    UL Class CC Time-Delay Midget Fuses for Motors

    Image of Product. Front orientation. Fuses. UL Class CC Time-Delay Midget Fuses for Motors .
    These fuses can withstand the high inrush current caused by a motor starting. They provide comparable performance with a smaller footprint than standard size fuses. All have a rejection-style end that safeguards against replacement errors. Use them to protect power distribution branch circuits. Designed for use with Fuse Blocks for UL Class CC Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: ATD-R, CCMR, LP-CC
     
    13/32" Overall Diameter
    15CC600V AC, 500V DC200,000 amp @ 600V AC
    20,000 amp @ 500V DC
    1 1/2"2FerruleTime DelayNoYesUL Listed
    000000000000000000000
     

    Fast-Acting Glass-Tube Fuses

    Image of Product. 1/4" Dia.. Front orientation. 1/4" Overall Diameter. Fast-Acting Glass-Tube Fuses .
    Image of Product. 5mm Dia.. Front orientation. 5 mm Overall Diameter. Fast-Acting Glass-Tube Fuses .

    1/4" Dia.

    5mm Dia.

    These fuses open circuits quickly when surges are detected. The clear glass tube makes it easy to see when fuses open. Use them with electronics, control panels, and other sensitive components. Select them by their diameter. Designed for use with Fuse Blocks for Glass-Tube Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Pkg.
    Fuse Trade
    Size
    Current,
    amp
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Certification
    Pkg.
    Qty.
    1-9
    10-Up
    Manufacturer Equivalent Fuse: 312, AGC, GGC
     
    1/4" Overall Diameter
    3AG1532300 amp @ 32V AC1 1/4"1Fast ActingYesUL Listed
    500000000000000000
     
    Manufacturer Equivalent Fuse: 217, GDB, GSB
     
    5 mm Overall Diameter
    1525035 amp @ 250V AC20 mm1Fast ActingYes50000000000000000
     
    Manufacturer Equivalent Fuse: 235, GGM, GMA
     
    5 mm Overall Diameter
    15125150 amp @ 125V AC20 mm1Fast ActingYesUL Recognized Component
    50000000000000000
     

    UL Class RK5 Fuses

    Image of Product. Front orientation. Fuses. UL Class RK5 Fuses , Ferrule Cartridge Fuse, With Blown Fuse Indicator.
    Image of Product. Front orientation. Fuses. UL Class RK5 Fuses , Ferrule Cartridge Fuse, Without Blown Fuse Indicator.

    Ferrule Cartridge

    Fuse, With Blown

    Fuse Indicator

    Ferrule

    Cartridge Fuse,

    Without Blown

    Fuse Indicator

    Also known as dual-element fuses, these time-delay fuses withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor. They have a rejection-style end design that safeguards against replacement errors. Use with Fuse Blocks for UL Class RK5 Fuses.
    With Blown Fuse Indicator—Fuses with blown fuse indicator have a dot on the side that changes color when the fuse blows.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    UL File
    No.
    CSA File
    No.
    1-9
    10-Up
    Manufacturer Equivalent Fuse: FLN-R, FRN-R, TR-R
     
    9/16" Overall Diameter
    15RK5250V AC, 125V DC200,000 amp @ 250V AC
    20,000 amp @ 125V DC
    2"2FerruleTime DelayNoYesUL Listed, CSA Certified
    E4273053787_C_0000000000000000000000
     
    Manufacturer Equivalent Fuse: FLN-R-ID, FRN-R-ID, TR-R-ID
     
    9/16" Overall Diameter
    15RK5250V AC, 160V DC200,000 amp @ 250V AC
    20,000 amp @ 160V DC
    2"2FerruleTime DelayYesYesUL Listed, CSA Certified
    E2137012636_0_000000000000000000000
     
    Manufacturer Equivalent Fuse: FLS-R, FRS-R, TRS-R
     
    13/16" Overall Diameter
    15RK5600V AC, 300V DC200,000 amp @ 600V AC
    20,000 amp @ 300V DC
    5"2FerruleTime DelayNoYesUL Listed, CSA Certified
    E4273053787_C_00000000000000000000
     
    Manufacturer Equivalent Fuse: FRS-R-ID, IDSR, TRS-R-ID
     
    13/16" Overall Diameter
    15RK5600V AC, 600V DC200,000 amp @ 600V AC
    20,000 amp @ 600V DC
    5"2FerruleTime DelayYesYesUL Listed, CSA Certified
    000000000000000000
     

    Fast-Acting Ceramic-Tube Fuses

    Image of Product. 1/4" Dia.. Front orientation. 1/4" Overall Diameter. Fast-Acting Ceramic-Tube Fuses .

    1/4" Dia.

    These fuses open circuits quickly when surges are detected. They can withstand temperature swings and high ambient temperatures better than glass-tube fuses. Use with electronics, control panels, and other sensitive components. Select these fuses by their diameters. Designed for use with Fuse Blocks for Ceramic-Tube Fuses.
    1/4" Overall Diameter—1/4" dia. fuses can be used in high-current electronic circuits such as microwave ovens.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Pkg.
    Fuse Trade
    Size
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Certification
    Current,
    amp
    Pkg.
    Qty.
    1-9
    10-Up
    Manufacturer Equivalent Fuse: 322, GBB
     
    1/4" Overall Diameter
    3AB250V AC, 125V DC10,000 amp @ 125V AC
    10,000 amp @ 125V DC
    1 1/4"1Fast ActingNoUL Recognized Component, CSA Certified
    15000000000000000000000
     
    Manufacturer Equivalent Fuse: 314, ABC, GAB
     
    1/4" Overall Diameter
    3AB250V AC, 125V DC10,000 amp @ 125V AC
    10,000 amp @ 125V DC
    1 1/4"1Fast ActingNoUL Listed, CSA Certified
    15500000000000000000
     

    Time-Delay Ceramic-Tube Fuses

    Image of Product. 1/4" Dia.. Front orientation. 1/4" Overall Diameter. Time-Delay Ceramic-Tube Fuses .

    1/4" Dia.

    Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges. They can withstand temperature swings and high ambient temperatures better than glass-tube fuses. Use them with electronics, control panels, and other sensitive components. Select these fuses by their diameters. Designed for use with Fuse Blocks for Ceramic-Tube Fuses.
    1/4" Overall Diameter—1/4" dia. fuses can be used in high-current electronic circuits such as microwave ovens.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Fuse Trade
    Size
    Current,
    amp
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Certification
    UL File
    No.
    1-9
    10-Up
    Manufacturer Equivalent Fuse: 326, GSA, MDA
     
    1/4" Overall Diameter
    3AB1525010,000 amp @ 125V AC1 1/4"1Time DelayNoUL Listed, CSA Certified, CE Marked
    E191800000000000000000000
     

    Automotive Fuses

    Image of Product. Front orientation. Fuses. Automotive Fuses , Mini Fuse Blade.
    Image of Product. Front orientation. Fuses. Automotive Fuses , Standard Fuse Blade.

    Mini

    Fuse

    Blade

    Standard

    Fuse Blade

    These fuses are suitable for low-voltage automotive and other electronic applications. Use with Fuse Blocks for Automotive Fuses.
    Fast Acting—Fast-acting fuses open circuits quickly when surges are detected.
    With Blown Fuse Indicator—Fuses with blown fuse indicator have a light that turns on when the fuse blows.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Overall
    Current,
    amp
    Voltage,
    V DC
    Breakthrough Current
    @ Voltage
    Lg.
    Ht.
    Blade
    Ht.
    No. of
    Elements
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Certification
    Pkg.
    Qty.
    Pkg.
    Manufacturer Equivalent Fuse: 257, AF, ATC, ATO
     
    Standard Fuse Blade
    15121,000 amp @ 12V DC3/4"0.73"0.25"1Fast ActingYes20000000000000
    15321,000 amp @ 32V DC3/4"0.73"0.25"1Fast ActingNoUL Listed
    500000000000
     
    Manufacturer Equivalent Fuse: 297, AF2, ATM
     
    Mini Fuse Blade
    15121,000 amp @ 12V DC0.43"0.65"0.3"1Fast ActingYes2000000000000
    15321,000 amp @ 32V DC0.43"0.65"0.3"1Fast ActingNoUL Listed
    5000000000000
     

    UL Class CC Time-Delay Midget Fuses for Transformers

    Image of Product. Front orientation. Fuses. UL Class CC Time-Delay Midget Fuses for Transformers .
    Designed to handle high inrush currents and the initial current cycle unique to transformers, these fuses provide comparable performance with a smaller footprint than standard size fuses. Use them to protect power distribution branch circuits. They’re for use with Fuse Blocks for UL Class CC Fuses.
    With Rejection-Style End—Fuses with a rejection-style end safeguard against replacement errors.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: ATQ-R, FNQ-R, KLD-R
     
    13/32" Overall Diameter
    15CC600V AC, 300V DC200,000 amp @ 600V AC
    20,000 amp @ 300V DC
    1 1/2"1FerruleTime DelayNoYesUL Listed
    0000000000000000000
     

    UL Class J Time-Delay Fuses for Tight Spaces

    Image of Product. Front orientation. Fuses. UL Class J Time-Delay Fuses for Tight Spaces , Ferrule Cartridge Fuse, With Blown Fuse Indicator.
    Image of Product. Front orientation. Fuses. UL Class J Time-Delay Fuses for Tight Spaces , Ferrule Cartridge Fuse, Without Blown Fuse Indicator.

    Ferrule

    Cartridge Fuse,

    With Blown Fuse

    Indicator

    Ferrule

    Cartridge Fuse,

    Without Blown

    Fuse Indicator

    Also known as dual-element fuses, these fuses withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor. More compact than UL Class RK1 or RK5 fuses, they are suitable for tight spaces. Use with Fuse Blocks for UL Class J Fuses.
    With Blown Fuse Indicator—Fuses with blown fuse indicator have a dot on the side that changes color when the fuse blows.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: AJT, JTD, LPJ-SP
     
    13/16" Overall Diameter
    15J600V AC, 300V DC300,000 amp @ 600V AC
    100,000 amp @ 300V DC
    2 1/4"2FerruleTime DelayNoNoUL Listed, CSA Certified
    000000000000000000000
     
    Manufacturer Equivalent Fuse: AJT, JTD-ID, LPJ-SPI
     
    13/16" Overall Diameter
    15J600V AC, 400V DC200,000 amp @ 600V AC
    100,000 amp @ 400V DC
    2 1/4"1FerruleTime DelayYesNoUL Listed, CSA Certified
    00000000000000000
     

    UL Class CC Fast-Acting Midget Fuses

    Image of Product. Front orientation. Fuses. UL Class CC Fast-Acting Midget Fuses .
    These fuses open circuits quickly when surges are detected. They provide comparable performance with a smaller footprint than standard size fuses. Use them in power distribution branch circuits. All have a rejection-style end that safeguards against replacement errors. Designed for use with Fuse Blocks for UL Class CC Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: ATM-R, KLK-R, KTK-R
     
    13/32" Overall Diameter
    15CC600200,000 amp @ 600V AC1 1/2"1FerruleFast ActingNoYesUL Listed
    00000000000000000000
     

    Time-Delay Midget Fuses

    Image of Product. Front orientation. Fuses. Time-Delay Midget Fuses .
    Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges, such as when starting a motor. Use them to protect equipment—they are not designed for power distribution circuits. Designed for use with Fuse Blocks for Midget Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: ATQ, FLQ, FNQ
     
    13/32" Overall Diameter
    1550010,000 amp @ 500V AC1 1/2"1FerruleTime DelayNoNoUL Listed, CSA Certified
    000000000000000000
     
    Manufacturer Equivalent Fuse: FLM, FNM, TRM
     
    13/32" Overall Diameter
    1525010,000 amp @ 250V AC1 1/2"1FerruleTime DelayNoNoUL Listed, CSA Certified
    000000000000000
     

    Time-Delay Glass-Tube Fuses

    Image of Product. 1/4" Dia.. Front orientation. 1/4" Overall Diameter. Time-Delay Glass-Tube Fuses .

    1/4" Dia.

    Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges. The clear glass tube makes it easy to see when fuses open. Use them with electronics, control panels, and other sensitive components. Select these fuses by their diameters. Designed for use with Fuse Blocks for Glass-Tube Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Pkg.
    Fuse Trade
    Size
    Current,
    amp
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Certification
    Pkg.
    Qty.
    1-9
    10-Up
    Manufacturer Equivalent Fuse: 313, GDL, MDL
     
    1/4" Overall Diameter
    3AG1532300 amp @ 32V AC1 1/4"1Time DelayYesUL Recognized Component
    50000000000000000000
     

    Fast-Acting Midget Fuses

    Image of Product. Front orientation. Fuses. Fast-Acting Midget Fuses .
    These fuses open circuits quickly when surges are detected. Use them to protect equipment—they are not designed for power distribution circuits. Designed for use with Fuse Blocks for Midget Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: ATM, DCM, KLKD
     
    13/32" Overall Diameter
    15600V AC, 600V DC100,000 amp @ 600V AC
    10,000 amp @ 600V DC
    1 1/2"1FerruleFast ActingNoNoUL Listed, CSA Certified
    000000000000000000
     
    Manufacturer Equivalent Fuse: ATM, KLK, KTK
     
    13/32" Overall Diameter
    15600V AC100,000 amp @ 600V AC1 1/2"1FerruleFast ActingNoNoUL Listed, CSA Certified
    0000000000000000000
     
    Manufacturer Equivalent Fuse: BAF, BLF, OTM
     
    13/32" Overall Diameter
    15250V AC10,000 amp @ 250V AC1 1/2"1FerruleFast ActingNoNoUL Listed, CSA Certified
    0000000000000000
     
    Manufacturer Equivalent Fuse: BBS, BLS, SBS
     
    13/32" Overall Diameter
    15600V AC100,000 amp @ 600V AC1 3/8"1FerruleFast ActingNoNoUL Listed, CSA Certified
    0000000000000000
     

    UL Class K5 Fuses

    Image of Product. Front orientation. Fuses. UL Class K5 Fuses , Ferrule Cartridge Fuse.

    Ferrule

    Cartridge Fuse

    Use these fast-acting fuses in applications where temporary overload current is not present, such as in lighting and heating. They open circuits quickly when surges are detected. Use with Fuse Blocks for UL Class K5 Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    UL File
    No.
    CSA File
    No.
    1-9
    10-Up
    Manufacturer Equivalent Fuse: NLN, NON, OT
     
    9/16" Overall Diameter
    15K5250V AC, 250V DC50,000 amp @ 250V AC
    20,000 amp @ 250V DC
    2"1FerruleFast ActingNoNoUL Listed, CSA Certified
    E2137012636_0_000000000000000000000
     
    Manufacturer Equivalent Fuse: NLS, NOS, OTS
     
    13/16" Overall Diameter
    15K5600V AC, 300V DC50,000 amp @ 600V AC
    20,000 amp @ 300V DC
    5"1FerruleFast ActingNoNoUL Listed, CSA Certified
    E2137012636_0_000000000000000000000
     

    UL Class RK1 Time-Delay Fuses

    Image of Product. Front orientation. Fuses. UL Class RK1 Time-Delay Fuses , Ferrule Cartridge Fuse.

    Ferrule

    Cartridge Fuse

    Also known as dual-element fuses, these fuses withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor. They have a rejection-style end design that safeguards against replacement errors. Designed for use with Fuse Blocks for UL Class RK1 Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: A2D-R, LLN-RK, LPN-RK
     
    9/16" Overall Diameter
    15RK1250V AC, 125V DC300,000 amp @ 250V AC
    100,000 amp @ 125V DC
    2"2FerruleTime DelayNoYesUL Listed, CSA Certified
    000000000000000000000
     
    Manufacturer Equivalent Fuse: A6D-R, LLS-RK, LPS-RK
     
    13/16" Overall Diameter
    15RK1600V AC, 300V DC300,000 amp @ 600V AC
    100,000 amp @ 300V DC
    5"2FerruleTime DelayNoYesUL Listed, CSA Certified
    0000000000000000000
     

    UL Class J Fast-Acting Fuses for Tight Spaces

    Image of Product. Front orientation. Fuses. UL Class J Fast-Acting Fuses for Tight Spaces , Ferrule Cartridge Fuse.

    Ferrule

    Cartridge Fuse

    These fuses open circuits quickly when surges are detected. More compact than UL Class RK1 or RK5 fuses, they are suitable for tight spaces. Use with Fuse Blocks for UL Class J Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    UL File
    No.
    1-9
    10-Up
    Manufacturer Equivalent Fuse: A4J, JKS, JLS
     
    13/16" Overall Diameter
    15J600V AC, 200V DC200,000 amp @ 600V AC
    10,000 amp @ 200V DC
    2 1/4"1FerruleFast ActingNoNoUL Listed, CSA Certified
    E427300000000000000000000
     

    UL Class T Fuses for Extra-Tight Spaces

    Image of Product. Front orientation. Fuses. UL Class T Fuses for Extra-Tight Spaces , Ferrule Cartridge Fuse.

    Ferrule

    Cartridge Fuse

    Smaller than UL Class J fuses, these fast-acting fuses can be used in extra-tight spaces such as meters, uninterruptible power supplies, and variable-speed drives. They open circuits quickly when surges are detected. Use with Fuse Blocks for UL Class T Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: A3T, JJN, JLLN
     
    7/16" Overall Diameter
    15T300V AC, 160V DC200,000 amp @ 300V AC
    20,000 amp @ 160V DC
    7/8"1FerruleFast ActingNoNoUL Listed, CSA Certified, CE Marked
    000000000000000000000
     
    Manufacturer Equivalent Fuse: A6T, JJS, JLLS
     
    9/16" Overall Diameter
    15T600V AC200,000 amp @ 600V AC1 1/2"1FerruleFast ActingNoNoUL Listed, CSA Certified, CE Marked
    0000000000000000000
     

    UL Class G Time-Delay Midget Fuses

    Image of Product. Front orientation. Fuses. UL Class G Time-Delay Midget Fuses .
    Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges, such as when starting a motor. They have a smaller footprint than standard size fuses. Protect power distribution branch circuits from overcurrent. Use with Fuse Blocks for UL Class G Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: AG, SC, SLC
     
    13/32" Overall Diameter
    15G600V AC, 170V DC100,000 amp @ 600V AC
    10,000 amp @ 170V DC
    1 5/16"1FerruleTime DelayNoNoUL Listed, CSA Certified
    0000000000000000000
     

    Time-Delay Plug Base Fuses

    Image of Product. Front orientation. Fuses. Time-Delay Plug Base Fuses , Manufacturer Equivalent Fuse: GSL, S.
    Image of Product. Front orientation. Fuses. Time-Delay Plug Base Fuses , Manufacturer Equivalent Fuse: GTL, TL, TLO.

    Manufacturer

    Equivalent

    Fuse: GSL, S

    Manufacturer

    Equivalent

    Fuse: GTL,

    TL, TLO

    Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges, such as during equipment start-up. They are designed to fit into a socket on a panel; match the fuse to your panel socket by the manufacturer equivalent.
    GSL Equivalent Fuse and S Equivalent Fuse—Type GSL and S fuses have a non-interchangeable base to prevent the wrong size fuse from being used.
    GTL Equivalent Fuse, TL Equivalent Fuse, and TLO Equivalent Fuse—Type GTL, TL, and TLO fuses can be used in motor applications.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Current,
    amp
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    No. of
    Elements
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Plug Base
    Fuse Type
    Certification
    Pkg.
    Qty.
    Pkg.
    Manufacturer Equivalent Fuse: GSL, S
    1512510,000 amp @ 125V AC2Time DelayNoType SUL Listed
    40000000000000
     
    Manufacturer Equivalent Fuse: GTL, TL, TLO
    1512510,000 amp @ 125V AC1Time DelayNoEdisonUL Listed
    4000000000000
     

    UL Class RK1 Fast-Acting Fuses

    Image of Product. Front orientation. Fuses. UL Class RK1 Fast-Acting Fuses , Ferrule Cartridge Fuse.

    Ferrule

    Cartridge Fuse

    These fuses open circuits quickly when surges are detected. They have a rejection-style end design that safeguards against replacement errors. Use with Fuse Blocks for UL Class RK1 Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: A6K-R, KLS-R, KTS-R
     
    13/16" Overall Diameter
    15RK1600V AC, 250V DC200,000 amp @ 600V AC
    20,000 amp @ 250V DC
    5"1FerruleFast ActingNoYesUL Listed, CSA Certified
    00000000000000000000
     

    Fuses for Multimeters

    Image of Product. Front orientation. Fuses. Fuses for Multimeters .
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Current,
    amp
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    Each
    Manufacturer Equivalent Fuse: DMM-B, FLU, FSM
     
    13/32" Overall Diameter
    151,000V AC; 1,000V DC20,000 amp @ 1,000V AC
    20,000 amp @ 1,000V DC
    1 1/2"1FerruleFast ActingNoNoUL Recognized Component
    000000000000
     

    UL Class H Replaceable-Element Fuses

    Image of Product. Front orientation. Fuses. UL Class H Replaceable-Element Fuses , Ferrule Cartridge Fuse.

    Ferrule

    Cartridge Fuse

    Replace the current-carrying element rather than the entire fuse after the fuse breaks. Use with Fuse Blocks for UL Class H Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Fuses
    Replacement
    Fuse Elements
    Current,
    amp
    Fuse UL
    Class
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    Each
    Pkg.
    Qty.
    Pkg.
    Manufacturer Equivalent Fuse: REN, RF, RLN
     
    9/16" Overall Diameter
    15H25010,000 amp @ 250V AC2"1FerruleFast ActingNoNoUL Listed
    00000000000000400000000000000
     
    Manufacturer Equivalent Fuse: RES, RFS, RLS
     
    13/16" Overall Diameter
    15H60010,000 amp @ 600V AC5"1FerruleFast ActingNoNoUL Listed
    000000000000040000000000000
     

    1,000V DC Fuses

    Image of Product. Front orientation. Fuses. 1,000V DC Fuses .
    Developed for the solar industry, these fuses meet the needs of high-voltage DC applications. They can withstand the cycling conditions and environment associated with outdoor installations. Designed for use with fuse blocks for 1,000V DC fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Current,
    amp
    Voltage,
    V DC
    Breakthrough Current
    @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    Specs. Met
    Each
    Manufacturer Equivalent Fuse: DCT, PV
     
    13/32" Overall Diameter
    151,00010,000 amp @ 1,000V DC1 1/2"1FerruleFast ActingNoNoUL Listed
    EN 63000, IEC 6300000000000000000
     

    Touch-Safe Fuses

    Image of Product. Front orientation. Fuses. Touch-Safe Fuses .
    Prevent accidental contact with electrical circuits—these fuses have an enclosed design with recessed plug-in blades. Also known as dual-element fuses, they withstand current overload for a short time so they won't open when exposed to harmless temporary surges, such as when starting a motor.
    With Blown Fuse Indicator—Fuses with blown fuse indicator have a dot on the side that turns red when the fuse blows.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Fuses
    DIN-Rail Mount
    Fuse Blocks
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp.
    No. of
    Elements
    Fuse Protection Type
    With Blown Fuse
    Indicator
    Certification
    Specs. Met
    Each
    Each
    Manufacturer Equivalent Fuse: TCF
    15CF600V AC, 300V DC300,000 amp @ 600V AC
    100,000 amp @ 300V DC
    1.88"3/4"1"2Time Delay, Touch SafeYesUL Listed, CSA Certified
    EN 63000, IEC 6300000000000000000000000000000
     

    Replacement Elements for UL Class H Fuses

    Image of Product. Front orientation. Fuse Elements. Replacement Elements for UL Class H Fuses.
    Breakthrough current, labeled on your fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Current,
    amp
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    Fuse Protection
    Type
    Pkg.
    Qty.
    Pkg.
    1525010,000 amp @ 250V ACFast Acting400000000000000
    1560010,000 amp @ 600V ACFast Acting40000000000000

    Long-Time-Delay Plug Base Fuses

    Image of Product. Front orientation. Fuses. Long-Time-Delay Plug Base Fuses .
    These fuses have a longer time delay than standard time-delay fuses. Use them in motor applications where the motor is cycled on and off frequently. Also known as Edison-type fuses, they are designed to fit into a socket on a panel; match the fuse to your panel socket by the manufacturer equivalent.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Current,
    amp
    Voltage,
    V AC
    Breakthrough Current
    @ Voltage
    No. of
    Elements
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Plug Base
    Fuse Type
    Certification
    Pkg.
    Qty.
    Pkg.
    Manufacturer Equivalent Fuse: GT, T
    1512510,000 amp @ 125V AC2Time DelayNoEdisonUL Listed
    40000000000000
     
    back to top