McMaster-Carr logo
    Filter by
    Fuse UL Class
    Fuse Protection Type
    Manufacturer Equivalent Fuse
    Overall Length
    Fuse Type
    Breakthrough Current @ Voltage
    Overall Diameter
    Length
    Rejection-Style End
    Cartridge Fuse Type
    With Blown Fuse Indicator
    Diameter
    Attribute Image
    Number of Elements
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    7 Products

    UL Class G Fast-Acting Midget Fuses

    Image of Product. Front orientation. Fuses. UL Class G Fast-Acting Midget Fuses .
    These fuses open circuits quickly when surges are detected. They have a smaller footprint than standard size fuses. Use them to protect power distribution branch circuits from overcurrent. Designed for use with Fuse Blocks for UL Class G Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: AG, SC, SLC
     
    13/32" Overall Diameter
    1G600V AC, 170V DC100,000 amp @ 600V AC
    10,000 amp @ 170V DC
    1 5/16"1FerruleFast ActingNoNoUL Listed, CSA Certified
    74485K881000000000000
    2G600V AC, 170V DC100,000 amp @ 600V AC
    10,000 amp @ 170V DC
    1 5/16"1FerruleFast ActingNoNoUL Listed, CSA Certified
    74485K8820000000000
    3G600V AC, 170V DC100,000 amp @ 600V AC
    10,000 amp @ 170V DC
    1 5/16"1FerruleFast ActingNoNoUL Listed, CSA Certified
    74485K8830000000000
    5G600V AC, 170V DC100,000 amp @ 600V AC
    10,000 amp @ 170V DC
    1 5/16"1FerruleFast ActingNoNoUL Listed, CSA Certified
    74485K8840000000000
    6G600V AC, 170V DC100,000 amp @ 600V AC
    10,000 amp @ 170V DC
    1 5/16"1FerruleFast ActingNoNoUL Listed, CSA Certified
    74485K8850000000000
     

    UL Class G Time-Delay Midget Fuses

    Image of Product. Front orientation. Fuses. UL Class G Time-Delay Midget Fuses .
    Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges, such as when starting a motor. They have a smaller footprint than standard size fuses. Protect power distribution branch circuits from overcurrent. Use with Fuse Blocks for UL Class G Fuses.
    Breakthrough Current @ Voltage—Breakthrough current at voltage, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
    Each
    Current,
    amp
    Fuse UL
    Class
    Voltage
    Breakthrough Current @ Voltage
    Overall
    Lg.
    No. of
    Elements
    Cartridge
    Fuse Type
    Fuse Protection
    Type
    With Blown Fuse
    Indicator
    Rejection-Style
    End
    Certification
    1-9
    10-Up
    Manufacturer Equivalent Fuse: AG, SC, SLC
     
    13/32" Overall Diameter
    10G600V AC, 170V DC100,000 amp @ 600V AC
    10,000 amp @ 170V DC
    1 5/16"1FerruleTime DelayNoNoUL Listed, CSA Certified
    74485K88600000000000
    15G600V AC, 170V DC100,000 amp @ 600V AC
    10,000 amp @ 170V DC
    1 5/16"1FerruleTime DelayNoNoUL Listed, CSA Certified
    74485K887000000000
     
    back to top