    Image of ProductInUse. Front orientation. Flowmeters. Insertion Flowmeters.
    No need to disassemble your PVC pipeline—insert these flowmeters into a drilled hole and secure them using the included clamps. As liquid flows through the meter, it pushes an indicator up the scale, showing you the flow rate. They have a clear body, so you can check the color and clarity of flowing liquid to identify and diagnose problems. Mount these flowmeters vertically.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Flow for Pipe
    Schedule, gpm
    Temp.,
    ° F
    Pipe
    Size
    Schedule
    40
    Schedule
    80
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Acrylic Plastic Body with 316 Stainless Steel Fittings
    3
    45 to 24040 to 2156"±10%75 psi @ 70° F33190Neoprene
    Vertical4349K610000000
     

    Any-Orientation Flowmeters

    Image of Product. Front orientation. Flowmeters. Any-Orientation Flowmeters, Female.

    Female

    A spring piston instead of a float allows these flowmeters to measure flow rate in any mounting orientation. As liquid passes through, it pushes an indicator up the scale, showing you the flow rate. They have union fittings on both ends, making it easy to position the scale so it’s visible.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    Brass Fitting—Brass fittings resist impact better than polysulfone fittings.
    Temp.,
    ° F
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Polysulfone Body with Brass Fittings
     
    3 NPTF Female
    25 to 27510 3/4"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K651000000000
     

    Socket-Connect Flowmeter/Totalizers

    Image of ProductInUse. Shown with 90° Display
Adapter Kit. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.
    Image of Product. Front orientation. Flowmeter Displays. Socket-Connect Flowmeter/Totalizers, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    The unthreaded ends of these flowmeter/totalizers install into a PVC piping system, so you can measure the flow rate and volume of liquid passing through your system. Bond the joint together with PVC cement and primer. You can reset the batch total, but you can't reset the cumulative total. They measure flow correctly no matter the mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Ultrasonic Flow Measurement—Ultrasonic flowmeter/totalizers measure flow with ultrasonic waves, so they don’t have internal moving parts that can break or get stuck.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    3 Male2.06 to 30980
    6 5/8"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K51000000000Digital3777K6150000000
     

    Insertion-Mount Flow Switches

    Image of Product. Socket Connection with IP65 Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Socket-Connect Fitting Connection, IP65 Enclosure Rating.
    Image of Product. Threaded Connection with IP65 Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection, IP65 Enclosure Rating.

    Socket

    Connection

    with IP65

    Rating

    Threaded

    Connection

    with IP65

    Rating

    Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. They are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They should be mounted vertically into a large-diameter horizontal pipeline, so liquid pushes the paddle.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Noryl Body—Switches with a Noryl body have a paddle that you trim to adjust the set point. The more you trim, the higher the set point.
    Socket-Connect Fitting Connection—Socket-connect flow switches bond to an unthreaded PVC pipe tee or pipe outlet with PVC cement and primer (not included).
    Brass Fitting—Brass and 316 stainless steel fittings resist impact better than Noryl fittings.
    Noryl Fitting—Noryl fittings work with a wide range of chemicals.
    IP65 Enclosure Rating—IP65 rated switches seal out dust and can be lightly rinsed.
    For Pipe Size
    Flow Set Point Range, gpm
    Max. Flow Rate, gpm
    Paddle Material
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Specs.
    Met
    Each
    Noryl Body with 3/4 Socket-Connect Noryl Fittings
     
    Set-Point-Adjustment Trimmable Paddles
    1 1/2
    2
    3
    7.7 to 19.3
    10.3 to 21
    16.5 to 52
    110; 150; 390Noryl160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K410000000
    1 1/2
    2
    3
    7.9 to 15
    10 to 22
    18 to 50
    144; 240; 650301 Stainless Steel
    160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K111000000
     
    Noryl Body with 1/2 NPT Male Threaded Brass Fittings
     
    Set-Point-Adjustment Trimmable Paddles
    1 1/2
    2
    3
    4
    8
    7.7 to 19.3
    10.3 to 21
    16.5 to 52
    25.5 to 68
    126 to 240
    110; 150; 390; 420; 1,100Noryl160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K43000000
    1 1/2
    2
    3
    4
    8
    7.9 to 15
    10 to 22
    18 to 50
    25 to 66
    114 to 176
    144; 240; 650; 800; 1,900301 Stainless Steel
    160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K112000000
     

    Socket-Connect Flowmeter/Totalizers with Remote Display

    Often used in hard-to-access areas, these flowmeter/totalizers have a display that can be placed up to 25 feet from the sensor. Use them to measure the rate and volume of liquid flowing through your system. They measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Batch totals are resettable but can be protected with a security code to prevent tampering. The reset function can also be disabled so that they operate as a cumulative totalizer. Cumulative totals cannot be reset. No matter the mounting orientation, they’ll measure flow correctly.
    These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    For a complete unit, you’ll need a display, a sensor, and a tee fitting.
    Tee Fittings
    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers with Remote Display, Tee Fittings.
    Tee fittings mount inline with your pipe. They have two unthreaded socket ends that bond to unthreaded PVC pipe with PVC cement and primer.
    Temp.,
    ° F
    Inlet/Outlet Connection
    Sensor Connection
    Pipe
    Schedule
    Flow, gpm
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Mounting
    Position
    Each
    PVC Body
    3 Socket Connect Female Inlet Pipe × 3 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    23 to 460.8180 psi @ 70° F33149Any Angle4114K2380000000
     