    Contactless Flow Transmitters

    Image of ProductInUse. Front orientation. Flow Transmitters. Contactless Flow Transmitters.
    Using ultrasonic waves, these transmitters measure the flow rate of your liquid from outside your pipe. They're a good choice for applications where you need to retrofit your system or avoid liquid coming into contact with the transmitter. Also known as transducers, these transmitters convert measurements to an electrical pulse that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). The pulse outputs match the input voltage of the transmitter. The higher the flow, the more pulses they send. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Configure them for either a 4-20mA or digital pulse output when installing.
    A digital display makes it easy to check flow rate and configure settings. Clamp these transmitters onto your pipe with the included mounting hardware and gel pads. They measure flow no matter the mounting orientation.
    These transmitters are calibrated with water but can be used with other liquids and will generally measure accurately, even if they differ in viscosity and density. You can recalibrate them in the field for accurate readings on pipe and operating conditions.
    Flow Range for
    Pipe Size, gpm
    Input
    Voltage
    Flow Measurement
    Type
    For Pipe
    Size
    3/4
    2
    4
    End-to-End
    Lg.
    Accuracy
    Temp. Range,
    ° F
    Min.,
    V DC
    Max.
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Pulse Output and One 4-20 mA Analog Transmitter Output—Wire Lead Connection
     
    Polycarbonate Body
    Ultrasonic3/4 to 40 to 450 to 3200 to 1,2859 3/4"±3%32 to 1851224V AC/24V DCAny AngleYesIP54
    4399N11000000000
     

    Portable Noncontact Flowmeters

    Image of ProductInUse. Front orientation. Contains MultipleImages. Flowmeters. Portable Noncontact Flowmeters.
    Image of Product. Front orientation. Contains MultipleImages. Flowmeters. Portable Noncontact Flowmeters.
    Often used to pinpoint flow issues, these flowmeters clamp onto pipe, so you can spot-check the flow rate at different points without disassembling your system. They measure by tracking the time it takes for ultrasonic waves to pass through your liquid, so they don’t need to come into contact with your liquid. As a result, they can be used with a wider range of liquids than other flowmeters.
    Flow for Pipe
    Size, gpm
    Temp.,
    ° F
    For Pipe
    Size
    1/2
    2
    4
    Speed,
    ft/sec
    Overall
    Ht.
    Accuracy
    Min.
    Max.
    Batteries
    Included
    Display
    Type
    Includes
    Each
    Polycarbonate Body
    1/2 to 40.2 to 304 to 55015 to 2,0000.03 to 1003 15/16"±1.0%-20320YesDigitalCarrying Case, Mounting Hardware, Optional Power Source and Cable, Ultrasonic Gel4416N11000000000
     
    Replacement Ultrasonic Gel

    Insertion Flowmeters

    Image of ProductInUse. Front orientation. Flowmeters. Insertion Flowmeters.
    No need to disassemble your PVC pipeline—insert these flowmeters into a drilled hole and secure them using the included clamps. As liquid flows through the meter, it pushes an indicator up the scale, showing you the flow rate. They have a clear body, so you can check the color and clarity of flowing liquid to identify and diagnose problems. Mount these flowmeters vertically.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Flow for Pipe
    Schedule, gpm
    Temp.,
    ° F
    Pipe
    Size
    Schedule
    40
    Schedule
    80
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Acrylic Plastic Body with 316 Stainless Steel Fittings
    4
    75 to 42070 to 3756"±10%75 psi @ 70° F33190Neoprene
    Vertical4349K70000000
     

    Flanged Totalizers for Drinking Water

    Image of Product. Front orientation. Flowmeters. Flanged Totalizers for Drinking Water, Bronze Body, Round Flange.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. Flanged Totalizers for Drinking Water, Bronze Body.

    Bronze Body

    Round Flange

    Bronze Body

    Analog Display

    Flanged ends let you securely integrate these totalizers into large drinking water pipelines to measure the cumulative amount of water flowing through them. They meet NSF/ANSI 61, so they're safe to use with drinking water. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Their total cannot be reset.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Flange
    Temp.,
    ° F
    Bolt
    Connections
    OD
    Type
    Flow, gpm
    Maximum Total Volume
    Displayed
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Hole
    Dia.
    Circle
    Dia.
    No. of
    Holes
    Each
    Bronze Body with Brass Fittings
    4 Pipe Size
    8 7/8"Round9 to 1,35099,999,000 Gallons14"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog3/4"7 1/2"84189K33000000000
     

    Flanged Flowmeter/Totalizers

    Image of Product. Front orientation. Flowmeters. Flanged Flowmeter/Totalizers.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flanged Flowmeter/Totalizers.

    Replacement Displays

    Using the flanged ends, securely install these flowmeter/totalizers in large, high-flow pipelines to measure the flow rate and total volume of liquid flowing through. They use ultrasonic waves to measure flow, so they don’t have any internal moving parts that can break or get stuck. You can reset the batch total, but you can't reset the cumulative total. They measure accurately in any mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Flange
    OD
    For Flange
    ANSI Class
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    4 Pipe Size
    3.58 to 5379"150
    13 3/16"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K62000000000Digital3777K6250000000
     

    Flowmeter/Totalizers

    Determine the flow rate and total volume of liquid flowing through your system with the same meter. To measure flow, these flowmeter/totalizers count how many times their turbine turns as liquid passes through. Use them only with clean, low-viscosity liquids to avoid clogging the turbine and other damage to these flowmeter/totalizers. You can reset the batch total, but you can’t reset the cumulative total. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    These flowmeter/totalizers are either calibrated with water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Choose a fitting material that is compatible with the liquid you're running through your line. IP rated, all seal out dust and can be lightly rinsed.
    PVC Body with PVC Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVC Body.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, PVC Body.

    Shown with 90°

    Display Adapter Kit

    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T421000000000Digital4352K10900000004352K1120000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T49100000000Digital4352K1090000004352K112000000
     
    Accessories for Flowmeters

    Insertion-Mount Flow Switches

    Image of Product. Threaded Connection with IP65 Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection, IP65 Enclosure Rating.
    Image of Product. Threaded Connection with NEMA 4X Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection, NEMA 4X Enclosure Rating.
    Image of Product. Threaded Connection. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection.

    Threaded

    Connection

    with IP65

    Rating

    Threaded

    Connection with

    NEMA 4X Rating

    Threaded Connection

    Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. They are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They should be mounted vertically into a large-diameter horizontal pipeline, so liquid pushes the paddle.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    316 Stainless Steel Body and Brass Body—Switches with a brass or 316 stainless steel body have multiple paddles you can choose between to get you closest to your set point. For a higher set point, loosen the locking washers to remove the largest paddles. You can also trim the paddles to fine-tune your set point. The more you trim, the higher the set point.
    Noryl Body—Switches with a Noryl body have a paddle that you trim to adjust the set point. The more you trim, the higher the set point.
    316 Stainless Steel Fitting and Brass Fitting—Brass and 316 stainless steel fittings resist impact better than Noryl fittings.
    IP65 Enclosure Rating—IP65 rated switches seal out dust and can be lightly rinsed.
    NEMA 4X Enclosure Rating—NEMA 4X rated switches protect against dust, weather, and washdowns.
    For Pipe Size
    Flow Set Point Range, gpm
    Max. Flow Rate, gpm
    Paddle Material
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Specs.
    Met
    Certification
    Each
    Noryl Body with 1/2 NPT Male Threaded Brass Fittings
     
    Set-Point-Adjustment Trimmable Paddles
    1 1/2
    2
    3
    4
    8
    7.7 to 19.3
    10.3 to 21
    16.5 to 52
    25.5 to 68
    126 to 240
    110; 150; 390; 420; 1,100Noryl160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K430000000
    1 1/2
    2
    3
    4
    8
    7.9 to 15
    10 to 22
    18 to 50
    25 to 66
    114 to 176
    144; 240; 650; 800; 1,900301 Stainless Steel
    160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K112000000
     
    Brass Body with 1 NPT Male Threaded Brass Fittings
     
    Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles
    1
    2
    4
    6
    4.9 to 17.6
    13.7 to 56.4
    35.3 to 118
    60.3 to 245
    27; 105; 397; 900304 Stainless Steel
    160 psi @ 70° F33 to 2253.7 amp @ 240V AC
    7.4 amp @ 120V AC
    5"NEMA 4X
    C-UL Listed
    UL Recognized Component
    4971K5000000
    1
    2
    4
    6
    6 to 10.2
    18.8 to 32.8
    39.7 to 73.5
    79.2 to 166
    27; 105; 397; 900304 Stainless Steel
    160 psi @ 70° F33 to 3003.7 amp @ 240V AC
    7.4 amp @ 120V AC
    5"C-UL Listed
    UL Listed
    4971K3000000
     
    316 Stainless Steel Body with 1 NPT Male Threaded 316 Stainless Steel Fittings
     
    Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles
    1
    2
    4
    6
    6 to 10.2
    18.8 to 32.8
    39.7 to 73.5
    79.2 to 166
    27; 105; 397; 900304 Stainless Steel
    160 psi @ 70° F33 to 3003.7 amp @ 240V AC
    7.4 amp @ 120V AC
    5"C-UL Listed
    UL Listed
    4971K4000000
     

    Hazardous-Location Insertion-Mount Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. Hazardous-Location Insertion-Mount Flow Switches.
    Safely activate and deactivate equipment in environments with flammable gases and combustible dust when your flow rate reaches a set point. They are UL listed and CSA certified for use in hazardous locations. These switches save you from disassembling your pipeline because you insert them into pipe tees or pipe outlets instead of mounting them inline. They actuate when your system’s liquid pushes the paddle into a set position. To change your set point, the paddle has multiple layers that you can remove. For the lowest set point, use the largest paddle that will fit your pipe. To increase your set point, loosen the locking washers and remove paddles. You can trim the paddles to fine-tune your set point. The smaller the paddle, the higher the setpoint.
    They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    SPDT—SPDT (singe pole, double throw) switches can turn one device from off to on (normally open) or from on to off (normally closed).
    DPDT—DPDT (double pole, double throw) switches can either turn two devices from off to on (normally open) or on to off (normally closed).
    Flow Set Point Range
    Max. Flow Rate
    Conduit
    Pipe
    Size
    Thread
    Type
    Gender
    For Pipe
    Size
    For Water and Oil
    For Air and Inert Gas
    For Water
    and Oil
    For Air and
    Inert Gas
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Body
    Ht.
    Each
    SPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K530000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K5500000000
     
    DPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K54000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K5600000000
     

    Socket-Connect Flowmeter/Totalizers

    Image of ProductInUse. Shown with 90° Display
Adapter Kit. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.
    Image of Product. Front orientation. Flowmeter Displays. Socket-Connect Flowmeter/Totalizers, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    The unthreaded ends of these flowmeter/totalizers install into a PVC piping system, so you can measure the flow rate and volume of liquid passing through your system. Bond the joint together with PVC cement and primer. You can reset the batch total, but you can't reset the cumulative total. They measure flow correctly no matter the mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Ultrasonic Flow Measurement—Ultrasonic flowmeter/totalizers measure flow with ultrasonic waves, so they don’t have internal moving parts that can break or get stuck.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    4 Male3.58 to 53780
    7 3/8"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K52000000000Digital3777K6250000000
     
    back to top