Filter by
Measures
Detects
For Use On
Environment
Hazardous Location Protection Type
Alert Type
Electrical Connection
For Use With
Certification
DFARS Specialty Metals
Battery Chemistry
Combustion Analyzers
Measurement Range | Calculated Range | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Use On | Ambient Temp., ° F | Flue Gas Temp., ° F | Flue Gas Oxygen | Carbon Monoxide, ppm | Combustion Efficiency | Carbon Dioxide | Air Free Carbon Monoxide, ppm | Excess Air | Accuracy | Batteries Included | Each | ||
| Kerosene, Natural Gas, Oil, Propane | 25 to 110 | -4 to 1,200 | 0% to 20.9% | 0 to 2,000 | 0.1% to 100% | 0% to 15% | 0 to 9,999 | 0% to 250% | ±0.3% of Oxygen Content | Yes | 3937K35 | 0000000 | |
Portable Multi-Gas Detectors
Detects (Measuring Range) | Volume (Sound) @ Distance | Temp. Range, ° F | Batteries Included | Hazardous Location Rating | Enclosure Rating | Each | ||
|---|---|---|---|---|---|---|---|---|
| Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL) Oxygen (0% to 30% Vol.) Carbon Monoxide (0 ppm to 1,999 ppm) Hydrogen Sulfide (0 ppm to 200 ppm) | 95 dBA @ 30 cm | -40 to 140 | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA AEx Da Ia IIC T4 Ga Ex Da Ia IIC T4 Ga | IP68 | 18995T42 | 000000000 |
Carbon Dioxide Meters
Electrical | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Carbon Monoxide Concentration Measured Range, ppm | Temp. Range, ° F | Mobility | Ht. | Wd. | Dp. | Power Source | Batteries Included | No. of Batteries Req. | Battery Size | Connection | No. of Blades | Voltage, V AC | Cord Lg., ft. | Each | ||
| 0 to 9,999 | 32 to 122 | Portable | 8 1/4" | 2 1/2" | 1 1/2" | Battery, Electric | Yes | 6 | AAA | Straight Blade | 2 | 240 | 3 | 39035K691 | 0000000 | |
Portable Multi-Gas Detectors with Probe
Detects (Measuring Range) | Volume (Sound) @ Distance | Temp. Range, ° F | Batteries Included | Includes | Tube Lg., ft. | Hazardous Location Rating | Enclosure Rating | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL) Oxygen (0% to 30% Vol.) Carbon Monoxide (0 ppm to 1,999 ppm) Hydrogen Sulfide (0 ppm to 200 ppm) | 95 dBA @ 30 cm | -40 to 140 | Yes | Sampling Probe, Tubing Assembly, Battery | 25 | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA AEx Da Ia IIC T4 Ga Ex Da Ia IIC T4 Ga | IP68 | 18995T44 | 000000000 |
Propane Detectors
Trigger Point, ppm | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Voltage, V AC | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4,200 | 80 dB @ 10 ft. | -20 to 120 | 6 3/4" | 3 1/4" | 1 3/4" | 120 | 6 | No | 3/16" | Canada | 6631T41 | 0000000 |
Environmental-Monitoring Modules for Development Boards
Modules with Temperature, Humidity, and Air Quality Sensor
Output Data | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resolution, bit | Freq., Hz | Measures | Temp. Range, ° C | RH | Carbon Dioxide Concentration Measured, ppm | Input Voltage, V DC | I2C Address | Connection Method | No. of Qwiic Connections | Lg. | Wd. | Each | |||
I²C Communication Protocol—Qwiic Connection | |||||||||||||||
| 16 | 0.2 | Temperature, Relative Humidity, Carbon Dioxide Level | -10 to 60 | 0% to 100% | 0 to 40,000 | 2.4 to 5.5 | 0x62 | Solder | 2 | 1" | 1" | 7126N11 | 000000 | ||
Modules with Temperature, Humidity, Air Quality, and Barometer Sensor
Measures | Temp. Range, ° C | RH | Equiv. Carbon Dioxide Concentration Measured, ppm | Total Volatile Organic Compound, ppb | Barometric Pressure, in. Hg | Input Voltage, V DC | I2C Address | Connection Method | No. of Qwiic Connections | Lg. | Wd. | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
I²C Communication Protocol—Qwiic Connection | |||||||||||||||
| Temperature, Relative Humidity, Equivalent Carbon Dioxide, Total Volatile Organic Compound Concentration, Air Quality Index, Barometric Pressure | 0 to 65 | 20% to 80% | 400 to 650,000 | 0 to 65,000 | 8.9 to 32.5 | 1.2 to 3.6 | 0x52 0x53 0x76 0x77 | Solder | 2 | 1" | 1" | 7126N14 | 000000 | ||
Methane Detectors
Trigger Point, ppm | Volume (Sound) @ Distance | Temp., ° F | Ht. | Wd. | Dp. | Voltage, V AC | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 10,000 | 80 dB @ 10 ft. | -20 to 120 | 6 3/4" | 3 1/4" | 1 3/4" | 120 | 6 | No | 3/16" | Canada | 6631T43 | 0000000 |
Surface-Mount Multi-Gas Detectors
Detects (Trigger Point) | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Voltage, V AC | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Propane (420 ppm); Methane (5,000 ppm); Hydrogen (200 ppm); Carbon Monoxide (150 ppm) | 80 dB @ 10 ft. | -20 to 120 | 6 3/4" | 3 1/4" | 1 3/4" | 120 | 6 | No | 3/16" | Canada | 6631T18 | 0000000 |
Early-Warning Surface-Mount Hydrogen Detectors
Trigger Point | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Electrical Connection | Voltage, V AC | Fasteners Included | Mounting Hole Dia. | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1%; 2% | 60 dB @ 10 ft. | 14 to 104 | 7" | 4 3/4" | 2 1/2" | Screw Terminal | 120, 240 | No | 3/16" | 71095K71 | 000000000 |
Hydrogen Sulfide Detectors
Hydrogen Sulfide Concentration Measured, ppm | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Batteries Included | Hazardous Location Rating | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nonreplaceable Batteries | ||||||||||||
| 0 to 100 | 95 dBA @ 30 cm | -4 to 122 | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IECEx Ex Ia IIC T4 AEx Ia IIC T4 ATEX II 2 G Ex Ia IIC T4 Gb | IP67 | 18995T85 | 0000000 | ||
Replaceable Batteries | ||||||||||||
| 0 to 200 | 95 dBA @ 30 cm | 14 to 104 | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IECEx Ex Ia IIC T4 Ga ATEX II 1 G Ex Ia IIC T4 Ga | IP67 | 18995T19 | 000000 | ||
Oxygen Detectors
Oxygen Detectors | Batteries | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Oxygen Volume Percent Concentration Measured | Volume (Sound) @ Distance | Ht. | Wd. | Dp. | Temp. Range, ° F | Batteries Included | Battery Chemistry | Hazardous Location Rating | Enclosure Rating | Each | Pkg. Qty. | Pkg. | ||||
Detectors with Nonreplaceable Battery | ||||||||||||||||
| 0% to 25% | 95 dBA @ 30 cm | 3 1/2" | 2" | 1" | -4 to 122 | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA AEx Ia IIC T4 ATEX II 2 G Ex Ia IIC T4 Gb IECEx Ex Ia IIC T4 | IP67 | 18995T81 | 0000000 | — | ——— | 0 | ||
Detectors with Replaceable Battery | ||||||||||||||||
| 0% to 25% | 95 dBA @ 30 cm | 3 1/2" | 2" | 1" | -4 to 122 | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 0 Groups IIC, IIB, IIA AEx Ia IIC T4 ATEX II 1 G Ex Ia IIC T4 Ga ATEX II 2 G Ex Ia IIC T4 Gb IECEx Ex Ia IIC T4 | — | 18995T92 | 000000 | 1 | 7821K72 | 00000 | ||
Air Filter Monitors for Supplied-Air Respirators for Plant Air Lines
Monitors with Low-Battery Alarm
![]() | ![]() |
Closed | Open |
Respirator Filter Monitors | Respirator Filter Monitor Calibration Kits | Replacement Filters | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | ||||||||||||||||||||||
For Use With | Inlet Coupling Size | Outlet Coupling Size | Max. Flow Rate @ Pressure | Max. Pressure, psi | Pressure Regulation Range, psi | Regulating Accuracy | Wd. | Ht. | Max. Temp., ° F | Battery Type | Batteries Included | Battery Size | No. of Batteries Req. | Cord Lg., ft. | Each | Each | Each | |||||
Plastic Housing | ||||||||||||||||||||||
Quick-Disconnect Male Inlet × Quick-Disconnect Female Outlet | ||||||||||||||||||||||
| Solid Particles, Oil, Water | 1/2 | 1/4 | 15 ft³/min @ 100 psi | 150 | 0 to 160 | ±1 psi | 19" | 13" | 120 | Disposable | No | AA | 8 | 10 | 6793N17 | 000000000 | 6793N13 | 0000000 | 6793N12 | 0000000 | ||
Monitors with Data Logging Capabilities and Low-Battery Alarm
![]() | ![]() |
Closed | Open |
Respirator Filter Monitors | Respirator Filter Monitor Calibration Kits | Replacement Filters | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | |||||||||||||||||||||
For Use With | Inlet Coupling Size | Outlet Coupling Size | Max. Flow Rate @ Pressure | Max. Pressure, psi | Pressure Regulation Range, psi | Regulating Accuracy | Wd. | Ht. | Max. Temp., ° F | Battery Type | Batteries Included | No. of Batteries Req. | Cord Lg., ft. | Each | Each | Each | |||||
Plastic Housing | |||||||||||||||||||||
Quick-Disconnect Male Inlet × Quick-Disconnect Female Outlet | |||||||||||||||||||||
| Solid Particles, Oil, Water | 1/4 | 1/4 | 15 ft³/min @ 100 psi | 150 | 0 to 160 | ±1 psi | 18 1/2" | 13" | 100 | Rechargeable | Yes | 1 | 7 | 6793N14 | 000000000 | 6793N15 | 0000000 | 6793N16 | 0000000 | ||
Stick-On Carbon Monoxide Indicators
![]() |
Trigger Point, ppm | Mounting Profile | Ht. | Wd. | Backing Type | Each | |||
|---|---|---|---|---|---|---|---|---|
| 100 | Surface | 2 1/4" | 2 1/4" | Adhesive | 1085T85 | 00000 | ||
Carbon Monoxide Detectors for Fire Alarm Systems
Volume (Sound) @ Distance | Mounting Profile | Lg. | Wd. | Dp. | Tandem Signaling Capable | Electrical Connection | Voltage, V DC | Current @ Voltage | Certification | Cannot Be Sold To | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 85 dBA @ 10 ft. | Surface | 4 1/2" | 3" | 1 1/2" | Yes | Screw Terminal | 12 24 | 0.04 amp @ 12V DC 0.04 amp @ 24V DC | UL Listed | Canada | 1030N1 | 0000000 | ||
Surface-Mount Hydrogen Detectors
Electrical | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Trigger Point, ppm | Volume (Sound) @ Distance | Temp. Range, ° F | Ht. | Wd. | Dp. | Connection | No. of Blades | Voltage, V AC | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Cannot Be Sold To | Each | ||
| 8,000 | 80 dB @ 10 ft. | -20 to 120 | 6 3/4" | 3 1/4" | 1 3/4" | Straight Blade | 2 | 120 | 6 | No | 3/16" | Canada | 6631T42 | 0000000 | |
Portable Carbon Monoxide Detectors
Carbon Monoxide Concentration Measured, ppm | Volume (Sound) @ Distance | Temp., ° F | Ht. | Wd. | Dp. | Batteries Included | Certification | Hazardous Location Rating | Enclosure Rating | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nonreplaceable Batteries | |||||||||||||
| 0 to 500 | 95 dBA @ 30 cm | -4 to 122 | 3 1/2" | 2" | 1" | Yes | CSA-US Certified CSA Certified CE Marked | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IECEx Ex Ia IIC T4 ATEX II 2 G Ex Ia IIC T4 Gb AEx Ia IIC T4 | IP67 | 18995T83 | 0000000 | ||
Replaceable Batteries | |||||||||||||
| 0 to 2,000 | 95 dBA @ 30 cm | 14 to 104 | 3 1/2" | 2" | 1" | Yes | CSA-US Certified CSA Certified CE Marked | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IECEx Ex Ia IIC T4 Ga ATEX II 1 G Ex Ia IIC T4 Ga | IP67 | 18995T15 | 000000 | ||





































