McMaster-Carr logo
    Filter by
    Fitting Connection
    Industrial Info Compare
    For Use With
    Maximum Flow
    Connects To
    Calibrated With
    Flow Measurement Type
    Display Type
    Mounting Location
    Fitting Material
    Maximum Pressure @ Temperature
    Calibration Media Specific Gravity
    Minimum Temperature
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Mounting Position
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    4 Products

    Flanged Totalizers for Drinking Water

    Image of Product. Front orientation. Flowmeters. Flanged Totalizers for Drinking Water, Bronze Body, Round Flange.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. Flanged Totalizers for Drinking Water, Bronze Body.

    Bronze Body

    Round Flange

    Bronze Body

    Analog Display

    Flanged ends let you securely integrate these totalizers into large drinking water pipelines to measure the cumulative amount of water flowing through them. They meet NSF/ANSI 61, so they're safe to use with drinking water. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Their total cannot be reset.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Flange
    Temp.,
    ° F
    Bolt
    Connections
    OD
    Type
    Flow, gpm
    Maximum Total Volume
    Displayed
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Hole
    Dia.
    Circle
    Dia.
    No. of
    Holes
    Each
    Bronze Body with Brass Fittings
    6 Pipe Size
    11 1/8"Round25 to 2,70099,999,000 Gallons18"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog7/8"9 1/2"84189K34000000000
     

    Insertion-Mount Flow Switches

    Image of Product. Threaded Connection with NEMA 4X Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection, NEMA 4X Enclosure Rating.
    Image of Product. Threaded Connection. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection.

    Threaded

    Connection with

    NEMA 4X Rating

    Threaded Connection

    Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. They are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They should be mounted vertically into a large-diameter horizontal pipeline, so liquid pushes the paddle.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    316 Stainless Steel Body and Brass Body—Switches with a brass or 316 stainless steel body have multiple paddles you can choose between to get you closest to your set point. For a higher set point, loosen the locking washers to remove the largest paddles. You can also trim the paddles to fine-tune your set point. The more you trim, the higher the set point.
    316 Stainless Steel Fitting and Brass Fitting—Brass and 316 stainless steel fittings resist impact better than Noryl fittings.
    NEMA 4X Enclosure Rating—NEMA 4X rated switches protect against dust, weather, and washdowns.
    For Pipe
    Size
    Flow Set Point Range, gpm
    Max. Flow Rate, gpm
    Paddle Material
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Brass Body with 1 NPT Male Threaded Brass Fittings
     
    Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles
    1
    2
    4
    6
    4.9 to 17.6
    13.7 to 56.4
    35.3 to 118
    60.3 to 245
    27, 105, 397, 900304 Stainless Steel
    160 psi @ 70° F33 to 2253.7 amp @ 240V AC
    7.4 amp @ 120V AC
    5"NEMA 4X
    C-UL Listed
    UL Recognized Component
    4971K50000000
    1
    2
    4
    6
    6 to 10.2
    18.8 to 32.8
    39.7 to 73.5
    79.2 to 166
    27, 105, 397, 900304 Stainless Steel
    160 psi @ 70° F33 to 3003.7 amp @ 240V AC
    7.4 amp @ 120V AC
    5"C-UL Listed
    UL Listed
    4971K3000000
     
    316 Stainless Steel Body with 1 NPT Male Threaded 316 Stainless Steel Fittings
     
    Set-Point-Adjustment Removable Layered Paddles, Set-Point-Adjustment Trimmable Paddles
    1
    2
    4
    6
    6 to 10.2
    18.8 to 32.8
    39.7 to 73.5
    79.2 to 166
    27, 105, 397, 900304 Stainless Steel
    160 psi @ 70° F33 to 3003.7 amp @ 240V AC
    7.4 amp @ 120V AC
    5"C-UL Listed
    UL Listed
    4971K4000000
     